HE FL# FL12772-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Mule-Hide Products Co., Inc.
Address/Phone/Email 1195 Prince Hall Dr
Beloit, WI 53511-5481
(608) 365-3111 Ext 809
lindareith@trinityerd.com
Authorized Signature Timothy McFarland
lindareith@trinityerd.com
Technical Representative Tim McFarland
Address/Phone/Email 1195 Prince Hall Dr
Suite A
Beloit, WI 535115481
(608) 365-3111
tim.mcfarland@mulehide.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Single Ply Roof Systems
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
v Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
v Validation Checklist- Hardcopy Received
Certificate of Independence FL12772 R3 COI 2015 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D6878 2008
FM 4470 1992
FM 4474 2004
TAS 114 2011
Equivalence of Product Standards
Certified By
https:/tfloridabuilding.org/pr/pr_app M.aspx?param=wGEVXQMDgsmFBeODh9XIlcG2e5SIxuCbIZLDRz%2bpOQo2j3ylyBRTA°/`3d°/`3d 1/2
4/28J2017 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/20/2015
Date Validated 03/27/2015
Date Pending FBC Approval 03/31/2015
Date Approved 06/22/2015
Date Revised 04/03/2017
5 a ry of Products
FL# Model,Number or Name Description
12772.1 Mule-Hide TPO-c Single Ply Roof Thermoplastic polyolefin single ply roof systems
Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL12772 R3 II 2015 03 FINAL Al ER MULE-HIDE TPO-
Approved for use outside HVHZ:Yes c FL12772-R3.odf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-495 Created by Independent Third Party: Yes
Other: 1.)The DP noted in this application pertains to one Evaluation Reports
particular assembly. Refer to the ER appendix for all I FL12772 R3 AE 2015 03 FINAL ER MULE-HIDE-TPO-
assemblies and DP's. 2.) Refer to ER section 5 for Limits of j c FL12772-R3.pdf
Use. Created by Independent Third Party: Yes
0
Contact Us:: 2601 Blair Stone Road.Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
in E__
Credit Card
Safe
https:/Moridabuilding.org/pr/pr_ppp dM.aspx?param=wGEVXCNADgsmFBcODh9XIlcG2e5SlxuCbIZLDRzg/`2bpOQo2j3ylyBRTA/`,3d°/3d 2/2
TRINI"iY ERD
APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
1A Wood New,Reroof(Tear-Off),Recover C Mechanically Attached Insulation,Bonded Roof Cover 3
1B Wood New,Reroof(Tear-Off),Recover D Insulated,Mechanically Attached Roof Cover 3
1C Wood New,Reroof(Tear-Off),Recover E Non-Insulated,Mechanically Attached Roof Cover 4
1D Wood New Construction F Non-Insulated,Bonded Roof Cover 4
2A Steel or Conc. New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
2B Steel or Conc. New,Reroof(Tear-Off),Recover C Mechanically Attached Insulation,Bonded Roof Cover 6-7
2C Steel or Conc. New,Reroof(Tear-Off),Recover D-1 Insulated,Mechanically Attached Roof Cover 8-10
2D Steel or Conc. New,Reroof(Tear-Off),Recover D-2 Insulated,Mechanically Attached Roof Cover(RUSS Strips) 11
3A Concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 12
4A LWIC New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 13
4A-1 LWIC over Steel New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 13
4A-2 LWC over Conc. New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 14
5A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 14
6A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 15
6B Steel Recover D-1 Insulated,Mechanically Attached Roof Cover 16
6C Steel or Concrete Recover E Non-Insulated,Mechanically Attached Roof Cover 17
6D Various Recover F-2 New LWC over Existing Roof,Bonded Roof Cover 18
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Mule-Hide HDP Fastener with 3"Insulation Plate. Minimum%-inch steel penetration,engage the top flute of the steel deck
➢ Steel Deck: Mule-Hide HDP Fastener with 3"Insulation Plate. Minimum''%-inch steel penetration,engage the top flute of the steel deck.
➢ Concrete Deck: Mule-Hide HDP Fastener with 3"Insulation Plate.Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation
instructions.
3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or SECUROCK
Glass-Mat Roof Board that meets the CtA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC 2603.4.1 or 2603.6,when installed with the roof cover.
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached membrane),whereby the membrane fasteners are
installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. The structural deck shall be of equal or
greater type,thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof
deck shall be documented through proper codified and/or FBC Approval documentation.
5. Preliminary insulation attachment for System Type D=Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board.
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 18
TRINITY ERA
6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturers published instructions:
➢ OlyBond 500(OB-500): Continuous%to 1-inch wide ribbons,12-inch o.c.using PaceCart or SpotShot application devices.
➢ 3M CR-20: Continuous 2Y:to 3Y:-inch wide ribbons,12-inch o.c.
➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed fora particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢ OlyBond 500(OB500): MDP -315.5 psf (Min.0.5-inch thick Poly ISO 1,H-Shield or ENRGY 3)
➢ OlyBond 500(OB500): MPD -487.5 psf (Min.0.5-inch thick Poly ISO 2 or ACFoam II)
➢ 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117,FM LPDS 1-29 and
ANSI/SPRI WD1. Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no
rational analysis is permitted.
11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing
roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52,
ANSI/SPRI IA-1 or TAS 124.
13. For System Type D,steel deck applications,the roof membrane shall be run with its length perpendicular to the steel deck flutes.
14. For Recover Applications using System Type D,the insulation is optional. Alternatively,min.0.5-inch H-Shield HD or min.0.25-inch to 0.625-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or
SECUROCK Glass-Mat Roof Board or min.3/8-inch Insulfoam R-Tech EPS or Fan-Fold may be used as a separator board,preliminarily attached prior to roof cover installation. The existing roof system shall be suitable
for a recover application.
15. For adhered membrane systems,side laps shall be minimum 3-inch wide sealed with min.1.5-inch heat weld. Membrane adhesive application rates are as follows:
➢ Mule-Hide TPO-c with Mule-Hide TPO-c Bonding Adhesive in a contact application at rate of 60 W/gal.
➢ Mule-Hide TPO-c with WBBA 2000 in a contact application at rate of 120 ft2/gal.
➢ Mule-Hide TPO-c Fleece Back with WBBA 2000 in a wet-lay application at a rate of 120 ft'/gal.
16. For membrane systems attached using TPO 10-inch Pressure-Sensitive RUSS,the underside of the membrane which comes in contact with the tape shall be primed with HP-250 Primer. The membrane shall be
secured by placing the primed portion onto the tape portion of the TPO 10-inch Pressure-Sensitive RUSS and roll with a steel hand roller to ensure contact.
17. For bonded membrane systems,unless otherwise noted,reference to"Mule-Hide TPO-c"membrane below also includes"Mule-Hide TPO-c EXTRA".
18. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization N9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 18
TRINITY I ERD
TABLE 1A: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Deck Top Insulation Layer MDP
Base Insulation layer Roof Cover/Adhesive
No. (See Note 1) Type Fasteners Attach (psf)
Min.1.5-inch Poly ISO 1,H-
W-1 Min.19/32"plywood or wood plank (Optional)One or more layers,any Shield,ACFoam II,Poly ISO 2 or See Note 2 1 per 2 ftZ Mule-Hide TPO-c/WBBA 2 or
-45.0'
combination,loose laid ENRGY 3 Mule Hide TPO c Bonding Adhesive
TABLE 16: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE D: INSULATED,MECHANICALLY ATTACHED ROOF COVER
Insulation Layer
System Roof Cover MDP
Roof Deck (See Note 14)
No. (psf)
Type Attach Membrane Fasteners Spacing
Min.19/32-inch plywood or wood plank at
W 2 max.24"spans attached using 8d ring shank One or more layers, Preliminarily Mule-Hide Mule-Hide EHD Fasteners and 2.4 6-inch o.c.within 5.5-inch wide laps spaced 90.5-inch -52.5
nails spaced 6"o.c.in the field and#10 ring any combination attached TPO-c Seam Plates o.c. Outside of lap sealed with 1.5-inch heat-weld
shank nails spaced 4"o.c.at the perimeter
Min.19/32-inch plywood or wood plank at
W 3 max.24"spans attached using 8d ring shank One or more layers, Preliminarily Mule-Hide Mule-Hide EHD Fasteners and 2.4 6-inch o.c.within 5.5-inch wide laps spaced 66.5-inch -67.5
nails spaced 6"o.c.in the field and#10 ring any combination attached TPO-c Seam Plates o.c. Outside of lap sealed with 1.5-inch heat-weld
shank nails spaced 4"o.c.at the perimeter
6-inch o.c.within S-inch wide laps spaced 67-inch o.c.
Min.23/32-inch OSB at max.24-inch spans Outside of lap sealed with 1.5-inch heat-weld
W-4
attached using 8d ring shank nails spaced 6" One or more layers, Preliminarily Mule-Hide Mule-Hide EHD Fasteners and 2.4 and -67.5
o.c.in the field and 8"o.c.at intermediate any combination attached TPO-c Seam Plates 6-inch o.c.in one row centered between the laps.
supports Center row covered with 6-inch wide cover strip
sealed with 1.5-inch heat weld at all edges
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 18
TRINITY ERD
TABLE 1C: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER
Thermal Barrier Roof Cover
System Roof Deck MOP
No. Type Attach Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld (psfl
Min.19/32-inch thick Mule-Hide FR Deck
Panel A or C or Barrier Technology Corp (Optional)Any Mule-Hide EHD 1.5-inch
W-5 'Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 12-inch o.c. 5-inch 48-inch o.c. outside -30.0
attached using No.8 x 2Y-inch long thermal barrier 2.4 Seam Plates
course thread screws spaced 6"o.c.
Min.19/32-inch thick Mule-Hide FR Deck
Panel A or C or Barrier Technology Corp (Optional)Any Mule-Hide EHD 1.5-inch
W-6 'Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-inch 72-inch o.c. outside -52.5
attached using No.8 x 2A-inch long thermal barrier 2.4 Seam Plates
course thread screws spaced 6"o.c.
Min.19/32-inch thick Mule-Hide FR Deck
Panel A or C or Barrier Technology Corp (Optional)Any Mule-Hide EHD 1.5-inch
W-7 'Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-inch 48-inch o.c. outside -75.0
attached using No.8 x 2Y-inch long thermal barrier 2.4 Seam Plates
course thread screws spaced 6"o.c.
Min.19/32-inch plywood at max.24-inch (Optional)Any Mule-Hide EHD 48-inch o.c.(over 1.5-inch
W-8 spans attached using 8d ring shank nails approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5.5-inch structural members) outside 75.0
spaced 6-inch o.c. thermal barrier 2.4 Seam Plates
TABLE 1D:WOOD DECKS—NEW CONSTRUCTION
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Roof Deck Roof Cover MOP
No. Membrane Application (Psfl
Min.15/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at Mule-Hide TPO-c WBBA 2000 -45.0
W 9 max.24-inch spans attached using No.8 x 2%-inch long course thread screws spaced 6"o.c.
Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at
W-10 max.24-inch spans attached using No.8 x 2Y:-inch long course thread screws spaced 6"o.c. Mule Hide TPO-c WBBA 2000 52.5
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL32772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 18
TRINITY'ERD
TABLE 2A: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
System Deck Base Insulation Layer Top Insulation Layer MOP
No. (See Note 1) Type Fastener Attach Type Attach Roof Cover/Adhesive (Psf)
Min.22 ga.,type B, in.0.5-inch Dens Deck or Dens Min.1.5-inch ACFoam II,Poly ISO 2, Mule-Hide TPO-c/WBBA 2000
SC-1 Grade 33 steel or min. Deck Prime See Note 2 1 per 2.0 ft2 ENRGY 3,Poly ISO 1 or H-Shield followed OB500 or Mule-Hide TPO-c Bonding -37.5*
2,500 psi concrete by Min.0.25-inch Dens Deck Prime Adhesive
Min.22 ga.,type B, Min.2-inch Poly ISO 1.H-Shield,H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000
SC-2 Grade 33 steel or min. Shield CG See Note 2 1 per 4.0 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -37.5
2,500 psi conc. Adhesive
Min.22 ga.,type B, Min.1.5-inch ACFoam II,Poly ISO Mule-Hide TPO-c/WBBA 2000
SC-3 Grade 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 2.0 ft2 Additional layers of base insulation OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi concrete Adhesive
Min.22 ga.,type B, Mule-Hide TPO-c/WBBA 2000
Min.1.5-inch ACFoam II,Poly ISO 2 Min.0.25-inch Dens Deck,Dens Deck *
SC-4 Grade 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 2.0 ft Prime OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi concrete Adhesive
Min.22 ga.,type B, in.0.5-inch Dens Deck or Dens 2 Min.1.5-inch ACFoam II,Poly ISO 2, Mule-Hide TPO-c/WBBA 2000
SC-5 Grade 33 steel or min. Deck Prime See Note 2 1 per 2.0 ft ENRGY 3,H-Shield or Poly ISO 1 OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi concrete Adhesive
Min.22 ga.,type B, Min.2.0-inch ACFoam II,Poly ISO Mule-Hide TPO-c/WBBA 2000
SC-6 Grade 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 4.0 ftz Additional layers of base insulation OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi concrete Adhesive
Min.22 ga.,type B, Min.2.0-inch ACFoam 11,Poly ISO 2 Min.0.25-inch Dens Deck,Dens Deck Mule-Hide TPO-c/WBBA 2000
SC-7 Grade 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 4.0 ft Prime OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi concrete Adhesive
Min.22 ga.,type B, Min.1.5-inch Poly ISO 1,H-Shield, 2 Min.0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000
SC-8 Grade 33 steel or min. H-Shield CG See Note 2 1 per 3.2 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi conc. Adhesive
Min.22 ga.,type B, Min.2-inch Poly ISO 1,H-Shield,H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000
SC-9 Grade 33 steel or min. Shield CG See Note 2 1 per 2.67 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -45.0
2,500 psi conc. Adhesive
Min.22 ga.,type B, Min.2-inch Poly ISO 1,H-Shield,H- 2 Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000
SC-10 Grade 33 steel or min. Shield CG See Note 2 1 per 1.6 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -60.0
2,500 psi conc. Adhesive
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 18
ERD
TRINRY
TABLE 2B: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Deck Top Insulation Layer MOP
Base Insulation Layer Roof Cover/Adhesive
No. (See Note 1) Type Fasteners Attach (psf)
SC-11 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers,any Min 7/16"APA or TECO rated OSB Trufast SIP LD 1 per 3.2 ft2 Mule-Hide TPO-c/WBBA 2000 or -37.5*
or min.2,500 psi concrete combination,loose laid Fasteners Mule-Hide TPO-c Bonding Adhesive
SC-12 Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any Min.1-inch Poly ISO 2,ACFoam II See Note 2 1 per 1.6 ft2 Mule-Hide TPO-c/WBBA 2000 or -37.5*
or min.2,500 psi concrete combination,loose laid or ENRGY 3 Mule-Hide TPO-c Bonding Adhesive
SC-13 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min.0.5-inch H-Shield HD See Note 2 1 per 2.67 ft= Mule-Hide TPO-c/Mule-Hide TPO-c -37.5* •
or min.2,500 psi concrete any combination,loose laid Bonding Adhesive
SC-14 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.25-inch SECUROCK Gypsum- See Note 2 1 per 2.67 ft2 Mule-Hide TPO-c/WBBA 2000 or -37.5*
or min.2,500 psi concrete any combination,loose laid Fiber Roof Board Mule-Hide TPO-c Bonding Adhesive
SC-15 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.50-inch SECUROCK Gypsum- See Note 2 1 per 3.2 ftz Mule-Hide TPO-c/WBBA 2000 or -45.0*
or min.2,500 psi concrete any combination,loose laid Fiber Roof Board Mule-Hide TPO-c Bonding Adhesive
SC-16 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.625-inch SECUROCK See Note 2 1 per 4.0 ft2 Mule-Hide TPO-c/WBBA 2000 or -45.0*
or min.2,500 psi concrete any combination,loose laid Gypsum-Fiber Roof Board Mule-Hide TPO-c Bonding Adhesive
SC-17 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers,any Min 7/16"APA or TECO rated OSB Trufast SIP LD 1 per 2.67 ftz Mule-Hide TPO-c/WBBA 2000 or -45.0*
or min.2,500 psi concrete combination,loose laid Fasteners Mule-Hide TPO-c Bonding Adhesive
SC-18 Min.22 ga.,type B,Grade 33 steel One or more layers,any combination, Min 7/16"APA or TECO rated OSB See Note 2 1 per 3.6 ftZ Mule-Hide TPO-c/WBBA 2000 or -45.0*
or min.2,500 psi concrete loose laid Mule-Hide TPO-c Bonding Adhesive
Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any Min.1-inch Poly ISO 1,H-Shield,H- Mule-Hide TPO-c/WBBA 2000 or
SC 19 or min.2,500 psi concrete combination,loose laid Shield CG See Note 2 1 per 1.6 ftZ Mule-Hide TPO-c Bonding Adhesive 45.0*
SC-20 Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any Min.1.5-inch ACFoam II,Poly ISO 2,H-Shield,Poly ISO 1,H-Shield See Note 2 1 per 2.0 ftZ Mule-Hide TPO-c/WBBA 2000 or -45.0*
or min.2,500 psi concrete combination,loose laid CG,ENRGY 3 Mule-Hide TPO-c Bonding Adhesive
SC-21 Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any Min.2.0-inch ACFoam 11,Poly ISO 2,H-Shield,Poly ISO i,H-Shield See Note 2 1 per 4.0 ft2 Mule-Hide TPO-c/WBBA 2000 or _q5.0*
or min.2,500 psi concrete combination,loose laid CG,ENRGY 3 Mule-Hide TPO-c Bonding Adhesive
SC-22 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min.0.5-inch H-Shield HD See Note 2 1 per 2.0 ft2 Mule-Hide TPO-c/Mule-Hide TPO-c -45.0*
or min.2,500 psi concrete any combination,loose laid Bonding Adhesive
SC-23 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers,any Min 7/16"APA or TECO rated OSB See Note 2 1 per 1.9 ft2 Mule-Hide TPO-c/WBBA 2000 -52.5
or min.2,500 psi concrete combination,loose laid
SC-24 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.5-inch Dens Deck Prime See Note 2 1 per 1.6 ftz Mule-Hide TPO-c/Mule-Hide TPO-c -60.0
or min.2,500 psi concrete any combination,loose laid Bonding Adhesive
Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers,any z Mule-Hide TPO-c/Mule-Hide TPO-c
SC 25 or min.2,500 psi concrete combination,loose laid Min 7/16"APA or TECO rated OSB See Note 2 1 per 1.9 ft Bonding Adhesive 75.0
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 18
TRINITY ERD
TABLE 2B: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Deck Top Insulation Layer MOP
No. (See Note 1) Base Insulation Layer Type Fasteners Attach Roof Cover/Adhesive (psf)
Min 2.0-inch ACFoam II,Poly ISO 1, Mule-Hide TPO-c/Mule-Hide TPO-c
SC-26 Min.n. ga.,type c Grade 33 steel (Optional)One or more layers,any Poly ISO 2,H-Shield,H-Shield CG, See Note 2 1 per 1.6 ft2 -75.0
or min.2,500 psi concrete combination,loose laid ENRGY 3 Bonding Adhesive
Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 0.5-inch SECUROCK Gypsum- z Mule-Hide TPO-c/Mule-Hide TPO-c
SC-27 See Note 2 1 per 1.6 ft -82.5
or min.2,500 psi concrete any combination,loose laid Fiber Roof Board Bonding Adhesive
SC-28 Min.22 ga.,type B,Grade 33 steel Min.1.5-inch thick,one or more layers, Min 7/16-inch APA or TECO rated See Note 2 1 per 1 ftz Mule-Hide TPO-c/Mule-Hide TPO-c 97 5
or min.2,500 psi concrete any combination,loose laid OSB Bonding Adhesive
SC-29 Min.20 ga.,type B,Grade 33 steel (Optional)Min.1.5-inch thick,one or Min.0.625-inch SECUROCK See Note 2 1 per 1.33 ft2 Mule-Hide TPO-c/Mule-Hide TPO-c -112.5
or min.2,500 psi concrete more layers,any combination,loose laid Gypsum-Fiber Roof Board Bonding Adhesive
SC-30 Min.18 ga.,type B,Grade 33 steel Min.2-inch thick,one or more layers, Min.0.5-inch SECUROCK Gypsum- See Note 2 1 per 1.33 ft2 Mule Hide TPO-c/Mule-Hide TPO-c -112.5
or min.2,500 psi concrete any combination,loose laid Fiber Roof Board Bonding Adhesive
Min.22 ga.,type B,Grade 33 steel (Optional)One or more layers,any : Mule-Hide TPO-c/Mule-Hide TPO-c
SC 31 or min.2,500 psi concrete combination,loose laid Min 2-inch H-Shield CG See Note 2 1 per 1 ft Bonding Adhesive 120.0
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 18
TRINITY ERD
TABLE 2C: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER
System Roof Deck Insulation Layer(See Note 14) Roof Cover MOP
No. Type Attach Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld (Psf)
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-32 Grade 33 steel or min. more layers,any Prelim. Mule-Hc EXTRA
HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 138.5-inch outside
-30.0
2,500 psi concrete combination attach or TPO c EXTRA Seam Plate O.C. outside
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
ch
SC-33 Grade 33 steel or min. more layers,any Prelim. Mule-HideXTRA HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 91-inch o.c. outside
-30.0
2,500 psi concrete combination attach or TPO c EXTRA Seam Plate outside •
Min.22 ga.,type B,Grade Min.1-inch,one or more
33 steel,6 ft span,5/8" layers,any combination
diameter puddle welds 6" (optional for recover) Prelim. Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and 2.4" 12-inch o.c. 5.5 inch 90.5-inch 1.5-inch 30.0
SC-34 o.c.,side laps secured 24" followed by 3/8-inch attach or TPO-c EXTRA Plus Seam Plates O.C. outside
o.c.w/W-141"long self- Insulfoam R-Tech EPS or
tapping hex-head screw Fan-Fold
Min.22 ga.,type B,Grade
33 steel,6 ft span,5/8" Mule-Hide TPO-c
Min.1-inch,one or
diameter puddle welds 6" Prelim. (min.nominal 60- Mule-Hide EHD Plus Fasteners and 2.4" 12-inch o.c. 5.5-inch 90.5-inch 1.5-inch
SC-35 o.c.,side laps secured 24" more layers,any Attach mil)or TPO-c Plus Seam Plates O.C. outside 37.5
o.c.w/Y.."-14x1"long self- combination EXTRA
tapping hex-head screw
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
nch
SC-36 Grade 80 steel or min. more layers,any Prelim. Mule-Hide EXTRTPO-A
HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 115-inch o.c. outside 37 5
2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate outside
Min.22 ga.,type B,Grade
33 steel,6 ft span,5/8" Min.1-inch,one or
diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam 138.5-inch 1.5-inch
SC 37 o.c.,side laps secured 24" more layers,any attach or TPO-c EXTRA Plate 6 inch o.c. 5.5-inch O.C. outside 45.0
o.c.w/W-14x1"long self- combination
tapping hex-head screw
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Plus Fasteners and 2.4"
SC-38 Grade 80 steel or min. more layers,any Prelim. Mule-Hc EXTRA
Plus Seam Plates(steel only)or HDP 12-inch o.c. 5.5-inch 115-inch o.c. outside
-45.0
2,500 psi concrete combination attach or TPO c EXTRA Fastener and 2.4"Seam Plates outside
Min.18 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fasteners(steel only)or
Prelim. Mule-Hide TPO-c 1.5-inch
SC-39 Grade 33 steel or min. more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 115-inch o.c. outside -45.0
2,500 psi concrete combination Seam Plates
Min.22 ga.,type B,Grade
33 steel,6 ft span,5/8" Mule-Hide TPO-c
Min.1-inch,one or
diameter puddle welds 6" Prelim. (min.nominal 60- Mule-Hide EHD Fastener and 2.4"Seam 114.5-inch 1.5-inch
SC-40 o.c.,side laps secured 24" more layers,any attach mil)or TPO-c Plate 6-inch o.c. 5.5-inch O.C. outside 45.0
o.c.w/'/."-14x1"long self- combination EXTRA
tapping hex-head screw
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 18
.' TRINITY iERD
TABLE 2C: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER
System Insulation Layer(See Note 14) Roof Cover MOP
Roof Deck
No. Type Attach Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld (psf)
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-41 Grade 80 steel or min. more layers,any Prelim. Mule-Hide EXTTPCRA
HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 114.5-inch outside
-45.0
2,500 psi concrete combination attach or TPO c EXTRA Seam Plate D.C. outside
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Plus Fasteners and 2.4"
SC-42 Grade 33 steel or min. more layers,any Prelim. Mule-Hide EXTTPCRA
Plus Seam Plates(steel only)or HDP 12-inch o.c. 5.5-inch 91-inch o.c. outside
-45.0
2,500 psi concrete combination attach or TPO c EXTRA Fastener and 2.4"Seam Plates outside
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-43 Grade 80 steel or min. more layers,any Prelim. Mule-Hide HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 91-inch o.c. outside
-45.0
2,500 psi concrete combination attach or TPO c EXTRA Seam Plate outside
Min.22 ga.,type B,Grade
33 steel,6 ft span,5/8" Min.1-inch,one or
diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam 66.5-inch 1.5-inch
SC-44 o.c.,side laps secured 24" more layers,any attach or TPO-c EXTRA Plate 6 inch o.c. 5.5-inch O.C. outside 45.0
o.c.w/W-14x1"long self- combination
tapping hex-head screw
Min.22 ga.,type B,Grade
33 steel,6 ft span,5/8" Mule-Hide TPO-c
Min.1-inch,one or
diameter puddle welds 6" Prelim. (min.nominal 60- Mule-Hide EHD Plus Fasteners and 2.4" 114.5-inch 1.5-inch
SC 45 o.c.,side laps secured 24" more layers,any attach mil)or TPO-c Plus Seam Plates 6-inch o.c. 5.5-inch O.C. outside 52.5
o.c.w/W-141"long self- combination EXTRA
tapping hex-head screw
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
Prelim. Mule-Hide -c 138.5-inch 1.5-inch
SC-46 Grade 33 steel or min. more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch D.C. outside -52.5
2,500 psi concrete combination Seam Plate
Min.22 ga.,type B, Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or 1.5-inch
SC-47 Grade 33 steel or min. more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 91-inch o.c. outside -52.5
2,500 psi concrete combination Seam Plate
Min.22 ga.,type B,Grade
33 steel,6 ft span,5/8" Min.1-inch,one or
diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam 90.5-inch 1.5-inch
SC-48 o.c.,side laps secured 24" more layers,any attach or TPO-c EXTRA Plate 6-inch o.c. 5.5-inch O.C. outside 52.5
o.c.w/%"-14x1"long self- combination
tapping hex-head screw
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
Prelim. Mule-Hide -c 42.5-inch 1.5-inch
SC-49 Grade 33 steel or min. more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch D.C. outside -52.5
2,500 psi concrete combination Seam Plate
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL32772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9 of 18
TRINITY ERD
TABLE 2C: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER
System Roof Deck Insulation Layer(See Note 14) Roof Cover MDP
No. Type Attach Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld (Psf)
Min.22 ga.,type B,Grade Min.1-inch,one or more
33 steel,6 ft span,5/8" layers,any combination
diameter puddle welds 6" (optional for recover) Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam 138.5-inch 1.5-inch
SC 50 o.c.,side laps secured 24" followed b 3/8-inch 6 inch o.c. 5.5-inch 60.0
p v attach or TPO-c EXTRA Plate O.C. outside
o.c.w/Y"-14x1"long self- Insulfoam R-Tech EPS or
tapping hex-head screw Fan-Fold
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Plus Fasteners and 2.4"
SC-51 Grade 33 steel or min. more layers,any Prelim. or TPO-c E TRATPO Plus Seam Plates(steel only)or HDP 6-inch o.c. 5.5-inch 138.5-inch outside
-60.0
2,500 psi concrete combination attach or TPO c EXTRA Fastener and 2.4"Seam Plates O.C. outside
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-52 Grade 80 steel or min. more layers,any Prelim. or TPC-c E TRATPO HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 138.5-inch outside
-60.0
2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate O.C. outside
Min.1.5-inch,one or
Min.22 ga.,type B, more layers,any Mule-Hide EHD Fastener(steel only)or
SC-53 Grade 33 steel or min. combination followed Loose laid Mule-Hide EXTTPORA
HDP Fastener(concrete only)and 2.4" 6-inch o.c 5.5-inch 91-inch o.c. outside
-60.0
or TPO-c EXTRA outside
2,500 psi concrete by 3/8-inch Insulfoam Seam Plate
R-Tech EPS
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-54 Grade 33 steel or min. more layers,any Prelim. Mule-Hide EXTTPORA
HDP Fastener(concrete only)and 2.4" 12-inch o.c. 5.5-inch 54.5-inch outside
-60.0
2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate O.C. outside
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-55 Grade 33 steel or min. more layers,any Prelim. Mule-Hide EXTTPORA
HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 90.5-inch outside
-67.5
2,500 psi concrete combination attach or TPO-c EXTRA Seam Plate O.C. outside
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-56 Grade 80 steel or min. more layers,any Prelim. Mule-Hide EXTTPORA
HDP Fastener(concrete only)and 2.4" 9-inch o.c. 5.5-inch 54nch outside
-75.0
attach or TPO c EXTRA D.C.o. outside
2,500 psi concrete combination Seam Plate �.
Min.22 ga.,type B, Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or
SC-57 Grade 33 steel or min. more layers,any Prelim. Mule-Hide EXTTPORA
HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch 42.5-inch out inch 82 5
2,500 psi concrete combination attach or TPO c EXTRA Seam Plate O.C. outside
Min.22 ga.,type B, Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or 54.5-inch 1.5-inch
SC-58 Grade 80 steel or min. more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and 2.4" 6-inch o.c. 5.5-inch D.C. outside 90.0
2,500 psi concrete combination Seam Plate
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 10 of 18
TTRRINITY'ERD
TABLE 2D: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED ROOF COVER(RUSS Strips)
System Deck Insulation Roof Cover MOP
No. Type Attach Membrane Fasteners Attachment (Psf)
Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel
TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation
Prelim. spaced 138-inch o.c. The plates are centered over each strip and fastened 6
SC-59 Grade 80 steel or min. layers,any TPO-c or TPO-c only)or HDP Fastener(concrete -30.0
2,500 psi concrete combination attached EXTRA only)and 2.4"Seam Plates inch o.c. Roof cover adhered to each strip by first priming with TPO Tape
Primer at the strip location,then rolling into place with a hand roller.
Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation
Prelim. spaced 114-inch o.c. The plates are centered over each strip and fastened 6-
SC-60 Grade 80 steel or min. layers,any TPO-c or TPO-c only)or HDP Fastener(concrete -45.0
2,500 psi concrete combination attached EXTRA only)and 2.4"Seam Plates inch o.c. Roof cover adhered to each strip by first priming with TPO Tape
Primer at the strip location,then rolling into place with a hand roller.
Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation
Prelim. spaced 90-inch o.c. The plates are centered over each strip and fastened 6-
SC-61 Grade 80 steel or min. layers,any TPO-c or TPO-c only)or HDP Fastener(concrete -52.5
2,500 psi concrete combination attached EXTRA only)and 2.4"Seam Plates inch o.c. Roof cover adhered to each strip by first priming with TPO Tape
Primer at the strip location,then rolling into place with a hand roller.
Min.22 ga.,type e, One or more Mule-Hide Mule-Hide EHD Fastener(steel
TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation
Prelim. spaced 120-inch o.c. The plates are centered over each strip and fastened 6-
SC-62 Grade 80 steel or min. layers,any TPO-c or TPO-c only)or HDP Fastener(concrete -60.0
2,500 psi concrete combination attached EXTRA only)and 2.4"Seam Plates inch o.c. Roof cover adhered to each strip by first priming with HP-250
Primer at the strip location,then rolling into place with a hand roller.
Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation
Prelim. spaced 60-inch o.c. The plates are centered over each strip and fastened 12-
SC-63 Grade 80 steel or min. layers,any TPO-c or TPO-c only)or HDP Fastener(concrete -60.0
2,500 psi concrete combination attached EXTRA only)and 2.4"Seam Plates inch o.c. Roof cover adhered to each strip by first priming with HP-250
Primer at the strip location,then rolling into place with a hand roller.
l
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL32772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 11 of 18
TRINITY ERD
TABLE 3A: CONCRETE DECKS—NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER
System Roof Deck Base Insulation Layer Top Insulation Layer Roof Cover MOP
No. (See Note 1) Type Attach Type Attach Membrane Application (psf)
C-1. Min.2,500 psi Min.1.5-inch Poly ISO 1,H-Shield,H-Shield CG OB500 Min.0.25-inch SECUROCK Gypsum- OB500 Mule-Hide TPO-c Mule-Hide TPO-c -120.0
concrete Fiber Roof Board Bonding Adhesive
Min.2,500 psi Min.1.5-inch ACFoam 11,H-Shield,ENRGY 3 or Poly ISO 1,Poly (Optional)Additional layers of base
C_2. OB500 OB500 Mule-HideTPO-c WBBA 2000 -127.5
concrete ISO 2 insulation
Min.2,500 psi (Optional)Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly OB500 Min.%-inch Dens Deck or Dens OB500 Mule-Hide TPO-c WBBA 2000 -127.5
C-3. concrete ISO 1,Poly ISO 2 Deck Prime
Min.2,500 psi Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1,Poly OB500 (Optional)Additional layers of base OB500 Mule-Hide TPO-c Mule-Hide TPO-c 150.0
C 4. concrete ISO 2 insulation Bonding Adhesive
C-5. Min.2,500 psi (Optional)Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly OB500 Min.X-inch Dens Deck or Dens OB500 Mule-Hide TPO-c Mule-Hide TPO-c -150.0
concrete ISO 1,Poly ISO 2 Deck Prime Bonding Adhesive
Min.2,500 psi Min.0.25-inch SECUROCK Gypsum-
Mule-Hide TPO-c
C-6. concrete Min.2-inch Poly ISO 1,H-Shield,H-Shield CG OB500 Fiber Roof Board OB500 Mule-Hide TPO-c Bonding Adhesive or -247.5
WBBA 2000
C 7 Min.2,500 psi Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1,Poly CR-20 (Optional)Additional layers of base CR-20 Mule-Hide TPO-c WBBA 2000 -127.5
concrete ISO 2 insulation
C 8 Min.2,500 psi (Optional)Min.1.5-inch ACFoam 11,H-Shield,ENRGY 3 or Poly CR-20 Min.Y..-inch Dens Deck or Dens CR-20 Mule-Hide TPO-c WBBA 2000 -127.5
concrete ISO 1,Poly ISO 2 Deck Prime
Min.2,500 psi Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1,Poly CR-20 (Optional)Additional layers of base CR-20 Mule-Hide TPO-c Mule-Hide TPO-c -232.5
C 9' concrete ISO 2 insulation Bonding Adhesive
Min.2,500 psi (Optional)Min.1.5-inch ACFoam CR 20 CR-20 Mule Hide TPO c 11,H-Shield,ENRGY 3 or Poly Min.%-inch Dens Deck or Dens Mule-Hide TPO-c 232.5
C-10. concrete ISO 1,Poly ISO 2 1 Deck Prime Bonding Adhesive
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M35060.06.09-R3 for FL12772-R3
Certificate of Authorization N9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 12 of 18
'\,J
TRINITY!ERD
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS-NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE A-1A: BONDED INSULATION,BONDED ROOF COVER
Deck
System Base Insulation Layer Coverboard MOP
No. (See Note 1) Roof Cover/Adhesive (psf)
Struct LWC Type Attach Type Attach
LWC-1 Structural Min.250 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or OB500 (Optional)Additional layers base OB500 Mule-Hide TPO-c/Mule-Hide TPO-c -225.0
concrete Elastizell Range II LWIC H-Shield insulation Bonding Adhesive
Structural Min.200 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or (Optional)Additional layers base Mule-Hide TPO-c/Mule-Hide TPO-c
LWC-2 CR-20 CR-20 180.0
concrete Elastizell Range II LWIC H-Shield insulation Bonding Adhesive
LWC-3 Structural Min.200 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or CR-20 (Optional)Additional layers base CR-20 Mule-Hide TPO-c/Mule-Hide TPO-c 222 5
concrete Celcore MF Cellular Concrete H-Shield insulation Bonding Adhesive
LWC-4 Structural Min.200 psi,Min.2-inch thick, Min.1-inch Poly ISO 1 or CR-20 (Optional)Additional layers base CR-20 Mule-Hide TPO-c/Mule-Hide TPO-c 240.0
concrete Mearlcrete H-Shield insulation Bonding Adhesive
TABLE 48-1: LIGHTWEIGHT CONCRETE OVER STEEL DECK-NEW CONSTRUCTION OR RE-ROOF(TEAR OFF)
SYSTEM TYPE F: NON-INSULATED,BONDED ROOF COVER
System
Deck(See Note 1) Roof Cover
MOP
Surface Supplemental Attachment
No. Struct.Deck LWIC Type Attach (psf)
Treatment Fasteners Density
Min.36 pcf wet cast density,min.200 psi,min. WBBA 2000 or Mule-
LWC-5 Min.22 ga.,Type B,Grade 33 steel at 2-inch thick Celcore MF Cellular Concrete(cast None None N/A Mule-Hide Hide TPO-c Bonding -60.0
max.6 ft spans attached 6-inch o.c. with or without min.1"EPS holey board). See TPO-c Adhesive
Note A.
Min.38 pcf wet cast density,min.200 psi,min.
Min.22 ga.,Type B,Grade 33 steel at 1.625-inch thick Celcore MF Cellular Concrete Mule-Hide Mule-Hide TPO-c
LWC-6 max.4 ft spans attached 6-inch O.C. followed by min.1-inch EPS holey board with Celcore PVA None N/A TPO-c Bonding Adhesive 67.5
min.2.0-inch thick top coat. See Note A.
Min.36 pcf wet cast density,min.200 psi,min. WBBA 2000 or Mule-
None
Min.22 ga.,Type B,Grade 33 steel at 2-inch thick Celcore MF Cellular Concrete(cast Mule-Hide HDP Fastener Z Mule-Hide -67.5
LWC-7 max.6 ft spans 6-inch o.c. with or without min.i"EPS holey board). See with 3"Insulation Plate 1 per 9 ft TPO-c Hide TPO-c Bonding SeeNote8
Adhesive
Note A.
Min.36 pcf wet cast density,min.200 psi,min. WBBA 2000 or Mule-
None
Min.22 ga.,Type B,Grade 33 steel at 2-inch thick Celcore MF Cellular Concrete(cast Mule-Hide HDP Fastener 2 Mule-Hide -120.0
LWC 8 max.6 ft spans 6-inch"o.c. with or without min.1"EPS holey board). See with 3"Insulation Plate 1 per 1 ft TPO-c Hide TPO c Bonding Adhesive See Note 8
Note A.
Note A.) If the LWC to be used on the project is not Celcore MF,or if the LWC is existing in a re-roof(tear-off)condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive strength testing shall be in
accordance with ASTM C495(for new pour)or ASTM C109(for existing)and shall yield a minimum 200 psi result. Field withdra wol resistance testing in accordance with TAS 105 and shall yield a MCRF of SS lbf with on Trufost FM-90 Base Sheet Fastener.
If question exists as to the adhesion to the LWC surface,field testing in accordance with FM LPD51-29 or ASTM E907 is recommended.All testing shall be performed by an accredited testing agency acceptable to the AHI.
Note B.)Linear interpolation between supplemental attachment at 1 per 9 ftz for-67.5 psf and 1 per 1 ft'for-110.0 psf is permissible. Such interpolation shall be performed by a qualified design professional to the satisfaction of the AHI.
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL32772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 13 of 18
TRINITY ERD
TABLE 4B-2: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE—NEW CONSTRUCTION
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck Roof Cover MOP
No. Roof Deck LWC Membrane Application (psf)
LWC-9 Min.2,500 psi concrete Min.250 psi,Min.2"thick,Elastizell Range II LWIC Mule-Hide TPO-c WBBA 2000 -67.5
LWC-10 Min.2,500 psi concrete Min.250 psi,Min.2"thick,Elastizell Range II LWIC(EPS board optional) Mule-Hide TPO-c Mule-Hide TPO-c -240.0
Bonding Adhesive
LWC-11 Min.2,500 psi concrete Min.300 psi,Min.2"thick,Elastizell Range II LWIC(no EPS board) Mule-Hide TPO c Mule-Hide TPO-c 495.0 •
Bonding Adhesive
LWC-12 Min.2,500 psi concrete Min.300 psi,Min.2"thick,Celcore Cellular Concrete Mule-Hide TPO-c WBBA 2000 -82.5
LWC-13 Min.2,500 psi concrete Min.300 psi,Min.2"thick,Celcore Cellular Concrete Mule-Hide TPO-c Mule-Hide TPO-c -135.0
Bonding Adhesive
LWC-14 Min.2,500 psi concrete Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF Cellular Concrete(cast with Mule-Hide TPO-c WBBA 2000 -217.5
or without min.1"EPS holey board). See Note A.
LWC-15 Min.2,500 psi concrete Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF Cellular Concrete(cast with Mule-Hide TPO-c Mule-Hide TPO-c -480.0
or without min.1"EPS holey board). See Note A. Bonding Adhesive
Note A.) If the LWC to be used on the project is not Celcore MF,or if the LWC is existing in a re-roof(tear-off)condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive strength testing shall be in
accordance with ASTM C495(for new pour)or ASTM C109(for existing)and shall yield a minimum 200 psi result. Field withdra wal resistance testing in accordance with TAS 105 and shall yield a MCRF of 55 Ibf with an Trufast FM-90 Base Sheet Fastener.
If question exists as to the adhesion to the LWC surface,field testing in accordance with FM LPDS 1-29 or ASTM E907 is recommended.All testing shall be performed by on accredited testing agency acceptable to the AHI.
TABLE SA: GYPSUM DECKS—REROOF(Tear-Off)
SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER
System Roof Deck Base Insulation Layer Top Insulation Layer Roof Cover MDP
No. Type Attach Type Attach Type Application (psf)
G 1. Existing sound gypsum or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1, CR 20 (Optional)Additional layers CR-20 Mule-Hide TPO-c WBBA 2000 127.5
gypsum plank Poly ISO 2 of base insulation
Existing sound gypsum or (Optional)Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Min.Y.-inch Dens Deck or
G-2. CR-20 CR-20 Mule-HideTPO-c WBBA 2000 -127.5
gypsum plank Poly ISO 1,Poly ISO 2 Dens Deck Prime
G-3. Existing sound gypsum or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly ISO 1, CR-20 (Optional)Additional layers CR-20 Mule-Hide TPO-c Mule-Hide TPO-c -232.5
gypsum plank Poly ISO 2 of base insulation Bonding Adhesive
G-4. Existing sound gypsum or (Optional)Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or CR-20 Min.Y.-inch Dens Deck or CR-20 Mule-Hide TPO-c Mule-Hide TPO-c -232.5
gypsum plank Poly ISO 1,Poly ISO 2 Dens Deck Prime Bonding Adhesive
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL32772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 14 of 18
TRINITY ERA
TABLE 6A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER
System Substrate Base Insulation Layer Top Insulation Layer Roof Cover MOP
No. (See Note 12) Type Attach Type Attach Type Application (psf)
Existing asphaltic BUR or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly OB500 (Optional)Additional layers of base OB500 Mule-Hide WBBA 2000 or Mule-Hide 120.0
R-1 mineral surface cap sheet ISO 1,Poly ISO 2 insulation TPO-c TPO-c Bonding Adhesive
Existingasphaltic BUR or ) Min.Y.-inch Dens Deck,Dens Deck
R 2 p (Optional)Min.1.5-inch ACFoam II,H-Shield, OB500 Prime or SECUROCK Gypsum-Fiber OB500 Mule-Hide WBBA 2000 or Mule-Hide -120.0
mineral surface cap sheet ENRGY 3 or Poly ISO 1,Poly ISO 2 Roof Board TPO-c TPO-c Bonding Adhesive
Existing asphaltic BUR or Min.1.5-inch ACFoam II,H-Shield,ENRGY 3 or Poly CR-20 (Optional)Additional layers of base CR-20 Mule-Hide WBBA 2000 127.5
•
R-3 mineral surface cap sheet ISO 1,Poly 150 2 insulation TPO-c
Existingasphaltic BUR or Min.Y.-inch Dens Deck or Dens Deck
R-4 p (Optional)Min. IS inch ACFoam II,H-Shield, CR-20 Prime or SECUROCK Gypsum-Fiber CR-20 TPO-c Mule-Hide WBBA 2000 -127.5
mineral surface cap sheet ENRGY 3 or Poly ISO 1,Poly ISO 2 Roof Board TPO-c
Existing asphaltic BUR or Min.1.5-inch ACFoam 11,H-Shield,ENRGY 3 or Poly CR-20 (Optional)Additional layers of base CR-20 Mule-Hide Mule-Hide TPO-c Bonding 232.5
R-5 mineral surface cap sheet ISO 1,Poly ISO 2 insulation TPO-c Adhesive
Existingasphaltic BUR or Min.X-inch Dens Deck or Dens Deck
R-6 p (Optional)Min.1.5-inch ACFoam II,H-Shield, CR-20 Prime or SECUROCK Gypsum-fiber CR-20 Mule-Hide Mule-Hide TPO-c Bonding -232.5
mineral surface cap sheet ENRGY 3 or Poly ISO 1,Poly ISO 2 Roof Board TPO-c Adhesive
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 15 of 18
rTRINITYERD
TABLE 60: STEEL-RECOVER
SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER
(All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin.)
System Deck Insulation Roof Cover MDP
No. Type Attach Membrane Fasteners Attachment (Psf)
Existing standing seam or lap seam metal roof covers 12-inch o.c.within 5.5-inch wide laps spaced
One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener
R-7 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.138.5-inch o.c.to engage steel purlin. -30.0
thick steel purlins spaced max.138.5-inch o.c. Laps sealed with 1.5-inch heat weld.
Existing standing seam or lap seam metal roof covers 12-inch o.c.within 5.5-inch wide laps spaced
R-8 having min.16 ga.(0.0598-inch)to max.3/16-inch One o mbination attach or TPO c E more layers, Prelim. Mule-Hide EXTTPORA
Mule Hide Purlin Fastener max.115-inch o.c.to engage steel purlin. Laps -45.0
thick steel purlins spaced max.115-inch o.c. any coXTRA and 2.4 Seam Plate sealed with 1.5-inch heat weld. lie
Existing standing seam or lap seam metal roof covers 12-inch o.c.within 5.5-inch wide laps spaced
R-9 having min.16 ga.(0.0598-inch)to max.3/16-inch One o more layers, Prelim. Mule-Hide
attach or TPO-c EXTRA
c E Mule-Hide Purlin Fastener max.54.5-inch o.c.to engage steel purlin. Laps -60.0
thick steel purlins spaced max.54.5-inch o.c. any co
thick and 2.4 Seam Plate sealed with 1.5-inch heat weld.
Existing standing seam or lap seam metal roof covers 6-inch o.c.within 5.5-inch wide laps spaced
One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener
R-10 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.138.5-inch o.c.to engage steel purlin. -60.0
thick steel purlins spaced max.138.5-inch o.c. Laps sealed with 1.5-inch heat weld.
Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 6-inch o.c.within 5.5-inch wide laps spaced
R-11 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.90.5-inch o.c.to engage steel purlin. Laps -67.5
thick steel purlins spaced max.90.5-inch D.C. sealed with 1.5-inch heat weld.
Existing standing seam or lap seam metal roof covers 9-inch o.c.within 5.5-inch wide laps spaced
One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener
R-12 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.114.5-inch o.c.to engage steel purlin. -75.0
thick steel purlins spaced max.114.5-inch o.c. Laps sealed with 1.5-inch heat weld.
Existing standing seam or lap seam metal roof covers One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener 6-inch o.c.within 5.5-inch wide laps spaced
R-13 having min.16 ga.(0.0598-inch)to max.3/16-inch any combination attach or TPO-c EXTRA and 2.4 Seam Plate max.42.5-inch o.c.to engage steel purlin. Laps -82.5
thick steel purlins spaced max.42.5-inch o.c. sealed with 1.5-inch heat weld.
Existing standing seam or lap seam metal roof covers 6-inch o.c.within 5.5-inch wide laps spaced
One or more layers, Prelim. Mule-Hide TPO-c Mule-Hide Purlin Fastener
R-14 having min.16 ga.(0.0598-inch)to max.3/16-inch max.114.5-inch o.c.to engage steel purlin. -90.0
thick steel purlins spaced max.114.5-inch o.c. any combination attach or TPO-c EXTRA and 2.4 Seam Plate Laps sealed with 1.5-inch heat weld.
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 16 of 18
F)o
TRINITY;ERD
TABLE 6C: RECOVER APPLICATIONS
SYSTEM TYPE E-1: NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER
System Deck Roof Cover MOP(psf)
No. (See Note 1) Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld
Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam Plates installed through to
R-15 Existing steel deck Fleece Back,60-mil engage existing deck (Field W/D>695lbf) 12-inch o.c. 5-inch 139 inch o.c. 1.5-inch outside 30.0
Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam Plates installed through to
R-16 min.Grade 80 Fleece Back engage existing deck(Field W/D>695lbf) 12 inch o.c. 5.5 inch 139 inch o.c. 1.5-inch outside 30.0
Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and 2.4"Plus Seam Plates installed
R-17 Existing steel deck 6-inch o.c. 5-inch 139-inch o.c. 1.5 inch outside 37.5 •
Fleece Back,60-mil through to engage existing deck (Field W/D>4341bfJ
Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam Plates installed through to
R-18 min.Grade 80 Fleece Back engage existing deck(Field W/D>434 Ibf) 6 inch o.c. 5.5 inch 139 inch o.c. 1.5 inch outside 37.5
Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and 2.4"Plus Seam Plates installed
R-19 Existing steel deck Fleece Back,60-mil through to engage existing deck (Field W/D>719lbf) 12-inch o.c. 5 inch 115 inch o.c. 1.5 inch outside 37.5
Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and 2.4"Plus Seam Plates installed
R-20 min.Grade 80 Fleece Back through to engage existing deck(Field W/D>719Of) 12-inch o.c. 5.5 inch 115 inch o.c. 1.5 inch outside 37.5
Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Fastener and 2.4"Seam Plates installed through to
R-21 min.Grade 80 Fleece Back engage existing deck(Field W/D>455lbf) 6 inch o.c. 5.5 inch 91-inch o.c. 1.5 inch outside 60.0
Existing steel deck, Mule-Hide TPO-c Mule-Hide EHD Plus Fasteners and 2.4"Plus Seam Plates installed
R-22 12-inch o.c. 5-inch 91-inch o.c. 1.5-inch outside -60.0
min.Grade 80 Fleece Back,60-mil through to engage existing deck(Field W/D>910lbf)
Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and 2.4"Seam Plates installed through to
R-23 12-inch o.c. 5.5-inch 139-inch o.c. 1.5-inch outside -30.0
concrete Fleece Back engage existing deck(Field W/D>695 Ibf)
Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and 2.4"Seam Plates installed through to
R-24 concrete Fleece Back engage existing deck Plates(Field W/D>434 lbf) 6 inch o.c. 5.5 inch 139 inch o.c. 1.5 inch outside 37.5
Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and 2.4"Seam Plates installed through to
R-25 concrete Fleece Back engage existing deck(Field W/D>719lbf) 12-inch o.c. 5.5 inch 115-inch o.c. 1.5-inch outside 37.5
Existing structural Mule-Hide TPO-c Mule-Hide HDP Fastener and 2.4"Seam Plates installed through to
R-26 concrete Fleece Back engage existing deck(Field W/D>455lbf) 6-inch o.c. 5.5 inch 91-inch o.c. 1.5-inch outside 60.0
Existing structural Mule-Hide TPO c Mule-Hide HDP Fastener and 2.4"Seam Plates installed through to
R-27 12-inch o.c. 5-inch 91-inch o.c. 1.5-inch outside 60.0
concrete Fleece Back,60-mil engage existing deck (Field W/D>910 lbf)
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 17 of 18
TRINITY ERD
TABLE 61): RECOVER APPLICATIONS
SYSTEM TYPE F-2: NEW LIGHTWEIGHT CONCRETE OVER EXITISTING ROOF,BONDED ROOF COVER
System Substrate(See Notes 1&12) Roof Cover MOP(psf)
No. Deck Existing Roof Lightweight Concrete Type Attach
Structural Existing asphalt BUR or smooth-or granule-surface Min.250 psi,Min.2-inch thick,Elastizell Range II
R 28 concrete SBS modified bitumen LWIC(EPS board optional) Mule Hide TPO-c WBBA 2000 67.5
Structural Existing asphalt BUR or granule-surface SBS modified Min.250 psi,Min.2-inch thick,Elastizell Range II Mule-Hide TPO-c Bonding
R-29 concrete bitumen LWIC(EPS board optional) Mule Hide TPO c Adhesive 302.5
Structural Existing asphalt BUR or smooth-surface SBS modified Min.250 psi,Min.2-inch thick,Elastizell Range II Mule-Hide TPO-c Bonding
R-30 Mule-Hide TPO-c 342.0 •
concrete Ibitumen I LWIC(EPS board optional) Adhesive i
1i
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R3 for FL12772-R3
Certificate of Authorization#9503 Revision 3:03/18/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 18 of 18