HomeMy WebLinkAboutEnergy CodeFORM R405-2020.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MARS RESIDENCE
Builder Name: SUNRISE CITY CONSTRUCTION, INC
Street: 1702 JUANITA AVENUE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1360.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1360.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1487.0 .sgft.) _
Insulation Area
a. Under Attic (Vented)
R=30.0 1487.00 ft2
6. Conditioned floor area above grade (ft2) 1487
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(197.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: UTILITY RM
R ft2
6 140
a. U-Factor: Sgl, U=0.65 197.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 5.706 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1487.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 1487.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.132 Total Proposed Modified Loads: 43.88
PASS
Total Baseline Loads: 50.68
I hereby certify that the plans and specifications covered by
Review of the plans and
O�fTEr��
this calculation are in compliance with the Florida Energy
specifications covered by this
' '`
Code.
calculation indicates compliance g vi,''�� �•�`� •r
with the Florida Energy Code.
F+ tui r'"� ,•• ��`�`,�O'
PREPA D Y:
Before construction is completed
c s`'
DATE: 2021
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building as g compliance designed, is in
the Florida Energy Code.
Florida Statutes.
Ca171NE'T��y-.
with
OWNER/AGENT•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
,
C 1. 0
8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: MARS RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1487
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: SUNRISE CITY CONSTRUCT
Rotate Angle: 0
Street:
1702 JUANITA AVENU
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No.
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type: Detached
FL,
New/E)asting: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location . TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1487
11896
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 FAMILIY RM 216
1728 No
0
1
Yes
Yes
Yes
2 UTILITY RM 84
672 No
0
1
Yes
Yes
Yes
3 BEDROOM 3 144
1152 No
0
1
1
Yes
Yes
Yes
4 CLST 3 20
160 No
0
1
No
Yes
Yes
5 BATH 2 45
360 No
0
1
No
Yes
Yes
6 HALLWAY 69
552 No
0
1
No
Yes
Yes
7 BEDROOM 2 106
848 No
0
1
1
Yes
Yes
Yes
8 CLST 2 14
112 No
0
1
Yes
Yes
Yes
9 KITCHEN 156
1248 Yes
0
1
Yes
Yes
Yes
10 LIVING RM 273
2184 No
0
1
Yes
Yes
Yes
11 MASTER BEDROO 250
2000 No
0
1
1
Yes
Yes
Yes
12 M W IC 60
480 No
0
1
Yes
Yes
Yes
13 M BATH 50
400 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation FAMILIY RM 30 ft
216 ft2
___
1 0
0
2 Slab -On -Grade Edge Insulation UTILITY RM 19 ft
84 ft2
___
1 0
0
3 Slab -On -Grade Edge Insulation BEDROOM 3 9 ft
144 ft2
____
1 0
0
4 Slab -On -Grade Edge Insulation CLST 3 1 ft
20 ft2
____
1 0
0
8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulation
BATH 2 1 ft
45 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
HALLWAY 1 ft
69 ft2
__e
1
0
0
7 Slab -On -Grade Edge Insulation
BEDROOM 2 10 ft
106 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
CLST 2 2 ft
14 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
KITCHEN 12 ft
156 ft2
_-__
1
0
0
10SIab-On-Grade Edge Insulation
LIVING RM 34 ft
273 ft2
1
0
0
11SIab-On-Grade Edge Insulation
MASTER BEDRO 33 ft
250 ft2
__
1
0
0
12SIab-On-Grade Edge Insulation
M WIC 16 ft
60 ft2
1
0
0
13SIab-On-Grade Edge Insulation
M BATH 5 ft
50 ft2
____
1
0
0
ROOF
v
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 1611 ft2
0 ft2
Medium
N
0.3
No 0.9
No 0
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1487 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
FAMILIY RM
30
Blown
216 ft2
0.1
Wood
2. Under Attic (Vented)
UTILITY RM
30
Blown
84 ft2
0.1
Wood
3 Under Attic (Vented)
BEDROOM 3
30
Blown
144 ft2
0.1
Wood
4 Under Attic (Vented)
CLST 3
30
Blown
20 ft2
0.1
Wood
5 Under Attic (Vented)
BATH 2
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented)
HALLWAY
30
Blown
69 ft2
0.1
Wood
7 Under Attic (Vented)
BEDROOM 2
30
Blown
106 ft2
0.1
Wood
8 Under Attic (Vented)
CLST 2
30
Blown
14 ft2
0.1
Wood
9 Under Attic (Vented)
KITCHEN
30
Blown
156ft2
0.1
Wood
10 Under Attic (Vented)
LIVING RM
30
Blown
273 ft2
0.1
Wood
11 Under Attic (Vented)
MASTER BEDRO
30
Blown
250 ft2
0.1
Wood
12 Under Attic (Vented)
M W IC
30
Blown
60 ft2
0.1
Wood
13 Under Attic (Vented)
M BATH
30
Blown
50 ft2
0.1
Wood
8/10/2021 9:32 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
CavitR_Vay
Width
Height
Sheathing Framing
Solar
Below
Space
Et
1
N
Exterior
Concrete Block - Int InsuFAMILIY RM
4.1
12
0
8 0
96.0 ft2
0
0
0.3
0
2
W
Exterior
Concrete Block - Int InsuFAMILIY RM
4.1
18
0
8 0
144.0 ft2
0
0
0.3
0
3
S
Exterior
Concrete Block - Int InsulUTILITY RM
4.1
12
0
8 0
96.0 ft2
0
0
0.3
0
4
W
Exterior
Concrete Block - Int InsuIUTILITY RM
4.1
7
0
8 0
56.0 ft2
0
0
0.3
0
5
N
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
9
0
8 0
72.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
10
0
8 0
80.0 ft2
0
0
0.3
0
7
E
Exterior
Concrete Block - Int Insul CLST 2
4.1
2
0
8 0
16.0 ft2
0
0
0.3
0
8
S
Exterior
Concrete Block - Int Insul KITCHEN
4.1
12
0
8 0
96.0 ft2
0
0
0.3
0
9
E
Exterior
Concrete Block - Int Insul LIVING RM
4.1
13
0
8 0
104.0 ft2
0
0
0.3
0
_ 10
S
Exterior
Concrete Block - Int Insul LIVING RM
4.1
21
0
8 0
168.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block - Int InsuMASTER BE
4.1
14
0
8 0
112.0 ft2
0
0
0.3
0
12
E
Exterior
Concrete Block - Int InsuMASTER BE
4.1
15
0
8 0
120.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block - Int InsuMASTER BE
4.1
4
0
8 0
32.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block- Int Insul M W IC
4.1
10
0
8 0
80.0 ft2
0
0
0.3
0
15
W
Exterior
Concrete Block- Int Insul M W IC
4.1
6
0
8 0
48.0 ft2
0
0
0.3
0
16
W
Exterior
Concrete Block - Int Insul M BATH
4.1
5
0
8 0
40.0 ft2
0
0
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated FAMILIY RM
None
.23
2
8
6 8
17.8 ft2
2
W
Insulated MASTER BE
None
.23
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.65
0.25
Y
40.0 f12
12 ft 0 in
1 ft 4 in
None
None
2
N 5
Metal Low-E Single Yes
0.65
0.25
Y
9.0 ft2
12 ft 0 in
1 ft 4 in
None
None
3
E 6
Metal Low-E Single Yes
0.65
0.25
Y
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None "
4
S 8
Metal Low-E Single Yes
0.65
0.25
Y
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
E 9
Metal Low-E Single Yes
0.65
0.25
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
S 10
Metal Low-E Single Yes
0.65
0.25
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
S 10
Metal Low-E Single Yes
0.65
0.25
Y
20.0 ft2
8 ft 0 in
1 ft 4 in
None
None
8
S 10
Metal Low-E Single Yes
0.65
0.25
Y
20.0 ft2
8 ft 0 in
1 ft 4 in
None
None
9
N 11
Metal Low-E Single Yes
0.65
0.25
Y
30.0 f12
2 ft 0 in
1 ft 4 in
None
None
8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000254 991.3 54.39 102.11 .0902
5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None COP:1 27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/.
Split Single SEER: 16 30 kBtu/hr 900 cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location EF Cap Use SetPnt
Conservation
1 Electric None
UTILITY RM 0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftx
DUCTS
— Supply --
# Location R-Value Area
-- Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 140 f?
Attic 14 ftz Default Leakage. UTILITY R (Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
CoolingJan Feb [ Mar
HeatinJan Feb [X; Mar
VentingJan Feb [X] Mar
Ceiling Fans:
Apr j Ma Jun X] Jul Au Se [ ]
f Apr . f ] May 4 Jun f ] Jul 4 Au4 Sep, [ ]
[X) Apr [ ] May [ Jun [)Jul [ Aug [ Se [X]
Oct Nov
Oct �X} Nov
Oct [X] Nov
Dec
f X} Dec
[ ]Dec
8/10/2021 9:32 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3,
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
.
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ff2
0 ft
0.3
FAMILIY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
UTILITY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft2
ft
0.3
LIVING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC
Default(8 Ibs/s .ft.
ft2
ft
0.3
M BATH
8/10/2021 9:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MARS RESIDENCE Builder Name: SUNRISE CITY CONSTRUCTION, INC
Street: 1702 JUANITA AVENUE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind DiDing and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/10/2021 9:33 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM. R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 87
The lower the EnergyPerformance Index, the more efficient the home.
1702 JUANITA AVENUE, FORT PIERCE, FL,
1. New construction or existing
New (From Plans)
10. W aA Type and Insulation.
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1360.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms.
3
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0
1487.00 ft2
6. Conditioned floor area (ft2)
1487
b. N/A
R=
ft2
7. Windows** Description
Area
_
R
2
a. U-Factor: Sgl, U=0.65
197.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: UTILITY RM
6 140
SHGC: SHGC=0.25
b. -U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
30.0
SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth:
5.706 ft.
Area Weighted Average SHGC:
0.250
8. Skylights Description
Area
15. Hot water systems
Cap:
50 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.98
SHGC(AVG): N/A
b. Conservation features
9. floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1487.00 ft2
Credits (Performance method)
None
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/10/2021 9:33 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1