FL #
FL10674-R16
Application Type
Revision
Code Version
2020
Application Status
Pending FBC Approval
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative-
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
X
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Roofing
Asphalt Shingles
F0REC��Elv D4 2021
ST. Lucie County., Permitting
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
ED Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL10674 R16 COI 2020 01 COI NIEMINEN.pdf
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
Year
2015
2016
2010
2019
https://wvm.floridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAIpOjcKTwWbw%3d%3d 1/2
1/1/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 12/11/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Summary of Products
FL.#
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, laminated, starter and hip &ridge shingles
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.12df
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: AccessibiliN Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
WE PER PER ER 0
"sccuriltYMIFTRICS'
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAIpOjcKTwWbw%3d%3d 2/2
MEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
Owens Corning Evaluation Report 037940.02.12-1111
One Owens Corning Parkway FL10674-R16
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7t' Edition (2020) Florida Building Code sections noted herein.
DEscRIPTION 'Owens.Cormng Asphalt Roof Shlrigles
". ..
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. .
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared b :
p Y
�1�1S11LIf11„+� -�
.�.......... •.
i
Robert J.M.Nieminen P.E.
'•T;F,',�::sT.s;�;" The facsimile seal appearing was authorized by Robert
'.'
'
°S� Nieminen, P.E. on 12/11/2020. This does not serve as an
"rr�„�;�;,,:1.
Florida Registration No. 59166, Florida DCAANE1983
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
9)2018 NEMO ETC, LLC
MEMO l etc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 7th Edition '(2020) Florida Building Code through
testing.in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
r Section; r _
Pro e
, , =Standard
Year
1507.2.4, R905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905.2.4
Material standard
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, 11905.2.6.1
Wind Resistance
ASTM D7158
2019
? bitity,_-
Examination
Reference
Date .
Owens Corning
Declaration
Equivalency Declaration,
08/06/2019
PRI(TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-132453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
.UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
PRI (QUA9110) .
Quality Control
Service Confirmation
04/05/2020
PRI (QUA9110)
Quality Control
Florida BCIS
Current
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization #32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 2 of 10
ONEMoletc.
• TABLE;1: ASPHALT SHINGLE,COMPONENTS
�_ b
Type
Product
Plent(s)
Material
Standard -
Description
Berkshire Hip and Ridge
MN
Shingles with Sealant
DuraRidge® Hip and Ridge
MN
Hip and ,
fiberglass reinforced, hip and ridge
Ridge: „
Shingles with Sealant
ASTM D3462
asphalt roof shingles
ProEdgel
GA, CA, OH, OR
Shingles
WeatherGuard° HP Hip and
Ridge Shingles
TN
5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation- of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
5.5.1
TABLE 2A U11(NDkCLASSIFICATIONS, ASPHALT SHINGLES _,
Product—
FBC Table 1507.2.7:1 or R905.2.6.1 .
Supreme* -
ASTM D3161(F) & ASTM-,D7158(H)
Berkshire"
Duration' Premium
Duration® Premium COOL
TruDefinition` Duration*
TruDefinition® Duration' Designer Color Collection
Oakridge°
TruDefinition° Oakridge®
WeatherGuard° HP
Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for,data specific to each shingle.
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization#32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 3 of 10
ONEMO
Type _ v Product FBC Table 1503,2.7.1orR905 2.6 1
Starter Strip Shingle
Starter Strips. Starter Strip Plus ASTM D3161, Class F
SRS TopShield Starter
1 Berkshire* Hip and Ridge Shingles with Sealant
Hip&& Ridge DuraRidge® Hip and Ridge Shingles with Sealant
Shingles .` ProEdge® ASTM 03161, Class F
WeatherGuard' HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6 INSTALLATION 17
R•. 3 s *+
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 `.ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Felt underlayment
—Deck
Self -adhered
WeathetLock'
`. underlayment
Drip
Drip edge
edge
Nails located
2 4 from eave
Install first
Self-sealing adhesive
Starter Strip
positioned along eave
shingle with
W removed
Starter Strip shingle overhangs eaves and rakes W-s/T
ter'
Drip edge
Nab located
2'-3" from eave
Serrtearing adhesive
-
positioned along eave
Starter Stdp plus overhangs eavas and rakes 114 -314'
Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 4 of 10
ONEMOjetc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
�— Deck
Drip edge
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire* shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Normal
Wind Areas
Area pare vientos normales
5" Exposure
Exposicion
Mansard or Area pars
High Wind desvenes y
Areas vientos fuertes
r1' 2' SBI rz" ,-
Figure 4: Minimum Nailing, Supreme
(Standard Size)
Normal
Wind Areas
Area pore vientos normales
ri +z t
5 5/8" Exposure
Exposicion
Mansard or Area pare
High Wind deavanes y
Areas vientos fuertes
( V z' SBl z' 1'�
Figure 5: Minimum Nailing, Supreme
(Metric Size)
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate ojAuthorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 5 of 10
6.3.1.2 Berkshire®:
Sealai i'Wlp'
Ta3Jra de saJlada
Figure 6: 5-Nail Pattern, Berkshire
Sealant strip
Le fire de sellader
8 +/2 8 Vz° 8 1W owl
r
Figure 7: 6-Nail Pattern, Berkshire
Figure 8: Mansard or Steep Slope Pattern, Berkshire
MEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate afAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 6 of 10
O.'NEM'oletc.
6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition®. Duration® Designer Color
Collection:
Figure 9: StantlarCl 4-luau Pattern, uuratlon
6-Nail Fastening, Pattern:
SureNall® fastening area width
Nail; Typical„
,12" 1"
tlrw�ns:CnnQnQ
Bw�eu49... ^'mr •"I���°i �I: 2ashS 8uiama s.,ia*4�'; x�.9�,U.�em Cnrrtm,¢.SrtrxKad� ,:�y��.�..
6118'�5618"
h�
Figure 10: 6-Nail Pattern, Duration
';Fastening,.for Siopes`GYeater.Tfian`21.:12;
$ureNak) fastening area width
Nail; Typical
12" 12" Tr
"�MonSCW1iN01"roN37„M "�~„' A�$N 156WNOJ 5"iX-0.. .G.5'ri—Coming SurCKul* •�":`
CYVC 4
Four 1",Spots'of Asphalt Roofing Cement:
Figure 11: Mansard or Steep Slope Pattern, Duration
MEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 7 of 10
6.3.1.4 TruDefinition* Oakridse®, Oakridse®:
WNail Pattern ,
lsquema con 4 clavos;
Exposure ,.. r'OatlVs
gxp6sieldirde55/8pyfg. Ctavos
`5 5/8 Exposme,
'Erposlel6nde5b/Spufg.
Figure 12: Standard 4-Nail Pattern, Oakridge
6.3.1.5 WeatherGuard® HP:
GAail Pattern_
Esguema con S clavos.
5518 Exposure
Fxposrc10!? 5b/B0u14
UN�NEMO etc.
5 5/8 Exposure;
>FXpD57GOR dEJr 5(S pvlg.
Figure 13: 6-Nail Pattern, Oakridge
Fastening for Slopes. Greater; Than 2112:.
SureNali® fastening area,wldthr
Naii typical
12 12
Four 1" to6ts of MphaitRobfing. Cement,
6Nall Pattern
Esquema con 6 clavos Nail 6118" from bottom
of shingle
Clear
5 518: Exposure 6 fasteners pte a 6118 ppu)g. de la
Ezposici6n de 5 518 pulg. 6 su)etallores1. parts inferior de la teJa
12"
I� 2• -�'I i'� ,2 I
q
Claw
WS Claw —
5 51s• ErQOR" 5 51s, E� oave Four 1" Spots of Asphalt Hoof Cement
f�gasdbnde 5 5l3 ptu Fxpt�¢gdn �, 5 518 PA.
cuatropuntos de cemerito de tatho de eslatto de 1 p4ada
Figure 1S: 6-Nail Pattern, WeatherGuard HP Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
NEMO ETC, LLC Evaluation Report 037940.02.12-Ril
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.30674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 8 of 10
OONEMojetc.
6A.,' HIP AND RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire' Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1. Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction
4 Direccion del viento predominante
0
Nails A
Clavos —4
I I
I I
A I I
4 I I
I I I
I I I I
I I
FB"Ezposure
Exposition de S pulg
A
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles:
E—;Prevailing Wind
Direction « A
A-
Nulls" q q,
i I.. • r> 1.
`i'
ExpoSsure
Fig. B Top View
Vista superior
t" 1"IH
Nail
2s/a' Clavo
° , Owens Coming SureNal>�
I
I
cl e
8`7=1.0
mI
I
I
12"
Figure 18: Plan View, Berkshire and DuraRidge
Fig."-' Hip,&:Ridge Shingle Fastening,
?opylew
Nails, Nails,
7"
51, Exposure
124
Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20: Plan View, WeatherGuard HP Hip and Ridge
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate oJAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 9 of 10
6.4.1.3 ProEdge®:
Prevailing
Wind Direction Sealant Strip
6' Exposure
Fasten 711?
r Cover Exposed 0
Fasteners with
Roof Cement
Figure 21: Isometric View, ProEdge
Standard
Fastening
Pattern
92° I
7�� u
*.NEM0 etc.
Sealant
Figure 22: Plan View, ProEdge
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate ojAuthorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.30674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 10 of 10