HomeMy WebLinkAboutReview CommentsPlanning S Cevelegre�eoat'Seritic�s.. Ouilding &Cod6 Regu1MomOlvlsiran 2300 VJrglnla Avvnpo For Perm Fl, W82 PROPERTY INFORMATION Address: 4845 Watersong Way City / State / Zip: Fort Pierce, FI 34949 Parcel #: 2532-500-0024-000/9 Zoning: REVIEW COMMENTS Owner(s): Carlos Lanza (Tr) Jurisdiction: SAINT LUCIE COUNTY Lot#: 10 Block: APPLICATION INFORMATION Permit Number: 2012-0614 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Carlos Lanza Business Name: Cl Contractors Corp Business Addr: 8531 Sw 167 Terr City / State / Zip: Miami, FI 33157 REVIEWS AND COMMENTS 1 Automatic Sprinkler System? No Fax Number: Review Tvoe Status Reviewed By Date Started DOCUMENTS MISSING PENDING Lashahna Ingram 12/28/2020 Comment: NEEDS TO SUBMIT FILLED LANDS 12/28/2020 Comment: SUB CONTRACTOR AGREEMENTS FOR ALL TRADES 12/28/2020 Comment: NEEDS TO SUBMIT DRIVEWAY PERMIT ENVIRONMENTAL REVIEW INCOMPLETE Lynn Swartzel 12/30/2020 1/4/2021 Comment: NEED COPY OF SURVEY WITH PROPOSED BUILDING. FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 12/28/2020 Comment: NOTIFIED FOR PICK UP PENDING Comment: PLANS EXAMINER REVIEW 1/14/2021 Comment: 1/14/2021 Comment: Comment: 1/14/2021 Email: Clcontractors@Comcast.Ne t Date Completed Date Released 12/2812020 12/28/2020 INCOMPLETE William Durden 1/14/2021 SUBMITTED PLANS ARE NGVD. PLEASE REVISE PLANS TO REFLECT NAVD. UNABLE TO REVIEW SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE FOR FLOOD REQUIREMENTS. PLANS ARE IN NGVD. UNABLE TO REVIEW SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE FOR FLOOD REQUIREMENTS FOR THE LOWEST HORIZONAL STRUCTURAL MEMBER. PLEASE SUBMIT THE FDEP DOCUMENTS FOR THE LOWEST HORIZONAL STRUCTURAL MEMBERS ELEVATION. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Planning & DevelopmentServices Building t Codi ftulabon Diviiion 230Q Vlrglnla Avenue fort,Plerea,.FL,, 34982 REVIEW COMMENTS Page 2 Comment: SUBMITTED PLANS ARE COPIES WITH DIGITAL SIGNATURE AND SEALS. • IF THE A DOCUMENT IS SUBMITTED WITH A DIGITAL SIGNATURE THE DOCUMENT MUST BE SUBMIT AS A DIGITAL SUBMISSION 1/14/2021 WITH THE ORIGINAL SIGNATURE. IF THE DOCUMENTS ARE SUBMITTED IN PAPER FORM IT MUST HAVE THE RAISED OR WET SEAL WITH THE ORIGINAL SIGNATURE. PLEASE RESUBMIT. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: PLANS ARE INUNDATED WITH CODE SECTIONS. PLEASE REMOVE THE SECTIONS THAT DO NOT PERTAIN 1/14/2021 TO THE CONSTRUCTION OF THE PROPOSED STRUCTURE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: PAGE A1.01, NOTE SECTION SPECIFIES WINDOW AND DOORS BY OTHER, SEPARATE PERMIT. PLEASE 1/14/2021 REMOVE THIS SECTION AND ADD THE PRODUCT REVIEW AFFIDAVIT TO THE PLANS WITH THE INSTALLATION INSTRUCTIONS COMPLETED. OR ADD THE PRODUCT APPROVALS FOR THE WINDOWS AND DOORS. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. 1/14/2021 Comment: PLEASE SUBMIT A GEOTECHNICAL EVALUATION WITH THE FOUNDATION RECOMMENDATIONS. (SOIL BORING TEST),SEE SECTION R401.4 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/14/2021 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 8 SECTION R802 SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 1/14/2021 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61 G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. 1/15/2021 Comment: • ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION 405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE. Comment: • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED 1/15/2021 OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Comment: • LINE EIGHT ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/1512021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Comment: • LINE NINE ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Comment: • LINE TEN ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Comment: PLEASE ADD THE CUBIC VOLUME ON THE PLANS. THE PLANS SHOULD MATCH THE CUBIC VOLUME SPECIFIED ON THE ENERGY CALC'S. THE CUBIC VOLUME NUMBER IS USED IN THE CALCULATIONS FOR THE BLOWER DOOR TESTING. PLEASE CHECK WITH THE COMPANY THAT CALCULATED THE CUBIC 1/15/2021 VOLUME ON THE ENERGY CALC'S AND THE DESIGN PROFESSIONAL TO COLLATE THE CUBIC VOLUME. THE NUMBER SHOULD INCLUDE THE ATTIC SPACE AS THE SPRAY FOAM INSULATION IS INSTALLED TO THE ROOF DECK AND IS NOT VENTED. THIS IS CONSIDERED CONDITIONED SPACE. SEE SECTION CHAPTER 2 DEFINITION OF CONDITION SPACE OF THE 2017 FLOR IDA ENERGY CODE. 1/15/2021 Comment: PLEASE CLARIFY NOTE ON PAGE A1.02 FOR THE AS -BUILT ELEVATION DOCUMENTATION. WILL YOU BE SUPPLYING AS BUILT DRAWINGS? Comment: PLANS CALL OUT AN ELEVATOR TO BE INSTALLED. PLEASE SUBMIT THE ELEVATORS MANUFACTURES 1/15/2021 SHOP DRAWINGS AND INSTALLATION INSTRUCTIONS. MEETING THE REQUIREMENTS OF R321 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: PLEASE ADD TO THE PLANS THE SQUARE FOOT CALCULATION FOR THE ENCLOSED AREAS BELOW 1/15/2021 FLOOD TO DETERMINE THE MINIMUM NUMBER OF FLOOD VENTS REQUIRED FOR EACH AREA ENCLOSED BELOW FLOOD. SEE SECTION R322.2.2 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/16/2021 Comment: NO DETAIL SHOW ON THE PLANS FOR THE STAIRS. PLEASE ADD THE STAIR DETAILS TO THE PLANS IN COMPLIANCE WITH R311.7 AND CHAPTER 322 OF THE 2017 FLORIDA BUILDING CODE. 1/15/2021 Comment: PLEASE SEE THE WALL SECTIONS ON PAGE A2.02 OF THE PLANS. I AM UNABLE TO DETERMINE COMPLIANCE WITH R322.1.8 FOR FLOOD RESISTANT MATERIALS. Comment: ELEVATOR DETAILS SHOW WOOD CONVENTIONAL CONSTRUCTION. I AM UNABLE TO DETERMINE IF THE ELEVATORS CONSTRUCTION WILL NEED TO MEET THE REQUIREMENTS OF R322.1.8 DUE TO MISSING OR 1/15/2021 INCORRECT ELEVATION INFORMATION. IF THE LOWER PORTION OF THE ELEVATOR TOWER IS BELOW FLOOD IT WILL NEED TO MEET THE REQUIREMENTS OF R322.1.8 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/15/2021 Comment: PLEASE SEE SECTION R322.3.6 OF THE 2017 FLORIDA BUILDING CODE. PLEASE ADD TO THE PLANS THAT THE DESIGN AND METHODS OF CONSTRUCTION MEETS THE REQUIREMENT OF THIS SECTION. 1/15/2021 Comment: PLANS SHOW HOLLOW CORE DECKING. PLEASE SUBMIT THE MANUFACTURERS SHOP DRAWINGS AND PLACEMENT PLAN FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Planning ii 06volopmeot terviC8 • SuiidRig &'C6de:Regu1Mon Division 23gq Virginia Avenue, fortPtem%,FL, 346k REVIEW COMMENTS Page 3 Comment: SEE PAGE E1.01. ELECTRICAL DRAWINGS SHOW ELECTRICAL ITEMS ATTACHED TO BREAKAWAY WALLS. 1/15/2021 PLEASE SUBMIT CORRECTED ELECTRICAL PAGE IN COMPLIANCE WITH R322.3.4 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 1/15/2021 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. 1/15/2021 Comment: PLEASE NOTE ALL CORRECTION WILL NEED TO BE IDENTIFIED WITH A CORRECTION REPORT FROM THE DESIGN PROFESSIONAL, AND CLOUDING THE AREAS CORRECTED FOR RESUBMISSION. ZONING REVIEW INCOMPLETE Angela Vassar 1/7/2021 Comment: PLEASE PROVIDE TWO SIGNED AND SEALED SURVEYS SHOWING THE MEASUREMENTS OF THE PROPOSED RESIDENCE. PER CHAPTER 11.05.01 OF THE ST LUCIE COUNTY LAND DEVELOPMENT CODE ALL SURVEYS SHALL COMPLETELY DEPICT THE FOLLOWING: 17HE LOCATION OF THE PROPOSED DEVELOPMENT ACTIVITY 2.THE RELATIONSHIP OF THE ACTIVITY UNDER APPLICATION TO ALL ADJACENT PROPERTY LINES, AND AS MAY BE REQUIRED FOR THE REVIEW OF THE APPLICATION, ALL ADJACENT STRUCTURES, IMPROVEMENTS OR NATURAL FEATURES 3.A MINIMUM OF TWO (2) ELEVATIONS ALONG EACH ROADWAY ON WHICH THE PROPOSED ACTIVITY BORDERS, THE EXISTING GROUND ELEVATION AT THE APPROXIMATE CENTER OF THE PROPOSED STRUCTURE, THE EXISTING GROUND ELEVATION ALONG THE SIDE PROPERTY LINES ADJACENT TO THE PROPOSED STRUCTURE, AND THE PROPOSED FINISHED FLOOR ELEVATION OF THE STRUCTURE UNDER APPLICATION. ALL ELEVATIONS ARE TO BE BASED UPON NAVD; AND, EXCEPT FOR DETACHED SINGLE 1/7/2021 FAMILY RESIDENTIAL LOTS OR PARCELS OF LAND HAVING AN AREA OF ONE (1) ACRE OR LESS 4.THE LOCATION OF ALL NATIVE TREES OF 20 INCHES DBH AND GREATER, WITH THE SPECIFIC DIAMETER AND TYPE OF TREE CLEARLY IDENTIFIED. ALL SURVEYS SUBMITTED SHALL HAVE BEEN BE PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED LAND SURVEYOR, IN ACCORDANCE WITH THE CURRENT PROVISIONS OF CHAPTER 61G17-6, FAC, EXCEPT THAT APPLICATIONS FOR INTERIOR MODIFICATIONS OR CONSTRUCTION, ROOFING PERMITS NOT INVOLVING ANY STRUCTURAL ALTERATION OR ADDITIONS TO THE AREA COVERED BY THE ROOF SURFACE, OR ANY OTHER PERMIT REQUIRED ACTIVITY THAT DOES NOT RESULT IN THE EXPANSION OF ANY PORTION OF THE EXISTING STRUCTURES SHALL NOT BE REQUIRED TO SUBMIT SURVEYS. PLEASE SHOW THE COASTAL CONSTRUCTION CONTROL LINE ON THE SURVEY; PLEASE BE AWARE IF ANY OF THE STRUCTURE LIES EAST OF THE COASTAL CONSTRUCTION CONTROL LINE A DEP PERMIT WILL BE REQUIRED. 1/7/2021 Comment: PLEASE BE AWARE THESE ARE PRELIMINARY COMMENTS; THERE MAY BE MORE ZONING REVIEW COMMENTS AFTER THE SURVEY IS OBTAINED. 1/7/2021 Comment: THE PLAN REVIEWER MAY HAVE ADDITIONAL COMMENTS. i Planning & Development Services REVIEW COMMENTS Building R Code'Regula€ion Division 2300 Virginia Avenue Fort Piece. FL. 34982 Page 3 Comment: SEE PAGE E1.01. ELECTRICAL DRAWINGS SHOW ELECTRICAL ITEMS ATTACHED TO BREAKAWAY WALLS 1/15/2021 PLEASE SUBMIT CORRECTED ELECTRICAL PAGE IN COMPLIANCE WITH R322.3.4 OF THE 2017 FLORID RESIDENTIAL BUILDING CODE. ), Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 1/15/2021 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED. - DOCUMENTS. Comment: PLEASE NOTE ALL CORRECTION WILL NEED TO BE IDENTIFIED WITH A CORRECTION REPORT FROM THE 1/15/2021 DESIGN PROFESSIONAL, AND CLOUDING THE AREAS CORRECTED FOR RESUBMISSION. ZONING REVIEW INCOMPLETE Angela Vassar 1/7/2021 Comment: PLEASE PROVIDE TWO SIGNED AND SEALED SURVEYS SHOWING THE MEASUREMENTS OF THE PROPOSED RESIDENCE. PER CHAPTER 11.05.01 OF THE ST LUCIE COUNTY LAND DEVELOPMENT CODE ALL SURVEYS SHALL COMPLETELY DEPICT THE FOLLOWING: 13HE LOCATION OF THE PROPOSED DEVELOPMENT ACTIVITY 23HE RELATIONSHIP OF THE ACTIVITY UNDER APPLICATION TO ALL ADJACENT PROPERTY LINES, AND AS MAY BE REQUIRED FOR THE REVIEW OF THE APPLICATION, ALL ADJACENT STRUCTURES, IMPROVEMENTS OR NATURAL FEATURES 3.A MINIMUM OF TWO (2) ELEVATIONS ALONG EACH ROADWAY ON WHICH THE PROPOSED ACTIVITY r BORDERS, THE EXISTING GROUND ELEVATION AT THE APPROXIMATE CENTER OF THE PROPOSED STRUCTURE, THE EXISTING GROUND ELEVATION ALONG THE SIDE PROPERTY LINES ADJACENT TO THE PROPOSED STRUCTURE, AND THE PROPOSED FINISHED FLOOR ELEVATION OF THE STRUCTURE UNDER APPLICATION. ALL ELEVATIONS ARE TO BE BASED UPON NAVD; AND, EXCEPT FOR DETACHED SINGLE FAMILY RESIDENTIAL LOTS OR PARCELS OF LAND HAVING AN AREA OF ONE (1) ACRE OR LESS 1/7/20121 47HE LOCATION OF ALL NATIVE TREES OF 20 INCHES DBH AND GREATER, WITH THE SPECIFIC DIAMETER AND TYPE OF TREE CLEARLY IDENTIFIED. ALL SURVEYS SUBMITTED SHALL HAVE BEEN BE PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED LAND SURVEYOR, IN ACCORDANCE WITH THE CURRENT PROVISIONS OF CHAPTER 61G17-6, FAC, EXCEPT THAT APPLICATIONS FOR INTERIOR MODIFICATIONS OR CONSTRUCTION, ROOFING PERMITS NOT INVOLVING ANY STRUCTURAL ALTERATION OR ADDITIONS TO THE AREA COVERED BY THE ROOF SURFACE, OR ANY OTHER PERMIT REQUIRED ACTIVITY THAT DOES NOT RESULT IN THE EXPANSION OF ANY PORTION OF THE EXISTING STRUCTURES SHALL NOT BE REQUIRED TO SUBMIT SURVEYS. PLEASE SHOW THE COASTAL CONSTRUCTION CONTROL LINE ON THE SURVEY; PLEASE BE AWARE IF ANY OF THE STRUCTURE LIES EAST OF THE COASTAL CONSTRUCTION CONTROL LINE A DEP PERMIT WILL BE REQUIRED. Comment: PLEASE BE AWARE THESE ARE PRELIMINARY COMMENTS; THERE MAY BE MORE ZONING REVIEW 1/7/2021 COMMENTS AFTER THE SURVEY IS OBTAINED. 1 /712021 Comment: THE PLAN REVIEWER MAY HAVE ADDITIONAL COMMENTS. Plannin9 E Develop ment Services BtflIding & Coda Regulation Division 2300 Virglnla Avenues FortPi ease, FL. V.482 REVIEW COMMENTS I' Page 2 St1RMITTFI) PI ANS ARF CnPIFS WITH nIC;ITAI RIANATI IRF ANn RFAI R . IF THE A nnfa IMFNT 1A SUBMITTED WITH A DIGITAL SIGNATURE THE DOCUMENT MUST BE SUBMIT AS A DIGITAL SUBMISSION 1/14/2021 WITH THE ORIGINAL SIGNATURE. IF THE DOCUMENTS ARE SUBMITTED IN PAPER FORM IT MUST HAVE THE RAISED OR WET SEAL WITH THE ORIGINAL SIGNATURE. PLEASE RESUBMIT. SEE SECTION 107 OF /T' HE 2017 FLORIDA BUILDING CODE. Comm' ' enPLANS ARE INUNDATED WITH CODE SECTIONS. PLEASE REMOVE THE SECTIONS THAT DO NOT PERTAIN 1/1412021 TO THE CONSTRUCTION OF THE PROPOSED STRUCTURE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. �j—/ Comment: PAGE A1.01, NOTE SECTION SPECIFIES WINDOW AND DOORS BY OTHER, SEPARATE PERMIT. PLEASE a�14/2021 REMOVE THIS SECTION AND ADD THE PRODUCT REVIEW AFFIDAVIT TO THE PLANS WITH THE ,00'` INSTALLATION INSTRUCTIONS COMPLETED. OR ADD THE PRODUCT APPROVALS FOR THE WINDOWS AND DOORS. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. 1/14/2021 Comment: PLEASE SUBMIT A GEOTECHNICAL EVALUATION WITH THE FOUNDATION RECOMMENDATIONS. (SOIL ✓ BORING TEST),SEE SECTION R401.4 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/14/202,1 ,oj / Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 8 SECTION R802 SUBSECTION C"" V ! R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comments • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND✓ 111412.021 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. 1/15/2021 Comment: ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION'v 05.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE. r— C:ommentV • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED 1/15/2021 OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Comment: • LINE EIGHT ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH W EDITION. Comment: • LINE NINE ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH � EDITION. Comment: • LINE TEN ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY✓ 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Comment: PLEASE ADD THE CUBIC VOLUME ON THE PLANS. THE PLANS SHOULD MATCH THE CUBIC VOLUME SPECIFIED ON THE ENERGY CALC'S. THE CUBIC VOLUME NUMBER IS USED IN THE CALCULATIONS FOR,,,,' THE BLOWER DOOR TESTING. PLEASE CHECK WITH THE COMPANY THAT CALCULATED THE CUBIC 1/15/2021 VOLUME ON THE ENERGY CALC'S AND THE DESIGN PROFESSIONAL TO COLLATE THE CUBIC VOLUME. THE NUMBER SHOULD INCLUDE THE ATTIC SPACE AS THE SPRAY FOAM INSULATION IS INSTALLED TO THE ROOF DECK AND IS NOT VENTED. THIS IS CONSIDERED CONDITIONED SPACE. SEE SECTION CHAPTER 2 DEFINITION OF CONDITION SPACE OF THE 2017 FLORIDA ENERGY CODE. ✓ 1/15/2021 SUPPLYING ` PLEASE CLARIFY NOTE ON PAGE A1.02 FOR THE AS -BUILT ELEVATION DOCUMENTATION. WILL YOU BE V SUPPLYING AS BUILT DRAWINGS? Comment: PLANS CALL OUT AN ELEVATOR TO BE INSTALLED. PLEASE SUBMIT THE ELEVATORS MANUFACTURES 1/15/2021 SHOP DRAWINGS AND INSTALLATION INSTRUCTIONS. MEETING THE REQUIREMENTS OF R321 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: PLEASE ADD TO THE PLANS THE SQUARE FOOT CALCULATION FOR THE ENCLOSED AREAS BELOW 1/15/2021 FLOOD TO DETERMINE THE MINIMUM NUMBER OF FLOOD VENTS REQUIRED FOR EACH AREA ENCLOSE BELOW FLOOD. SEE SECTION R322.2.2 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. 1/15/2021 Comment: NO DETAIL SHOW ON THE PLANS FOR THE STAIRS. PLEASE ADD THE STAIR DETAILS TO THE PLANS IN COMPLIANCE WITH R311.7 AND CHAPTER 322 OF THE 2017 FLORIDA BUILDING CODE. , 1/15/2021 Comment: PLEASE SEETHE WALL SECTIONS ON PAGE A2.02 OF THE PLANS. I AM UNABLE TO DETERMINE � ��' COMPLIANCE WITH R322.1.8 FOR FLOOD RESISTANT MATERIALS. Comment: ELEVATOR DETAILS SHOW WOOD CONVENTIONAL CONSTRUCTION. I AM UNABLE TO DETERMINE IF THE ELEVATORS CONSTRUCTION WILL NEED TO MEET THE REQUIREMENTS OF R322.1.8 DUE TO MISSING OR 1/15/2021 INCORRECT ELEVATION INFORMATION. IF THE LOWER PORTION OF THE ELEVATOR TOWER IS BELOW- / FLOOD IT WILL NEED TO MEET THE REQUIREMENTS OF R322.1.8 OF THE 2017 FLORIDA RESIDENTIAL y BUILDING CODE. ' 1/15/2021 Comment: PLEASE SEE SECTION R322.3.6 OF THE 2017 FLORIDA BUILDING CODE. PLEASE ADD TO THE PLANS THAT THE DESIGN AND METHODS OF CONSTRUCTION MEETS THE REQUIREMENT OF THIS SECTION. 1/151202.1 Commen PLANS SHOW HOLLOW CORE DECKING. PLEASE SUBMIT THE MANUFACTURERS SHOP DRAWINGS AND PLACEMENT PLAN FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. /4 _ ,r Planning & Development Services Building & Coda ReQUIB ion Division 2 300 Vic ginia Avenue* Fort Pierce, FL. 34982 PROPERTY INFORMATION Address: 4845 Watersong Way City I State I Zip: Fort Pierce, FI 34949 Parcel #: 2532-500-0024-000/9 Zoning: REVIEW COMMENTS Owner(s): Carlos Lanza (Tr) Jurisdiction: SAINT LUCIE COUNTY Lot#: 10 Block: APPLICATION INFORMATION Permit Number: 2012-0614 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Carlos Lanza Business Name: Cl Contractors Corp Business Addr: 8531 Sw 167 Terr City / State / Zip: Miami, FI 33157 REVIEWS AND COMMENTS Page 1 Automatic Sprinkler System? No Fax Number: Review Type Status Reviewed By Date Started DOCUMENTS MISSING PENDING Lashahna Ingram 12/28/2020 Comment: NEEDS TO SUBMIT FILLED LANDS 12/28/2020 Comment: SUB CONTRACTOR AGREEMENTS FOR ALL TRADES 12/28/2020 Comment: NEEDS TO SUBMIT DRIVEWAY PERMIT ENVIRONMENTAL REVIEW INCOMPLETE Lynn Swartzel 12/30/2020 1/4/2021 Comment: NEED COPY OF SURVEY WITH PROPOSED BUILDING. FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 12/28/2020 Comment: NOTIFIED FOR PICK UP PENDING Comment: PLANS EXAMINER REVIEW 1/14/2021 Comment: 1/14/202.1 Comment: ,Comment: 1 /14/2021 INCOMPLETE William Durden 1/14/2021 Email: Clcontractors@Comcast.Ne t Date Completed Date Released 12128/2020 12/28/2020 SUBMITTED PLANS ARE NGVD. PLEASE REVISE PLANS TO REFLECT NAVD. &'*'� UNABLE TO REVIEW SECTION 322 OF THE 017 FLORIDA RESIDENTIAL BUILDING CODE FOR FLOOD REQUIREMENTS. PLANS ARE IN NGVD. UNABLE TO REVIEW SECTION 322 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE FOR FLOOD REQUIREMENTS FOR THE LOWEST HORIZONAL STRUCTURAL MEMBER. PLEASE SUBMIT THE FDEP DOCUMENTS FOR THE LOWEST HORIZONAL STRUCTU AL MEMBERS ELEVATION. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. , (J �)j . 0 C c L Planning & Development Services REVIEW COMMENTS Building&:Code Regulation Division 230D Virginia Avenue Fort Pierce, FL. 34982 Page 2 Y Comment. SUBMITTED PLANS ARE COPIES WITH DIGITAL SIGNATURE AND SEALS. + IF THE A DOCUMENT IS SUBMITTED WITH A DIGITAL SIGNATURE THE DOCUMENT MUST BE SUBMIT AS A DIGITAL SUBMISSION 1/14/2021 WITH THE ORIGINAL SIGNATURE. IF THE DOCUMENTS ARE SUBMITTED IN PAPER FORM IT MUST HAVE THE RAISED OR WET SEAL WITH THE ORIGINAL SIGNATURE. PLEASE RESUBMIT. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Response: New signed and sealed submitted / Comment: PLANS ARE INUNDATED WITH CODE SECTIONS. PLEASE REMOVE THE SECTIONS THAT DO NOT PERTAIN 1/14/2021 TO THE CONSTRUCTION OF THE PROPOSED STRUCTURE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Response: Removed Comment/ PAGE A1.01, NOTE SECTION SPECIFIES WINDOW AND DOORS BY OTHER, SEPARATE PERMIT. PLEASE 1/14/2021 REMOVE THIS SECTION AND ADD THE PRODUCT REVIEW AFFIDAVIT TO THE PLANS WITH THE NSTALLATION INSTRUCTIONS COMPLETED. OR ADD THE PRODUCT APPROVALS FOR THE WINDOWS AND DOORS. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. Response: Product review on Sht. A2.00 1/14/2021 Comment: PLEASE SUBMIT A GEOTECHNICAL EVALUATION WITH THE FOUNDATION RECOMMENDATIONS. (SOIL BORING TEST),SEE SECTION R401.4 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Response: Attached 1/14/2021 �( Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 8 SECTION R802 SUBSECTION / R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Response: Attached Comment:/ • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 1/14/2021 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. Response: Attached 1/15/2021 Comment/ • ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION / 405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE. Response: New energy caics attached Comment: • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED 1/15/2021 OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PFR SFCTION R401.8 OF THE 2017 FI ORIDA J BUILDING CODE ENERGY CONSERVATION 6TH EDITION. All windows shown pg 5 with sizes, orientation and info Comment: • LINE EIGHT ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Response: New energy calcs attached and corrected Comment: • LINE NINE ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH / EDITION. Response: New energy calcs attached and corrected Comment: J • LINE TEN ON THE ENERGY CALC'S ARE INCORRECT, SEE PLAN DETAILS. PLEASE CORRECT ENERGY 1/15/2021 CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. Response: New energy calcs attached and corrected Comment: PLEASE ADD THE CUBIC VOLUME ON THE PLANS. THE PLANS SHOULD MATCH THE CUBIC VOLUME SPECIFIED ON THE ENERGY CALC'S. THE CUBIC VOLUME NUMBER IS USED IN THE CALCULATIONS FOR d, THE BLOWER DOOR TESTING. PLEASE CHECK WITH THE COMPANY THAT CALCULATED THE CUBIC 1/15/2021 �° o' VOLUME ON THE ENERGY CALC'S AND THE DESIGN PROFESSIONAL TO COLLATE THE CUBIC VOLUME. w Q THE NUMBER SHOULD INCLUDE THE ATTIC SPACE AS THE SPRAY FOAM INSULATION IS INSTALLED TO THE ROOF DECK AND IS NOT VENTED. THIS IS CONSIDERED CONDITIONED SPACE. SEE SECTION / CHAPTER 2 DEFINITION OF CONDITION SPACE OF THE 2017 FLOR IDA ENERGY CODE. See Sht. A1.00 1/15/2021 Comment: PLEASE CLARIFY NOTE ON PAGE A1.02 FOR THE AS -BUILT ELEVATION DOCUMENTATION. WILL YOU BE SUPPLYING AS BUILT DRAWINGS? Response: Note removed Comment: PLANS CALL OUT AN ELEVATOR TO BE INSTALLED. PLEASE SUBMIT THE ELEVATORS MANUFACTURES 1/15/2021 SHOP DRAWINGS AND INSTALLATION INSTRUCTIONS. MEETING THE REQUIREMENTS OF R321 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Response: Shown Sht. A1.02 Commen A PLEASE ADD TO THE PLANS THE SQUARE FOOT CALCULATION FOR THE ENCLOSED AREAS BELOW 1/15/2021 1` FLOOD TO DETERMINE THE MINIMUM NUMBER OF FLOOD VENTS REQUIRED FOR EACH AREA ENCLOSED / BELOW FLOOD. SEE SECTION R322.2.2 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. All above Flood 1/15/2021 Comment:/ NO DETAIL SHOW ON THE PLANS FOR THE STAIRS. PLEASE ADD THE STAIR DETAILS TO THE PLANS IN COMPLIANCE WITH R311.7 AND CHAPTER 322 OF THE 2017 FLORIDA BUILDING CODE. Response: Sht. A6.00 1/15/2021 Comment- PLEASE SEE THE WALL SECTIONS ON PAGE A2.02 OF THE PLANS. I AM UNABLE TO DETERMINE 0'/ COMPLIANCE WITH R322.1.8 FOR FLOOD RESISTANT MATERIALS. Response: Sht. A6.00 Comment: ELEVATOR DETAILS SHOW WOOD CONVENTIONAL CONSTRUCTION. I AM UNABLE TO DETERMINE IF THE ELEVATORS CONSTRUCTION WILL NEED TO MEET THE REQUIREMENTS OF R322.1.8 DUE TO MISSING OR 1/15/2021 INCORRECT ELEVATION INFORMATION. IF THE LOWER PORTION OF THE ELEVATOR TOWER IS BELOW )j�" FLOOD IT WILL NEED TO MEET THE REQUIREMENTS OF R322.1.8 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Response: Note on Sht. A2.00 added and areas raised above flood level 1/15/2021 Comment3l PLEASE SEE SECTION R322.3.6 OF THE 2017 FLORIDA BUILDING CODE. PLEASE ADD TO THE PLANS THAT THE DESIGN AND METHODS OF CONSTRUCTION MEETS THE REQUIREMENT OF THIS SECTION. See Sht. A2.00 1/15/2021 Comment:"/ PLANS SHOW HOLLOW CORE DECKING. PLEASE SUBMIT THE MANUFACTURERS SHOP DRAWINGS AND PLACEMENT PLAN FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Response: Attached Plattining & Development Servlclle Building &Code ReWla6nblvsslon. ;230G 1/lrginla Auenue Fort Pierce, FL 3499.2 REVIEW COMMENTS Comment: SEE PAGE E1.01. ELECTRICAL DRAWINGS SHOW ELECTRICAL ITEMS ATTACHED TO BREAKAWAY WALLS. 1/15/2021 1PLEASE SUBMIT CORRECTED ELECTRICAL PAGE IN COMPLIANCE WITH R322.3.4 OF THE 2017 FLORIDA I" RESIDENTIAL BUILDING CODE. Response: No breakaway walls required Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 1/15/2021 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. 1/15/2021 Comment: PLEASE NOTE ALL CORRECTION WILL NEED TO BE IDENTIFIED WITH A CORRECTION REPORT FROM THE DESIGN PROFESSIONAL, AND CLOUDING THE AREAS CORRECTED FOR RESUBMISSION. ZONING REVIEW INCOMPLETE Angela Vassar 1/7/2021 Comment: PLEASE PROVIDE TWO SIGNED AND SEALED SURVEYS SHOWING THE MEASUREMENTS OF THE 'PROPOSED RESIDENCE. PER CHAPTER 11.05.01 OF THE ST LUC:IE (' MINTY LAND DEVELOPMENT CODE ALL SURVEYS SHALL COMPLETELY DEPICT THE FOLLOWING: Response: New survey attached 1.THE LOCATION OF THE PROPOSED DEVELOPMENT ACTIVITY 2.THE RELATIONSHIP OF THE ACTIVITY UNDER APPLICATION TO ALL ADJACENT PROPERTY LINES, AND AS MAY BE REQUIRED FOR THE REVIEW OF THE APPLICATION, ALL ADJACENT STRUCTURES, IMPROVEMENTS OR NATURAL FEATURES 3.A MINIMUM OF TWO (2) ELEVATIONS ALONG EACH ROADWAY ON WHICH THE PROPOSED ACTIVITY BORDERS, THE EXISTING GROUND ELEVATION AT THE APPROXIMATE CENTER OF THE PROPOSED STRUCTURE, THE EXISTING GROUND ELEVATION ALONG THE SIDE PROPERTY LINES ADJACENT TO THE PROPOSED STRUCTURE, AND THE PROPOSED FINISHED FLOOR ELEVATION OF THE STRUCTURE UNDER APPLICATION. ALL ELEVATIONS ARE TO BE BASED UPON NAVD; AND, EXCEPT FOR DETACHED SINGLE 1/7/2021 FAMILY RESIDENTIAL LOTS OR PARCELS OF LAND HAVING AN AREA OF ONE (1) ACRE OR LESS 4.THE LOCATION OF ALL NATIVE TREES OF 20 INCHES DBH AND GREATER, WITH THE SPECIFIC DIAMETER AND TYPE OF TREE CLEARLY IDENTIFIED. ALL SURVEYS SUBMITTED SHALL HAVE BEEN BE PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED LAND SURVEYOR, IN ACCORDANCE WITH THE CURRENT PROVISIONS OF CHAPTER 61 G17- 6, FAC, EXCEPT THAT APPLICATIONS FOR INTERIOR MODIFICATIONS OR CONSTRUCTION, ROOFING PERMITS NOT INVOLVING ANY STRUCTURAL ALTERATION OR ADDITIONS TO THE AREA COVERED BY THE ROOF SURFACE, OR ANY OTHER PERMIT REQUIRED ACTIVITY THAT DOES NOT RESULT IN THE EXPANSION OF ANY PORTION OF THE EXISTING STRUCTURES SHALL NOT BE REQUIRED TO SUBMIT SURVEYS. PLEASE SHOW THE COASTAL CONSTRUCTION CONTROL LINE ON THE SURVEY; PLEASE BE AWARE IF ANY OF THE STRUCTURE LIES EAST OF THE COASTAL CONSTRUCTION CONTROL LINE A DEP PERMIT WILL BE REQUIRED. Response: New survey attached 1/7/2021 Comment: PLEASE BE AWARE THESE ARE PRELIMINARY COMMENTS; THERE MAY BE MORE ZONING REVIEW COMMENTS AFTER THE SURVEY IS OBTAINED. 1/7/2021 Comment: THE PLAN REVIEWER MAY HAVE ADDITIONAL COMMENTS. Do not hesitate to call if we can be of further assistance. Best regards, Carlos Lanza, RA Burgos Lanza & Associates