Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's r Pep Us FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method I i Project Name: CESPEDES(MAIN HOUSE) Builder Name: PROTECH PROFESSIONAL SERVICE Street: 16675 C-24 CANAL RD Permit Office: ST LUCIE COUNTY City,State,Zip: SAINT LUCIE CO,FL, Permit Number:1704'0601 Design Location: FL,Fort Pierce Jurisdiction: 661000 Cond.Floor Area:: 7541 sq.ft. Cond.Volume: 82800 cu ft. I Envelope Leakage Test Results Leakage Characteristics Regression Data: i C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA: 1 Pa cfm EgLA: 2 Pa cfm AGH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA: 6 Pa cfm I R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.,A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; i 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be cldsed but not sealed beyond intended infiltration P 9 P P Y control measures; i 3. Interior doors,if installed at the time of the test,shall be open, 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, I 0�� STATE performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third party.A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party conducting the test and provided to SIGNATURE: the code official. PRINTED NAME: BUILDING OFFICIAL: DATE: Py DATE: i i 7/3/2017 2:15 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software I Page 1 of 1 I FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCEIINDEX* 73 The lower the EnergyPerformance Index,the more efficient the home. 16675 C-24 CANAL RD, SAINT LUCIE CO, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block Int Insul,Exterior R=4.1 7414.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 6 d.N/A I R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Cathedral/Single Assembly(Unvented)R=22.0 5271.00 ft2 6. Conditioned floor area(ft2) 7541 b.N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.10 880.00 ft2 11.Ducts R ft2 a.Sup:Main,Ret:Main,AH:Main 6 1200 SHGC: SHGC=0.18 b. U-Factor: Sgl, U=1.07 311.00 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.99 237.75 ft2 a.Central Unit 214.0 SEER:16.73 SHGC: SHGC=0.27 d. U-Factor: other(see details) 95.50 ft2 SHGC: other(see details) 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.180 ft. a.Electric Heat Pump 207.0 HSPF:9.00, Area Weighted Average SHGC: 0.224 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 5271.00 ft2 a.Propane EF:0.8 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat J I certify that this home has complied with the Florida Energy Efficiency Code for Building JgE ST Construction through the above energy saving features which will be installed (or exceeded) y0old 6 = 9pA0 in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code cotuqliant features. r~ Builder Signature: Date: 61-4J/r 7 c� a Address of New Home: `G G 7 f ��2fr CCa l i2� City/FL Zip: ,, 5,�}„�,,� �e oD we *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Buildii g Commission's support staff. i *"Label-required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/3/2017 2:15 PM= EnergyGauge(D USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 y FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: CESPEDES(MAIN HOUSE) Builder Name: PROTECH PROFESSIONAL SERVICE Street: 16675 C-24 CANAL RD Permit Office: ST LUCIE COUNTY City,State,Zip: SAINT LUCIE CO,FL, Permit Number:170410601 Owner: CESPEDES Jurisdiction: 661000 Design Location: FL,Fort Pierce County:: St.Lucie(Florida Cli late Zone 2) I ! 1. New construction or existing New(From Plans) 9. Wall Types(7414.0 sgftJ Insulation Area 2. Single family or multiple family Single-family a.Concrete Block Int Insul, Exterior R=4.1 7414.00 ft2 b.N/A R= ftz 3. Number of units,if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 6 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types (5271.0 sqft.) Insulation Area a.Cathedral/Single Assembly(Unvented)R=22.0 5271.00 ftz 6. Conditioned floor area above grade(ftz) 7541 b. N/A R= ftz _ z Conditioned floor area below grade(ftz) 0 11 c RDuc s R ft z 7. Windows(1524.3 sqft.) Description Area a.Sup:Main, Ret:iMain,AH:Main 6 1200 a. U-Factor: Sgl, U=1.10 880.00 ftz 1 SHGC: SHGC=0.18 b. U-Factor: Sgl, U=1.07 311.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 214.0 SEER:16.73 c. U-Factor: Sgl, U=0.99 237.75 ftz a SHGC: SHGC=0.27 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 95.50 ftz a.Electric Heat Pump 207.0 HSPF:9.00 SHGC: other(see details) Area Weighted Average Overhang Depth: 2.180 ft. j Area Weighted Average SHGC: 0.224 14.Hot water systems 8. Floor Types (5271.0 sqft.) Insulation Area a.Propane Tankless Cap:1 gallons EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 5271.00 ftz b. Conservation features ! b.N/A R= ftz None � c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 171.06 Glass/Floor Area: 0.202 PASS Total Baseline Loads: 235.01 I hereby certify that the plans and specifications covered by Review of the plans and ��TI;E ST.g7, this calculation are in compliance with the Florida Energy specifications covered by this _ ,gyp Code. calculation indicates compliance with the Florida Energ y Code. PREPARED BY. Before construction is completed r ' DATE: :7 / :1 /1777 this building will be inspected for c� y compliance with Section 553.908 * "' I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. J illfre � OWNER/AGENT: BUILDING OFFICIAL: DATE: �T�;_�i DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402 4.1.1 and an envelope leakage test report in-accordance with R402.4.1.2. 7 /L01Y2 `FM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: CESPEDES(MAIN HOUSE) Bedrooms: 6 Address Type: Street Address Building Type: User Conditioned Area: 7541 Lot# Owner: CESPEDES Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBookl Builder Name: PROTECH PROFESSIONAL Rotate Angle: 0 Street: 16675 C-24 CANAL RD Permit Office: ST LUCIE COUNTY Cross Ventilation: County: St.Lucie Jurisdiction: 661000 Whole House Fan: City,State,Zip: SAINT LUCIE CO, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: j I j CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low j BLOCKS Number Name Area Volume 1 Blockl 7541 82800.2 j SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 7541 82800.2 Yes 1 6 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 389 ft 0 5271 ftz ---i 0 0 1 ROOF I Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i 1 Gable or shed Metal 5709 ftz 1098 ftz Medium O I96 No ' 0.9 No 22 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 No attic Unvented 0 5271 ft2' N i N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Cathedral/Single Assembly(Unvented Main 22 Blown 5271 ftz 0.11 Wood I i I 7/3/2017 2:14 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 I FORM R405-2014 WALLS Adjacent S Pace Cavity Width Height Sheathing Framing Solar Below # nrnt To Wall Type Ft 1 N Exterior Concrete Block-Int Insul Main 4.0999 168 6 11 1853.5 ft2 0 0.150000 0 2 S Exterior Concrete Block-Int Insul Main 4.0999 168 6 11 1853.5 ft2 0 0.150000 0 3 E Exterior Concrete Block-Int Insul Main 4.0999 168 6 11 1853.5 ft2 0 0.150000 0 4 W Exterior Concrete Block-Int Insul Main 4.0999 168 6 11 1853.5 ft2 i 0 0.150000 0 DOORS I # Ornt Door Type Space Storms U-Value Width Height Area Ft j In Ft In 1 W Insulated Main None .46 3 8 24 ft2 i 2 S Insulated Main None .46 3 8 24 ft2 I 3 N Insulated Main None .46 3 8 24 ft2 4 E Insulated Main None .46 3 8 24 ft2 5 N Insulated Main None .46 3 8 24 ft2 6 E Insulated Main None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single(Tinted) Yes 1.1 0.18 200.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 2 N 1 Metal Single(Tinted) Yes 1.1 0.18 100.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 3 N 1 Metal Single(Tinted) Yes 0.98 0.27 4.0 T1 2 ft 0 in 1 ft 0 in Drapes/blinds None 4 N 1 Metal Single(Tinted) Yes 0.98 0.27 4.0 ft2 2 ft 0 in 1 ft 0 In Drapes/blinds None 5 N 1 Metal Single(Tinted) Yes 0.98 0.27 4.0 ft2 2 ft 0 in 1 ift 0 in Drapes/blinds None 6 N 1 Metal Single(Tinted) Yes 0.99 0.32 10.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 7 N 1 Metal Single(Tinted) Yes 0.99 0.19 30.0 ft2 2 ft 0 in 3�ft 0 in Drapes/blinds None 8 N 1 Metal Single(Tinted) Yes 1.07 0.32 6.0 ft2 2 ft 0 in 3 ft 0 in Drapes/blinds None 9 N 1 Metal Single(Tinted) Yes 1.07 0.32 6.0 ft2 2 ft 0 in 3ft 0 in Drapes/blinds None 10 N 1 Metal Single(Tinted) Yes 1.07 0.32 8.0 ft2 2 ft 0 in 2 A 0 in Drapes/blinds None 11 S 2 Metal Single(Tinted) Yes 0.99 0.27 4.0 ft I 2 2 ft 0 in 5 ift 0 in Drapes/blinds None 12 S 2 Metal Single(Tinted) Yes 0.99 0.27 10.0 ft2 2 ft 0 in 5 ift 0 in Drapes/blinds None 13 S 2 Metal Single(Tinted) Yes 0.99 0.27 4.0 ft2 2 ft 0 in 5 jft 0 in Drapes/blinds None 14 S 2 Metal Single(Tinted) Yes 0.99 0.27 10.0 ft2 2 ft 0 in 5 ift 0 in Drapes/blinds None I 15 S 2 Metal Single(Tinted) Yes 0.99 0.19 18.042 3 ft 0 in 3ft 0 in Drapes/blinds None 16 S 2 Metal Single(Tinted) Yes 1.07 0.32 15.0 ft2 2 ft 0 in 15 ft 0 in Drapes/blinds None 17 S 2 Metal Single(Tinted) Yes 1.07 0.32 15.0 ft2 2 ft 0 in 15 ft 0 in Drapes/blinds None 18 S 2 Metal Single(Tinted) Yes 1.07 0.32 13.5 ft2 2 ft 0 in 7 ft 0 in Drapes/blinds None 19 S 2 Metal Single(Tinted) Yes 1.07 0.32 13.5 ft2 2 ft 0 in 71ft 0 in Drapes/blinds None i 20 S 2 Metal Single(Tinted) Yes 0.99 0.19 18.0 ft2 3 ft 0 in 31ft 0 in Drapes/blinds None 21 S 2 Metal Single(Tinted) Yes 0.99 0.27 9.0 ft2 2 ft 0 in 5 ft 0 in Drapes/blinds None 22 S 2 Metal Single(Tinted) Yes 1.07 0.32 18.0 ft2 2 ft 0 in 51ft 0 in Drapes/blinds None 23 S 2 Metal Single(Tinted) Yes 1.07 0.32 30.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds None 24 E 3 Metal Single(Tinted) Yes 0.99 0.27 22.5 ft2 2 ft 0 in 2 ft 6 in Drapes/blinds None 25 E 3 Metal Single(Tinted) Yes 0.99 0.27 9.0 ft2 2 ft 0 in 5 ft 0 in Drapes/blinds None I 7/3/2017 2:14 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I I FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Areal Depth Separation Int Shade Screening 26 E 3 Metal Single(Tinted) Yes 0.99 0.27 22.5 ft- 2 ft 0 in 2 ft 6 in Drapes/blinds None 27 E 3 Metal Single(Tinted) Yes 1.1 0.18 100.0 ft2 2 ft 0 in 2 ft 6 in Drapes/blinds None 28 E 3 Metal Single(Tinted) Yes 1.1 0.18 160.0 ftz 2 ft 0 in 2 ft 6 in Drapes/blinds None 29 E 3 Metal Single(Tinted) Yes 1.1 0.18 160.0 ft2 2 ft 0 in 2 ft 6 in Drapes/blinds None 30 E 3 Metal Single(Tinted) Yes 0.99 0.27 11.0 ftz 2 ft 0 in 1 ft 0 in Drapes/blinds None 31 E 3 Metal Single(Tinted) Yes 1.1 0.18 80.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds None 32 E 3 Metal Single(Tinted) Yes 0.99 0.27 12.0 ftz 2 ft 0 in 6 ft 0 in Drapes/blinds None 33 E 3 Metal Single(Tinted) Yes 0.99 0.27 48.0 ft2 2 ft 0 in 8 ft 0 in Drapes/blinds None 34 E 3 Metal Single(Tinted) Yes 0.99 0.27 12.0 ftz 2 ft 0 in 6 ft 0 in Drapes/blinds None I i 35 E 3 Metal Single(Tinted) Yes 1.1 0.18 80.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds None 36 W 4 Metal Single(Tinted) Yes 0.99 0.27 8.8 ft? 1 ft 6 in 2 ft 0 in Drapes/blinds None I I 37 W 4 Metal Single(Tinted) Yes 1.07 0.32 15.0 ft2 1 ft 6 in 5 ft 0 in Drapes/blinds None I 38 W 4 Metal Single(Tinted) Yes 1.07 0.32 30.0 ft2 1 ft 6 in 3 ft 0 in Drapes/blinds None 39 W 4 Metal Single(Tinted) Yes 0.99 0.27 4.0 ft2 12 ft 0 in 6 ft 0 in Drapes/blinds None 40 W 4 Metal Single(Tinted) Yes 1.07 0.32 12.0 ft2 12 ft 0 in 6 ft 0 in Drapes/blinds None 41 W 4 Metal Single(Tinted) Yes 0.99 0.27 4.0 ft2 12 ft 0 in 6 ft 0 in Drapes/blinds None 42 W 4 Metal Single(Tinted) Yes 1.07 0.32 12.0 ft2 12 ft 0 in 6 ft 0 in Drapes/blinds None 43 W 4 Metal Single(Tinted) Yes 1.07 0.32 12.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None i 44 W 4 Metal Single(Tinted) Yes 1.07 0.32 30.0 ft2 2 ft 0 in 3 ft 0 in Drapes/blinds None 45 W 4 Metal Single(Tinted) Yes 0.99 0.27 6.0 ft 2 ft 0 in 5 ft 0 in Drapes/blinds None 46 W 4 Metal Single(Tinted) Yes 1.07 0.32 15.0 ftz 2 ft 0 in 8 ft 0 in Drapes/blinds None 47 W 4 Metal Single(Tinted) Yes 0.99 0.27 9.0 ft2 1 ft 6 in 6 ft 0 in Drapes/blinds None 48 W 4 Metal Single(Tinted) Yes 1.07 0.32 15.0 ftz 1 ft 6 in 9 ft 0 in Drapes/blinds None 49 W 4 Metal Single(Tinted) Yes 0.99 0.27 6.0 ft2 2 ft 0 in 5 ft 0 in Drapes/blinds None 50 W 4 Metal Single(Tinted) Yes 1.07 0.32 15.0 ft2 1 ft 6 in 9 ift 0 in Drapes/blinds None 51 W 4 Metal Single(Tinted) Yes 0.99 0.07 7.5 ft2 1 ft 6 in 2,Ift 0 in Drapes/blinds None 52 W 4 Metal Single(Tinted) Yes 1.07 0.32 . 30.0 ft2 1 ft 6 in 2 ift 0 in Drapes/blinds None 53 W 4 Metal Single(Tinted) Yes 0.99 0.27 6.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None 54 W 4 Metal Single(Tinted) Yes 0.99 0.27 6.0 ft- 1 ft 6 in 2'ft 0 in Drapes/blinds None 55 W 4 Metal Single(Tinted) Yes 0.99 0.27 8.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 56 W 4 Metal Single(Tinted) Yes 0.99 0.27 6.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None INFILTRATION ,I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000279 5520 303.04 569.91 .2508 4 I i I i I i I 7/3/2017 2:14 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I i I FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Main 0.8 1 gal 90 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz I I DUCTS ----Supply---- ----Return---- Air CFM 25 ICFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Main 6 1200 ftz Main 80 ftz Default Leakage Main (Default) ((Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan [ ]Feb ]Mar r Ma [X]Jun X Jul rj Au Se Oct Nov Dec Heatin H Jan [X]Feb lX]Mar �Ap Ar May [ ]Jun I Jul AuJXJ SeP f Oct Nov X Dec Ventin [ Jan [ ]Feb X Mar Apr [ May [ ]Jun [ Jul Aug Se [ Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 781 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 I 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68' 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 . 68 68 68 66 66 I i I i I I i i I I ,I i i ' I 7/3/2017 2:14 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I � Project Name: CESPEDES(MAIN HOUSE) Builder Name: PROTECH PROFESSIONAL SERVICE Street: 16675 C-24 CANAL RD Permit Office: ST LUCIE COUNTY City,State,Zip: SAINT LUCIE CO,FL, Permit Number:1704-0601 Owner: CESPEDES Jurisdiction: 6I1000 Design Location: FL,Fort Pierce i COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material: Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with,the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. �. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier! Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms Ito the available cavity spaces. Garage separation Air sealing shall be provided between the garagel and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope' shall be air tight, IC rated, and sealed to the drywall. i Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms I o available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical for communical ion boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls Fireplaces shall have gasketed doors 7/3/2017 2:15 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 i FORM R405-2014 Florida Department of Business and Professiional Regulations Residential Whole BuildingPerformance and Prescri tive Methods ADDRESS: 16675 C-24 CANAL RD Permit Number:1704=0601 SAINT LUCIE CO,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that ani energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R4IO2.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified Is having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code off icial,Itesting shall be conducted by an approved third party.A written report of the results of the test shall be signed bylthe party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampens and outdoor combustion air. O R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior;wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the(heating load. ❑ R403.2.2 Sealing(Mandatory)NI1 ducts,air handlers,and filter boxes and building cavities that form the primary;air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an,energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,'including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. i 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 squ Ire feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. i Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. * Duct testing is not mandatory for buildings complying by Section R405 of this code. 7/3/2017 2:15 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 1 i r. FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 1050F(41°C) or below 550F(13°C)shall be insulated to a minimum of R-3., I R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with in automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters notequipped with inte integral heat traps and havin vertical pipe risers shall have P ( Y) 99 P g P P heat traps installed on both the inlets and outlets.External heat traps shall consist of either,a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intel nded use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60oC). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions!for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot'water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISOI Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;an Ji 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. I i Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. I I I i 7/3/2017 2:15 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 ;'I f i _ I FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) j O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity lis a nominal, rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in'an unconditioned space. Exceptions: j 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall'be sized within 14 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. i ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems, supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. j ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. I O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. • R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. ,Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a�minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 7/3/2017 2:15 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3