Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Approval; Underlayments RoofingW ._
BCIS Home I Log In ( User Registration ( Hot Topics ( Submit Surcharge I
' 'Product Approval
-USER: Public User
s
Stats & Facts ' Publications Contact Us BCIS Site Map Links Search
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
FL2569-R21
Revision
RECEIVED
Code Version
Application Status
2020
Approved
JUN 0 4 2021 .
St. Lucte County, Permitting
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean -Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
...1 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
€a Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R21 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2015
FM 4474
2011
FRSA/TRI Sixth Edition
2018
UL1897
2015
Equivalence of Product.Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
12/16/2020
12/17/2020
12/26/2020
02/09/2021
FL #
Model, Number or Name
Description
2569.1
Soprema Roof Underlayments
Self adhering roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FL2569-
R21.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
Evaluation Reports
design pressure noted herein pertains to underlayment systems
FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569-
R21.pdf
used beneath adhesive -set tile systems. Refer to ER Section
5.8.3 for details.
1 Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copy i ht 2007-2013 State of Florida.:: Privacy Accessibiftg Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by.traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
s
MEMO I Etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
Soprema, Inca
1640 rue Haggerty
Drummondville, Qu6bec J2C 5P8 Canada
(819)478-2400
Evaluation Report S18010.06.09-1119
FL2569-R21
Date of Issuance: 06/15/2009
Revision 19: 12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the Ph Edition (2020) Florida Building Code sections noted herein.
A
DESCRIPTION: `Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative.to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing was authorized by Robert
',`65�` "4 `ik .',•' >
•70�AL :.
Nieminen, P.E. on 12/16/2020. This does not serve as
„�a,;
an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is- a.building code evaluation. Neither NEMO ETC. LLCnor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
projes: on -which this Evaluation Report, or previous -versions thereof, is/was used for permitting or design guidance -unless retained
specifically for that purpose.
©2019 NEMO ETC, LLC
.0
ONEMO;
I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the 7" Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements.and Limitations / Conditions of Use
set forth herein.
Section.�
Propeft 7.
a Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2 / R905.11.2
Material standard
ASTM D6163
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
Enti � x
Examination_
�'_ Reference '�Date
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970 / TAS 110 (QC)
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
FRSA/TRI 04-12 (OH)
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 (OH)
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 (MS)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (BC)
S44870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970.(QC)
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592)
HVHZ Compliance
18-0329.03
06/28/2018
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-RI _
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-20-SSUDL-01
12/16/2020
PRI (TST5878)
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
NEMO ETC, LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 2 of 9
ME
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.15
4.16
NNEMOjetc.
" ,-
Material,Product
"
Plant(s)'
Description
Standard
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self-adhering, non -woven polyester fabric
Underlayment
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Lastobond Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment .
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand-R SA
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport, MS
- surfaced,-SBS modified -bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 3 of 9
4.17
4.18
4.19
4.20
ONEMOI etc.
Product
Material
Standard
,plant(s)
r' ' Description, ,.
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand=
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Colphene FR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
g i
a�t�
,�
i,
;- b
TABU4 ROOF9VEROPTIONS ai
- 4
° �
a i
b .e'-n ik,<."
a) �.,g .. .s. w. a
r ➢ 9• n,. YY
s` E
FBCSecdan:.
1507.2
1507.3
1507.4 & 1507.5 '
r ,1507.7
f.1507.8 & °1507.9 . r .!'
Clay and Concrete Tile '
Meta,
SlateFor
Undderlayment
-
Asphalt
Shingles,_.:
Slate -Type
Wood Shakes or
Shingles
Mechanical::,;
ie
, Adhesv- .
Panels
Shingles
Attach
Set "
Shingles
Lastobond TU HT, Tri-Built S/A HT TU
Yes
Yes
Underlayment
Yes
Yes
See 5.6.1
Yes
Yes
Yes
0oint strips, 1507.1.1.3/
R905.1.1.3)
Lastobond Shield, Pro HT-N, RESISTO SA
Yes
SMOOTH PLY40
Yes
No
No
No
No
Yes
(Joint strips,1507.1.1.3/ .
R905.1.1.3)
Yes
Lastobond Shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
(Joint strips, 1507.1.1.3/
R905.1.1.3)
Yes
EnviroShield
Yes
No
No
Yes
Yes
Yes
(Joint strips, 1507.1.1.3 /
R905.1.1.3)
Lastobond Eaves Protection Sheet,
Yes
Lastobond195
Yes
No
No
No
No
Yes
0ointstrips, 1507.1.1.3/
R905.1.1.3)
NEMO ETC, LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 4 of 9
NNEMO I etc.
o_
1ABLE1:-- ROOF COVER OPTIONS :`
FBCSection:
1507.2
150Z3
15OZ4 & 1507.5
150Z7
1507.8 & 1507.9
Clay -and Concrete Tile."
Metal
Slate or
Underlayment
Asphalt '
Slate -Type
Wood Shakes or
Mechanical
Adhesive-
-Shingles ,
Attach.
Set
Panels
Shingles
Shingles
Shingles
Lastobond ECO, RESISTO LB3236, TRI-
BUILT Sand-R SA Shingle Underlayment,
Yes
Grip -Rite Eave & Valley Protector,
Yes'
No
No
No
No
Yes
(joint strips, 1507.1.1.3/
TopShield ICE & WATER DEFENDER,
R905.1.13)
RE
Lastobond Smooth Seal HT, Tri-Built
Yes
Smooth HT S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
Qoint strips, 1507.1.1.3/
Smooth Seal HT
R905.1.13)
Yes
Colp a
Yes
Yes
No
No
No
Yes
Gointstrips, 1507.1.13/
R905.1.13)
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE'ZA. "ALLOWABLE. -TILE UNDERLAYMENT COMBINATIONS)
Underlayment
Adhesive
Florida Product Approval
Lastobond TU HT, Tri-Built S/A
HT TU Underlayment
Dupont "Tile Bondi"" Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polyset® AH-160"
FL6332
5.7 Allowable Substrates:
TABLE 2: °SUBSTRATE'.OPTIONS
F.dk'ADHERED'UNDERLAYMENTS u'v
Substrates (designed to meet wind loads for project) -
Underlaymept
Application -
-
Type
Primer
Material(s)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
plywood, OSB or Southern Yellow Pine
HT-N, RESISTO SA SMOOTH PLY
Deck /
D41, Elastocol Stick,
(SYP)
40, Lastobond Shield HT,
sheathing
Elastocol Stick Zero
ASTM D41
structural concrete
Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT,
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Tri-Built S/A HT TU
Insulation
Stick Zero
Fiber Roof Board
Underlayment, Lastobond Eaves
Protection Sheet, Lastobond 195,
self-
Lastobond ECO, RESISTO LB1236,
adhering
TRI-BUILT Sand-R SA Shingle
Underlayment, Grip -Rite Eave &
Valley Protector, TopShield ICE &
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or Modified Sopra-
WATER DEFENDER, RESISTO
Stick Zero
G
LB1244, Lastobond Smooth Seal
HT, Tri-Built Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
Deck /
(Optional) ASTM
Plywood
41
sheathing
ASTM D41
structural concrete
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum -
Col hene FR GR
p
adhering
add
Stick Zero
Fiber Roof Board
(Opting+— al Elastocol
ASTM D226, Type II felt orA&odified Sopra-
Base Sheet
Stick-Zero
G
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 5 of 9
N.NEM0 etc.
Substrates (designed to meet wind loads for project)::
Underlayment Application`+
Type- Primer Materials) ,
Lastobond TU HT, Tri-Built S/A HT
TU Underlayment, RESISTO
LB1236, TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand -surfaced, glass -fiber surfaced,
Shingle Underlayment, Grip -Rite mineral -surfaced or film, -surfaced roof
Eave & Valley Protector or adhering substrate PRIMER underlayment*
TopShield ICE & WATER
DEFENDER
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT, Tri-Built S/A HT
TU Underlayment RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE &
WATER DEFENDER self -adhering underloyments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of f the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but — for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and, Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop. Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
NEMO ETC, LLC Evaluation Report S18010.06.09-1139
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
NNEMOletc.
#3 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#4 Maximum Design Pressure = -150.0 psf:
Deck: —Min. 15/32-jnch AP_A-rated BCX plywood (may be installed C-side up) to meet project requirements -to-
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC'1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch, o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
- TABLE 3 EXPOSURE LIMITATIONS,'
Underlayment ..
Prepared Roof Cover
Maximum
-.
Installation Type
Exposure (days)
Lastobond Eaves Protection Sheet, Lastobond.195,Lastobond Eco, RESISTO 1_131236, TRI-
Mechanically
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE
attached
30
& WATER DEFENDER or RESISTO LB1244
Lastobond TU HT, Tri-Built S/A HT TU Underlayment
Adhesive -set the roof
30
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Mechanically
Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A
attached
90
Underlayment or Grip -Rite Smooth Seal HT
Lastobond TU HT, Tri Built S/A HT TU Underlayment or Colphene FR GR
Mechanicallyattached
180
NEMO ETC, LLC Evaluation Report S38010.06.09-1119
Certificate ojAuthorizotion #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 7 of 9
ONEMO etc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
�TABLE4 SLIPPAGE LIMITATIONS DIRECT DECKTILE INSTALLATIONS>
;TILE FOR
.�.„ ,
Underlayment"
Tile Profile
Staging Method"
Maximum"Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 104ile stack
5:12
Max.10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
Lastobond TU HT, Tri-G�,�
Built SSA HT TU
Underlayment
Lugged
gg
M
�
'^ Py 2�
Colphene FR GR
Flat
Max. 10-tile stack
5:12
Lugged
Max. 10-tile stack
6:12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO L61236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayrrients,.contact RESISTO technical support. .
b.3.1 Non -I lie Applications,
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC, LLC Evaluation Report S18010.06.09-1119
Certificate ofAuthorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FI.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020,
Page 9 of 9