HomeMy WebLinkAboutResponse to CommentsBURGOS
LANZA
ARCHITECTS & PLANNERS
AR 0016081
1245 SOUTH ALAAMBRA'CIRCLE - CORAI. GABLES, FLOR113A 33136 (786) 236-5419
-BUILDING DEPARTMENT RESPONSE
Planning B Developnierit Services REVIEW COMMENTS
Building a% Code RegiutgOon,Division
2300 VirglnloAvenue,
Fort Pierce: FL `34982-
Page 1
PROPERTY /NFORMAT/ON
Address: 4845 Watersong Way Owner(s):
Carlos Lanza (Tr)
City / State / Zip: Fort Pierce, F1,34949
Parcel #: 2532-500-0024-000/9 Jurisdiction: SAINT LUCIE COUNTY
Zoning: Lot#: 10 Block:
APPLICATION /NFORMATlON '
Permit Number 12012-0614 Stories: Automatic Sprinkler System? No
Permit Type: BUILDING RESIDENTIAL,(SFR UP TO 2 FLOORS)
CONTRACTOR /NFORMAT/ON, '
Contractor Name:' '
Business Name:Business Addr: City / State'/ Zip:
DOCUMENTS MISSINGPENDING. Lashahna Ingram
12/28/2020 Comment: NEEDS TO SUBMIT FILLED LANDS
12/28/2020 Comment: SUB CONTRACTOR AGREEMENTS FOR ALL TRADES RESPONSE: ATTACHED
12/28/2020 Comment: NEEDS TO SUBMIT DRIVEWAY PERMIT RESPONSE: WAS INFORMED THAT
DRIVEWAY PERMIT WASN'T REQUIRED DUE TO PROPERTY BEING'ON PRIVATE
ROAD
ENVIRONMENTAL REVIEW INCOMPLETE Lynn Swarb l 12/30/2020
1/4/2021 Comment: NEED COPY OF SURVEY WITH PROPOSED BUILDING. RESPONSE: ATTACHED
ZONING REVIEW INCOMPLETE .'Angela Vassar
/2 /2021 Comment: RECEIVED SURVEYS; HOW EVER INFORMATION IS STILL MISSING. PLEASE SHOW THE
PROPOSED RESIDENCE WITH'MEASUREMENTS (SURVEY MUST MATCH THE FLOOR PLAN);
SETBACKS TO ALL PROPERTY LINES; FLOOD INFORMATION IN NOTES; FLOOD,ZONES ON
PROPERTY (IF THERE IS MORETHAN ONE FLOOD ZONE SHOW THEM ON THE PROPERTY)
PROPOSED FINISHED FLOOR ELEVATION; ELEVATION OF CENTERLINE OF ADJACENT
ROADWAY; CONVERSION FROM NGVD TO NAVD. THE SURVEYMUST BE SIGNED AND
RAISED SEALED BY A FLORIDA REGISTERED SURVEYOR. RESPONSE:'REVISED SURVEY
ATTACHED
6/28/2021 Comment: PLEASE PROVIDE DER LETTER. RESPONSE: EMAIL FROM DER EXEMPTI.NG`PERMIT
REQUIREMENT ATTACHED
PE REVIEW COMMENTS (2), INCOMPLETE William Durden 612512021_.
6/25/2021 Comment: SUBMITTED DOCUMENTS REQUIRING SEALS WERE STILL SUBMITTED WITH DIGITAL.SEALS.
PLANS AND DOCUMENT THAT REQUIRE A SEALAND SIGNATURE MUST'BE'SUBMITTED WITH
WET OR RAISED SEALS AND ORIGINAL SIGNATURES. PLEASE CORRECT AND'RESUBMIT SEE
SECTION 107 OF THE2017 FLORIDA BUILDING CODE.
RESPONSE: ALL DOCUMENTS HAVE'BEEN CORRECTED
BURGOS
LANZA
ARCHMEM & MANNERS
AR 0016081
1245 SOUTH ALIiANIBRA CIRCLE - CORAL GABLES, FLORIDA 33136 (786) 236-5419
BUILDING DEPARTMENT RESPONSE
Address: 4845 Watersong Way Owner(s):
Carlos Lanza (Tr)
City / State / Zip: Fort Pierce, FI 34949
Parcel #: 2532-500-0024-000/9 Jurisdiction: SAINT LUCIE COUNTY
Zoning:
Lot#: 10
APPLICATION INFORMATION
Permit Number: 2012-0614 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Carlos Lanza
Business Name:
Cl Contractors Corp
Business Addr:
8531 Sw 167 Terr
City / State / Zip:
Miami, FI 33157
REVIEWS AND COMMENTS
Review Tyne
DOCUMENTS MISSING
12/28/2020 Comment:
12/28/2020 Comment:
12/28/2020 Comment:
ENVIRONMENTAL REVIEW
1/4/2021 Comment:
FRONT COUNTER REVIEW
Comment:
NOTIFIED FOR PICK UP
Block:
Automatic Sprinkler System? No
Fax Number:
Email: Clcontractorst?a Comcast.Net
Status Reviewed By Date Started Date Completed Date Released
PENDING Lashahna Ingram
NEEDS TO SUBMIT FILLED LANDS Response : Attached
SUB CONTRACTOR AGREEMENTS FOR ALL TRADES Response : Attached
NEEDS TO SUBMIT DRIVEWAY PERMIT Response : Was informed not required since its private road
INCOMPLETE Lynn Swartzel 12/30/2020
NEED COPY OF SURVEY WITH PROPOSED BUILDING.
COMPLETE Lashahna Ingram 12/28/2020 12/28/2020 12/28/2020
PENDING
Comment:
PLANS EXAMINER REVIEW OCOMPLETE William Durden 1/14/2021
1/14/2021 Comment. SUBMITTED PLANS ARE NGVD. PLEASE REVISE PLANS TO REFLECT NAVD. Response: Corrected on ,all pages
1/14/2021 Comment:/ UNABLE TO REVIEW SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE FOR FLOOD
/REQUIREMENTS. PLANS ARE IN NGVD. Response : Acknowledged '
Comment: UNABLE TO REVIEW SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE FOR FLOOD
1/14/2021 REQUIREMENTS FOR THE LOWEST HORIZONAL STRUCTURAL MEMBER. PLEASE SUBMIT THE FDEP
DOCUMENTS FOR THE LOWEST HORIZONAL STRUCTURAL MEMBERS ELEVATION. SEE SECTION 107 OF
THE 2017 FLORIDA BUILDING CODE.
Response: Residence not located seaward of CCCL. FEMA AE +6.00 NAVD
Comment: 1. FLORIDA PRODUCT APPROVAL FL22378.11 SHOWS +55.0/-50.5, PRODUCT REVIEW AFFIDAVIT ON
THE PLANS SHOW-60/+60 FOR THE PRODUCT APPROVAL. PLEASE CORRECT INFORMATION AND
RESUBMIT. RESPONSE: CORRECT ON SHT A2.00
2. FLORIDA PRODUCT APPROVAL FL22378.13 SHOWS +47.0/-45.5, PRODUCT REVIEW AFFIDAVIT ON
THEPLANS SHOW-55/+55 FOR THE PRODUCT APPROVAL. PLEASE CORRECT INFORMATION AND
RESUBMIT. RESPONSE: CORRECT ON SHT A2.00
3. NOA 19-0709.07 SHOWS 161 PERIMETER AND 84.5 PSF FIELD. PRODUCT REVIEW AFFIDAVIT
SHOWS 84.25 PSF FOR THE FIELD. PLEASE CORRECT AND RESUBMIT.
RESPONSE: CORRECT ON SHT A2.00
4. TRUSS PLACEMENT DRAWINGS WERE SUBMITTED WITHOUT TRUSS ENGINEERING PLEASE
SUBMIT THE TRUSS ENGINEERING IN DUPLICAT WITH RAISED OR WET SEAL AND ORIGINAL
SIGNATUREFROM THE MANUFACTURES ENGINEERING DEPARTMENT REVIEWED AND APPROVED
BY THE DESIGN PROFESSIONAL IN CHARGE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING
CODE. RESPONSE: NEW SIGNED AND SEALED DRAWINGS ATTACHED
5. LINE SEVEN IS STILL INCORRECT. MULTIPLE GLAZED OPENINGS. PLEASE SUBMIT THE ENERGY
PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION MANUFACTURE CERTIFICATE FOR
THE U- FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH
CHAPTER 4 SECTION 402.1.1 OF THE 2017 ENERGY CODE SIXTH EDITION. TO THE ENERGY
COMPANY WHO CREATED THE ENERGY CALC FOR REVIEW, PLEASE SUBMIT CORRECTED ENERGY
CALCS IN DUPLICATE. RESPONSE: CORRECT ON SHT A2.00
6. HOLLOW CORE DECK SHOP DRAWINGS WERE SUBMITTED WITH A DIGITAL SEAL. PLANS
SUBMITTED IN PAPER FORM MUST HAVE THE RAISED OR WET SEAL WITH ORIGINAL SIGNATURES.
PLEASE SUBMIT CORRECTED DOCUMENTS. SEE SECTION107 OF THE 2017 FLORIDA BUILDING
CODE. RESPONSE: NEW SIGNED AND SEALED DRAWINGS ATTACHED
7. PLEASE NOTE I AM WAVING THE PLAN REVISION RESUBMITTAL FEE OF $63.75. THIS IS A ONE
TIME WAVER OF THE FEES. RESPONSE: ACKNOWLEDGED AND THANK YOU
PLEASE NOTE:
(1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING
WHERE THE CHANGES WERE MADE. RESPONSE: COVER LETTER PROVIDED
(2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS.
RESPONSE: ACKNOWLEDGED
(3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED
PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS
CAN BE SUBMITTED. RESPONSE: ACKNOWLEDGED
(4) A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF
DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR.
RESPONSE: CHECKLIST PROVIDED
(5) ANY COMMENT NOT ADDRESSED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST.
LUCIE COUNTY RESOLUTION #13-196. RESPONSE: ACKNOWLEDGED
Do not hesitate to call if we can be of further assistance.
Best regards,
Ca4l-T,ak La4/Lr5v
Carlos Lanza, RA
Burgos Lanza & Associates
J
i_
SUBMITTAL CHECKLIST
PLANS: SHEETS BEING RE -SUBMITTED AND CHANGES
A0.00 COVER SHEET— UPDATING REVISION DATES
A1.00 SITE PLAN — FINISH FLOOR ELEVATION RAISED AND METER RELOCATED
A1.02 NOTES AND DIAGRAMS — ELIMINATED UNNECESSARY NOTES
A2.00 PROPOSED GROUND FLOOR — FINISH FLOOR ELEVATION RAISED. PRODUCT REVIEW
AFFIDAVIT REVISED, NFRC CERTIFIED PRODUCT DIRECTOR ADDED
A2.01 PROPOSED SECOND AND THIRD FLOOR — FINISH FLOOR ELEVATION CORRECTED
A2.02 PROPOSED ROOF PLAN — ROOF BEAM COORDINATED, SECTIONS FINISH FLOOR
ELEVATIONS CORRECTED
A3.00 PROPOSED ELEVATIONS - FINISH FLOOR ELEVATIONS CORRECTED
A3.01 PROPOSED ELEVATIONS - FINISH FLOOR ELEVATIONS CORRECTED
A4.00 SECTIONS - FINISH FLOOR ELEVATIONS CORRECTED
A4.01 SECTIONS - FINISH FLOOR ELEVATIONS CORRECTED
A6.00 BLOWUP STAIRS - FINISH FLOOR ELEVATIONS CORRECTED
E1.01 ELECTRICAL FLOOR PLANS — CORRECTED LIGHTING IN SHOWER TO VP
L1.00 LANDSCAPING PLAN — CHANGED TREE DESIGNATION TO MATCH ASSOCIATION
SUBMITTAL
M1.01 MECHANICAL FLOOR PLAN — CHANGED SIZES OF DIFFUSERS
P1.01 PLUMBING FLOOR PLAN — CORRECTED WATER DISTRIBUTION
P1.02 SANITARY FLOOR PLAN — CORRECTED SANITARY DISTRIBUTION
S1.02 GROUND FLOOR STRUCTURAL - FINISH FLOOR ELEVATIONS CORRECTED
S1.03 SECOND & THIRD FRAMING PLAN - FINISH FLOOR ELEVATIONS CORRECTED
S1.04 ROOF FRAMING PLAN — COORDINATED FRAMING WITH TRUSS SHOP DRAWINGS
ADDITIONAL SUBMITTALS:
SIGNED AND SEALED TRUSS SHOP DRAWINGS (2 SETS)
SIGNED AND SEALED HOLLOW CORE SLAB SHOP DRAWINGS (2 SETS)
SIGNED AND SEALED SURVEY (2 SETS)
SIGNED AND, SEALED CERTIFICATION FOR DESIGN LOAD COMPLIANCE (2 SETS)
SIGNED AND SEALED ENERGY CALCULATIONS (2 SETS)
SIGNED AND SEALED GARAGE WINDLOAD CALC (2 COPIES)
DEP EMAIL STATING PROPERTY EXEMPT FROM PERMIT (2 EMAILS & 2 COPIES)
SUB CONTRACTOR AGREEMENT (PLUMBER, ELECTRICTIAN, MECHANICAL)
Regards
Caros Lanza, RA 8/15/2021
8531 SW 167 Terrace • Palmetto Bay, FL 33157
756.236.5419
cicontractors@oomcast.net