Loading...
HomeMy WebLinkAboutSuperior Sheds Plans" 2"x2" GALVANIZED WASHER WITH Y" NUT EYES BOLTED TOGETHER WITH Y"x2" BOLT & NUT WITH (2) 2"x2" GALVANIZED WASHERS (2,000LB SHEAR CAPACITY) Y"x 3" (400 LB) CONCRETE WEDGE ANCHOR (SEE TABLE 1 FOR SPACING) Y" THREADED ROD OPTIONAL FOR "HIGH SET' 1/2"x5" (400 LB) CONCRETE WEDGE ANCHOR INTO SLAB -Y" COUPLER THRU 2"x4" P.T. BOTTOM PLATE (SEE TABLE 1 FOR SPACING) v 4"MIN. C NCRETE SLAB BY OTHERS ie- SIMPSON A-24 THROUGH LOCAL CODES CONCRETE SLAB BY OTHERS CLIP OR EQUAL AND JURISDICTION THROUGH LOCAL CODES AND JURISDICTION SHED WITH SKID ANCHORED TO CONCRETE SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT OF THE GROUND AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING, HOLES ARE DRILLED THRU THE 2"X4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE)_ HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF THE RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT A'NO FLOOR' OPTION, ANCHOR WITH 1/2"X5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPAC'G 20'-0" 400 T-6" 13'•8" 280 31-6. 11'-8" 240 3'-6" 10'-0" 200 T-6" 8'-0" 160 T-6" 6'-0" 120 31-6" SUP[ SHED DESCI SHED WIDTH TYPE 13'-8" SW/DV 111•8" SW/DV 10'-0" SW/DV 8'-0" SW 6'-0" SW ­1 OR COUNTERSINK BOLT 2"x4" BOTTOM PLATE V BOTTOM PLATE NAILED 2"x6" P.T. BASE SHED WITH 'NO FLOOR' OPTION' ANCHORED TO CONCRETE 1/2" THREADED ROD OPTIONAL FOR "HIGH SET" 1/2" COUPLER 1/2"x12" FORGED EYEBOLT 4"MIN. EYES BOLTED TOGETHER BOLT & NUT WITH (2)2"x2" GA WASHERS (2,000LB SHEAR C 30" EARTH AUGEF (SEE TABLE 4 FOR SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1) }"x4}" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 2 SKID RUNNER SPACING' SHED WIDTH X1 X2 X3 13'•8" 1'-162" 1'-104" 1'-1 q, 111-8" 2'-8" 6'-4" - 10'-0" V-7" 6'-10" - 8'-0' 9" 6'-6" 6'-0" 10" 51" - " VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 1 V-8" AND 13'-B" WIDE SHEDS ONLY. LOAD WIDTH OF UPLIFT ON RUNNER NOTES: 1. PAD SPACING IS END TO CENTER OF PAD 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING 1 TABLE 3A PAD TYPES TYPE PAD DIMS MAX LOAD' MATERIAL I 2"x8"X16" 1778 LBS CONC. BLOCK 0TWTn7_ CEMENT AND SAND MIX II 4"x8"X16" 3500 LBS CONC. BLOCK QUALITY CEMENT AND SAND MIX III 16"X16" 3950 LBS ABS PLASTIC PADS IV 8"X8"X16" 1900 LBS CONC. 13LOCK QUAL TTT- CEMENT AND SAND MIX ' BASED ON 2000 PSF SOIL BEARING CAPACITY (2000 PSF IS TYPICAL) NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON I V-8" AND 13'-8" WIDE SHEDS ONLY. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS WASHER 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHORS BY HOME PRIDE OF BRISTOL, VA. OR EQUIVALENT. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,725 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR +.,.GRADE ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. WITH CODE INFORMATION _ CODE VERSION F,BCH EDITION _(2O;i ASCE =16 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE MANUF. SHED CONSTRUCTION V-B CODE VERSION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NO. OF STORIES 1 BASIC WIND SPEED 180 MPH (VULT) EXPOSURE C ENCLOSURE ENCLOSED INTERNAL PRESSURE COEF. +/- 0.18 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10 PSF ROOF LIVE LOAD 20 PSF OR 300LBS FLOOR DEAD LOAD 8 PSF FLOOR LIVE LOAD 75 PSF / 125 PSF "R" RATING (WALL, FLOOR, ROOF) N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 720 S.F. .:...: Z,.. 1.................... .......... i MODULAR PLANS ,DESIGN, CO. TABLE 30" AUGER ANCHOR SPACI SHED WIDTH LW* UPLIFT (PLF) ENI 13' 8 i 7.OG 243 U 11'-8" 6.00 f 208 0' 10'-0" 5.00 174 0' 8'-0" 4.00 138 0' 6-0" 3.00 104 1 0' TABLE 30" AUGER ANCHOR SPACI SHED WIDTH LW" UPLIFT (PLF) ENI 20'-0" 10.00 400 0' ' LOAD WIDTH UPLIFT ON RUNNER LOCATION FROM END WALL OF AUGER ANCHOR MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER 3. THE MINIMUM NUMBER F ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. GENERAL NOTES: 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL ,�,�, ; JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION ',�ss�oninE��Pc 1015.22 3. REFER TO TIE -DOWN DETAILS FOR PROPER Digitally signed b INSTALLATION REQMy�MENTS TO MEET CODE. g Y -U VJ�®v Julio Orbegoso Nc Date: 2021.02.01 O 16:42_51-05'00' ®®� �F. GO CCON=S,WLmT111N�G EN.G EEEF �w �OCa'G JULIQ'QRB=,G, MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE., SURE 105 OFFICE 863.688.1054 LAKEUWD• FLORIDA FAX: B63.69BJ11B 33813 COLEQMODULARPLANSCO.COM - ® Aft f'1®NI GENERAL NOTES 1. Foundation plans are not part of this plan set and are governed by local jurisdiction. 2. Buildings are approved for residential lawn storage only 3. This building is exempt from the FECC per sections R101.4.2.4, R402.1. 4. Refer to tie down details for proper installation requirements to meet code. 5. All lumber for construction will be #2 SYP except as noted. 6. Gutters shall be site installed per the local authority having Jurisdiction and permitting requirements. 7. All windows and doors to meet the minimum specifications per the approved plans and the Florida Building Code. 8. In accordance with FBC 1609.1.2, "Storage sheds that are not designed for human habitation and that have a floor area of 720 square feet or less are not required to comply with the mandatory windborne debris impact standards of this code". 9.. In accordance with FBC 1010.1.1, exception (10.) Buildings that are 400 sq-ft or less and that are intended for use in conjunction with one- and two-family residences are not subject to the door height and width requirements of this code. Structures 400 sq-ft or more shall have an 80" minimum door. 10. In accordance with Florida Statute 553.80 (1)d, lawn storage buildings and storage sheds bearing the insignia of approval of the department are not subject to 553.842 (Florida product approvals) but shall meet the design wind load requirements of the 2020 FBC 7th edition. 11. Flat metal straps can be bent around structural members of wall studs, trusses, chords, etc. To help secure these members, provided that the added bend does not interfere with any of the existing breaks/bends in the strap. 12. As per FBC section 1626.1 exception (f): storage sheds that are not designed for human habitation and that have a floor area of less than 720 square feet or less are not required to comply with the mandatory windborne debris impact standards of this code. 13. Components/Cladding are in compliance with the 2020 FBC 7th Edition. 14. Sheds located in flood hazard areas must comply with the local flood zone regulations. 15. If a wall is framed for future HVAC units that shall be approved by the AHJ and shall comply with local requirements for permitting. 16. Windows and doors installed by the customer that shall be approved by the AHJ and shall comply with local requirements for permitting. 17. HVHZ components for sheds require that installation per manufacturer's instructions. } Z a 0 0 U z U) W 0 w z g o. g 0 O 0 0 0 } a O U 'O u --TtoE-TOP LINE ENGINEERING, LLC ST _UCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 2323 S. VOLUSIA AVENUE ORANGE CITY, FLORIDA 32763 (877) 439-7433 LISTING AGENCY APPROVAL: TOP LINE ENGINEERING, LLC. BUILDING CODE RESIDENTIAL CODE ELECTRICAL CODE BUILDING TYPE MANUFACTURER AGENCY AGENCY PLAN NUMBER CONSTRUCTION TYPE FIRE PROTECTION FIRE SUPPRESSION SYSTEM OCCUPANCY ALLOWABLE # OF STORIES WIND VELOCITY FIRE RATING OF EXTERIOR WALLS FLOOR LIVE LOAD - STANDARD FLOOR LIVE LOAD - OPTIONAL FLOOR DEAD LOAD ROOF LIVE LOAD ROOF DEAD LOAD "R" RATING OF FLOOR, WALL,&ROOF MODULES PER BUILDING SQUARE FOOTAGE HURRICANE PROTECTION USAGE HURRICANE SHELTER USAGE HVHZ APPROVED FBC, 7TH EDITION (2020) FRBC, 7TH EDITION (2020) 2017 NATIONAL ELECTRICAL CODE RESIDENTIAL LAWN STORAGE SHED SUPERIOR SHEDS, LLC TOP LINE ENGINEERING, LLC BUNG-20-HVHZ V-B NO NO UTILITY 1 170 MPH, EXPOSURE C 0 75 PSF 125 PSF 10 PSF 30 PSF 10 PSF N/A 1 719 SQ/FT. MAX. NO NO YES TOP LINE ENGINEERING, LLC DESIGN PRESSURES DOORS (by EAGAN) +/-20 PSF WINDOWS (by CROFT) +/-40.10 PSF D/P INFO PROVIDED BY MANUFACTURER Please'note- .Any questions. regarding foca►,perrnit#ing should be directed to the Manufacturer, The Manufacturet's contact information can be found in fhe fifle block of the plans. APPROVED FOR HVHZ Digitally \o ogsF�o,, signed by Julio °y Orbegoso N.. 38769 _* * '*-Date: 2021.02.09 °�SS�ONALE? ' 15:09:36 -05'00' STRUCTURAL LOAD LIMITATIONS WIND LOAD CRITERIA 1. 132 Vasd/170 Vult WIND SPEED (MPH) 2. 1 RISK CATEGORY 3. II BUILDING CATEGORY 4. ENCLOSED ENCLOSURE CLASSIFICATION 5. GCpI = 0.18 INTERNAL PRESSURE COEFFICIENT 5. C EXPOSURE FACTOR 6. 0.85. _ WIND DIRECTIONALITY FACTOR (Kd) 7. 0.85 " GUST RESPONSE FACTOR (Gh) 8. Pr = -93.0 PSF MAIN FRAME STRUCTURE OVERTURNING LOAD 9. COMPONENT & CLADDING LOAD (ROOF) Pr = ZONE 1: -35.63 PSF, ZONE 2: -35.63 PSF, ZONE 3: -65.26 PSF (WALL) PW = ZONE 4: -39.14 PSF, ZONE 5: -46.89 PSF 10. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT ON THE UPPER HALF OF A HILL OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT. SEISMIC LOAD: N/A FLOOD LOAD: THIS BUILDING IS NOT DESIGNED TO BE SUBMERGED OR SUBJECTED TO WAVE ACTION WHEN LOCATED IN A FLOOD PRONE OR ZONE AREA. FINISH FLOOR ELEVATION MUST BE LOCATED ABOVE THE BUILDING SITE FLOOD PLANE LEVEL. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE REGULATIONS. DRAWING INDEX C1 COVER SHEET Al FLOOR PLAN A2 SIDEWALL FRAMING A3 FLOOR FRAMING A4 ROOF FRAMING A5 CROSS SECTIONS A6 ENDWALL FRAMING A7 SCHEDULES BUNGALOW SHED - HVHZ x:.:..._. .. `r MODULAR PLANS DESIGN, CO. MODULARZO? DORIS DRNE., SU TE 705 OFFICE: 863.668.1054 PLANS DESIGN, CO. LAKEU ND, FLOR DA FA1L'8 33873 COLS@MODULARPLANSCO,,COMNSCO.COM CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 LULI -UZ-Ub IUF LINt LNQ.ANttKINQ7 AffKUVAL t'LAN fF t5UNQ7-HVHL-ZU` HVHL AFTH0VED IrIV{OM %W'"' CEILING J-BOX I I I LINE SINGLE POLE NEUTRAL 15 AMP G.F.I. SWITCH OUTLET ELECTRICAL NOTES & OPTIONS: - AS PER NEX ARTICLE 330.30(B) SECURING OF MC TYPE CABLE. UNLESS OTHERWISE PROVIDED, CABLES SHALL BE SECURED AT INTERVALS NOT EXCEEDING 6FT. CABLES CONTAINING FOUR OR FEWER CONDUCTORS SIZED NO LARGER THAN 10 AWG SHALL BE SECURED WITHIN 12 IN. OF EVERY BOX, CABINET, FITTING, OR OTHER CABLE TERMINATION. -ALL WIRING SHALL BE 14 GAUGE 3-WIRE MC CABLE. - ENCASE IN ALL METAL BOXES. MAXIMUM NO. OF OUTLETS: 7 MAXIMUM NO. OF LIGHTS: 8 ELECTRICAL WIRING DIAGRAM SCALE: NOT TO SCALE NOTE: 1. MIN. GRADE STUDS: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER 2. MIN. ROOF SHEATHING: 29GA CORRUGATED METAL 3. MIN. FLOOR SHEATHING: %" PLYWOOD 4. MIN. WALL SHEATHING: D4 ALUMINUM SIDING NOTE: 23" SECTIONS OF 29GA CORRUGATED METAL SIDING FASTENED W/ %4" #8 HEX HEAD w/ WASHER SELF TAPPING SCREWS @ 6" ON EDGE & 12" IN FIELD. NLJ F NOTE: SHOWN IS THE 10'-0" x 20'-0" TOP LINE Et�TGIIVEERM L_ LC L STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 Jam. V\CEN&, ' . O' No.38769 ` , 0 . STATE OF '// NALI\'�� Digitally signed by Julio Orbegoso Date: 2021.02.09 15:10:26-05'00' SHED OVERALL LENGTH (MAX. 40'-0") FLOOR PLAN SCALE: 3/8" = V-0" NOTE: SHEDS TO HAVE A MAXIMUM OF 5 DOORS AND 10 WINDOWS CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZ PE LICENSE #38769 MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR PLANS DESIGN, CO. 2D2 DORIS DRIVE, SURE 105 OFFICE: 863.688.1054 IAKELAND, FLORIDA FA1<863.688.7118 33813 COLE@MODULARPLANSCO.COM DATE: 02-05-2021 DRAWN: R.L.G. JOB: SS20-BU-HVHZ SHEET NO. Al 2021-02-08 TOP LINE ENGINEERING APPROVAL PLAN # BUNG-HVHZ- HVHZ APPROVED ENDWALL DOOR & WINDOW 6'-0" WIDE OR LESS SCALE: NTS 2"X4" SYP#2 STUDS @ 24" O.C. 2"X4"X60" SYP#2 SISTER STL ATTACHED W/ 10d COMMON NAILS @ 4" O.C. Digitally signed . O ORBFG 'J��:VDENS`F•:Oso by Julio N°. 38768 = Orbe oso Date: 'p0 •'•. STATE OF :' tv�� �Fs-.ORIDP•:'G\�, 2021.02.09 15:10:50-05'00' z 0 U z 0 w 0 co z g a g 0 0 04 N IL } 0 0 U rO J OPTIONAL HYDROVENT DETAIL SCALE: NTS 3"X6" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 BOTTOM 4"X4" SYP #2 HEADER 2"X4" SYP #2 JACK STUD 2"X4"SYP #2 KING STUD 4"X4" HEADER DETAIL SCALE: NTS JD DETAIL ,6" MITEK MT20 IR EQUIVALENT "BETWEEN NT IS SECURED ,S PER INSTRUCTIONS Now ROOF TRUSSES lee., o Rio 1Oi. IJIJ�i t FLOOR DECKING "X4" SYP #2 @ • STUDS ' • ol /41HED LENGTH (MAX. '11 ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING W/ SIMPSON LTS16 STRAP w/ 5 -10d NAILS ON TOP INTO STUD, SECURING INTO RIM JOIST ON BOTTOM W/ 5-10d NAILS (TYPICAL) A SIDEWALL FRAMING SCALE: 3/8" =1'-0" NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. )4FILLER OR (1 WOOD ORO B) 4"x4" SUP[ 2323 S. VOLUSIP 2"X4" SYP#2, KING STUD SIDEWALL DOOR & WINDOW (TYP) -` SCALE: NTS MODULAR PLANS DESIGN, CO. L BUNGALOW SHED - HVHZ MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE.. SUITE 105 OFFICE: 863.668.1054 W(ELAND. FLORIDA FA%; 863.688.7118 33813 COLEOMODULARPLANSCO.COM ENDWALL SIMPSON LTS12 @ ALL TRUSS .TO HEADER CONNECTIONS. USE MIN (5) 10d NAIL INTO TRUSS & (5) 10d NAILS INTO HEADER. I TOP LINF PNGTNECFING E�LC ��,., SiRI:CfUf:AL F.NOINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace i Gotha, Florida 34734 2"X4" SYP#2 SOLE PLATE /- 2"X6" SYP#2 PERIMETER WALL SHEATHING OPTIONS: - %s' OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM - D4 ALUMINUM SIDING -Y2" OR 8" T1-11 SIDING - JAMES HARDIE PANEL OR EQUIV. - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING FPECONSULTING ENGINEER LIO ORBEGOSO FLORIDA LICENSE #38769 !1!1!1 t l'1l1 l'\!l r 1111\ a II LUG I-UL-UU IIJr L11NL L 1 N VII VL L ICI 1V V /ArrRk-ol L FLP1IV 17t DUlVv-F1VrnL-LU r1Vr1L HrrKVVtU .4 z Z a 0 0 U z 0 Co w 0 z a g 0 O 0 N } 0 U r LOJ SKID RUNNER SPACING* WIDTHS 6'-0" 8'-01, 10'-0" 1 V-8" 13'-8" A 0'-101, 0'-91, V-7" Z-8" V-10.5" B 51" 6'-6" 6-10" 6'-4" V-10.5" C - - - - V-10.5" *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SKIDS. TOP LLNE ENGINEERING, LLC STRUCTURALENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 Q m U SHED OVERALL LENGTH (MAX. 40'-0") FLOOR SHEATHING 2-1/2 X1/2° Digitally signed THRU-BOLT ��"� ORBFG \0 o.,�� 'L\CENSF'.(S % by Julio SIMPSON HL33 = No.38769 Orbegoso HEAVY ANGLE 2"x6" CONTINUOUS _ P.T. FLOOR JOIST - - O 4/ Date-0 STATE OF ��� 2021.02.09 I I I I 1 1 /2" NOTCH 15:11:10-05'00' BUNGALOW SHED - HVHZ ! ! 4"X4" P.T. SKID v! 4-1/2" X 1/2" THRU-BOLT MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 FLOOR JOIST TO SKID CONNECTION SCALE: NTS ` j\ MODULAR PLANS DESIGN, CO. MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE., SUITE 105 OFFICE: 853.GBILIOS4 LAKEIAND, FLORIDA FA%: 863.688.7118 33813 COLEOMODULARPLANSCO.COM 0 m )OR SHEATHING: PLYWOOD P.T. PLYWOOD - %4' T&G - %" P.T. T&G CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 DATE: 02-05-2021 DRAWN: R.L.G. JOB: SS20-BU-HVHZ SHEET NO. A3 2021-02-08 TOP LINE ENGINEERING APPROVAL PLAN # 13UNG-HVHZ-20 *** HVHZ APPROVED _ z a 0 0 U z 0 w 0 g o_ 5 0 0 N N EL 0 0 U N � u NOTE: INSTALLATION FOR ALL ROOF SHEATHING OPTIONS AS PER MANUFACTURER INSTRUCTIONS _ ', TOP LINE ENGINEERING. LLC `"'LL STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 471IMMAIA1 1 mCI /1LL/ nA AI 11R Alwll 1RA Mr%l rIK 1^ SHED LENGTH (MAX. 40'-0R) ROOF FRAMING PLAN SCALE: 318" = 1'-0" \�lllllllll/,�� ,•��'�o.°ReFco'% Digitally signed \-10EN&, ' �0�� by Julio No. 38769 * * - Orbegoso -Q ' STATE OF �L(,� Date: 2021.02.09 ss; ORIV••...•• 15:11:26 -05 00 , ONAI- 1`\�� U) Z) f'- J J ❑ z w N FPECONSULTING ENGINEER LIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZLICENSE #38769 MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR =moo o� �'� O18 �MM:W.;; PLANS DESIGN, CO. " COLS@MODULARPUWSCO.COM DATE: 02-05-2021 DRAWN: R.L.G. JOB: SS20-BU-HVHZ SHEET NO. rO LI MIN. 3:12 MAX. 8:12 2"X4" SYP#2 COLLAR TIE 2"X5" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 STUDS @ 24" O.C. 2"X4" SYP#2 BLOCKING 4"X4" P.T. SKID (CONT.) FLOOR DECKING (CONT.) FLOOR JOISTS @ 16" O.C. SHED WIDTH (6'-0", 8'-0", 10'-0", 1 V-8", 13'-8") A CROSS SECTION 'A' A5 SCALE: 3/8" = V-0" NOTE: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. 2"X4" ROOF TRUSSES @ 24" O.C. 2"X4" SOLE PLATE 2"X6" PERIMETER SISTER STUDS FOR 4'-0" I,FROM ENDWALL (TYP), SISTER STUDS FOR 4'-0" TYPICAL STUD SPACING 24" O.C. MAX -FROM ENDWALL (TYP), FLOO TRUSSES @ 24" 0.I I _�_ I IJJ o�JiJ� lull.��I. SEE HEADA DETAIL 1 �JiJ�JJi� � !:1Oio J� DECKING • SHED LENGTH (MAX. 40 ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING W/ SIMPSON LSTA12 STRAP w/ 5 -10d NAILS ON TOP INTO STUD, SECURING B INTO RIM JOIST ON BOTTOM A5 W/ 5-10d NAILS (TYPICAL) ' O TO_P LINE ENGINEERIi\Iq._LLC STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 WALL SHEATHING OPTIONS: -7/6" OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM CROSS SECTION 'B' - D4 ALUMINUM SIDING SCALE: 3/8" = V-0" -%2'OR%"T1-11 SIDING - JAMES HARDIE PANEL OR EQUIV. - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING BUNGALOW SHED - HVHZ MODULAR STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 MODULAR PLANS DESIGN, CO. MODULAR PLANS DESIGN, CO. 2D2 DORIS DRIVE., SUITE 1D5 OFFICE 063.08.1054 LWELAND, FLORIDA FAk 863.688.711E 33813 COLE@MODULARPUWSCO.COM — ENDWALL SIMPSON LTS12 @ ALL TRUSS —TO HEADER CONNECTIONS. USE MIN (5) 10d NAIL INTO TRUSS & (5) 10d NAILS INTO HEADER. 2"X4" SOLE PLATE 2"X6" PERIMETER ND.38768 :�Q�.• STATEOF Digitally signed by Julio Orbegoso Date: 2021.02.09 15:11:50-05'00' CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 DATE: 02-05-2021 I DRAWN: R.L.G. JOB: SS20-BU-HVHZ SHEET NO. A5 2021-02-08 TC)P I INF FNC'INFFRIN(-, APPRC)VAI PI AN 4 RIINC?-HVH7-?n *** HVH7 APPRCIVFfI A MIN. 3:12 MAX. 8:12 �/ #2 SjpDS @ 24'1 P.C. BLOCKING TE SHED WIDTH (6'-0", 8'-0", 10'-0", 11'-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. 2"X5" MITEK MT20 OR EQUIVALENT A ENDWALL FRAMING A6 SCALE: 3/8" = T-0" SHED WIDTH (6-0", 8'-0", 10'-0", 1 V-8", 13'-8") B ENDWALL FRAMING A6 SCALE: 3/8" = V-0" " ROOF TRUSSES @ 24" O.C. (4" SYP #2 STUDS @ 24" O.C. ' SYP#2 BLOCKING 2"X4" SYP#2 SOLE PLATE (6" PERIMETER MIN. 3:12 MAX. 8:12 F�:7'11 2"X5" MITEK MT20 OR EQUIVALENT (2) 2"X4" HEADER MAX 36" SHED WIDTH (6'-0", 8'-0", 10'-0", 1 V-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. B ENDWALL FRAMING A6 SCALE: 3/8" = V-0" CONSULTING ENGINEER z��TOP LINE ENGINEERING, LLC JULIO ORBEGOSO ¢ STRUCTURACENGfNEERS Digitally FLORIDA William E. Neary, I11 BUNGALOW SHED -HVHZ PE LICENSE #38769 SMP-51,SM1-79,ICC5185040 signed by Julio 10649 Oakview Pointe Terrace ��� ���' cENg.'G �' g MODULAR STRUCTURE FOR: c' J • �� F ' DATE: 02-05-2021 Gotha, Florida 34734 o ; Orbegoso SUPERIOR SHEDS EL No. 38769 _ (877) 439-7433 DRAWN: R.L.G. 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 - Date: -10 o ��Q. • •.��� '� „��� JOB: SS20-BU-HVHZ 2021.02.09 MODULAR PLANS DESIGN, CO. STATE OF 'ice '•.'�CORIDP.•••G\=� l �' SHEET NO. S'ONAV- E,,`�' 15:12:06 I -0 5 ' 0 0 ' MODULAR 202 DORIS DRNE. SU TE 105 OFFICE 863.W8.1050 OLAICEIHND, FLoww FA%.863.888.7118 PLANS DESIGN, CO. 33813 COLEQa MODULARPIANSCO.COM A6 so 1 2011-02-08 TOP LINE ENGNLEKIN(3 AFFKUVAL FLAN 4 bUNC3-HVHZ-2U *** HVHZ APPROVED H z z a. 0 0 U z 0 V) 0 Cl) z 5 a Of 0 0 F- F- (7 K EL } 0 O U SIMPSON STRONG DRIVE & STRAP - SD SCREW SCHDEULE PART#1DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER H1 435 6-SD9x1.5' 4-SD9xl.S" H11Z 750 6-SD10x25' 6-SD10x2.5" H2A 495 5-SD9z1.5° 5-SD9x7.5' 2-SD9xl.5" H2.5A 540 5-SD9x1.5" 5-SD9xl.5' H2.5 410 5-SD9z1.5° 5-SD9xl.5" H2.5T 545 5-SD9z1.5° 5-SD9x1.5" H2A 495 7-SD9xl.5° 5-SD9x1.5" H3 320 4-SD9xl.5° 4-SD9xl.5" - RAFTER H4 280 4-SD9x1.5" 4-SD9xl.5" H5 415 4-SD9xl.5° 4-SD9x1.5' LTS-12 895 6-SD9xl.5° 6-SD9x1.5" LTS-16 1075 6-SD9xl.5' 6-SD9xl.5" LTS-18 1235 6-SD9xl.5° 6-SD9xl.5" LTS-20 1215 6-SD9xl.5° 6-SD9x1.5° MTS-12 895 7-SD9xl.5' 7-SD9x1.5" MTS-16 1075 7-SD9x1.5° 7-SD9x1S" MTS-18 1255 7-SD9z1.5' 7-SD9x1.5" MTS-20 1255 7-SD9xl.S 7-SD9x1.5" PORCH PARTWDESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 2-SD9xl.5" 2-SD9xl.5' A23 4-SD9z7.5' 4-SD9xl.5' A33 4-SD9x1.5' 4-SD9xl.5' BTM PLATE PARTWDESC. UPLIFT WALL FASTENER FLOOR FASTENER LSTA-18 1235 7-SD9x1.5° 7-SD9x1.S' TIE -DOWNS PART#/DESC. UPLIFT WALL FASTENER FLOOR FASTENER 20GA. 1-114"WIDE 4725 7-SD9x1.5° 518'x30"ANCHOR 4300 r..- ONLY EEDED ON ALUMINUM SHEATHING WALLS. EAD HERS OVER V SPAN. STRAP & FASTENER SCHEDULE' PARTt#DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER HI 400 6-8dx1/S" 43d H11Z 750 6.16dx2.5' 6-16dx2.5' H2A 495 53dx1.5- 53dx1.5" 2-Sdx1.5' H2.5A 535 - 53d 5-8d H2.5 410 53d 53d H2ST 545 53d 5-Sd HZA 495 7-Bdz1.S 5-8dxl.5" H3 320 43d 43d - RAFTER (B) H4 235 43d 4.8d HS 265 43d 4-8d LTS-12 620 6-10dxl.5° 6-10dxl.5° LTS-16 620 6-1 Ddx1S' 6-10dx1.5' LTS-18 620 6-1 Odx1S° 6-10dx1S" LTS-20 620 6-1 Odx1S" 6-10dx1S' MTS-12 860 7-1 Odxl.5° 7-10dx7.5' MTS-16 860 7-1 Ddxl.S' 7A0dx1.5° MTS-18 860 7-1 Odxl.5' 7-10dxl.5' MTS-20 860 7-10dx1S° 7-10dx1.5" PORCH PART#/DESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 245 2-10dxl.5' 2-1Ddx1.5' A23 585 4-10dx1.5" 4 -1 Ddxl.5' A33 750 4 -10d 4 -10d BTM PLATE PART#1DESC. UPLIFT WALL FASTENER FLOOR FASTENER LSTA-18 1110 7-10d 7-10d HEADER (D) PART#1DESC. UPLIFT STUD FASTENER HEADER FASTENER TP35 N/R 5'3"x0.131" 5-3'x0.131' HP40,41,80,81 4725 53-x0.131' 53"x0.131" TIE -DOWNS PART#1DESC, UPLIFT WALL FASTENER FLOOR FASTENER 20GA. 1-1/4" WIDE 4725 7-10dxl.5' 518-x30-ANCHOR 4300 ' ALL STRAPS CAN BE SUBSTITUTED WITH AN EQUNALENT BRAND MEETING SAME STRENGTHS. B. RAFTER TIES TO STUD WALL TO BE AT EVERY CONNECTION FOR 24° O.C. & CAN EVERY OTHER FOR 16' O.C. BUT IS REQUIRED ON CORNERS AND STUDS ADJACENTTO CORNERS. C. ONLY NEEDED ON ALUMINUM & VINYL SHEATHING WALLS. D. HEADERS OVER 6'-0' SPAN. PRODUCT OPTIONS PRODUCT CAT. SUB. CATEGORY MANUFACTURER MODELIDESC. STATE OF FL APPROVAL#. PANEL WALLS SIDING JAMES HARDIE 5/16' CEDAR FL#. 13223.1 PANEL WALLS SIDING JAMES HARDIE 5116" STUCCO FL#. 132232 PANEL WALLS SIDING ADVANCED ALUM. D.19 GA FL#; 23138.1 PANEL WALLS SIDING PLY GEM X FL#. - PANEL WALLS SIDING ADVANCED ALUM. X 1..311.1 PANEL WALLS SIDING SIMPSON LUMBER X FL#. - EXTERIOR DOORS SWINGING EXT EAGAN E1HDL FLSk. 12820-R3 EXTERIOR DOORS SWINGING EXT CROFT 2009-CITE FL#'. - WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#. 10853A5 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#. 15527-R5 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#; 16082-R3 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#. 16153-R7 WINDOWS HORIZ SLIDER CROFT HORIZ. SLIDER FL#; 27202 WINDOWS HORV_ SLIDER CROFT HORIZ. SLIDER FL#'.28822 WINDOWS HORIL SLIDER CROFT HORIZ. SLIDER FL#. 30848 Digitally signed by Julio Orbegoso Date: 2021.02.09 15:13:28-05'00' FASTENING SCHEDULE (FBC TABLE 23D4.10.1) CONNECTION FASTENING CONNECTION 24. BUILT-UP GIRDER AND BEAMS 20d COMMON (4-X 0.192-)AT 32" O.C. 3" X 0.131 NAILS AT 24"O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE 1. JOIST TO SILL OR GIRDER 3-Sd COMMON (2112"X 0.131') TOENAIL 3 - 3' 14 GAUGE STAPLES 3' 14 GAUGE STAPLES AT 24" O.C. 2 - 20d COMMON (4" X 0.192') SIDES 2. BRINGING TO JOIST 2- 8d COMMON (2 112' X 0.131") TOENAIL EACH END 2 - 8d COMMON (2 10 X 0.1317 2 - 3" 14 GAUGE STAPLES 3 - 3" X NAILS FACE NAIL AT ENDS AND AT 3 - 3" 14 GAUGE STAPLES GAUGE EACH SPLICE 3. 1-x6- SUBFLOOR OR LESS TO EACH JOIST 2 -8d COMMON (21/2" X 0.131-) FACE NAIL 25.2' PLANKS 16d COMMON (3112' X 0.162) AT EACH BEARING 4. WIDER THAN 1"x6' SUBFLOOR TO EACH JOIST 3-8d COMMON (2112" X 0.131-) FACE NAIL 26. COLLAR TIE TO RAFTER 3 -10d COMMON (3" X 0.1481 MIN. 4-3'XO.131'NAILS 4 - 3' 14 GAUGE STAPLES FACE NAIL S. 2'SUBFLOOR TO JOIST OR GIRDER 2- 16d COMMON (3112" X 0.162") BLIND AND FACE NAIL 6. SOLE PLATE TO JOIST OR BLOCKING 16d (3 112' X 0.135") AT 16' O.C. TYPICAL FACE NAIL 3' X 0.131 NAILS AT 8" O.C. 3" 14 GAUGE STAPLES AT 12' O.C. 27. JACK RAFTER TO HIP 3 -1 Od COMMON 3 ("X 0.148') TOE NAIL 4 - 3' X 0.131 NAILS SOLE PLATE TO JOIST AT BLOCKING AT 3 -16d COMMON (3 1/2' X 0.135) AT 16" O.C. 4- 3' 14 GAUGE STAPLES BRACED WALL PANEL 4-3 ' X 0.131" NAILS AT 16" O.C. 4 - 3" 14 GAUGE STAPLES AT 16'O.C. BRACED WALLPANEL 6d 2-1 6d COMMON (3 112- X 0.162' (3 ) COMMON 3 - 3 - 3" 14 GAUGE STAPLES FACE NAIL 7. TOP PLATE TO STUD 2 -16d COMMON (3112" X 0.162') END NAIL 3-3 " X 0.131' NAILS 3 - 3.14 GAUGE STAPLES 28. ROOF RAFTER TO 2-BY RIDGE BEAM 2 -16d COMMON (3 112- X 0.162-) TOE NAIL 3-3'X 0.131 NAILS 3 - 3" 14 GAUGE STAPLES 8. STUD TO SOLE PLATE 4 - 8d COMMON (2112' X 0.131') TOE NAIL 4 - 3' X 0.131 NAILS 3 - 3.14 GAUGE STAPLES 2 -16d COMMON (3 1/7 X 0.162-) 3-3 ' X 0.131' NAILS FACE NAIL 2 -16d COMMON (3 112- X 0.162-) 3 - 3" 14 GAUGE STAPLES 3-3. X 0.131' NAILS 3 - 3" 14 GAUGE STAPLES END NAIL 29. JOIST TO BAND JOIST 3 - 16d COMMON (3 112' X 0.135-j 4-3'X0.131'NAILS 4 - 3" 14 GAUGE STAPLES FACE NAIL 9. DOUBLE STUDS 16d (3 1/2' X 0.135') AT 24" O.C. FACE NAIL 3" GA 3' 14 GAX NAILS AT O.C. GAUGE STAPLEE S AT 6' O.C. 30. LEDGER STRIP 3 -16d COMMON 3 112- X 0.162- 4 - 3' X 0.131' NAILS ) 4 " 3' 14 GAUGE STAPLES FACE NAIL AT EACH JOINT 10. DOUBLE TOP PLATES 16d (3 112- X 0.135') AT 16' O.C. TYPICAL FACE NAIL 3' X 0.131 NAILS AT 8" O.C. 3' 14 GAUGE STAPLES AT 8' O.C. 31WOOD STRUCTURAL PANELS AND . 112' AND LESS PARTICLEBOARD (B) SUBFLOOR, ROOF AND 2 3I8-X00113° NAIL (N) DOUBLE TOP PLATES 8. 16d COMMON (3 112' X 0.135") AT 16" O.C. LAP SPLICE WALL SHEATHING (TO FRAMING) 1 314-16 GAUGE(0) 12-3. X 0.131" NAILS AT 16" O.C. 12 - 3" 14 GAUGE STAPLES AT 16' O.C. 19W TO 3[4° 8d(D) OR 6tl (E) SINGLE FLOOR (COMBINATION SUBFLOOR- 2 16 GAUGE 2' 16 GAUGE (P) 6" O.C. EDGES AND INTERMEDIATE, 11. BLOCKING BETWEEN JOISTS OR RAFTERS 3 - Bd COMMON (21/2 X 0.131') TOENAIL TO TOP PLATE 3 - 3' X NAILS UNDERLAYMENT TO 19/32'TO y4' FRAMING 4' O.C. AT COMPONENT AND GAUGE 3 - 3' 14 GAUGE STAPLES 7/6" 1' Bd(C) CLADDING EDGE STRIP #ZONE 3 " T 1 118' TO 7 1/4' 10d(D) OR 8tl(D) (REFER TO FIG. 305-1 OF ASCE 7) 12. RIM JOIST TO TOP PLATE 8d COMMON (2 1/2" X 0.131") AT 6" O.C. TOENAIL 3" X 0.131" NAILS AT 6' O.C. y4' AND LESS 6tl C)) 3' 14 GAUGE STAPLES AT 6' O.C. 718' TO 1' Bd�C) 1 1/8' TO 1 1/4' 1 Dd(D) OR 8d(D) 13. TOP PLATES, LAPS AND INTERSECTIONS 2 -16d COMMON (3 112-X 0.162-) FACE NAIL 32. PANEL SIDING O FRAMING (T ) (Q ) 112' OR LESS 6d(F) 3-3 ' X 0.131' NAILS 3 - 3" 14 GAUGE STAPLES 58" 8d(F) 14. CONTINUOUS HEADER, TWO PIECES 16d COMMON 3112' X 0.16 16' O.C. ALONG EDGE 33. FIBERBOARD SHEATHING (G,Q) 112" AND LESS NO. 11 GAUGE ROOFING NAIL(H) 6d COMMON NAIL (2-4.113-) NO. 16 GAUGE 15. CEILING JOISTS TO PLATE 3-16d COMMON (31/2' X 0.131-) TOE NAIL 5 - 3' X 0.131' NAILS 25132' STAPLE (1) NO. 11 GAUGE 6-O.C. EDGES AND INTERMEDIATE 3 - 3' 14 GAUGE STAPLES NAIL(H) Bd COMMON NAIL G 1127cD.1 NO. 16 GAUGE STAAPP LE (I) 16. RIM JOIST TO TOP PLATE 4 - 8d COMMON (2 1/2-X 0.131-) TOE NAIL 17. CEILING JOISTS, LAPS OVER PARTITIONS (SEE TABLE 2308.10.4.1) 3 -16d COMMON (3 112-X 0.135-) MIN. 4-3 ' 0.131' FACE NAIL 34. INTERIOR PANELING 1/4' 4tl(J) X NAILS 4 - 3" 14 GAUGE STAPLES y8" 6d(K) 6'O.C. EDGES AND INTERMEDIATE 78. CEILING JOISTS TO PARALLEL RAFTERS 3 -16d COMMON (3 1/2' X 0.135-) MIN. FACE NAIL A. COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED. B. NAILS SPACED AT 6 INCHES ON CENTER ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES AT (SEE TABLE 2308.10.4.1) 4 - 3' X O.131' NAILS SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAGRAMS ' 4 - 3' 14 GAUGE STAPLES C.AND SHED. AR WALLS, REFER TO SECTION 2305. NAILS FOR WALL SHETHING ARE PERMITTED TO BE COMMON, BOX OR CASING. COMMO19. 3. OR DEFO)7EY8x ^. 10tl-3"x0.148"). RAFTER TO PLATE 3-Sd COMMON 0.1317 TOENAIL 3 - 3' X 0.131' NAILS EDE ORMEP HANK 6d3 0.SH�?73 Bd072112' O'1311';�Od z0.148 F. 3 - 3' 14 GAUGE STAPLES CORROSION -RESISTANT SIDING (6d - 1 7/6" x 0.106°; 8d - 2 y6' x 0.128�)) OR CASING (6d - 2' z 0 099"; 8tl - 21/2" z 0.113") NAIL G. FASTENERS SPACED 31NCHES ON CENTER AT EXTERIOR EDGES AND 61NCHES ON CENTERAT PITERMEDIATE SUPPORTS, WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 61NCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, WHEN USED FOR NONSTRUCTURAL SHEATHING. H. CORROSION -RESISTANT ROOFING NAILS WITH 7/16' DIAMETER HEAD AND 1 112" LENGTH FOR 1/2' SHEATHING AND 1 y4" LENGTH 20. 1" DIAGONAL BRACE TO EACH STUD & PLATE 2- 8d COMMON (21/2' X 0.131-) 2-3 ' X 0.131' NAILS FACE NAIL 3 - 3' 14 GAUGE STAPLES SHEATHING. FOR 1. CORROSION -RESISTANT STAPLES WITH NOMINAL 7116' CROWN OR 1' CROWN AND 1 1/4" LENGTH FOR 112" FOR 25/3Z' SHETHING PANEL SUPPORTS AT 16' (20- IF STRENGTH AXIS IS THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKEO). K.PANEL SUPPORTS AT 24%CASING OR FINISH NAILS SPACED AT 6 INCHES ON PANEL EDGES, 12 INCHES AT INTERMEDATE SUPPORTS. L. FOR ROOF SHEATHING APPLICATIONS, 8d NAILS (21/2' x 0.113") ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS. L HAVE A MINIMUM CROWN WIDTH OF 7/1 S". M. STAPLES N. OR ROOF SHEATHING APPLICATIONS, FASTENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE 21. 1"X8' SHEATHING TO EACH BEARING 3 - Bd COMMON (2 1l2' X 0.131") FACE NAIL 22. WIDER THAN 1"X8' SHEATHING TO EABEARING 3 - 6d COMMON (2 12-X 0.131-) I FACE NAIL 23. BUILT-UP CORNER SUDS 16d COMMON (3 112' X 0.162') MIN. 24' O.C. 3" X 0.131' NAILS 3' 14 GAUGE STAPLES 16" O.C. 16" O.C. SUPPORTS. O. FASTENERS SPACED AT 41NCHES ON CENTER AT EDGES, 8INCH ES AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND SHEATHING 31NCHES ON CENTER AT EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING. P. FASTENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS. Q. SEE FASTENER ALTERNATE SCHEDULE R FASTENERS MUST BE INSTALLED WITH EVEN SPACING BETWEEN THEM ACROSS ATTACHING MEMBER. ALTERNATE FASTENING SCHEDULE CONNECTION FASTENING ALT 3133. WOOD STRUCTURAL PANELS AND PARTICLEBOARD SUBFLOOR, ROOF AND WALL SHEATHING (TO FRAMING) I 12" AND LESS 1 2- X 0.092- RING SHANK NAIL 5' FROM EDGE, 10- O.C. ' TOP LINE ENGINEERING. LLC 1L; STRUCTURAL ENGINEERS William E. Neary, III SIVIP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 MODULAR PLANS DESIGN, CO. CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZ PE LICENSE #38769 MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE., SUITE 105 OFFICE 863.688.1054 LAKELAND. FLORIDA FM: 863.688.7118 33813 COLE@MODULARPLANSCO.COM LVL I-UL-uo IUt' LINt r-INI.7IINCCKIINv )L\rrKUV/-\L t'LAIN iE 1:5UNv-HVHZ-1U �-> HVHL Af FROVED