HomeMy WebLinkAboutEvaluation Reportice-E5 Evaluation Report ESR-3760 Reissued March 2020 Revised April 2020 This report is subject to renewal March 2022. wMickes.ora 1 (800) 423.6587 1 (562) 699-0543 A Subsidiary of the International Code Councils DIVISION: 08 00 00—OPENINGS applicable code and'this report. In order to comply with the Section: 08 95 43—Vents/Foundation Flood Vents engineered opening design principle noted in Section 2.6.2.2 of ASCE/SEI 24, the vents must be installed as REPORT HOLDER: follows: FLOOD SOLUTIONS, LLC EVALUATION SUBJECT: STATIC FLOOD VENTS. 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012 and 2009 Intemationa/ Building Codee ■ 2018, 2016, 2012 and 2009 International Residential Code® Property evaluated: Water flow 2.0 USES Flood Solutions' static flood vents are used to provide for the equalization of hydrostatic flood forces on exterior walls. 3.0 DESCRIPTION 3.1 General: Flood Solutions' static flood vents are engineered, permanently open flood vents with no moving parts that automatically allow flood waters to enter and exit enclosed areas. The vents are constructed of aluminum and available In four models. See Table 1 for model designations and sizes. See Figure 1 for illustrations of the flood vents. 3.2 Engineered Opening: The Flood Solutions static flood vents comply with the design principle noted in Section 2.6.2.2 of ASCE/SEI 24 for a rate of rise and fall of 5 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, the static flood vents must. be installed in accordance with Section 4.0 of this report. 3.3 Ventilation: • With a minimum of two opening on different sides of each enclosed. area. • With a minimum of one vent for the square footage of enclosed area noted in Table 1. • Below the base flood elevation. • With the bottom of the vent located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The static flood vents described in this report comply with, or are a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The static flood vents must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict,, the instructions in this report govern:. 5.2 The static flood vents must not be used In the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED 6.1 Manufacturer's descriptive literature and installation instructions. 6.2 Detail drawings. 6.3 Engineering calculations In accordance with ASCE/SEI 24. 6.4 Quality documentation in accordance with the ICC-ES Acceptance Criteria for Quality Documentation (AC10), dated June 2014. 7.0 IDENTIFICATION 7.1 Flood Solutions' static flood vents may be used to supply natural ventilation for under -floor ventilation. See Table 1 for 7.2 net free area for under -floor ventilation provided by each of Flood Solutions' static flood vents. 4.0 DESIGN AND INSTALLATION The Flood Solutions static flood vents are designed to be installed into wails or doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the The Flood Solutions static flood vents recognized in this report must be identified by a label bearing the manufacturer's name (Flood Solutions), the model number, and the evaluation report number (ESR-3760). The holder's contact information is the following:. FLOOD SOLUTIONS, LLC ONE INDUSTRIAL PARK DRIVE BUILDING 27 PELHAM, NEW HAMPSHIRE 03076 �® www.floodsolutions.com infoM— oodsolutions.com 1CGES Evaluation Reports are not to be construed as representing aesthetics or onv other attributes nor specifically addressed, nor are they lobe construed as an endorsement of the subject gjthe repot or a recomtnendatlon for its use. There is no warranty kv lCC Evahtatlon Service. LLC, express or implied, as ' to anyjlnding or other natter in this report, or = to anyprod,,ct covered by the report. •Y Copyright 0 2020 ICC Evaluation Service, LLC. Al rights reserved. Page 1 of 3 'r ESR-3760 Most Wdely Accepted and Trusted Page 2 of 3 TABLE 1-FLOOD SOLUTIONS STATIC FLOOD VENTS VENT SIZE ROUGH OPENING ENCLOSED MODEL (Width x Height) SIZE (Width x Height) AREA COVERAGE NET FREE AREA' (in) (In)i (ft2) (In2) FS-1608 18'/2_X 10'/2 _ 16 x 8 07 80.7 -1 16 x 1:6. " 4° �?, 191 2 Y• tgt SWt`- 412 17 x 141/2. 14 /-�2 is i�Z� 129 . _�158 108.7 FS-1608-Hex 181/2 X 101/2 16 x 8 110 91 4 For SI. 1 inch = 25.4 mm, 1 ft = 304,8 mm 'Available for use as under -boor ventilation. FS-1412 FS-1608 FS-1616 FS-1608-HEX FIGURE 1--FLOOD SOLUTIONS STATIC FLOOD VENTS