HomeMy WebLinkAboutPRODUCT APPROVAL
Michael Thompson, P.E. #47509/CA#30930
4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790
www.aluminumscreendesign.com
General Notes & Design Standards
(Non-Removable Pool Screen)
The following are general design standards. More stringent design standards may be noted on the plans. In the event
of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more
stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction .
Design Codes:
Florida Building Code 2020 (7th Edition)
Aluminum Design Manual 2020
ASCE 7-16
Design Loads:
Pursuant to FBC Chapters 16 & 20
Ultimate Wind: -150 MPH (FBC Table 2002.4)
Risk Category:-See attach site specific plan sheet (FBC Table 1604.5)
Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3)
Additional Load requirements:
Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using
the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically
downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind
pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any
member, not occurring simultaneously with wind load.
Design Basis:
Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor
General Requirements:
Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acce ptance of
information shown as correct and obligates himself to any expense, real or implied, arising from their use.
A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the
contractor and must be submitted to the engineer for approval.
The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify
all existing conditions prior to the start of any work. All inconsistencies shall be report ed to the designer and/or
structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans
prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the
review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall
bear no responsibility or liability for the construction of premises and accuracy of the drawings.
Foundation and Earthwork:
Applicable only when unsuitable soils are encountered.
When unsuitable soils are encountered as specified bearing strata, notify owner’s representative/engineer.
Soil bearing capacity – 2,000 psf Minimum
Provide neat excavation for footing and place concrete immediately after excavation and inspection.
Pump water from footing excavation if greater than one inch.
Compact all fill to 95% ASTM D698 density.
Unit soil weight = 105 pcf
Internal angle of friction = 30 degrees
Coeff. Of friction between footing and soil = 0.5
Michael Thompson, P.E. #47509/CA#30930
4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790
www.aluminumscreendesign.com
Structural Aluminum:
Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum
design.
All aluminum shall be 6005-T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046”
Splicing prohibited without prior approval as to location and type.
Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced.
Aluminum Protection:
Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime-mortar, concrete, or
other masonry materials, shall be protected with powder coated or ESP paint or alkali-resistant coatings, such as
heavy-bodied bituminous paint or water-white methacrylate lacquer.
Screws:
Aluminum self-tapping screws shall conform to ASME B18.6.4 specification.
Self –tapping screws shall meet the requirements of ADM J.5
Maximum fastener spacing shall not exceed (3+20t) where “t” is the member thickness in inches.
For roofing and siding connection, use minimum #12 screws f or end and side laps spaced at 12” max for side lap
and end lap fasteners shall be no more than 2” from the end of overlapping sheets.
For bottom plate and column base, secure with ¼” tapcons a minimum embedment of 1 1/8” and 2 ¼” respectively
into concrete footer.
Bolts:
Bolts and other fasteners shall be aluminum, stainless steel, hot-dip or electro-galvanized steel. Double cadmium
plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16” larger than the bolt diameter and shall
be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter.
Bolts shall meet the requirements of ADM J.3
Chair Rails, Purlins & Wind Brace:
Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor’s
specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent
dimensions and member sizes prior to ordering materials, fabrication and/or construction . Screen mesh cover areas
shall be continuously secure to each top rail, bottom rail, chair rail, upright, beam and purlin.
Wind Speed = 150 MPH
2 x 2 Chair Rail = 4’-9” 2 x 2 Purlins = 6’-6” 2 x 2 Wind Brace = 4’-3” 2 x 3 (0.125) Wind Brace = 8’-0”
2 x 3 Chair Rail = 6’-9” 2 x 3 Purlins = 6’-9” 2 x 3 Wind Brace = 6’-9” 2 x 4 Wind Brace = 8’-0”
Concrete:
Conform to ACI 318, latest edition and ACI 301
Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi
Exposed chamfer edges shall be ¾”
Reinforcing Steel:
Conform to ACI 318 and 315, Latest edition
All reinforcement steel shall be ASTM A615 Grade 60.
Smooth dowels & ties shall be ASTM A185
Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet).
Deformed bar anchors shall be ASTM A496, Grade 70
Cover: Footing 3”
Washer:
Washers shall be used under bolt heads and under nuts.
Michael Thompson, P.E. #47509/CA#30930
4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790
www.aluminumscreendesign.com
Hole Alignment:
Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips
and foreign matter between contacting surfaces shall be removed before assembly.
Cables:
Contractor shall provide a minimum 1/8” diameter stainless steel cable tie down at side and rear walls of pool screen
enclosure. Contractor shall secure cable to top of column lo cated at each corner and where there is a difference in
column height locations. In addition, cables shall be spaced to provide wall support not exceeding 227.5 ft2 with
bottom each end of cables secure to concrete slab with a minimum 3”ASTM A-36 steel clip with 2-1 ½” x ¼”
tapcons or equal.
Beams & Uprights:
In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more
stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations
prior to ordering materials, fabrication and/or construction.
150 MPH
PRIMARY ROOF MEMBERS-POOL CAGE ENCLOSURES
SIZE
Roof Span
*Maximum Beam
Spacing = 6'-0"
Roof Span
*Maximum Beam
Spacing = 6'-8"
Roof Span
*Maximum Beam
Spacing = 7'-2"
2 X 4 14'-3" 13'-3" 10'-6"
2 X 5 19'-0" 18'-0" 15'-6"
2 X 6 22'-3" 20'-0" 18'-9"
2 X 7 24'-0" 21'-8" 21'-6"
2 X 8 28'-0" 26'-9" 26'-6"
2 X 9 30'-0" 28'-5" 28'-0"
2 X 10 33'-6" 31'-11" 31'-6"
Knee Bracing:
Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and
length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more
than 6” above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15’ max; 2 x 3 for 30’
max; 2 x4 for beam span greater than 30’.
Purlin:
Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall
not exceed 7’-2”.
Header Beam:
Contractor is required to install a minimum 2 x 7 header beam supported with 3 x 3 column space at 10 feet (max)
with a 2’ x 2’ x 1’-6” concrete footer with 3#5 each way when screen enclosed is required to be attached super
gutter at the interface of the insulated roof panel. Contractor is required to install insulated roof covering pursuant t o
the Florida product approval specification (45 psf).
Intermediate Girts:
Contractor is required to install intermediate chair rails/girts spaced at mid-span between the chair rails and top rail
or 6'-0" max on center when column height exceeds 11 feet. Contractor is also required to install one additional
intermediate chair rail/girt to be located 3 feet below the top rail when column height exceeds 14 feet.
Edge Distance:
Contractor is required to install uprights to provide a 2” minimum clearance from edge of slab and/or footer.
Upright -Pool Cage Enclosures
Upright
150
MPH
SIZE Height
2 X 4 10'-3"
2 X 5 12'-3"
2 X 6 13'-3"
2 X 7 14’-6”
2 X 8 15’-6”
2 X 9 16'-6"
ALUMINUM SCREEN DESIGN
MICHAEL THOMPSON
4401 VINELAND ROAD
SUITE A6
ORLANDO, FL 32811
P.E. # 47509
CA#30930
ALUMINUMSCREENDESIGN.COM
ALUMINUMSCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
DESIGN STATEMENT
HINGE LOCATIONS
30" to 36"
2X2 POST .046 OR GREATER
2 HINGE DOOR
EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O.C.
SCREEN DOOR FULL Z OR
DOOR JAM STANDARD DETAIL
1X2 IS ATTACHED TO BLOCK STRUCTURE
WITH 2-1/4" X 1/4" TAPCONS 6" FROM
ENDS 24" O.C.
1X2 IS ATTACHED TO 3X3 POST
WITH #10 2" 6" FROM ENDS 24" O.C.
1X2 IS ATTACHED TO CONCRETE
WITH 2-1/4" X 1/4" TAPCONS
(5" X 1/4" IF THRU PAVERS)
6" FROM ENDS 24" O.C.
CHAIR RAIL IS ATTACHED TO UPRIGHTS
WITH EITHER:
BLIND SCREWED WITH (3) #10 3" OR,
CAPRI CLIPPED WITH (4) #10 1" PER CLIP OR
BLIND CLIPPED WITH (4) #10 1" PER CLIP
UPRIGHTS ARE ATTACHED WITH:
BLIND SCREWED WITH (3) #10 3",
CAPRI CLIPPED WITH (4) #10 1" PER CLIP
BLIND CLIPPED WITH (4) #10 1" PER CLIP
UPRIGHTS ARE ATTACHED WITH:
BLIND SCREWED WITH (3) #10 2" OR,
CAPRI CLIPPED WITH (4) #10 1" PER CLIP &
BLIND CLIPPED WITH (4) #10 1" PER CLIP
3X3 POSTS ARE ATTACHED
TO 2X7 BEAM 2 3/8" X 3 1/2"
CARRIAGE BOLTS TYP.
3X3 POST IS ATTACHED TO
BRACKET WITH (2) 3/8" X 3
1/2" CARRIAGE BOLTS
BRACKET FROM 3X3 IS ATTACHED
TO CONCRETE WITH 2 1/4" X 2"
TAPCONS TYP.
EXTRUDED GUTTER IS ATTACHED TO
SUPPORT BEAM WITH #10 1" 6"
FROM ENDS 24" O.C.
ROOF IS ATTACHED TO FRONT WALL
WITH (4) #10 4" PER PANEL
2X2 CHAIR RAIL
3" INSULATED ROOF IS ATTACHED TO
ALUMINUM STRUCTURE WITH #10 4"
6" FROM ENDS 24" O.C.
2X2 TOP PLATE
METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2020 (7TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI-OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
3" C CHANNEL IS ATTACHED TO FASCIA WITH #10 2" 6" FROM ENDS 24" O.C.
& TO 3" INSULATED ROOF WITH (6) #10 1" PER SIDE
EXTRUDED FASCIA IS ATTACHED TO
3" INSULATED ROOF WITH #10 1" 6"
FROM ENDS 24" O.C.
2X5 SIDE WALL UPRIGHTS
2" X 2" X 1/8" ANGLE IS ATTACHED TO
UPRIGHT W/ (2) #10 1" & INTO CONCRETE
W/ 2-1/4" X 1/4" TAPCON
ALUMINUM SCREEN DESIGN
MICHAEL THOMPSON
4401 VINELAND ROAD
SUITE A6
ORLANDO, FL 32811
P.E. # 47509
CA#30930
ALUMINUMSCREENDESIGN.COM
ALUMINUMSCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
DESIGN STATEMENT
1" GUTTER STRAP IS ATTACHED
TO GUTTER WITH #10 1" & INTO
FASCIA WITH #10 2" PER STRAP
24" O.C. MAX 4" FROM EACH UPRIGHT
SMB
BEAM IS ATTACHED TO GUTTER W/
2X2X1/8" ANGLE & (4) #10 1" PER SIDE
PURLINS ATTACHED TO BEAM W/
(3) #10 2" SMS, PLACE WASHER
UNDER SCREW IN GUSSET CORNER
(10) #10 SMS 1-1/4 O.C.
3/16" GUSSET
NOTES
1. GUSSET DIMENSIONS ARE MINIMUM
8" ON BOTH SIDE OF BEAM, MAY BE
INTERNAL OR EXTERNAL
2. AS BEAM SIZE CHANGES ADD OR
SUBTRACT TO MAINTAIN A 1-1/4" O.C.
SCREW SPACING W/ (10) SCREWS
3. GUSSET LENGTH REMAINS CONSTANT,
WIDTHS CHANGE TO MATCH BEAM SIZE
METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2020 (7TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI-OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
2X2 IS ATTACHED TO STRUCTURE W/
4" X 1/4" TAPCONS (#10 4" IF TO WOOD
STRUCTURE) 6" FROM ENDS 24" O.C.
2X2 ANGLE IS ATTACHED TO BEAM
WITH (2) #10 1" & INTO BLOCK WITH
2-1/4" X 1/4" TAPCON
(10) #10 SMS 1-1/4 O.C.
3/16" GUSSET
BEAM TO FASCIA
BEAM TO WALL
SEE GENERAL NOTES
& DESIGN STANDARD
FOR ADDITIONAL
INFORMATION (TYP.)3' MAX RISE
ALUMINUM SCREEN DESIGN
MICHAEL THOMPSON
4401 VINELAND ROAD
SUITE A6
ORLANDO, FL 32811
P.E. # 47509
CA#30930
ALUMINUMSCREENDESIGN.COM
ALUMINUMSCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
DESIGN STATEMENTHINGE LOCATIONS30" TO 36"
2X3 POST OR DOOR JAMB
2 HINGE DOOR
EACH DOOR IS SCREWED INTO UPRIGHTS
WITH #10 1" SCREWES 24" O.C.
DOOR FULL Z OR
DOOR JAM
STANDARD
SMB BEAM IS NOTCHED
OVER UPRIGHT
2X2 INTERNALLY SCREWED
THRU BEAM W/ (3) #10 2"
1X2 FASTENED TO 2X2 W/ #10 2"
6" FROM UPRIGHTS 24" O.C.
(6) #10 1" INTO GUSSET
PLATE PER SIDE TYP.
C-CHANNEL ATTACHES UPRIGHT TO
TOP PLATES WITH (4) #10 1" INTO
UPRIGHT & (3) #10 1" INTO TOP PLATES
UPRIGHT ATTACHES TO PURLIN W/
1X2 ANGLE & (4) #10 1" PER SIDE
2X2 EDGE BEAM
2X2 ROOF PURLIN
2X2 TOP PLATE IS ATTACHED TO
2X2 PURLIN WITH (2) #10 4" THRU
BEAM INTO PURLIN EMBOSS
1X2 FASTENED TO 2X2 W/ #10 2"
6" FROM UPRIGHTS 24" O.C.
FRONT WALL TO BEAM
SIDE WALL CONNECTION DETAILS WHEN
PURLIN DOESNT HIT POST
SIDE WALL CONNECTION DETAILS WHEN
PURLIN DOESNT HIT POST
PURLIN
2X2 TOP PLATE IS ATTACHED TO
2X2 PURLIN WITH (2) #10 4" THRU
BEAM INTO PURLIN EMBOSS
1X2 FASTENED TO 2X2 W/ #10 2"
6" FROM UPRIGHTS 24" O.C.
SLOPED PURLIN CONNECTION DETAIL
1-1/2" X 2" X 1-1/2" X 0.062"
RECEIVER CHANNEL
REMOVE BACK TO FIT OVER
PURLIN PROVIDE (4) #10 X 3/4"
INTO PURLIN & UPRIGHT
2-1/8" X 1-1/2" C-CHANNEL
METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2020 (7TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI-OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
ALUMINUM SCREEN DESIGN
MICHAEL THOMPSON
4401 VINELAND ROAD
SUITE A6
ORLANDO, FL 32811
P.E. # 47509
CA#30930
ALUMINUMSCREENDESIGN.COM
ALUMINUMSCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
DESIGN STATEMENT
1/8" STAINLESS
STEEL CABLE
12' TO 14'
ANCHORED INTO CONCRETE 3/4" FROM TOP AND BOTTOM CONCRETE
3"A.S.T.M. A-36 STEEL CLIP WITH 2 1-1/2"X1/4" TAPCONS
((2) #10 2" IF TO WOOD DECK)
CABLE DETAIL7" X 7"5/16" EYE BOLT WELDED
CLOSED WITH DOUBLE NUTS
COMPRESSION SLEEVE
COMPRESSION
SLEEVE
45 DEGREE
MIMIMUM
SIDE VIEW
COMPRESSION SLEEVE
3"A.S.T.M. A-36 STEEL CLIP
WITH 2 2 1/4"X1/4 TAPCONS
EACH CABLE WILL
SUPPORT 227.5 SQUARE
FEET OF WALL AREA
1/8" THICK ANGLE BRACKET
ATTACHED TO UPRITE AND
GIRT WITH (6) #10 1"
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE HOMEOWNER THAT THE CABLES AND CABLE
ATTACHMENT MUST BE INSPECTED BY THE HOMEOWNER AT LEAST TWICE A YEAR TO ELIMINATE ANY DEFICIENCIES ASSOCIATED
WITH TENSION SLACK AND/OR CORROSION AND IF NECESSARY TO MAKE CORRECTIVE REPAIRS TO MAINTAIN THE CABLE FULL TENSION
(NO SLACK) DESIGNED FOR STRUCTURAL LATERAL STABILITY
METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2020 (7TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI-OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
2X2 K BRACE IS ATTACHED TO
ALUMINUM STRUCTURE WITH
2X2" C CHANNEL & (6) #10 1"
OR BLIND SCREWED WITH
(3) #10 2" PER END
K BRACING DETAIL
GIRT
2X2 K-BRACE TYP.4" X 8" X 1/8" PLATE
WITH #14 X 1" INTO
MEMBER AS
INDICATED
OR
SEE GENERAL NOTES
& DESIGN STANDARD
FOR ADDITIONAL
INFORMATION (TYP.)
MIN 4" SLAB 2500 PSI
CONCRETE W/ FIBERMESH
1X2 INTERNALLY SCREWED
THRU 2X2X1/8" ANGLE TO
UPRIGHT W/ (2) #10 X
1-1/2" FASTEN 1X2 TO
CONCRETE W/ 3" X 1/4"
(5" X 1/4" TAPCONS IF THRU PAVERS)
(#10 2" IF TO WOOD DECK)
SCREW CONCRETE ANCHOR
6" FROM UPRIGHT 24" O.C.
UPRIGHT SHALL BE STITCHED
W/ #10 X 1" SELF TAPPING
SCREWS 12" O.C. TYP.
SELF MATING UPRIGHT DETAILS
(2) #10 1" PER SIDE
CHAIR RAIL & KICK PLATE DETAIL
2X2 CHAIR RAILS & GIRTS ARE
ATTACHED W/ INTERNAL CLIPS
W/ (4) #10 1", CAPRI CLIPPED,
W/ RECIEVING CHANNEL & (6) #10 1"
W/ (8) #10 1", OR BLIND
SCREWED W/ (3) #10 2"
KICK PLATE IS ATTACHED TO
STRUCTURE WITH #10 1" 6"
FROM ENDS 18" O.C.
(OPTIONAL)
ALUMINUM SCREEN DESIGN
MICHAEL THOMPSON
4401 VINELAND ROAD
SUITE A6
ORLANDO, FL 32811
P.E. # 47509
CA#309301X2 SIDE WALL IS ATTACHED TO FRONTWALL WITH #10 2" 6" FROM ENDS 24" O.C.1X2 IS ATTACHED TO HOUSE WITH2/1/4" X 1/4" TAPCONS OR #10 4" 6"FROM ENDS 24" O.C.SIDE WALL DETAIL
1X2 BOTTOM PLATE IS ATTACHED TO
UPRIGHTS WITH CAPRI CLIP WITH (4)
#10 1" OR BLIND SCREWED WITH (2)
#10 2" PER SIDE
1X2 TOP PLATE IS ATTACHED TO 2X2
WALL BEAM WITH #10 2" 6" FROM
ENDS 24" O.C.
1X2 BOTTOM PLATE IS ATTACHED
TO CONCRETE WITH 2-1/4" X 1/4" TAPCONS
(5" X 1/4" IF THRU PAVERS TO FOOTER)
(#10 2" IF TO WOOD DECK)
6" FROM ENDS 24" O.C.
1X2
1X21X2SIDE WALL UPRIGHT
ALUMINUMSCREENDESIGN.COM
ALUMINUMSCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
DESIGN STATEMENT
METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2020 (7TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI-OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
SEE GENERAL NOTES
& DESIGN STANDARD
FOR ADDITIONAL
INFORMATION (TYP.)
BLIND CLIP & CAPRI CLIP DETAILS
RECIEVING CHANNEL CLIP DETAILS