Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS ' i 7/13/2021 Florida Building Code Online �n A fit o - o >3 BCIS Home I Lag In I User Registration I Hot Topics Submit Surcharge I Stats&Facts Publications Contact Us-I BCIS Site Map Links Search I Florida ai a Product Approval USER:Public User low"A r Product Approval Menu>Product or Application Search>Pgolication List>Application Detail FL# FL2569-R22 Application Type Revision � ) Code Version 2020 ����—�► t 1 l Application Status Approved Comments EVgr y, rr- � Archived s Product Manufacturer Soprema,Inc:(Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 0 - memathieu@soprema.ca RECEIVED Authorized Signature Marc-Etienne Mathieu SEP 3 0 2021 memathieu@soprema.ca St.Lucie County Technical Representative Marc-Etienne Mathieu �'�� coermittinry Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville,NON-US 00000 � (819)478-2400 Ext3327 memathieu@soprema.ca Quality Assurance Representative Jean-Francois Cote,Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report,from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert].M. Nieminen Evaluation Report Florida License, PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/21/2023 Validated By John W.Knezevich,PE `1 Validation Checklist-Hardcopy Received Certificate of Independence FL2569 R22 COI 2021 01 COI NIEMINEN pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D4798 2011 FM 4474 2011 FRSA/TRI Sixth Edition 2018 TAS 103 2020 UL1897 2015 https.1/www.floridabuilding.org/pr/pr app_ U.as.px?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYlr7amGvvoArggkU4EylLatg%3d*/*3d 112 + � r 7/13/2021 l Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code I Product Approval pp I Method h d Method 1 Option D Date Submitted 04/19/2021 Date Validated 04/19/2021 Date Pending FBC Approval 04/26/2021 Date Approved 06/08/2021 Summary of Products FL# Model,Number or Name Description 2569.1 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2569 R22 II 2021 04 19 FINAL ER SOPREMA HVHZ FL2569- Approved for use outside HVHZ:No R22.pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER Section 5 for Limits of Use. Evaluation Reports FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA HVHZ FL2569- R22.DdF Created by Independent Third Party:Yes 2569.2 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R22 II 2021 04 19 FINAL ER SOPREMA NON- Approved for use outside HVHZ:Yes HVHZ FL2569-R22.pdf Impact Resistant:N/A Verified By: Robert Nieminen,RE, PE-59166 Design Pressure:+N/A/-150 Created by Independent Third Party:Yes Other: 1.)Refer to ER Section 5 for Limits of Use. 2.) Evaluation Reports The design pressure noted herein pertains to FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA NOW undedayment systems used beneath adhesive-set the HVHZ FL2569-R22,pdf systems,Refer to ER Section 5.8.3 for details. Created by Independent Third Party:Yes Oacir Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:SSO-487-1824 The State of Florida is an AA/EEO employer.Copyrioh[2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here Product Approval Accepts: W] ® e09 M Credit Card Safe httpsJ/www.floridabuilding.org/pr/pr app_ d.aspx?param=wGEVXQwtDgsKQFEnckBl08Erx1 Ud3xYlr7amGvvoArggkU4EVILatq%3d%3d 2/2 NEW I etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION SOPREMA,Inc. Evaluation Report 3m-SOPC-2I-FBCER.A 1640 rue Haggerty FL2569-R22(HVHZ) Drummondville,Quebec J2C 5138 Canada Date of Issuance:04/19/2021 (819)478-2400 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules-and. regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality.Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes,or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named.client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMOIetc. Evaluated"may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: �" '°[•••, `cQ �`s`4�GI•,.. Lt Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen,P.E. Florida Registration No.59166,Florida DCA AfUE1983 ".?rsi;� �.`'��' on 04/19/2021.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports.are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC NNEMO I etc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Un derl ayme nt Compliance Statement: SOPREMA Roof Underlayments,as produced by SOPREMA,Inc.,have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS:2. Section Property Standard Year TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard ASTM D4601 2012 TAS 110 Material standard TAS 103 2020 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES' En_ tits Examination Reference Date ERD(TST6049) TAS 103(MS) S43530.02.14-1-R1 02/21/2014 ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014 ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014 ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014 ERD(TST6049) ASTM D1970(OH) 540540.10.14 10/31/2014 ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015 NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018 MEMO(TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO(TST6049) ASTM D4601(MS) 4q-SOP-I9-SSMBB-01.A 03/11/2019 NEMO(TST6049) ASTM D4601(OH) 4q-SOP-I9-SSMBB-01.B 03/11/2019 NEMO(TST6049) ASTM D4798/1)1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO(TST6049) ASTM D1970(MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 PRI(TSTS878) ASTM D1970(MS) 500-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015 UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019 UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/7020 UL,LLC(QUA9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: Product Material Standard Plant(s) Description 4.1 LASTOBOND TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS TAS 103 modified bitumen roof underlayment 4.2 Tri-Built S/A HT TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS Underlayment TAS 103 modified bitumen roof underlayment 4.3 LASTOBOND Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.4 RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment NEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ) SOPREMA Roof Underlayments Revision 0:04/19/2021 Page 2 of 7 i O'N'EMOJetc. 4. PRODUCT DESCRIPTION: Product Material Standard Plant(s) Description 4.5 LASTOBOND Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.6 LASTOBOND Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.7 LASTOBOND Pro HT-S ASTM D1970 Drummondville_,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underfayment 4.8 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SB5 modified bitumen roof underlayment 4.9 LASTOBOND Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS Gulfport,MS modified bitumen roof underlayment Wadsworth,OH 4.10 LASTOBOND Smooth Seal HT ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS Wadsworth,OH modified bitumen roof underlayment 4.11 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS Underla ment y Wadsworth,OH modified bitumen roof underlayment 4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS Smooth Seal HT Wadsworth,OH modified bitumen roof underlayment 4.13 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS Gulfport,MS modified bitumen roof underlayment Wadsworth,OH 4.14 TRI-BUILT Sand-R SA Shingle ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS Underlayment Gulfport,MS modified bitumen roof underlayment Wadsworth,OH 4.15 PrimeSource Grip-Rite Eave ASTM D1970 Drummondville;QC self-adhering,glass-mat reinforced,sand-surfaced,SBS &Valley Protector Gulfport,MS modified bitumen roof underlayment Wadsworth,OH 4.16 SRS TopShield ICE&WATER ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS DEFENDER Gulfport,MS modified bitumen roof underlayment Wadsworth,OH 4.17 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS Gulfport,.MS modified bitumen roof underlayment Wadsworth,OH 4.18 MODIFIED SOPRA-G ASTM D4601,Type II Gulfport,MS Fiberglass reinforced,SBS modified asphaltic base sheet Wadsworth,OH 5.1 This is a Building Code Evaluation. Neither MEMO ETC, LLC nor Robert Nfeminen, P.E.are, in any way,the Designer of Record for any project-on which this Evaluation Report;or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC Non-High Velocity Hurricane Zone jurisdictions(i.e.,outside of Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ) SOPREMA Roof Underlayments Revision 0:04/19/2021 Page 3 of 7 *NEMO I etc. 5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: .TABLE 1: ROOF COVER OPTIONS TAS 110(S10), TAS 110(S11), FBC Section: RAS 225 RAS 128,119&220 RAS 133 TAS 110(531) RAS 130 Clay and Concrete Tile Underla ment Asphalt Slate or Slate- Underlayment Mechanical Adhesive- Metal Type Shingles Wood Attach Set LASTOBOND TU HT,Tri-Built S/A HT TU Yes Underlayment Yes Yes See 5.6.1 Yes Yes Yes LASTOBOND Shield,Pro HT-N,RESISTO SA Yes No No Yes Yes Yes SMOOTH PLY 40 LASTOBOND Shield HT,Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes LASTOBOND ECO,RESISTO LB1236,TRI- BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave&Valley Protector, Yes No No No Yes Yes TopShield ICE&WATER DEFENDER, RESISTO LB1244 LASTOBOND Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment,Grip-Rite Yes No No Yes Yes Yes Smooth Seal HT 5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations. TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LASTOBOND TU HT,Tri-Built S/A HTTU Dupont"Tile Bond"Roof Tile Adhesive" FL22525 Underlayment ICP Adhesives and Sealants"Polyset°AH-160" NOA 20-1124.07 5.7 Allowable-Substrates: TABLE 2:,SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates(designed to meet wind loads for project) Type Primer Material(s) LASTOBOND Shield,LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete RESISTO SA SMOOTH PLY 40,LASTOBOND Dens Deck Prime or SECUROCK Shield HT,LASTOBOND Pro HT-S. Insulation (Optional)Elastocol Stick Zero Gypsum-Fiber Roof Board EnviroShield,LASTOBOND TU HT,Tri-BuiltS/A HTTU Underlayment,LASTOBOND ECO, self- RESISTO LB1236,TRI-BUILT Sand-R SA Shingle adhering Underlayment,Grip-Rite Eave&Valley Protector,TopShield ICE&WATER Base Sheet (Optional)Elastocol Stick Zero ASTM D226,Type II felt DEFENDER,RESISTO LB1244,LASTOBOND Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT i Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Autharization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ) SOPREMA Roof Underlayments Revision 0:04/19/2021 Page 4 of 7 NNEMOletc. TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates(designed to meet wind loads for project) Underlayment Application Type Primer Material(s) LASTOBOND TU HT,Tri-Built S/A HT TU Underlayment,RESI5TO L81236,TRI-BUILT self- Existing Existing sand-surfaced,glass-fiber Sand-R SA Shingle Underlayment,Grip-Rite adhering substrate RESISTO EXTERIOR PRIMER surfaced,mineral-surfaced or Eave&Valley Protector or TopShield ICE& film-surfaced roof underlayment* WATER DEFENDER *Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT,Tri-Built S/A HT TU Underlayment RESISTO LB1236,TRI-BUILT Sand-RSA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underloyments,contact RESISTO technical support. 5.8 Attachment Limitations: Refer to Section 6 5.9 Exposure Limitations: TABLE 3: EXPOSURE'LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure(days) LASTOBOND Eco,RESISTO LB1236,TRI-BUILT Sand-li SA Shingle Underlayment,Grip-Rite Mechanically attached 30 Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244 LASTOBOND Shield,LASTOBOND Pro HT-N,RESISTO SA SMOOTH PLY 40,LASTOBOND Shield HT,LASTOBOND Pro HT-S,EnviroShield,LASTOBOND Smooth Seal HT,Tri-Built Smooth HT Mechanically attached 90 S/A Underlayment or Grip-Rite Smooth Seal HT LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment Mechanically attached or 180 adhesive-set tile roof system 5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Double-tile stacking method,as shown below 6:12 LASTOBOND TU HT,Tri- Built S/A HT TU Underlayment Lugged NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate ofAuthorizatlon H32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-1122(HVHZ) SOPREMA Roof Underlayments Revision 0:04/19/2021 Page 5 of 7 NNEMOletc. 6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 _Approved Assemblies: 6.3.1 Deck Type 1: Wood,Non-Insulated Deck Description: Min.19/32"plywood or wood plank System Type E: Base sheet mechanically fastened to deck;underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt-or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap,mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c. in a staggered grid-pattern between the overlaps. Cap Ply: LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment,self-adhering and back-nailed max.12-inch o.c.using FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set tile roof system. Refer to Table 1A for allowable the adhesives and Table 4 for tile stagging limitations. 6.3.2 Deck Type 1: Wood,Non-Insulated Deck Description: Min.19/32"plywood or wood plank System Type E: Base sheet mechanically fastened to deck;underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type 11 felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap,mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c. in a staggered grid-pattern between the overlaps. Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, Enviro5hield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT,self- adhering. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate-type shingles, wood shakes or wood shingles. 6.3.3 Deck Type 1: Wood,Non-Insulated Deck Description: Min.19/32"plywood or wood plank System Type E: Base sheet mechanically fastened to deck;underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap,mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c. in a staggered grid-pattern between the overlaps. Cap Ply: LASTOBOND ECO,RESISTO LB1236,TRI-BUILTSand-RSA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244,self-adhering. Surfacing: FBC HVHZ Approved asphalt shingles,slate,slate-type shingles,wood shakes or wood shingles. NEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A Certiflcate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ) SOPREMA Roof Underlayments Revision 0:04/19/2021 Page 6 of 7 NNEMOjetc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: w Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 611320-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified.material standards. 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;Karen.buchmann@ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-RZ2(HVHZ) SOPREMA Roof Underlayments Revision 0:04/19/2021 Page 7 of 7 I