Loading...
HomeMy WebLinkAboutApproved PlansREAR ELEVATION d C'_1 7C" 10" 7.75" �_2 �R 2.75" 5„ 2.2Ss = R N .y D w � ra 5/8" 0 HILTI K83 ANCHOR m (ICC-ESR-2302) ri OR EQUIVALENT n 1/9STEEL WASHER STEEL WASHER RSTM F436 OR EQUIVALENT ti I m N [ m 8.75" — �— CONCRETE EMBEDMENT f j m � f ro RNCHOR BOLT N DETAIL D � W ,y m rd a m a-' 15 1.87 1y-2f1 ri 2.75" B I2.75" 45 bolts of 12' staggered spacing = 44' 2.7S"1 FOUNDATION PLAN SIDE ELEVATION 1 64.44" t = 0.03" 1 = 119.94" 1 = 119.94" t =0.03" t=18.03" 1 = 92.19" t = 0.04" 1 = 29.75" t = 0.09" 1 = 92.19" t = 1 = 29.75" t = 0.04" 1 = 120" 1 = t=0,0t=0.01.04" U 1.8751, rt- 0.25" 2.75" 5" 24" ARCH F�,OFILE 7C" Q 9C" I' ' ' 'N9 IN 18" CTC' W.W.R. 4" (in) m N 11 u stirrups @ 18" CTC Tie Bo M6 00 12" long @6' CT 10" 4-R4 SEC B—B WARNING: DO NOT REMOVE OR REDUCE THE ONCRETE FLOOR OR THE REINFORCING STEEL, RNO/OR RRISE�THE TOPS OF THE FOOTERS ABOVE THE FLOOR OR BUILDIID FAILURE MAY RESULT Minimum Concrete Cover: (a) Concrete Cost against earth: 3" (b) Concrete exposed to earth or wecher: No. 6 through No. 10 bars: 2" No. 5 bar and smaller: 1.5" (c) Concrete not exposed to earth orweother:0.75" 19" FRONT ELEVATION 11'-2.5" 1 2 pcs 10' and 1 PCs 4' n W N Ir )r rr' s H }I —� C LP [IF gRCH Co ECTOR N C e Ye" x "I- SORT' s BOLTS D caNNECTs RICH PANELS To CONIECToR N L m U NTH. CRNECTOR E RLL CONNECTOR N \_��p L/- - } a CONCRETEFOUNORTOW ' a SEC C-C SEC O-D .erg Lers m n W CORNER DETAIL - INDUSTRIAL FOUNDATION N 1� _1 LENGTH OF FOUNDATION 44'-5.5" D] 9"-2.5" INDUSTRIAL BASE CONNECTOR LAYOUT _CL_ GENERAL NOTES ------------- 1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM WITH THE REQUIREMENTS OF THE LATEST REVISION OF THE INTERNATIONAL BUILDING CODE 2012 AND THE FLORIDA BUILDING CODE 2011. DESIGN ACCORDING TO RISI S100-07/S2-10, NORTH AMERICAN. SPECIFICATION FOR THE DESIGN OF COLO-FORME® STEEL STRUCTURAL MEMBERS, AND WITH ANSI/RSCE 7-10. 2, NO LORDS OTHER THAN THOSE GIVEN UNDER "DESIGN DRTR" BELOW SHALL BE IMPOSED ON THE "STRUCTURE" 3. SPECIFIC NOTES AND DETAILS SHOWN ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE BUILDING MANUAL SUPPLIED. 4. THE BUILDING, INCLUDING THE FOUNDATION, MUST BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE DRAWING AND ERECTION INSTRUCTIONS. ANY DEVIATION, UNLESS APPROVED BY US IN WRITING, SHALL NULLIFY OUR CERTIFICATE AND SEAL RND SHALL BE THE SOLE RESPONSIBILITY OF THE ERECTOR. S. A PROFESSIONAL ENGINEER SHOULD BE RETAINED WHERE SITE INSPECTIONS ARE WARRANTED. 6. NO ARCH PANEL MAY BE CUT OR MODIFIED UNLESS. IT IS TO ACCOMMODATE AN ACCESSORY PROVIDED BY THE MANUFACTURER IN ACCORDANCE WITH ITS INSTRUCTIONS RNO/OR THIS DRRWING. 7. MINIMUM SEPARATION FROM THIS BUILDING TO ANY TALLER BUILDING MUST BE THE SMALLER OF 20 FEET AND 6 TIMES THE HEIGHT DIFFERENCE. FOUNDATION NOTES NOTE; THE THE FOUNDRTION ON THE DRAWING SPECIFIES THE MINIMUM REQUIREMENTS. LOCAL BUILDING CODE AND SITE CONDITIONS MAY REQUIRE R STRONGER FOUNDATION, WHICH MUST BE DESIGNED BY R LOCAL ENGINEER, 1. THE FOUNDATION SHALL BE FOUNDED ON NATURAL UNDISTURBED SOIL CAPABLE OF SAFELY SUSTAINING 1500 psf. THIS SHALL BE DESIGNED TO FULLY RESIST ALL ROTATION AT THE BASE OF THE RRCH. 2. SLAB ON GRADE SHALL BE PLACED ON WELL COMPACTED SOIL CAPABLE. OF SUSTAINING 1500 psf WITHOUT RPPRECIRBLE SETTLEMENT. _DESIGN DATA (MATERIALS). 1. CONCRETE F'c = 2500 PSI @ 28 DAYS, RCI 2. REINFORCING STEEL GRADE 10, Fy = 40 KS(, RSTM A615 3. W.W.R. Fy = 65 KSI, RSTM RIBS. 4. M.W.R. 6 x 6 - W1.4 x W1.4 ARCH DATA 24" i 7-1/2" ENDWALL DATA qg BOLTS: SRE GRACE 2 OR RSTM A307 ARCH STEEL THICKNESS - SEE ARCH PROFILE ENDWRLL STEEL THICKNESS = 0.03 in, GALVALUME SHEET STEEL STRUCTURAL QUALITY RSTM SPECIFICATION R782-08 552 ALUMINUM -ZINC ALLOY IHOT DIP COATING) RSTM A792 SPADE SBA 50 KSI MINIMUM YIELD 65 KSI MINIMUM TENSILE HSS 'SECTIONS SHALL CONFORM TO: RSTM R500 GARDE B (Fy = 46 ks0 W SECTIONS SHALL CONFORM TO: RSTM R992 GARDE 50 Wy = 50 ks0 ^� OTHER SECTIONS SHALL CONFORM T0: N ASTM R36 (Fy = 36 ksa N _ ARCH DESIGN DATA IN ACCORDANCE WITH RNSI/RSCE 7-11 0 0 ROOF LIVE LORD (PSF) = 20 PSI GROUND SNOW LORD (PSF) = 0 N Ce: EXPOSURE FACTOR = 1.0 Ct: THERMAL FACTOR = 1.0 m IMPORTANCE FACTOR (SNOW) = B.B p CATEGORY 1/AGRICULTURAL BUILDING ^ x Pnet: COMPONENT WINO PRESSURE (PSFI = +/- 39 V : BASIC WIND SPEED (MPH) = 150 s KIT: VELOCITY PRESSURE EXPOSURE = O.BS WIND EXPOSURE CATEGORY = C N SEISMIC DESIGN CATEGORY = R 00 rV ,N. State of Florida Product Approval # FL15623-R2 LEGAL NOTE This drawing is the property of Future Steel Buildings Intl, Corp. Any duplication of this drawing in whole or in part is strictly forbidden. Anyone doing so will be prosecuted under the full extent of the law. SteelMoster Buildings 73 Word Rd., Broopton, Ontario, Conado, LSS ERB, Phone- (9161 790-MOO / ""o'"c" RK J. LEWIS NOV 0 12016 9 PIERCE, FL X40-19 - 81`L49995 R MODEL: DWG:AL