HomeMy WebLinkAboutSCOPE OF WORK DOOR & WINDOW REPLACEMENTArchitectural Specification
General Scope of Work:
7. MATERIALS AND METHODS OF CONSTRUCTIONS SHALL CONFORt\11 TO THE REQUIREMENTS FOR SAINT LUCIE COUNTY
FLORIDA AND THE FLORIDA RESIDENTIAL BUILDING CODE, 2020 EDITION. 7th Edition
2, SCOPE OF WORK INCLUDES:
a) REMOVE CMU BLOCK WALL TO MAKE SPACE FOR 6' SLIDING GLASS
b) REMOVE EXISTING 2" X 6" X 3' ROTTED HEADER - REPLACE HEADER WITH 2" X 6" X 8' TREATED LUMBER
c) FRAME NEW OPENING WITH 2" X 6" TREATED LUMBER FOR NEW 6' SLIDING GLASS DOOR
d) REMOVE EXISTING (3) WINDOWS AND INSTALL (2) NEW WINDOWS
1, FRAMING ANCHORS: SIMPSON GALVANIZED, WIALL NAILS, SCREWS AS SCHEDULE"'
2. HEADER BEAM SOUTHERN PINE 1
PRO I)UCIT APPRO'VAL
WINE) &FEEID ]EOult or 116 asd rrjoh (T--R301.2.13)
PART
Product
Model #
Manufacturer
Description
Size, Spacing Embedment
(psi)
(Fyb)
Design
Pressur
_(P �sf
ECO WINDOW SYSTEMS
NOA# 17-0809.37
ECO WINDOW SYSTEM
WHITE IMPACT GLASS
2" for installation
Pre -drill all fastener holes with a 1/4" drill
ECO WINDOW SYSTEMS
with wood framing
bit for Woodtite and Metaltite fastners to
2
SLIDING GLASS DOOR 700
WHITE
NOA# 18-1220.09
ECO WINDOW SYSTEM
2 3/4" SILL RISER
accommodate for thermal movement of the
+70.0
+70,0/-80.0
3/16" HS +.090 PVB
Panel
+ 3/16 HS
SIMPSON STRONG -TIE CO.
MST SERIES TIE
3
MST27 STRAIGHT STRAPS
FL# 10456.20
2151 S. AIRPORT DRIVE
STRAPS 27" LONG AND
McKinney, TX 75069
2 1/16 WIDE
,so I
ieplace the Single Patio Door
and Window Replacke ROttE.1n wood Doo
Header with pressure tmld"-fted wood
0
DE51ON STATEMENT:
DE516N PARAMETER:
JURISDICTION SAINT LUCIE COUNTY
2020 FLORIDA RESIDENTIAL BUILDING CODE, Ith EDITION
BUILDING DE516N: DOOR(REAR 5LIDER) AND ALTERATION TO STRUCTURAL OPENING
nND CODE: A5CE 19-16 15EC, OU5TJ FUND SPEED: 160MPH
A5D 130 MPH
RISK CATE&ORY:
EXPOSURE
ROOF OVERHANO:
ROOF PITCH:
COVERED PATIO
CONSTRUCTION:
TYPE V
UNPROTECTED, UN5PRINKLERE-0
REMOVE ROTTED HEADER AND IM-nT ALL PATIO DOOR
2X FRAME WALL
2X FRAME WALL WITH INSULATION
2X BEARING WALL WITH STUDS AT 16"O.C.
CONCRETE BLOCK WALL
BRICK VENEER
Doi DOOR NUMBER
WINDOW NUMBER
F
-EIF,,'RO1] REMODELING NUMB
I I
DETAIL NUMBER —
SHEET NUMBER
�4 BUILIDING, SECTION TAG
DETAIL NUMBER__,
SHEET KDETAIL KEY H IKAQ�7F_) — A MC MEDICINE CABINET
ELEVATION_.,D INTERIOR ELEVATION KEY
NUMBER VIEW
ORIENTATION
H11
S I Mm"
4%� H
No. 52101
% I
?0 STATE OF
ZORID
v \�V
This item has be -,.-In
electronically s�igried and
sealed by Joe 13�,,rnmons,
on the date/tirl`)Estamp
shown using a cli(jital
sic gnature. PrintE�ld copies
ofthis document are not
considered Sign&d and
sealed and the siii n, tUrE� ig Ell
must be verified c)n any
electronic copies):.
DATE: Joseph,'�Immons RE-
Engin(Nir of Records
-% vov,
cot&v
V50cc
r�
EXISTING FLOOR PLAN
5CAL : 1/4" = P _ 011
EXISTING SCREENED
ENCLOSED PATIO
EXISTING FRAMED
HEADER
TO BE REPLACED
WALL REMOVAL AS
NEEDED FOR ro' DOOR
SECT(ON E�l ELEVATION
SCALE:
EXISTING AfiREA OF ION EXI,5TINC;s UJINDOUJ TO PE CN,4NGED
� S Iy
IMA
NEW 2 "x6 "xV TREATED LUMBER
HEADER OVER NEW 6' SLIDING
GLASS DOOR
EXISTING SCREENED
ENCLOSURE
eCALE,- 1/.4" = V —011
This item has been
electronically signed and
sealed by Joe Simmons,
on the date/time stamp
shown using a digital
signature. Printed copies
of this document are not
considered signed and
sealed and the signature
must be verified on any
electronic copies.
f �..� •� C—
o,� C�-n a SEAL
DATE:
No. 62101
�® •°• STATE OF
Joseph Simmons P.E.
Engineer of Records
9272021#
SIMPSON H-1 TOP PLATES TO EXISTING TRUSS
SIMPSON MST27 STRAPS
BOTH SIDES AND OVER TOP OF
REPLACED 2 x 6 x 8 HEADER
jf
j1�
fI
T_
L
MIN DESIGN
PRESSURE
+70.0/-80.0
,c_;CAL=E-_ 1/4 11 1 0
THREE r,
URETHAN
TYPICAL
MECHANIC
2xS PT WC
TO EXTEF
BLOCK F
INSTALL 6" WIPE
SELF -ADHERING
MEMBRANE FLASHING
OVERLAPPIW3 DOOR
114
FENE5TfRATION DEIAIL6 DOOR6
N. T,5,
INSTALL DOOR PLUMB,
LEVEL AND SQUARE M
MANUFACTURERS
WRITTEN INSTRUCTIONS
SET TWRESWO
OF SEALANT.
APPLY SEAL
CORNERS ANI
.PGE E OF T44R
INSTALL 61 ILAIDE
SW-AP44ERNG MEMB#
FLASHING OYSPLAPPIN
DOOR FRAME tv
SEE DOOR DEU
F�Nlc-
'11110 0 WzA9ME_ffffr_AU1 fie." 9'
CONCRETE 5LOCK WALL
WITH NEW &'-0 SLIDING GL:
INSTALLED
SCREEN ROOM
EX16TINrz CONCRETE
5LOC-K WALL
(2) WINDOWS NOA* 1-1-050'331
ECO WINDOW SYSTEMS
I
-zAfR EL_JHVANON ESE I N ED C FFRCIFO�5EID Wo
&CALE: 1/4 1'- O''
PREP 4 PRIME ALL
SURFACES MIN. Or rp
ON CM * AS REQUIf
WOOD (SUCKS TO RE
SELF-ADWERW-1 MEfi
FLASHING PER
MANUFACTURERS WR
SPECIFICATIONS
SELF -ADHERING
L4NE FLASHING I"
MO
NO JAMS
ROTE:
1. IT IS THE CONTACTORS FZESPONS15ILTY TO VERIFY
THE COMPATIBILITY OF ALL PRODUCTS INCLUDING
HOUSEWRAP, SEALANTS 4 FLEXIBLE FLAS44NG
MATERIALS USED DURING CONSTRUCTION
2. INSTALL ALL MATERIALS PER MANUFACTURERS
WRITTEN SPECIFICATIONS
WARNING: SEALANTS/FLASHIN038 MAY REACT
ADVERSELY IF NOT CZMPATIMLE,
.114SE2 PREP I PRIME ALL
SURFACES To RECEIVE
MEMBRANE FLASHING PER MANUF
WRITTEN SPECIFICATIONS
CONT. CAULK @ PERIMETER.
PROVIDE 1" x 4" P.T. WOOD
BUCK ATTACHED TO MASONRY W/
1/4" DIA. TAPCON SCREWS W/
1-3/4" EMBEDMENT PLACE ALL
AROUND FOR WID BUCK TO CMU
CONNECTION
4 " LAA. TAPCON SCREWS W/ 1-3/4"
EMBEDMENT, 3" FROM CORNERS & 12" O.C. -
THROUGHOUT ON ALL (4) SIDES. BACKBED
THE WOOD BUCK WITH SEALANT BEFORE
FASTENING AND SET THE FRAME IN A BED OF
SEALANT ON ALL FOUR (4) SIDES. TYP.
PROVIDE CONT. VERT. BEAD @
EDGE.
Al WINDOW JAMB I)ETAI L
NTS
---
REF ER TO EACH INDIVIDUAL WINDOW
PRODUCT APPROVAL (N.O.A.) FOR SPECIFIC
ANCHORING REQUIREMENTS.
INSTALL 611 WIPE
BACKED FLA8+4IN
OVER WINDOW NA
AT JAMBS W/ A 21
AT SILL (PROTEC
5T-20XL or EQUI'
INSTALL 6
ADHESIVE I
Fj_A_-AIWz M
OVER DRIP
NAILING FLU
0-ROTECTC
5T-20XL or
OVER 8" CMU WALL. Typ.
_8" MASONRY UNIT.
—FILLED CELL VERIFY IN FIELD
------INSULATION ON 8" CMU
REFER TO PLANS FOR
INSULATION TYPE AND R-
VALUE.
G.W.B. TAPED, SANDED
SMOOTH AND PAINTED,
NOTE: 114" DIA, TAPCON SCREWS W/ 1-3/4"
EMBEDMENT, 3" FROM CORNERS & 12" O.C.
THROUGHOUT ON ALL (4) SIDES. BACKBED
THE WOOD BUCK WITH SEALANT BEFORE
FASTENING AND SET THE FRAIVII IN A BED OF
SEALANT ON ALL FOUR (4) SIDE TYP.
INSTALL 611
ADHESIVE I
FLEXIBLE F
MATERIAL 4
CAP JOINT
(PROTECTC
5T-20)<L ov
SIMPSON M5T21 STRAFE
APPLY CONTINUOUS
BEAD Or URETHANE
SEALANT AT I,-EA0 4
JAMBS or APPLY TC
BACK OF WINDOW
NAILING FLANGE
(SEALANT MST BE
VISIBLE AROUND TR
OUTER EDGE or
WINDOW FLANGE)
INSTALL WINDOW PLI
AND SQUARE PER
MANUFACTURERS WI4.
INSTRUCTIONS
(SUBMIT SHOP ORAI
BEAM AND
ROOF
SIMPSON FLAT STRAP MST27
FRONT & BACK OF HEADERS
!!' 111111
ENCLOSED
PATIO AREA
8" CONCRETE BLOCK WALL
HE
FLASHING
LD DRIP INPOW
PLASHING
-LA.r r BE FRAM
F'146HIN� N5TALLATION PETAL5
N.T,,5.
FLAT ROOF IN THIS AREA
EXISTING CEILING
COVERING TO REMAIN
—SIMPSON STRAP
SP4 FASTENED W/
(6) 10dxlY2" NAILS
P.T. 2"x4" TOP PLATE
FASTENED WITH Y4"x3"
LONG LAG SCREWS @ 6"
FROM ALL CORNERS AND
32" O.C. AFTER THAT
Y2" DRWALL FASTENDED
TO STUDS W/ MIN 6d
DRYWALL NAILS @ 8" O.C.
NOTE: I
THE COMPATIBILITY OF ALL PRODUCTS INCLUDING
THE CONTACTORS, FSOPMSII31LTY TO VERIFY
HOJOEURAP, SEALANTS 4 FLEXIBLE FLASHING
MATERIALS USED DURING CONSTRUCTION.
2. INSTALL ALL MATERIALS MR MANIPACTURERS
WRITTEN SPECIFICATIONS
WAENIWJ% SEALANTSA-LASWINGSS MAY REACT
ADVERSELY IF NOT COMPATIBLE.
PRE 11 4 PRIME ALL
SURFACES TO RECIEVE
4, Fii�,T I AL UJALL- _='o I I L)N MEMBRANE FLASHING PER MAN.F
WRITTEN SPECIFICATIONS
APPLY
MASTIC
ADPES11
9-FERIME,
FLASHIN
wEATHE
This item has been
\0�\ z611ff 1-1 electronically signed and
_—c,
sealed by Joe Simmons,
on the date/time, starnp
shown using a di(Iital
No. 52101 %
signature. PrintElid copies
of this document are riot
44
�0STATE _ OF %. considered signEd and
*'-."40R11D sealed and the signatuirEl
, must be verified "m anY
electronic copie,,.,,
C
DATE: Jos,:--.i h SibirrIons P.E.
1?,
E!-igineEfOof I ecords