HomeMy WebLinkAboutEnergy CodeFORM R405-2020. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MARS RESIDENCE Builder Name: SUNRISE CITY CONSTRUCTION, INC Street: 1702 JUANITA AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1360.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1360.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1487.0 .sgft.) _ Insulation Area a. Under Attic (Vented) R=30.0 1487.00 ft2 6. Conditioned floor area above grade (ft2) 1487 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(197.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: UTILITY RM R ft2 6 140 a. U-Factor: Sgl, U=0.65 197.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 5.706 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1487.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1487.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.132 Total Proposed Modified Loads: 43.88 PASS Total Baseline Loads: 50.68 I hereby certify that the plans and specifications covered by Review of the plans and O�fTEr�� this calculation are in compliance with the Florida Energy specifications covered by this ' '` Code. calculation indicates compliance g vi,''�� �•�`� •r with the Florida Energy Code. F+ tui r'"� ,•• ��`�`,�O' PREPA D Y: Before construction is completed c s`' DATE: 2021 this building will be inspected for compliance with Section 553.908 I hereby certify that this building as g compliance designed, is in the Florida Energy Code. Florida Statutes. Ca171NE'T��y-. with OWNER/AGENT• BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). , C 1. 0 8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: MARS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1487 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: SUNRISE CITY CONSTRUCT Rotate Angle: 0 Street: 1702 JUANITA AVENU Permit Office: ST LUCIE COUNTY Cross Ventilation: No. County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location . TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1487 11896 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FAMILIY RM 216 1728 No 0 1 Yes Yes Yes 2 UTILITY RM 84 672 No 0 1 Yes Yes Yes 3 BEDROOM 3 144 1152 No 0 1 1 Yes Yes Yes 4 CLST 3 20 160 No 0 1 No Yes Yes 5 BATH 2 45 360 No 0 1 No Yes Yes 6 HALLWAY 69 552 No 0 1 No Yes Yes 7 BEDROOM 2 106 848 No 0 1 1 Yes Yes Yes 8 CLST 2 14 112 No 0 1 Yes Yes Yes 9 KITCHEN 156 1248 Yes 0 1 Yes Yes Yes 10 LIVING RM 273 2184 No 0 1 Yes Yes Yes 11 MASTER BEDROO 250 2000 No 0 1 1 Yes Yes Yes 12 M W IC 60 480 No 0 1 Yes Yes Yes 13 M BATH 50 400 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation FAMILIY RM 30 ft 216 ft2 ___ 1 0 0 2 Slab -On -Grade Edge Insulation UTILITY RM 19 ft 84 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 3 9 ft 144 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation CLST 3 1 ft 20 ft2 ____ 1 0 0 8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation BATH 2 1 ft 45 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation HALLWAY 1 ft 69 ft2 __e 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 10 ft 106 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation CLST 2 2 ft 14 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation KITCHEN 12 ft 156 ft2 _-__ 1 0 0 10SIab-On-Grade Edge Insulation LIVING RM 34 ft 273 ft2 1 0 0 11SIab-On-Grade Edge Insulation MASTER BEDRO 33 ft 250 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulation M WIC 16 ft 60 ft2 1 0 0 13SIab-On-Grade Edge Insulation M BATH 5 ft 50 ft2 ____ 1 0 0 ROOF v Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1611 ft2 0 ft2 Medium N 0.3 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1487 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) FAMILIY RM 30 Blown 216 ft2 0.1 Wood 2. Under Attic (Vented) UTILITY RM 30 Blown 84 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 3 30 Blown 144 ft2 0.1 Wood 4 Under Attic (Vented) CLST 3 30 Blown 20 ft2 0.1 Wood 5 Under Attic (Vented) BATH 2 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) HALLWAY 30 Blown 69 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 106 ft2 0.1 Wood 8 Under Attic (Vented) CLST 2 30 Blown 14 ft2 0.1 Wood 9 Under Attic (Vented) KITCHEN 30 Blown 156ft2 0.1 Wood 10 Under Attic (Vented) LIVING RM 30 Blown 273 ft2 0.1 Wood 11 Under Attic (Vented) MASTER BEDRO 30 Blown 250 ft2 0.1 Wood 12 Under Attic (Vented) M W IC 30 Blown 60 ft2 0.1 Wood 13 Under Attic (Vented) M BATH 30 Blown 50 ft2 0.1 Wood 8/10/2021 9:32 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent CavitR_Vay Width Height Sheathing Framing Solar Below Space Et 1 N Exterior Concrete Block - Int InsuFAMILIY RM 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block - Int InsuFAMILIY RM 4.1 18 0 8 0 144.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Int InsulUTILITY RM 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Int InsuIUTILITY RM 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 5 N Exterior Concrete Block - Int InsuBEDROOM 3 4.1 9 0 8 0 72.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0 7 E Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 8 S Exterior Concrete Block - Int Insul KITCHEN 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 9 E Exterior Concrete Block - Int Insul LIVING RM 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 _ 10 S Exterior Concrete Block - Int Insul LIVING RM 4.1 21 0 8 0 168.0 ft2 0 0 0.3 0 11 N Exterior Concrete Block - Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 12 E Exterior Concrete Block - Int InsuMASTER BE 4.1 15 0 8 0 120.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block - Int InsuMASTER BE 4.1 4 0 8 0 32.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block- Int Insul M W IC 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0 15 W Exterior Concrete Block- Int Insul M W IC 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0 16 W Exterior Concrete Block - Int Insul M BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated FAMILIY RM None .23 2 8 6 8 17.8 ft2 2 W Insulated MASTER BE None .23 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 Y 40.0 f12 12 ft 0 in 1 ft 4 in None None 2 N 5 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 12 ft 0 in 1 ft 4 in None None 3 E 6 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None " 4 S 8 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 9 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 S 10 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 7 S 10 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 8 ft 0 in 1 ft 4 in None None 8 S 10 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 8 ft 0 in 1 ft 4 in None None 9 N 11 Metal Low-E Single Yes 0.65 0.25 Y 30.0 f12 2 ft 0 in 1 ft 4 in None None 8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 991.3 54.39 102.11 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/. Split Single SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY RM 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ftx DUCTS — Supply -- # Location R-Value Area -- Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 140 f? Attic 14 ftz Default Leakage. UTILITY R (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N CoolingJan Feb [ Mar HeatinJan Feb [X; Mar VentingJan Feb [X] Mar Ceiling Fans: Apr j Ma Jun X] Jul Au Se [ ] f Apr . f ] May 4 Jun f ] Jul 4 Au4 Sep, [ ] [X) Apr [ ] May [ Jun [)Jul [ Aug [ Se [X] Oct Nov Oct �X} Nov Oct [X] Nov Dec f X} Dec [ ]Dec 8/10/2021 9:32 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3, 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 . 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ff2 0 ft 0.3 FAMILIY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC Default(8 Ibs/s .ft. ft2 ft 0.3 M BATH 8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MARS RESIDENCE Builder Name: SUNRISE CITY CONSTRUCTION, INC Street: 1702 JUANITA AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind DiDing and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 8/10/2021 9:33 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM. R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. 1702 JUANITA AVENUE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. W aA Type and Insulation. Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1360.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms. 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1487.00 ft2 6. Conditioned floor area (ft2) 1487 b. N/A R= ft2 7. Windows** Description Area _ R 2 a. U-Factor: Sgl, U=0.65 197.00 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: UTILITY RM 6 140 SHGC: SHGC=0.25 b. -U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 30.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 5.706 ft. Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1487.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/10/2021 9:33 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1