Energy Calculation Form & Manual J's (2)
Load Short Form ob: CESPEDES1 - - wrightsoft" ate: 4116117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I Project Information For: CESPEDES(AC#1) C-24 CANAL RD ST LUCIE CO FL Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 28 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gr/lb) 1 61 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-4821JA Cond RP1748AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 10.0 kW Sensible cooling 33840 Btuh Heating output 48000 Btuh Latent cooling 13160 Btuh Temperature rise 27 OF Total cooling 47000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 I ROOM NAME Area Htg load Clg load HtgJAVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) AC#1 1614 28938 35747 1600 1600 I Entire House d 1614 28938 35747 1600 1600 Other equip loads 0 I 0 Equip. @ 1.00 RSM 35747 Latent cooling 8466 TOTALS I 1614 I 28938 I 44213 I 1600 I 1600 FILE Y Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,�, +Wrightsoft° Right-Suite®Universal 2015 15.0.23 RSU18185 2017-Apr-18 11:23:08 Page 1 Arm ...sers\Owner\Desktop\Heat Loads\CESPEDESHTLD1.rup Calc=MJB Front Door faces: N Job: CESPEDES1 +�- wrightsoft Building Analysis 1 Date: 4116117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project Information For: CESPEDES(AC#1) C-24 CANAL RD, ST LUCIE CO, FL j 1 Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (°F) 70 75 Elevation: 25 ft Design TD (°F) j 30 50 Latitude: 270N Relative humidity(o Outdoor: Heating Cooling Moisture difference(gr/lb) 1.1 61.5 Dry bulb(OF) 42 90 Infiltration: Dailyrange(°F) - 15 ( L ) Method j Simplified Wet bulb(OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 I I • I Component Btuh/ftZ Btuh %of load Walls 4.0 4617 16.0 W Glazing 35.6 13051 45.1 Doors 0 0 0 Ceilings 0.9 1446 5.0 Floors 1.4 2271 7.8 Infiltration 3.2 4924 17.0 Ducts 2631 9.1 Piping 0 0 Humidification 0 0 Ventilation 0 0 G Adjustments 0 Total 28938 100.0 I Component Btuh/ftZ Btuh %of load Wa Walls 2.5 2935 8.2 Glazing 58.5 21472 60.1 Doors 0 0 0 Ceilings 2.3 3744 10.5 Floors 0 0 0 /,�'. Infiltration 1.6 2473 6.9 Ducts 4663 13.0 Ventilation 0 0 I Internal gains 460 1.3 Blower 0 0 Adjustments 0 Gma", Total 36747 100.0 I Latent Cooling Load=8466 Btuh Overall U-value=0.161 Btuh/ftZ°F Data entries checked. .` Wtl �1tSQ ' 2017-Apr-1 8 11:23:08 g Right-Suitee Universal 2015 15.0.23 RSU18185 Page 1 ...sers\OwneADesktop\Heat Loads\CESPEDESHTLD1.rup Calc=MJS Front Door faces: N I i I Job C S1 wrightsoft Project Summary Date: 4116117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project • • For: CESPEDES(AC#1) C-24 CANAL RD, ST LUCIE CO, FL Notes: AC#1 HEAT PUMP MASTER SUITE Desiqn Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26308 Btuh Structure 31084 Btuh Ducts 2631 Btuh Ducts 4663 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28938 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 35747 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 6666 Btuh Ducts 1800 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 1614 1614 Equipment latent load 8466 Btuh Volume(f?) 12912 12912 Air changes/hour 0.74 0.70 Equipment total load 44213 Btuh Equiv.AVF(cfm) 160 150 Req.total capacity at 0.72 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-4821JA Cond RP1748AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 10.0 kW Sensible cooling 33840 Btuh Heating output 48000 Btuh Latent cooling 13160 Btuh Temperature rise 27 OF Total cooling 47000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-18 11:23:08 -F� wrightsoft' Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 ..sers\OwnerlDesktop\Heat Loads\CESPEDESHTLD1.rup Cale=MJ8 Front Door faces: N d a Load Short Form Job: CESPEDES2 + - wrightsoft Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project • • For: CESPEDES(AC#2) C-24 CANAL RD, ST LUCIE CO, FL I I Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db(°F) 70 75 Construction quality j Average Design TD(°F) 28 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gr/lb) 1 61 i HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-4821JA Cond RP1'748AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 10.0 kW Sensible cooling' 33840 Btuh Heating output 48000 Btuh Latent cooling 13160 Btuh Temperature rise 27 OF Total cooling 47000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure ressure 0.50 in H2O Static p 0.50 in H2O I Space thermostat Load sensible heat ratio 0.80 I � ROOM NAME Area Htg load Clg load HtgIAVF Clg AVF (ftz) (Btuh) (Btuh) (cfrn) (cfm) AC#2 2432 30072 36515 1600 1600 Entire House d 2432 30072 36515 1600 1600 Other equip loads 0 I 0 Equip. @ 1.00 RSM 36515 Latent cooling 8884 TOTALS 1 2432 1 30072 1 45399 1 i 1600 I 1600 I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-18 11:26:03 wrightSOW Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 BUK C:\Users\0wnerlDesktop\Heat Loads\CESPEDES2.rup Calc=MJ8 Front Door faces: N j I I BUI�C�In Analysis Job: CESPEDES2 + - wrightsoft° 9 yIS Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I i Project • • For: CESPEDES(AC#2) C-24 CANAL RD, ST LUCIE CO, FL Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature(°F) 70 75 Elevation: 25 ft Design TD(°F) 28 15 Latitude: 27°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 1.1 61.5 Dry bulb(°F) 42 90 Infiltration: Dailyrange(°F) - 15 ( L ) Method Simplified Wet bulb(OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btu hfiF Btuh %of load Walls 4.0 4857 16.2 Wd Glazing 35.6 10917 36.3 Doors 0 0 0 Ceilings 0.9 2179 7.2 j Floors 1.7 4154 13.8 Infiltration 3.4 5231 17.4 Ducts 2734 9.1 Piping 0 0 Humidification 0 0 Ventilation 0 0 GM„ Adjustments 0 Total 30072 100.0 Component Btuh/ft2 Btuh %of load Walls 2.5 3088 -8.5 Glazing 64.9 19925 54.6 Doors 0 0 0 Ceilings 2.3 5642 15.5 Floors 0 0 0 Infiltration 1.7 2638 7.2 Ducts 4763 13.0 Ventilation 0 0 Internal gains 460 1.3 Blower 0 0 Adjustments 0 Total 36515 100.0 Latent Cooling Load=8884 Btuh Overall U-value=0.124 Btuh/ft2-°F Data entries checked. 2017-Apr-18 11:26:03 t + wrightsOfV Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 C�►C:\Users\Owner\Desktop\Heat Loads\CESPEDES2.rup Calc=MJ8 Front Door faces: N Job - - c s2 wrightsoft- Project Summary Date: 4116/17 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I, I Project • • For: CESPEDES(AC#2) C-24 CANAL RD, ST LUCIE CO, FL Notes: AC#2 HEAT PUMP VIP SUITE Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Sum'mer Design Conditions o Outside db 42 F Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity] 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27338 Btuh Structure 31752 Btuh Ducts 2734 Btuh Ducts 4763 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30072 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 36515 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 7084 Btuh Ducts 1800 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 2432 2432 Equipment latent)load 8884 Btuh Volume(fl?) 24320 24320 Air changes/hour 0.42 0.39 Equipment total load 45399 Btuh Equiv.AVF(cfm) 170 160 Req.total capacity at 0.72 SHR 4.2 ton Heating Equipment Summary Cooling Equipment Summary Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-4821JA Cond RP1748AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 10.0 kW Sensible cooling 33840 Btuh Heating output 48000 Btuh Latent cooling 13160 Btuh Temperature rise 27 OF Total cooling 47000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Bold/Italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-18 11:26:03 t 4 wrightsoft' Right-Suite®Universal 2015 15.0.23 RSUIS185 Pagel ��c:\Users\Owner\Desktop\Heat Loads\CESPEDES2.rup Calc=MJS Front Door faces: N I a I Job: C Wrl htsoft° Load Short Form Date: 4/96 17DES3 9 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project Information For: CESPEDES(AC#3) C-24 CANAL RD, ST LUCIE CO, FL I i I Design Information Htg Clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces ! 0 Daily range - L 1 Inside humidity(%) 30 50 Moisture difference(gr/lb) 1 61 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-6021JA Cond RP1760AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 16 SEER Heating input 10.0 kW Sensible cooling ' 41760 Btuh Heating output 55000 Btuh Latent cooling 16240 Btuh Temperature rise 25 OF Total cooling 58000 Btuh Actual air flow 2000 cfm Actual air flow 2000 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure j 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (it2) (Btuh) (Btuh) (cfm) (cfm) AC#3 910 33084 44508 2000 2000 Entire House d 910 33084 44508 2000 2000 Other equip loads 0 1 0 Equip. @ 1.00 RSM 44508 Latent cooling 10484 TOTALS I 910 I 33084 I 54992 I 2000 I 2000 I 1 I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-18 11:32:50 .% + wrightSOW Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 Arm C:1Users\0wner\Desktop\Heat Loads\CESPEDES3.rup Calc=MJ8 Front Door faces: N I i I I I Building Analysis Job: CESPEDES3 - - wrightsof g y Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project For: CESPEDES(AC#3) C-24 CANAL RD, ST LUCIE CO, FL Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 ft Design TD(OF) 28 15 Latitude: 27°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 1.1 61.5 Dry bulb(OF) 42 90 Infiltration: Dailyrange(OF) - 15 ( L ) Method Simplified Mtbulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/fl? Btuh %of load w Walls 4.0 4336 13.1 Glazing 35.6 15540 47.0 Doors 0 0 0 Ceilings 0.9 815 2.5 f Floors 4.6 4154 12.6 Infiltration 3.4 5231 15.8 i Ducts 3008 9.1 n_ Piping 0 0 Humidification 0 0 Ghana �n„ Ventilation 0 0 Adjustments 0 Total 33084 100.0 Component Btuh/ft? Btuh %of load wall low Walls 2.5 2757 6.2 Glazing 66.1 28897 64.9 D-11 Doors 0 0 0 Ceilings 2.3 2111 4.7 ' Floors 0 0 0 '°as° Infiltration 1.7 2638 5.9 Ducts 5805 13.0 Ceilings Ventilation 0 0 Internal gains 2300 5.2 Blower 0 0 Adjustments 0 Glazing Total 1 1 44508 100.0 Latent Cooling Load= 10484 Btuh Overall U-value=0.266 Btuh/ft�°F WARNING:window to floor area ratio=48.0%-more than 25%. i .sty 2017-Apr-1811:32:60 'P wrlightsloft* Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 C:\Users\Owner\Desktop\Heat Loads\CESPEDES3.rup Cale=MJ8 Front Door faces: N Prot S Job: CESPEDES3 wrightsoft' Project Summary Date: 4111117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 h I Project • • For: CESPEDES(AC#3) C-24 CANAL RD, ST LUCIE CO, FL Notes: AC#3 HEAT PUMP OPEN LIVING---AREAS DESIGN PARTY Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 30076 Btuh Structure I 38703 Btuh Ducts 3008 Btuh Ducts 5805 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33084 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 44508 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 8684 Btuh Ducts 1800 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 910 910 Equipment latent load 10484 Btuh Volume(fly 9100 9100 Air changes/hour 1.12 1.05 Equipment total load 54992 Btuh Equiv.AVF (cfm) 170 160 Req.total capacity at 0.72 SHR 5.2 ton Heating Equipment Summary Cooling Equipment Summary Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-6021JA Cond RP1760AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 16 SEER Heating input 10.0 kW Sensible cooling 41760 Btuh Heating output 55000 Btuh Latent cooling 16240. Btuh Temperature rise 25 OF Total cooling 58000 Btuh Actual air flow 2000 cfm Actual air flow 2000 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Boldfitalic Values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2017-Apr-1811:32:50 g Right-Suite®Universal 2015 15.0.23 RSU18185 Pagel C:1Users\0wnerlDesktoplHeat Loads\CESPEDES3.rup Calc=MJ8 Front Door faces: N a Load Short Form Job: CESPEDES4 Wrightso Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project • • For: CESPEDES(AC#4) C-24 CANAL RD, ST LUCIE CO, FL I Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 28 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 1 Moisture difference(gr/lb) 1 61 I HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-2417JA Cond RP1724AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 5.0 kW Sensible cooling 1 17280 Btuh Heating output 23000 Btuh Latent cooling i 6720 Btuh Temperature rise 26 °F Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.72 I I ROOM NAME Area Htg load Clg load Htg!AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) AC#4 830 17385 16168 800 800 Entire House d 830 17385 16168 800 800 Other equip loads 0 1 0 Equip. @ 1.00 RSM 16168 j Latent cooling 6195 j TOTALS 1 830 1 17385 1 22363 1 800 1 800 I I I i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i 2017-Apr-1811:35:28 .� wrightsoft' Right-Suite®Universal 2015 15.0.23 RSU18185 page 1 AM C:\Users\Owner\Desktop\Heat Loads\CESPEDES4.rup Calc=MJ8 Front Door faces: N i i I Building Analysis Job: CESPEDES4 -�- wrightsoft 9 y Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 Project • • For: CESPEDES(AC#4) C-24 CANAL RD, ST LUCIE CO, FL Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature(-F) 70 75 Elevation: 25 ft Design TD (°F)! 28 15 Latitude: 27°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 1.1 61.5 Dry bulb(OF) 42 90 Infiltration: Dailyrange(OF) - 15 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/iI? Btuh %of load Walls 4.0 3095 17.8 wa Glazing 35.6 5227 30.1 Doors 0 0 0 , Ceilings 0.9 744 4.3 Floors 3.7 3046 17.5 Infiltration 4.0 3893 21.2 Ducts 1580 9.1 Piping 0 0 Humidification 0 0 , Ventilation 0 0 Adjustments 0 Total 1 1 173851 100.0 Component Btuh/ft2 Btuh %of load Walls 2.5 1988 12.2 Wall Glazing 50.8 7433 46.0 Doors 0 0 0 Ceilings 2.3 1926 11.9 <` Floors 0 0 0 Infiltration 2.0 1813 11.2 Ducts 2109 13.0 Ventilation 0 0 Internal gains 920 5.7 Blower 0 0 Glazing Ceilings Adjustments 0 Total 16168 100.0 Latent Cooling Load=6195 Btuh Overall U-value=0.168 Btuhffi°F Data entries checked. I 2017-Apr-1811:35:28 1 + wrightsoft• Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 C:\Users\Owner\Desktop\Heat Loads\CESPEDES4.rup Cale=MJ8 Front Door faces: N I Pro ect Summary Job: CESPEDES4 +�- wrightsoft ry Date: 4116117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project • • For: CESPEDES(AC#4) C-24 CANAL RD,ST LUCIE CO, FL Notes: AC#4 HEAT PUMP BED BTH 2-3 I Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Sum Imer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture differen ie 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15805 Btuh Structure 14059 Btuh Ducts 1580 Btuh Ducts 2109 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17385 Btuh Use manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load I 16168 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5395 Btuh Ducts 800 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 830 830 Equipment latent load 6195 Btuh Volume(ft3) 8300 8300 Air changes/hour 0.87 0.80 Equipment total load 22363 Btuh Equiv.AVF (cfm) 120 110 Req.total capacity at 0.72 SHR� 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF-2417JA Cond RP1724AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0.EER, 17 SEER Heating input 5.0 kW Sensible cooling 17280 Btuh Heating output 23000 Btuh Latent cooling 6720 Btuh Temperature rise 26 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0,049 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.72 Boldfitalic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofC 2017-Apr-1 B 11:age 1 f' � Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 C:\Users\ownerlDesktopXHeat Loads\CESPEDES4.rup Calc=MJ8 Front Door faces: N r I i Load Short F Job: CESPEDES5 +�- wrightsoft' Form Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS I 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I I Project • • For: CESPEDES(AC#5) C-24 CANAL RD, ST LUCIE CO, FL I I Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 28 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gr/lb) 1 61 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade Model RCF3617JA Cond RP1736AJ AHRI ref Coil AHRI ref j Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 7.5 kW Sensible cooling ! 25920 Btuh Heating output 35000 Btuh Latent cooling 10080 Btuh Temperature rise 27 OF Total cooling 1 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible he t ratio ! 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) I I AC#5 1285 21991 26761 1 1200 1200 Entire House d 1285 21991 26761 1200 1200 Other equip loads 0 1 0 Equip. @ 1.00 RSM 26761 Latent cooling 6213 TOTALS I 1285 I 21991 I 32974 I 1 1200 1200 I i I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-18 11:41:11 + wrightsoft' Right-Suite®Universal 2015 15.0.23 RSU18185 i Page 1 C:\Users\0wner\Desktop\Heat Loads\CESPEDES5.rup Calc=MJ8 Front Door faces: N i Building Analysis Job: CESPEDES5 - - wrightsoft' 9 y Date: 4/16117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I Project • • For: CESPEDES(AC#5) I C-24 CANAL RD, ST LUCIE CO, FL I' I I Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature(°F) 1 70 75 Elevation: 25 ft Design TD (°F)I 28 15 Latitude: 27°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 1.1 61.5 Dry bulb CF) 42 90 Infiltration: Dailyrange(OF) - 15 ( L ) Method Simplified Wet bulb(OF) - 78 Construction quality lAverage Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftz Btuh %of load Wa Walls 4.0 2655 12.1 Glazing 35.6 9139 41.6 Doors 0 0 0 , ^ Ceilings 0.9 1151 5.2 Floors 2.4 3046 13.9 Infiltration 4.3 4000 18.2 Ducts 1999 9.1 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 21991 100.0 Component Btuh/tz Btuh %of load Walls 2.5 1688 6.3 Glazing — 62.9 16163 60.4 Doors 0 0 0 Ceilings 2.3 2981 11.1 Floors 0 0 0 E. Infiltration 2.2 1978 7.4 Ducts 3491 13.0 Ventilation 0 0 Internal gains 460 1.7 Blower 0 0 Adjustments 0 Total 26761 100.0 i Latent Cooling Load=6213 Btuh Overall U-value=0.164 Btuh/ftz-°F Data entries checked. I I i 2017-Apr-18 11:41:11 fi r+-- wrilghtsoft• Right-Suite®Universal 2015 15.0.23 RSU18185 Page 1 C6dk C:\Users\Owner\Desktop\HeatLoads\CESPEDES5.rup Calc=MJB Front Door faces: N ` r - Project Summary Job: CESPEDES5 wrightsoft Date: 4116117 Entire House By: MIKEL ABBOTT ENERGY CALCS 4920 N DIXIE HWY,FT LAUDERDALE,FL 33334 Phone:954-776-2003 License:ENERGY RATER#37 I Project Information For: CESPEDES(AC#5) C-24 CANAL RD, ST LUCIE CO, FL Notes: AC#5 HEAT PUMP BED BTH/GAME CIGAR RM Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19991 Btuh Structure 23270 Btuh Ducts 1999 Btuh Ducts 3491 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21991 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26761 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5413 Btuh Ducts 800 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area ffl 1285 1285 Equipment latent load 6213 Btuh Volume(ft3) 12850 12850 1. Air changes/hour 0.61 0.56 Equipment total load 32974 Btuh Equiv.AVF(cfm) 130 120 Req.total capacity at 0.72 SHR 3.1 ton Heating Equipment Summary Cooping Equipment Summary Make RHEEM OR EQUAL Make RHEEM OR EQUAL Trade Trade 1' Model RCF3617JA Cond RP1736AJ AHRI ref Coil AHRI ref Efficiency 9 AFUE Efficiency 13.0 EER, 17 SEER Heating input 7.5 kW Sensible cooling 25920 Btuh Heating output 35000 Btuh Latent cooling 10080 Btuh Temperature rise 27 OF Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 8o(d�talic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WCif htsOft' 20r7-Apr-1811:41:11 g Right-Suite®Universal 2015 15.0.23 RSU18185 Pagel dOM C:\Users\Owner\Desktop\Heat Loads\CESPEDES5.rup Calc=MJB Front Door faces: N