hll lhlI MIAMI--DADS COUNTY
PRODUCT CONTROL SECTION.
DEPARTMENT OF PERIMITTING,ENVIRONMENT,AND REGULATORY 11805 SW 26 Street,Room 208
AFFAIRS(PERA) Miami,.Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315 2590 F(786)31525-99
NOTICE OF ACCEPTANCE` ND&Ji r NS A ir?;�U. PPCPQ3 ,o;F" .I., �amidade.sov/pera
Tarco Specialty Products,Inc. A ME wUL9vECT i 0 ANY C'I",P.1iEC'rl iC", ...
One Information Way,Suite 225 `f3x.QUIRED BY FIELD INSPECT<<rls T ii'
Little Rock,AR 72202 Ll tY SE UECE 'SAP(I
SCOPE: C1'0 ,1 �i Y 111TH ALL A IN-1 f IAS E
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA
-Product Control Section to be used in Miami Dade County and.other areas where allowed by the
Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County
Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. PERA reserves the right to revoke this acceptance,if it
is determined by Miami-Dade County Product Control Section that.this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to-comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
I
DESCRIPTION:f30#ASTM.Specification Felt;,EasyLay,Fast90,PS200y',PS200' ;1VIS300,
SS400,NR500HT
LABELING:Each unit shall bear a permanent label with the manufacturer's name or pogo,city,state
and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted
herein.
i
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance oflthis product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials,use,and/or manufacture of the product or process.Misuse.of this NTOA as an
endorsement of any product;for sales;advertising or any other purposes shall automatically terminate
this NOA.Failure to comply with any section of this NOA shall.be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded'by the words Miami-Dade Co i ty, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.09-0824.06 and consists of pages 1 through 10!
The submitted documentation was reviewed by Jorge L.Acebo. � I
NOA No.: 11-0912.04
MIAMf•DADE CO UNTY .Expiration Date: 01/25/17
Approval Date: 01/19/12
Page 1 of 10
i
i
i
i
i
i
i
fr
1 C11
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Asphalt,SBS,Polyester
SCOPE:
This acceptance is for 30#ASTM Specification Felt, EasyLay,Fast90, PS200"T, ES200"f69 MS300,
SS400 and NR500HT underlayments as manufactured by Tarco, for use with approved prepared roof
assemblies as described in this Notice of Acceptance: designed to comply with the,Florida Building
Code,including the High Velocity Hurricane Zone of the Florida Building Code.
i
PRODUCTS DESCRIPTION: I j
Product Dimensions Test Specification Product Description
30#ASTM 3' x 727'.rolls ASTM D 226 Type 11 Asphalt saturated felt underlayment
Specification Felt
I
EasyLay 3'x 133'4" ASTM D 226 Type H Sheet material comprising a polyester substrate
rolls coated with bituminous coating for use as an
underlayment in roofing applications. Designed
as a shingle and metA roofing underlayment
and for use in tile roofing assemblies when used
with an approved TAS 103 tile underlayment
cap sheetJ,
Fast90 3' x 36'rolls TAS 103 Granular 'surfaced, asphalt-impregnated organic
ASTM D 249 felt reinforced,bituminous sheet material with a
ASTM D 6380 self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed'as a tile roofing underlayment.
PS20011T 3'x 66'8"rolls TAS 1.03 Fabric suu jfaced,fiberglass reinforced,:SBS
ASTM D 1970 modified bituminous sheet material with a self-
adhesive bottom layer,for use as an
underlayment in sloped roof assemblies.
Designed as a tile and in roofing
underlayment. I
MOO""" 3'x 66'8"rolls ASTM D 1970 Film surfaced,fiberglass reinforced,SBS
modified bituminous sheet material with a self-
adhesive bottom layer,for use as an
underlayment in sloped roof assemblies.
Designed as a metal andlshingle roofing
underlay lent.
NOA No.: 11-0912.04
Expiration Date: 01/25117
MIAMI-DADS COuNTY Approval Date: 01/19/12
Page 2 of 10
I
i
1
L EI
!
MS306 3'x 66'8"rolls ASTM D 1970 Fine.granular surfaced,ifiberglass reinforced,
3' x 33'4"rolls bituminous sheet material with a self-adhesive
bottom layer,for use as!,an underlayment in
sloped roof assemblies.! Designed as an ice and
water shield,and a shinle roofing
underlayment.
SS400 3'x 66'8"rolls ASTM D 1970 Smooth surfaced,fiberglass reinforced,
3'x 33'4"rolls bituminous sheet material with a self-adhesive
bottom layer,for use aslan underlayment in
• sloped roof assemblies.i Designed.as an ice and
water shield,and a shingle and metal roofing
underlayment.
NR500"T 3'x 66'8"rolls ASTM D 1970 Film surfaced,non-reinforced, bituminous sheet
material with a self-adhesive bottom layer,for
use as an Iunderlayment in sloped roof
assemblies. Designed as an ice and water
shield,and a shingle and metal roofing
underlayment.
MANUFACTURING LOCATION:
1. Greencastle,PA
2. Belton,TX
EVIDENCE SUBMITTED:
Test Agency Test.Identifier. Test Name/Report Date
Atlantic&Carribean'Roof ACRC06-013 TAS 103 06/14/06
Consulting,LLC
PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type H 08/22/02
TOT-029-02-01 TAS 110,ASTM D249&D''6380 07/05/05
TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-041-02-01 TAS 110,ASTM D226 Type Il 05/24/06
TOT-042-02-01 ASTM D4798&ASTM G155 05/22/07
Trinity I ERD T3580.10.06-2 TAS 1.03 1.0/26/06
T3580.10.06 TAS 103,ASTM D6380 10/12/06
T30160.08.09-R1 ASTM D1970 1 10/12/10
T10550.07.08 ASTM D4798&ASTM D1970 07/30/08
T32530.08.10 ASTM D1970 08/17/10
T33190.08.10 TAS 103 08/06/10
T37610.07.11 TAS 114-D 07/29/11
IRT-Arcon IRT07-0006 ASTM D1970 07/11/07
IRT 07-0036 ASTM D1970 02/22/08
IRT08-0002 ASTM D 1970 02/22/08
I
I
NOA No.: 11-0912.04
Expiration Date: 01/25/17
MIAMI•DADECOUNTY Approval Date: 01/19/12
Page 3 of 10
� li
i
I
y»i jA F
Ir
�RO
GENERAL LIMITATIONS—30#ASTM SPECIFICATION FELT:
1. Fire classification is not art of this acceptance;refer to a current A roved Roofing
p p pp a Materials
Directory for fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum del k requirements shall be in
compliance with applicable building code.
3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance
listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance.
4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9N-3 of the Florida Administrative Code_
INSTALLATION REQUIREMENTS—30#ASTM SPECIFICATION FELT:
1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Buildinar Codes.
2. Observe and comply with roofing practices and guidelines as i,outlined by the National Roofing
Contractors Associations(NRCA)when installing 309 Felt.
3. During installation of 304 Felt, comply with Occupational Safety and Health Administration(OSHA)
safety standards;use common sense measures and adequate safety precautions to prevent accidents.
4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion
and fastened as required by applicable system assemblies NOA or applicable Building Code.
I
GENERAL LIMITATIONS-EASYLAY:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials
Directory for fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in
compliance with applicable building code.
3. EasyLay shall be applied to a clean and dry'surface.
4. EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for
additional information.
5. EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather
resistant covering. In general,on slopes less than 4:12, a double layer of EasyLay is recommended.
Double layer application is best achieved by using 19"side laps,making sure the side laps are `shingled
in' to shed water.
6. When installing EasyLay,the roof system must include proper ventilation.
7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay
with specific prepared roofing products. EasyLay may be used with any approved;roof covering Notice
of Acceptance listing ASTM D 226 Type 11 felt as a component part of an assembly in the Notice.of
Acceptance. 1
8. All products lined herein shall have a quality assurance audit in accordance with ithe Florida Building
Code and Rule 9N-3 of the Florida Administrative Code.
9. EasyLay shall not be left exposed for longer than 30 days after application.
10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the
preceding maximum time limitations.
NOA 'o.. 11-0912.04
MIAMMADE C
Expiration Date: 01/25/17
�UI•••. OUNTY Approval Date: 01/19/12
Page 4 of 10
I �
'I I
I
cop
APPROVED ASSEMBLIES-EASYLAY:
I
System E(1): Anchor sheet mechanically fastened to deck,
I
Deck Type 1: Wood,Non-Insulated.
Deck Description: Minimum 19/32"plywood or wood plank.
Anchor/Base Sheet: One or more plies of EasyLay underlayment,with a minimum 4"wide side lap and a
minimum 8"wide end lap,mechanically fastened to deck. 1
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered
rows 12"o.c.in the field(for Anchor/Base sheet).
Surfacing: Approved Roof Assemblies in lieu of FBC perseribed ASTM D 226 Type II felt.
i
INSTALLATION REQUIREMENTS EASYLAY:
I. EasyLay shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing
Contractors Associations(NRCA)when installing EasyLay. I
3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety
standards;use common sense measures and adequate safety precautions to prevent accidents.
4• EasyLay shall be acceptable for, use with asphaltic shingles,wood shakes and shingles,quarry slate,
the and metal roofing assemblies:
5 Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of
EasyLay.
6. Place a full width piece of EasyLay,parallel to the eave(low)edge of the roof.
7. Unroll EasyLay 2 to 3 feet,with the lay lines facing up,and position the end of it to the edge of the
eave and rake.
8. Install a few fasteners at the top,near the rake,and roll out the sheet to a maneag1 length.
9. Pull,straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the
eave edge.
10. EasyLay shall be fastened with approved roofing nails and tincaps,or approved capnails,driven by
hand or pneumatically,spaced 6"o.c.at all laps in the center of the seam area,and two staggered rows
fastened 12"o'.c.in the field of the sheet.
11. When installing nails,apply so that the head of the nail is flush with the EasyLay,surface,without
cutting into the EasyLay surface.
12. Fastening shall be done from the top to-avoid walking or kneeling on unsecured�heet.
13. Continue on to the end of the substrate and fasten down.
14. Align the next roll over the preceding sheet so as to form a minimum 4"overlap.
15. Then install the just placed sheet,per instructions above. f i
16. The bottom of the second course of EasyLay shall lay on top of the first course so that any water will
flow over the top of EasyLay.
NOA No.: 11-0912.04
MIAMFDADE COU Expiratio� n Date: 01/25/17
NTY
Approval Date: 01/19/12
Page 5 of 10
I �
A
I
17. Apply subsequent sheets in the same manner,with 4"side laps and 6"end laps over the preceding
sheets.
18. When the top course is reached,lap about 6"of EasyLay over the
,rid-e.
19. Install EasyLay a minimum of 6"-up-any vertical surfaces. 1
20. Stagger the end laps a minimum of I 8"fromthe preceding course.
21. After installing EasyLay on the field of the roof.,install drip edge at the eaves(ifl used).
22. When applying EasyLay in the valley,start at the low point and work
ork to the high point,rolling the
1
membrane from the center outward in each direction. Make sure there are no nips or large wrinkles in
• the EasyLay.
23. Before applying,horizontal sections of EasyLay,install a vertical 11 ngth of EasyLay down the center of
the valley.
24. Several sections of EasyLay can be used,but be certain to overlap the higher sections several inches so
any water will flow over the top of the sheet.
25. EasyLay underlayment in the valley areas must be covered with code prescribed'metal or other
approved valley lining material.
26. Apply a minimum 1/16"thick uniform layer of SBS trowel grade modified flashing cement to water
1. 1 Z'
proof areas of EasyLay where any cuts or tears have occurred. Seams or joints may require the
application of an SBS trowel grade modified flashing cement.
27. Flash vent pipes,stacks, compli-
chinineY s and penetrations in I compliance iwith Roof Asiembly current
Product Control Notice of Acceptance and applicable Building Code. i
i I
GENERAL LIMITATIONS—TARco SELF ADHERED UNDERILAYMENTS�:
I
1. Fire classification is not part of this acceptance; refer to a current Approved Rooting Materials
Directory for fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in
compliance with applicable building code.
3. Tarco self adhering underlayments shall be applied only when mat el rial interface temperatures are 400 F
and rising.
4. Tarco self adhered underlayments shall not be installed when any form of moisture such as water,dew,
rain,etc. is present on the substrate.
5. Tarco self adhered underlayments are to be applied to a smooth, clean and dry surface, with the deck
free from irregularities.
6. Ensure roof has positive drainage prior to installation of Tarco self adhered underfayments.
7. Tarco self adhered underlayments shall not be applied over a pre-existing roof membrane or system.
8. i
After installation of Tarco self adhered membranes,wait a minimum of 48 hours before roof loading of
tiles.
9. Care should be taken during the loading procedure to keep foot
dropping the roof covering directly on the underlayment. traffic to a minimum and. avoid
NOA No.: 11-0912.04
1
Expiration Date: 01/25117
M L A M D A D E C 0)U=NT Y I
• Approv,41 Date: 01/19/12
Page 6 of 10
copy
10 All tiles shall be staged(two tiles perpendicular to slope,four tiles,on top parallel to slope)as per
manufacturer's requirements,not to exceed 6-high,to the standard maximum roof pitch of 6:12 for flat
tiles and 6 :12 for lugged tiles(See Tile Staging Method diagram below).
At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to
load the roof tile.
Tile Staain Method
...^•,^-' "`. ,nlr✓�-' "�'�,_" 'R3x s- ,-fs-}'� • pro- xt,
��.,,"»"r✓ r"5^r '� ` 4 �. WON-
4` ,� ,.g,� a {rd rt�
� x'� P, '.,F.'.:+rn���, s e � .�y. �,#1' �-•f.�.p���'�„n^�,- �"^"` ., t�}t" X �We'"v"'sd
'a KF
.s L""/'"a5; ..e �' .,,,,, —w=x::k .,pYw.�m.a. q�„� 6� T���•
Slope
Front View-Staged Tiles Side View-Staged Tiles
11. The manufacturer reserves the right to change the tile staging method at any time.as well as the number
of tiles stacked, not to exceed the preceding maximum number of tiles limitation.'
12. EasyLay, PS200"'. MS300, SS400, and NR500Kr shall not be left exposed as,a temporary roof for
longer than 3.0 days after application. PS200"T shall not be left exposed as a temporary roof for longer
than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180
days after application. The manufacturer reserves the right to change product exposure period at any
time;not to exceed the preceding maximum time limitations.
13. NR500Xr is not recommended for extreme high temperature environments such as under copper or zinc
metal roofing.
14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco self adhered underlayments may be used
with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or
the ASTM standard which the self adhering underlayments meet as,a component part of an assembly in
the Notice of Acceptance.
If Tarco self adhered underlayments or the ASTM standards are not listed,a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for
approval provided that appropriate documentation is provided to detail compatibility of the product,
wind uplift resistance,and fire testing results.
15. All products lised herein shall have a quality assurance audit in accordance with!the Florida Building
Code and Rule 9N-3 of the Florida Administrative Code.
NOA No.: 11-0912.04
Expiration Date: 01/25/17
MAMNDADE COUNTY Approval Date: 01/19/12
Page 7 of 10
l
PY_
APPROVED ASSEMBLIES—TARCO SELF ADHERED UNDERLAYMENTS
I
i
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Deck Type 1: Wood,Non-Insulated.
Deck Description: Minimum 19/32"plywood,,wood plank..
Anchor/Base Sheet: One or more plies of ASTM D226 Type II,ASTM D2626,or EasyLay underlayment,
with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically
fastened to deck.
Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows
12"o.c. in the field(for Anchor/Base sheet only).
Membrane: All Tarco self adhered membranes applied to approved Anchor/Base Sheet.
(See 7'r15 below for back nailing) j
Surfacing: Approved Roof Assemblies as specified below.
System F(1): Membrane self-adhered to concrete deck.
Deck Type 3: Concrete,Non-Insulated.
Deck Description: Structural concrete or concrete plank min.2500 psi.
Deck Preperation: The concrete deck shall be clean and dry and cured for a minimum of 28 days.
Anchor/Base Sheet: None
Fastening: Membrane shall be back nailed with approved concrete fasteners and 15/8"approved
tin caps at a maximum spacing of 9"o.c.at the head laps and be covered by the
preceding layer.No back nail fasteners or tin caps shall remain exposed.
Membrane: Tarco PS20e self adhered membrane applied directly to concrete deck.
(See Fastening above for back nailing)
Surfacing: Approved Roof Assemblies as specified below. i
I
INSTALLATION REQUIREMENTS—TARCO SELF ADHERED UNDERLAYMENTS:
I. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building
Codes.
2_ Observe and comply with roofing practices and guidelines as loutlined by the National Roofing
Contractors Associations(NRCA)when installing Tarco self adhering underlayments.
3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety
standards;use common sense measures and adequate safety precautions to prevent accidents.
4. Fast90 and PS200 shall be acceptable underlayments for mechanically fastened roof tile and adhered
roof the applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles,
wood shakes and shingles, and slate or simulated slate roof assemblies. PS200'i°and NR5008T shall
be acceptable underlayments for asphaltic shingles, wood shakes, shingles, and metal roof panel
assemblies.
5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of the
Tarco self adhering underlayments.
6. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane.
NOAINo.: 11-0912.04
MIAMI•DADE C OUNTY
Expiration Date: 01/25/17
Approval Dater 01/19/12
Page 8 of 10
i
ILEair <'f
7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the
application of the Tarco self adhering underlayments. Refer' applicable building codes prior to
installation to verify acceptable substrates.
8. Prime all metal collars,flashing,valleys,liner,drip edge and concrete deck substrate with ASTM D 41
primer,water based acrylic or water based polymer modified primer.
9. Contractor may cut the underlayments into sections for workability and allow to relax prior to
application. I
10. Place the underlayments over metal drip edge in accordance with RAS 111.
11. Install the first course of underlayment parallel to the eave edge.
+ 12. Apply the underlayment,working from the center of the material continuously tb the ends of the sheet
(half of the length of the sheet is the center);taking care to avoid wrinkles and ridges.
13. ReMove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive
side of the membrane does not adhere to its self. In the.event this transpires,separate the two layers
immediately. After some time,it may become impossible to do so(without damaging the material.
14. It is.recommended that end laps be staggered a minimum of 18"from the precedi n1g course.
15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 I guage 1`/d" approved
ring shank type applied with a minimum of a 15/$" approved tin cap or approved capnail as required
per the High Velocity Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 9"o.c. The
head lap of the preceding layer of underlayment.is to cover the area being back nailed.
16. RoII or broom the entire membrane surface paying special attention to all overlap areas"side laps,end
laps, T joints" to ensure adhesion with acceptable substrates. A minimum of a 128 lb weighted roller
may be used for steep slope applications. The use of a soft bristled push broom is acceptable on
steeper slopes. The above mentioned procedures are necessary in order to apply',,uniform pressure and
allow for contact of the membranes. 1 1
17. Apply '/8" thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive / flashing
cement throughout the contact area of the 6" granule over granule and fabric over fabric end laps.
Once the aforementioned procedure has been completed, the membrane must then be hand rolled in
place in order to ensure contact of membrane and achieve a minimum of 1/8t'" asphaltic bleed out in
designated area. i
18. Tarco self adhering underlayments shall be applied to protrusions,;slope changes, valleys, curbs, and
other roof top penetrations before any other sections of the roof.
-19. When applying underlayments in the valley, start at.the low point land work to the high point,rolling
the membrane from the center outward in each direction.
20. For ridge applications,center the underlayment and roll from the'center outward in both directions.
21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
22. All protrusions or drains shall be initially taped with a 6" piece of like kind membrane. The flashing
tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of
like kind membrane.shall be applied over the flashing detail:
23. Vertical strapping of Tarco self adhering membranes is acceptable.
I I
NOA No.: 11-0912.04
Expiration Date: 01/25/17
MlAM1•DADE COUNTY
.••• ApprovaliDate: 01/10/12
Page 9 of 10
I
' I
I �
I.
ki
MANUFACTURER'S CONSIDERATIONS:
1. Fast90, PS200H7, PS200mul MS300, SS400, NR500"'T can be directly adhered to wood decks. Ensure
that such application is in compliance with applicable Building Code.
2. For best results when adhering Fast90, PS200"" PS200"'u MS300, SS400, NIRSOOT directly to wood
decks, surface may be primed with an ASTM D41 asphalt primer, water based lacrylic or water based.
polymer modified primer.
When using primer, follow the manufacturer's recommendation for 'cure time.' ;prior to application of
Fast90,PS200"T,PS200m MS300, SS400,NR500HT
Cr
3. When using
Fast90 and PS200"7in tile roofing applications,use of loading,battens or toe boards on roof
slopes greater than 6:12 and higrher is recommended.
4. Code body requirements supersede manufacturer's recommendations and installation guidelines.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following-
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to.properly
evaluate the installation of these materials.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami-Dade County Product Control Approved" or they Miami-Dade County I
Product Control Seal as shown below.
MAMMADE COUNTY11
END OF THIS ACCEPTANCE
NOA No.: 11-0912.04
ML"AALMI-D�ADDE UNTY Expiradoh,Date: 01/25/17
Approval Date: 01/19/12