Loading...
HomeMy WebLinkAboutRevisions; Update Location Plan, Remove F-2 from PlanOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # 2105-0507 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 . Y , (772) 462-1553 1. ! APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 5261 Deanna Ln, Fort Pierce, FL 34946 DETAILED DESCRIPTION OF PROJECT REVISIONS: (S1) Updated location plan, (S2/S3) Removed F-2 from plan/schedule/details, removed portions of new curb, updated structure width and post locations, updated connectors on plan and schedule, Resized beam/rafters revised spacing updated beam schedule, updated roof zone plan, updated elevations details to reflect wood member and connector changes. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNER/BUILDER INFORMATION: NAME: Marco Arita ADDRESS:5261 Deanna Ln CITY: Fort Pierce PHONE (DAYTIME: (954) 549-7499 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: MBV Engineering, Inc. A00RESS. 1835 20th St CITY: Vero Beach PHONE (DAYTIME): (772) 569-0035 SLCCC: 9123109 Revised 06130/17 ST. LUCIE CO CERT. #: FAX: FAX: ZIP: ZIP: 34946 STRUCTURAL -GENERAL NOTES DESIGN CRITERIA AND LOADS: 1. WIND DESIGN: WIND SPEED (MPH) V(ADJ)=127 V(ULT)=160 RISK CATEGORY II EXPOSURE CATEGORY C ENCLOSURE CLASSIFICATION PARTIALLY ENCLOSED INTERNAL PRESSURE COEFFICIENT CPI =+/- 0.55 TOPOGRAPHIC FACTOR KZT =1.0 2. DESIGN LIVE LOADS: a. ROOF LIVE LOAD 20 PSF 3. DESIGN DEAD LOADS: a. ROOF DEAD LOADS 17 PSF 4. FLOOD LOAD INFORMATION a. FLOOD ZONE PER FIRM X 5. RAIN LOAD INFORMATION: a. 100-YR, 1-HR RAINFALL 4.5 IN 6. THE CONTRACTOR HAS THE RESPONSIBILITY TO NOTIFY THE STRUCTURAL ENGINEER OF RECORD (SER) OF ANY ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING LOAD IMPOSED ONTO THE STRUCTURE THAT DIFFERS FROM, OR THAT IS NOT DOCUMENTED ON THE ORIGINAL CONTRACT DOCUMENTS (ARCHITECTURAL/ STRUCTURAL/ MECHANICAL/ ELECTRICAL OR PLUMBING DRAWINGS). PROVIDE DOCUMENTATION OF LOCATION, LOAD, SIZE AND ANCHORAGE OF ALL UNDOCUMENTED LOADS IN EXCESS OF 400 POUNDS. PROVIDE MARKED -UP STRUCTURAL PLAN INDICATING LOCATIONS OF ANY NEW EQUIPMENT OR LOADS. SUBMIT PLANS TO THE ENGINEER FOR REVIEW PRIOR TO INSTALLATION. GENERAL REQUIREMENTS 1. PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES. 2. THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE "FLORIDA BUILDING CODE (FBC)", SEVENTH EDITION, HEREAFTER REFERRED TO AS THE FBC, AS ADOPTED AND MODIFIED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 3. WHERE OTHER STANDARDS ARE NOTED IN THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD. 4. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACY OF THE WORK WITH ARCHITECT, ENGINEER(S) AND OTHER TRADES; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY; AND FOR PERFORMING WORK IN A SAFE AND SECURE MANNER. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK. 6. THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE TEMPORARY SHORING, BRACING, AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE IS COMPLETE. DO NOT LOAD STRUCTURES NEW OR EXISTING WITH WEIGHT THAT WILL ENDANGER THE STRUCTURE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. STRUCTURAL CERTIFICATION 1. I CERTIFY THAT THE PLANS AND SPECIFICATIONS COMPLY WITH THE STRUCTURAL PORTION OF THE FLORIDA BUILDING CODE SEVENTH EDITION. 2. 1 ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED IN SECTION 1609 IN THE FBC AND CHAPTER 3 IN THE FBC-RESIDENTIAL. WOOD CONSTRUCTION NOTES 1. ALL WOOD AND WOOD CONSTRUCTION SHALL COMPLY WITH THE SPECIFICATIONS AND CODES INDICATED IN THE DESIGN CRITERIA. 2. SHEATHING SHALL BE IN ACCORDANCE WITH PS 1-95 /ANSI A 199.1. ALL SHEETS BEAR APPROPRIATE GRADING STAMP OF APA AND SPAN RATING. PROVIDE 1/8" SPACE AT PANEL EDGES AND END JOINTS UNLESS OTHERWISE NOTED. 3. ALL WOOD FRAMING SHALL BE FABRICATED AND INSTALLED PER AITC AND TPI NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. 4. ALL PRESERVATIVE TREATED WOOD REQUIRED TO BE TREATED PER CODE OR DRAWINGS SHALL BE IDENTIFIED BY THE QUALITY MARK OF AN INSPECTION AGENCY THAT HAS BEEN APPROVED BY AN ACCREDITATION BODY THAT COMPLIES WITH THE REQUIREMENTS OF THE AMERICAN LUMBER STANDRAD COMMITTEE TREATED WOOD PROGRAM, OR EQUIVALENT. 5. ALL LUMBER SHALL MEET THE STANDARD OF QUALITY AS STATED IN FBC 2303. 6. LUMBER SHALL BE IDENTIFIED IN ACCORDANCE WITH NATIONAL GRADING RULES AND SHALL BEAR GRADE STAMP OF SPIB, OR OTHER ASSOCIATION RECOGNIZED BY DOC PS 20 OR EQUIVALENT. 7. ALL METAL CONNECTIONS AND FABRICATIONS SHALL COMPLY WITH AISC OR AISI SPECIFICATIONS. 8, LUMBER 2-INCH OR LESS IN NOMINAL THICKNESS AND SHEATHING SHALL NOT EXCEED 19% MOISTURE CONTENT AT TIME OF INSTALLATION. AND SHALL BE STAMPED "S-DRY", "K-D", OR "MC15". ALL LUMBER SHALL BE S4S. 9. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE TREATED, OR HAVE APPROVED SEPARATING MATERIAL. 10. ALL LUMBER SIZES NOTED AND SPECIFIED ON PLANS ARE NOMINAL SIZES UNLESS SPECIFICALLY INDICATED AS NET SIZE. 11. UNLESS NOTED OTHERWISE, THE FOLLOWING MINIMUM LUMBER GRADES SHALL BE USED: a. STRUCTURAL ROOF AND WALL FRAMING - #2 SYP. b. ROOF FRAMING MEMBERS ABOVE THE CEILING LINE - #2 SYP c. WALL SHEATHING SHALL BE 24/16 SPAN RATED STRUCTURAL SHEATHING. 12. ROOF SHEATHING SHALL BE SPAN RATED STRUCTURAL SHEATHING, ATTACHED TO ROOF FRAMING WITH GALVANIZED NAILS AS SPECIFIED IN ROOF SHEATHING AND ATTACHMENT SCHEDULE AND FOLLOWING AMERICAN PLYWOOD ASSOCIATIONS RECOMMENDATIONS. PROVIDE $" SPACING AT PANEL EDGES AND END JOINTS U.N.O. 13. ALL WALL SHEATHING FOR EXTERIOR WALLS SHALL BE SPAN RATED STRUCTURAL SHEATHING, INSTALLED WITH FACE GRAIN PARALLEL TO SUPPORTTS. CONNECT TO SUPPORTS WITH GALVANIZED NAILS PER THE DRAWINGS. PROVIDE 2X4 BLOCKING AT ALL HORIZONTAL JOINTS. PROVIDE .1" SPACE AT PANEL EDGES AND END JOINTS U.N.O. 13. FASTENERS AND CONNECTORS USED ON UN -TREATED WOOD EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. 14. FASTENERS AND CONNECTORS (INCLUDING TRUSS PLATES, NAILS, BOLTS, ANCHORS, ETC.) USED IN CONTACT WITH TREATED WOOD SHALL BE COMPATIBLE WITH THE TREATMENT METHOD AND AS FOLLOWS: a. WOOD TREATED WITH DOT SODIUM BORATE (SBX) -MINIMUM G90 ZINC COATING. b. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON -DOT) - MINIMUM G185 INC COATING. c. FOR ALL OTHER TREATMENT - COMPLY WITH THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD SUPPLIER d. STAINLESS STEEL CONNECTORS AND FASTENERS MAY BE USED FOR ALL TYPES OF TREATED WOOD 15. WOOD FASTENING SHALL BE AS SPECIFIED IN THE DRAWINGS. FASTENING NOT SPECIFICALLY IDENTIFIED ON DRAWINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. 16. CONTRACTOR SHALL PROVIDE ALL FASTENING DEVICES NECESSARY AND SUITED FOR EACH APPLICATION. FASTENINGS IN CONTACT WITH MOISTURE SHALL BE HOT -DIPPED GALVANIZED CONFORMING TO ASTM A-158-80. 17. SHEATHING NAILS OR SCREWS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IF FLUSH WITH THE SURFACE OF THE SHEATHING. 18. STUDS SHALL HAVE FULL BEARING ON A SOLE PLATE OR SILL NOT LESS THAN 2 INCHES IN THICKNESS HAVING A WIDTH NOT LESS THAN THAT OF THE WALL STUDS. 19. ALL PRESERVATIVE SOLE PLATES OR SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD AND SHALL MEET THE FOLLOWING: a. ALL ANCHOR BOLTS SHALL HAVE 2"X2"X1/8" PLATE WASHERS UNLESS NOTED OTHERWISE. b. BOLTS SHALL BE LOCATED AT CORNERS AND JAMBS AND WITHIN 4-INCHES OF EACH END OR JOINT IN PLATE. c. PLATES LESS THAN 20 INCHES IN LENGTH SHALL HAVE ONE ANCHOR INSTALLED IN THE MIDDLE THIRD OF THE PLATE LENGTH. d. SLEEVE ANCHORS ARE NOT PERMITTED UNLESS NOTED OTHERWISE. e. ANCHORS SHALL BE MINIMUM'/" DIAMETER EMBEDDED 7 INCHES INTO THE CONCRETE AND SPACED NOT MORE THAN 4 FEET UNLESS NOTED OTHERWISE. 20. WOOD FRAMING MEMBERS INCLUDING SHEATHING RESTING ON AN EXTERIOR FOUNDATION CLOSER THAN 8 INCHES FROM EXPOSED EARTH SHALL BE APPROVED NATURALLY DURABLE WOOD OR TREATED WOOD. 21. BUILT UP LUMBER (MULTIPLE MEMBERS) MUST BE FASTENED TOGETHER TO ACT AS ONE TO RESIST THE APPLIED LOAD. PROVIDE MINIMUM 2 ROWS OF 16D @ 12" O.C. 22. POSTS OR COLUMNS SUPPORTING PERMANENT STRUCTURES AND EMBEDDED IN CONCRETE THAT IS IN DIRECT CONTACT WITH THE EARTH SHALL BE OF NATURALLY DURABLE WOOD OR PRESERVATIVE -TREATED WOOD. 23. STUDS SHALL BE PLACED WITH THEIR WIDE DIMENSION PERPENDICULAR TO THE WALL. 24. NOT LESS THAN THREE STUDS SHALL BE INSTALLED AT EACH CORNER OF AN EXTERIOR WALL. 25, WOOD CONNECTORS AND HOLD-DOWNS SHALL BE AS SPECIFIED IN THE DRAWINGS AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL PRE -MANUFACTURED CONNECTORS SHALL HAVE NAILS OR SCREWS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, DRIVEN FULLY. 26. EVERY ROOF RAFTER, ROOF JOIST OR TRUSS SHALL BE ANCHORED TO THE BEAM OR WALL ON WHICH THEY BEAR. ABBREVIATIONS AB - ANCHOR BOLT HORIZ - HORIZONTAL AFF - ABOVE FINISHED FLOOR IN - INCH/INCHES ALT -ALTERNATE INT - INTERIOR APPROX - APPROXIMATELY MAS -MASONRY ARCHL - ARCHITECTURAL MAX - MAXIMUM BOTT -BOTTOM MIN - MINIMUM BRG - BEARING MISC - MISCELLANEOUS CCCL - COASTAL CONST. CONTROL LINE MPH - MILES PER HOUR CFS - COLD FORMED STEEL (N) -NEW CMU - CONCRETE MASONRY UNIT NTS - NOT TO SCALE COL -COLUMN O.C. - ON CENTER CONC - CONCRETE PSF - POUNDS PER SQUARE FOOT CONT - CONTINUOUS PT - PRESSURE TREATED D&E - DRILLED AND EPDXIED REV - REVISION/REVISED DBL - DOUBLE SPECS - SPECIFICATIONS DIA - DIAMETER SCHED -SCHEDULE DIM - DIMENSION SYP. - SOUTHERN YELLOW PINE DiN -DOWN SS - STAINLESS STEEL EA -EACH T&B - TOP & BOTTOM ELEV - ELEVATION/ELEVATOR TYP. - TYPICAL ENGR - ENGINEER UNO - UNLESS NOTED OTHERWISE EW - EACH WAY VERT - VERTICAL EXIST, (E) - EXISTING V.I.F. - VERIFY IN FIELD EXP - EXPANSION W/ - WITH EXT - EXTERIOR W/O - WITHOUT F13C - FLORIDA BUILDING CODE WRB -WEATHER RESISTANT BARRIER FI= - FINISH FLOOR #5 - STEEL REINFORCING BAR FND - FOUNDATION (REBAR) #5 (5/8") FT - FEET/FOOT FTG - FOOTING (E) HOUSE LOCATION PLAN N SCOPI OF WORK: 1. REMOVE EXISTING ALUMINUM PORCH COVERING STRUCTURE. 2. BUILD NEW PORCH PER PLANS. (N) C LUMNS, TYP. I I ® I I I I I I I I I I ® I I (E ALUMINUM FRAME & OVERING - TO BE EMOVED I I I I I I ® ® I I I I I I I PRODUCT APPROVAL AFFIDAVIT FORM CATEGORY /SUBCATEGORY APPROVAL NUMBER(S) MANUFACTURER MODEL NUMBER BUILDING DESIGN PRESSURES PRODUCT DESIGN PRESSURES (+PSF) (-PSF) (+PSF) (-PSF) A. EXTERIOR DOORS 1. SWINGING FL#16708.1 JELD-WEN SMOOTH PRO PER SCHEDULE +65 -65 B. PANEL WALL 1. SIDING FL#34867.1 PLY GEM SIDING GROUP VARIFORM CONTRACTOR'S CHOICE +42 -52 +70.8 -70.8 DOUBLE 4" VINYL SIDING C. ROOFING MATERIALS 1. METAL ROOF FL# 17796.E-R2 ATLANTIC METAL II 26 GA. 5V CRIMP ON PLYWOOD PER SCHEDULE ..156.5 OF VERO BEACH, INC. 2. UNDERLAYMENT FL# 5259-R3 POLYGLASS USA POLYS1 iCK TU-MAX N/A N/A NOTE: THE ENGINEER HAS REVIEWED THE ABOVE COMPONENTS OR CLADDING AND HAS APPROVED THEIR USE IN THIS STRUCT( 'RE. THESE PRODUCTS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. N 0 N N o') 0 0 z w w z (D z w w J H Z O _H W V9 aolr IcolLol"4-lcolc'4<,jl IIQ m N U Q 0� W O > �' O O Q N N N `- 0 W Q Lu U co W � ® O U 0 (n O n in o U w < C Q CV N Z U r) O � to _cl NN vv (n Q Q U a a I ^a c;�w I im V CD ww 0 z IV � oCL m �w w M� Lu z W >z Z w 0 Y wNO _cn cO J F Ln n ems- ''I V m ::) Q Z _ OUNN I w n � 7 Z W .: �o�_x wa U) Lu z0 Qz J Q z� 0 U Q U 0 J U) z Q Q 0 ry O J LL W C) z z O N W F N ® Q J U) C) m c Q m �.�..� N N N L.1_ _ U� I- O 0. IZ I w U w ry O LL 00o , �! STATE OF o .o�'o o F4pR FSSt6N' ��l�1LF0 VI LAMIZAR - , FL. P.E.#61000 DATE: 09-10-2021 1 SHEET N O PERMIT SET 0 co N 3 oa r ❑ N RETE CURB :TIONS 1 HDUS-SDS 2. OL OWN MINDE N PRESSURE ULE DS PER SQUARE FOOT) NEW EXTERIOR WALL CEILING MOUNTED ® 2x4 P.T. STUDS @ 16" O.C. INCANDESCENT LIGHT FIXTURE ON TOP OF 6" CONC. CURB EXISTING EXTERIOR WALL (1 WALL MOUNTED Y INCANDESCENT LIGHT FIXTURE LIGHT SWITCH FOUNDATION PLAN - WIRE INDICATION SCALE: 1/4" = 1'-0" FOUNDATION SCHEDULE MARK W x D x L REINFORCEMENT NOTES F-1 12" X 14" X CONT. (1) #5 BAR CONT. (E) THICKENED EDGE FOOTER SCALE: 1/4" = 1'-0" - __ - ZONE 2e (-) N.A. N.A. ZONE 2n (-) N.A. N.A. ZONE 2r (-) N.A. N.A. ZONE 3 (- -96.79 -58.08 ZONE 3'(-) -125.07 -75.04 ZONE 3e (-) N.A. N.A. ZONE 3r (-) N.A. N.A. OVERHANG ZONE ALL ZONES (+) 45.71 27.42 ZONE 1 (-) -130.42 -78.25 ZONE 1'(-) N.A. N.A. ZONE 2 (-) N.A. N.A. ZONE 2'(-) N.A. N.A. ZONE 2e (-) -130.42 -78.25 ZONE 2n (-) -165.88 -99.53 ZONE 2r (-) N.A. N.A. ZONE 3 (-) N.A. N.A. ZONE 3'(-) N.A. N.A. ZONE 3e (-) -175.46 -105.28 ZONE 3r (-) -190.93 -114.56 COLUMN SCHEDULE EDGE DISTANCE, a = 3 FT VALUES SHOWN FOR E.A. = 32 FT MARK TYPE REINFORCEMENT/CONNECTION NOTES C-1 4x4 P.T. SYP. #2 PER DETAIL / (E) METAL TO REVAIN N TOP OF BEAM *'ELEV: 10'-6" TOP OF E WALL *ELEV: 1 '-3" (N) 4x4 P.T. SYP. #2 POST PER PLAN (E) HOUSE ,h (E) FLOOR ELEV: 2'-3.5" Al PROVIDE FLASHING 2 (N) METAL ROOF 1 / -- 112 N TOP OF BEA 7ELEV: 8'-6" (N) BEAM PER PLAN & SCHEDULE (E) STAIRS TO REMAIN _ a 2. 6 Avg k, SCALE: 1/4" = 1'-0" (N) 4x4 P.T. SYP. #2 POST PER PLAN (N) 2x4 P.T. SYP. #2 KNEE BRACES ON REAR COLUMNS PER PLAN & DETAIL (E) HOUSE zR N TOP OF FOOTER I I F WE T ELEVATI N 11-011 SCACE (N) BEAM PER PLAN & SCHEDULE (E) STAIRS TO REMAIN (N) 44 P.T. SYP. #2 POST PER PLAN �E) METAL ROOF TO REMAIN (N) METAL ROOF I I I I I I I I I 1 1 -�4 (N) 6" CURB PER PLAN muur LVIVCJ a = 3'-0" SCALE: 1/4" = 1'-0" �1 TOP OF (E) WALL k ELEV: 10'— (N) STORAGE ROOM PER PLAN (E) FLOOR rh ELEV: 2'-3.5" (E) GRADE ELEV: U-0" cD co z Z O LLI LLI z N w LLI w Q > CD N U Q uW No > w o O Q N N N Q O z 0 3 W Y U W co y W (n o �n o U Li • ~ N 7 rn t,OD N� _Q Z U O zz* NN �, " cn V) Q Q U a I I LL U Z Q W Lj z� z NN _ L f � Wim m� J :E L.LJ Q Lil Wiz J � W >z 0 Wrnn Z� ~.W)� J W N O O O ff) v J r=�n ■ m oQNN JiQ (n I Wnr Z — z m G� uj � o n uj a (15 Z Oo Z \Q LLJ / Z J J U) LL! -J LLI Z QzIN 0 O za0 OLLry �H �O 0 O z� Z) O LL w U z z O N W F Q Q J �^ Q N VJ � W Q N U� <_ O u') L.L 0- El �� �p0 �,10E 00 yt o STATE OF LFO VI LAMIZAI !/III FL. P.E.#61000 DATE: 09-10-2021 SHEET S2 2 OF 3 21-0126 0 O LL PERMIT SET 2x MEMBERS (2) SHOWN 4" 1" MIN. ° 1/2" PLYWOOD SPACERS (1) SHOWN 2 1/4" MIN. NOTE: CONSTRUCTION ADHESIVE, APPLY IN CROSS HATCH PATTERN TO ALL MATING SURFACES. NAILS TO BE 12d 2 SCREWS TO BE #10 12" O.C. 24's 2 ROWS 2x10's 3 ROWS 2x8's 2 ROWS 2x12's 3 ROWS (NAIL ON BOTH SIDES FOR MORE THAN 2 PLIES) MULITPLE PLY BEAM DETAIL SCALE: 3/4" = 1'-0" NG MA SHEATHING PER SCHEDULE 2x6 P.T. SYP #2 RAFTERS PER PLAN 2x6 P.T. SYP #2 CONT. W/ (2) #12 @ EA. RAFTER (2) 2x8 P.T. SYP. #2 BEAM —� Z/LCE4 PER PLAN & SCHEDULES12 STRAP R SCHEDULE RAPS ER P CHEDU 4X4 P.T. SYP. #2 POST PER PLAN DETAIL A SCALE: 3/4" = 1'-0" DETAIL B SCALE: 3/4" = 1'-0" ✓2x8 P.T. SYP. #2 BEAM PER PLAN & SCHEDULE (E) WALL REMAIN 2" CLEAR, TYP. a 0 `o a L 2 0 a N m No 4x4 P.T. SYP, #2 POST PER PLAN !U44Z STRAP PER AN & SCHEDULE )CONCRETE FOOTER REMAIN PROVIDE FLASHING � ROOFING MATERIALS STRAP PER SCHEDULE 2"x4" BRACE @ EA. EXTERIOR POST 2x4 P.T. BASE PLATE W/ 2' ATR @ 24" O.C. MAX. W/ SET-3G D&E 4 MIN. INTO (E) FOOTER AS APPLICABLE BEAM PER SCHEDULE KBS1Z STRAP W/ (12) 8d x 12" NAILS KNEE BRACE DETAIL SCALE: 1/2" = 1'-0" TH SP4 STRAP W/ (6) 10d x 12" TO STUDS (N) 4"W x 6"D CONCRETE CURB W/ (1) #4 CONT. ,,\, 4" IN. m NEW WALLS @ (N) CURB TO (E) FOOTER DETAIL SCALE: 3/4" = 1'-0" #5 DOWEL BAR @ 36" O.C. EPDXIED 4" INTO EXISTING FOOT,IFI� PER PRODUCT APPROVAL 2 SHEATHING PER 712 SCHEDULE 2x6 P.T. SYP #2 _ RAFTERS PER PLAN LT512STRAP PER SCHEDULE — LUS26 STRAP PER SCHEDULE AC4/LCE4 STRAPS WHERE APPLICABLE PER SCHEDULE 4x4 P.T. SYP. #2 POST PER PLAN ABU44Z STRAP PER SCHEDULE (E) CONCRETE SLAB TO REMAIN (E) 122WV x 14"D FOOTER TO DEMAIN (N) 4"W x 6"D CONCRETE CURB W/ (1) #4 CONT. IN. 4" IN. � , a . NEW CURB TO EXISTING FOOTER/SLAB DETAIL SCALE: 3/4" = 1'-0" (2) 2x8 P.T. SYP. #2 (N) BOTTOM OF BEAM,{, BEAM PER PLAN 1, 4,. MIN. ELEV: T-10" & SCHEDULE AC4/LCE4 STRAPS SEE DETAIL A WHERE APPLICABLE PER SCHEDULE 4x4 P.T. SYP. #2 POST PER PLAN STRAPPER SEE DETAIL B SCHEDULE TOP OF FOOTER r1, xx °x ELEV: 0'-0" � o (E) W x 14"D FOOTE ZO RWAIN SECTION SCALE: 1/2" = 1'-0" S3 ROOFING MATERIALS PER PRODUCT APPROVAL 2 SHEATHING PER �12 SCHEDULE 2x6 P.T. SYP #2 RAFTERS PER PLAN 1'-4" 2x6 P.T. SYP #2 (2) 2x8 P.T. SYP. #2 RAFTERS PER PLAN BEAM PER PLAN & SCHEDULE LTS12 STRAP PER SCHEDULE 34 W/ (12) 8d x 12" NAILS @ BEAM/TOP PLATES @ 32" O.C. MAX. DBL 2x4 TOP PLATE W/ 4" LAG SCREWS @ 16" O.C. & 2" MIN. EMBEDMENT SCALE: 1/2" = 1'-0" 32" CDX SHEATHING W/10d@6"O.C. VYNIL SIDING PER DETAIL 2x4 SYP, #2 STUDS @ 16" O.C. BETWEEN COLUMNS PER PLAN 2x4 P.T. BASE PLATE ATR @ 24" O.C. D&E W/ SET-3G 4" MIN INTO (E) FOOTER 4x6 CONCRETE CURB PER PLAN (E) 12"W x 14"D FOOTER TO REMAIN S3 2x4 P.T. BASE PLATE W/ 2" ATR @ 24" O.C. MAX W/ SET-3G D&E 2" MIN. INTO (E) SLAE AS APPLICABLE (E) SLAB STRAP 10d x 12 TO STUDS 'W x 6"D CONCRETE CURB #4 CONT. NEW WALLS @ (N) CURB TO (E) SLAB DETAIL SCALE: 3/4" = 1'-0" NOTE{ SEQUEI 2x WALL FRAMING AT 16" O.C. MAX. z" CDX SHEATHING PER SECTION MOISTURE BARRIER DRAINAGE PLANE W/ 2" FIELD LAP MIN., STAPLED IN PLACE GLAVANIZED STEEL ROOFING NAILS, 12" LONG W/ "0 SHANKS & $" HEADS @ EA. STUD SPACED NOT MORE THAN 10" VINYL SIDING DRAINAGE PLANE OVERLAPS CONTROL BEAD FLASHING AND MEMBRANE STRIP OVER WOOD FRAME TO SLAB INTERSECTION 3.5" TALL WEEP SCREED "Z" FLASHING W/ DRIP EDGE MEMBRANE STRIP COVERING WOOD FRAME TO CURB INTERSECTION UNDER CONTROL BEAD, FLASHING EQUAL TO PROTECTO WRAP BT20XL 9" WIDE TO EXTEND 2" BELOW THE CMU SIDING DETAIL AT SLAB SCALE: 3/4" = 1'-0" ?o7 N 0 N � H z_ Z 0� O w w N z z w W w 99 J > Lo lq- Co N a Of cc,)of o Q N N w Q O W 0 � W Y � Z W U W co o Ln (n S w ~ Loao d Q N ^� r Z o (f) Q 0-1 •w/,� U 1 1 V J J -i-j w Z�U l Q z oa N m J w 2u- Qw LJJ Z W >z UJ 0 Z cn W�M� w U WNo 0 Z u� I o1-_�,DrZ U.J n n - ■ - � O Q N rl Q z 1 m �. uj K) o . U °way J Q w 0 J �< L.L U v! oiii'�Fp t�� O� vc E F 9- 00 STATE OF R '�cS°°°°° ° 40, 'L� A L�°FO 4.9A.- MIZARsj6 ,FL. fP.E.#61000 DATE: 09-10-2021 SHEET S3 3 OF 3 21-0126 w U w n F- w O PERMIT SET