Loading...
HomeMy WebLinkAboutHealth Department Septic Approval RECEIVED � MAR Q 6 1018 Permitting Department o1F�� St.Lucie county j APPLICATION #:AP1284485 tr �` STATE OF FLORIDA PERMIT #:56-SF-1752826 DEPARTMENT OF HEALTH DOCUMENT #:FI"1160938 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 'CONSTRUCTION INSPECTION AND FINAL APPROVAL, DATE PAID:04/O5/2017 FEE 'PAID':515.0G RECEIPT #::5.6-PID-K09900 APPLICANT: La Pontecia II LLC(House) AGENT: Pro Tech Professional Services PROPERTY ADDRESS: 16675 C24.Canal' Rd Fort Pierce, FL 34946 LOT: BLOCK: SUBDIVISION:. ID#: .3224-111-0002-000-2 CHECKED [X] ITEMS :ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST: BE !CORRECTED. i TANK INSTALLATION. SETBACKS { [ ] [01] TANK SIZE [11 2000.00 [21 1050:00: [; ] [97]' SURFACE WATER 100 FT [ ] [02] TANK 'MATERIAL Concrete [ ] [28] DITCHES 100 FT ( .] [031 OUTLET DEVICE [ ] [201 PRIVATE WELLS 100 FT [ ] '[04] MULTI-CHAMBERED { Y N' ] [ ] [30]; PUBLIC.WELLS FT [ ] [051 OUTLET FILTER Polylok PL-122 [ ] [311: IRRIGATION WELLS 100 FT' [' ] [06] LEGEND 1, 01-011-37DC3 2, .01.-011-09SC3 [ ] [32] POTABLE WATER 1.00 FT [ ] [07] WATERTIGHT [ j [331 BUILDING FOUNDATIONS. 7 FT [ ] C-081 LEVEL [ 1 [34] PROPERTY LINES 100 FT [ ] [09] DEPTH TO LID [ ] [35,] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 600 [21 600. SQFT [ ] [361 DRAINFIELD COVER [ ] [11.] DISTRIBUTION BOX HEADER X [: ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1„ 5.00 2. 5 [ ] [38] SLOPES: r [ ] [.13.] DRAINLINE SEPARATION [ j 1391 STABILIZATION 03/05/2018 [ ] [14] DRAINLINE SLOPE ( ] [15] DEPTH OF COVER, ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / HELOW ]Bit 24.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION ( ,] [41] STORMWATER RUNOFF [ ] [:18,] DOSING PUMPS. 1.W_ .[ ] (421 ALARMS [. ] [19] AGGREGATE SIZE [ .] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE .FINES [ ] [44] BUILDING AREA 1 ] [21] AGGREGATE DEPTH. [ ]. [451 LOCATION CONFORMS WITH SITE PLAN FILL _/ EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [4.7.1 CONTRACTOR David C Whiteside-,(Accurite S- [ ] [231 FILL TEXTURE [ ] ['48] OTHER. INFILTRATOR Quick4 E036(single c [ ], [241 EXCAVATION'DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] (261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & 'TILLED Comments: Comments are on page 2. i CONSTRUCTION [ APPROVED / .�a -►�, /�Qtii F�.f� St.Lucie CHD DATE: 1:0/20/2017 DISAPPROVED ]' ,Environmental Specialist) rian J Ingram-(ENVIRONMENTAL HEALTH) I FINAL SYSTEM [ AP,PROVED / '7 ,�,, ,y .St.Lucie CHD DATE.: 03/05/2018 DISAP,PROVEEk Environmental Speciali I Dianna S May(Florida Department of Health '(Explanation of Violations on following page) DH' .4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E=6.003, FAC Page 2 of 3 El-I Database v 1:0.1 AP1284485, EI1)1752j* I APPLICATIO_i #:AP'1284485 t STATE OF FLORIDA PERMIT #.56-SF-1752826. •� DEPARTMENT of HEALTH DOCUMENT #:F11160938 c 'ti'b ONSITE SEWAGE TREATMENT AND DISPOSAL, SYSTEM CONSTRUCTION _INSPECTION AND FINAL APPROVAL DATE P Tn:04105/2017 FEE PAID•515.00... RECEIPT #.56-PID-3209900 Violation Number Comment. Comments The system'is'sized:for 5 bedrooms with.a maximum occupancy of 10 persons(2 per bedroom),for a total estimated:flow of 940 gpd.New ST,DT,and 2x600sgff DFs installed. Each DF=5x10 chambers long.Liberty.1/3hp pump. No violations,.system ok toacover.Contractor notified onsite.Needs final inspection for mound system,alarm check,and final grading,: Final inspection ok,no violations observed;Emailed to building depaitmenfand contractor. i ' I I DH 4016, 08/09 (Obsoletes all previous :editions. which may not be .used) Incorporated: 64E-6,003,. FAC Page 2' of 3. EH Databaso v'1:0.1 AP1284485 EID1762826