Loading...
HomeMy WebLinkAboutShingle9/20/21, 1:26 PM Florida Building Code Online Professional ��il A.. BCIS Home I Log In User Registration j Hot Topics Submit Surcharge i Stats & Facts ? Publications ! Contact Us j BCIS Site Map ( Links i Search I 'da , raProduct Approval USER: Public User •rca�t�cw & .+rak�2agn Product AQoroval Menu > Product or Agnlication Search > Application List > Application Detail FL # FL10674-R16 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10674 R16 COI 2020 01 COI NIEMINEN.pd Standard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 Year 2015 2016 2010 2019 Sections from the Code hftps://floddabuilding.org/pr/pr_app_otl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEAIpOjcKTwWbw%3d%3d 1/2 9/20/21, 1:26 PM Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 12/11/2020 12/17/2020 12/26/2020 02/09/2021 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, laminated, starter and hip & ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT Approved for use outside HVHZ: Yes SHINGLES FL10674-R16.pd Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT SHINGLES 1`1_10674-R16.12d Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Qp right 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MoMMERE Credit Card Safe https://floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQvADgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEAIpOjcKTwWbw%3d%3d 2/2 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION Owens Corning Evaluation Report 037940.02.12-1111 One Owens Corning Parkway FL10674-1116 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 11: 12/11/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. '• fi:,�_ s�: The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 �'�,FS� Nieminen, P.E. on 12/11/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018 NEMO ETC, LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: SCOPE:1. Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 3. REFERENCES: Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 ULLLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current ..ODDESCRIPTION: TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plant Materials) Standard Description Starter Strip Shingle H-TX, OR Starter Strip Plus MN, OR Accessory ASTM D3462 starter strips for asphalt roof shingles Starter SRS TopShield Starter MN, OR Strips Starter Shingle Roll NH ASTM D1970 mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter Supreme GA, CA, CO, I -TX, NJ, OH, TN, OR, IL ASTM D3462 fiberglass reinforced 3-tab asphalt roof shingles Berkshire* MN ASTM D3462 fiberglass reinforced, 4-tab asphalt roof shingles Duration* Premium CA, OR Duration' Premium COOL CA Asphalt Shingles ASTM D3462 fiberglass reinforced, laminated asphalt roof shingles TruDefinition* Duration* IN, CA, CO, I -TX, FL, NJ, OH, MN, OR, GA, IL, TN TruDefinition* Duration* Designer Color Collection Oakridge* GA, IN, CA, CO, H-TX, I -TX, FL, NJ OH, TN TruDefinition* Oakridge* H-TX, I -TX WeatherGuard' HP TN NEMO ETC, LLC Evaluation Report 037940.02.12-R31 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 2 of 10 ONEMOletc. TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Standard Description Berkshire Hip and Ridge Shingles with Sealant MN DuraRidge® Hip and Ridge MN Hip and fiberglass reinforced, hip and ridge Ridge Shingles with Sealant ASTM D3462 asphalt roof shingles ProEdge® GA, CA, OH, OR Shingles WeatherGuard' HP Hip and Ridge Shingles TN 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Supreme' ASTM D3161(F) & ASTM D7158(H) Berkshire' Duration' Premium Duration' Premium COOL TruDefinition' Duration' TruDefinition' Duration' Designer Color Collection Oakridge' TruDefinition' Oakridge' WeatherGuard' HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC, LLC Evaluation Report 037940.02.12-1131 Certificote ofAuthorizotion #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 3 of 10 ONEMOletc. TABLE 2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE Type Product FBC Table 1507.2.7.1 or R905.2.6.1 Starter Strips Starter Strip Shingle ASTM D3161, Class F Starter Strip Plus SRS TopShield Starter Hip & Ridge Shingles Berkshire Hip and Ridge Shingles with Sealant ASTM D3161, Class F DuraRidge® Hip and Ridge Shingles with Sealant ProEdge® WeatherGuard' HP Hip and Ridge Shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Felt undwlsyment — Deck Soafieed we thetlock' urdarlaymak +doDrifr,— Drip edge Kith located Y-Y irum e.w kbrngn� SaBawkng ed esiw S reidt _i positionrd akxp save e" remawd Stater Strip shk*e owrhaigs saws and rakes Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO ETC, LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 4 of 10 ONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. IBM Underlayment Starter Shingle Roll adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard* HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Normal Mansard or Area pare Wind Areas High Wind desven*s y Area pare vientos normal" Areas vientos fuertes 1• IA) 1• r-1 2• (B 2• 1•, tr 1r 5" Exposure Exposicidn Figure 4: Minimum Nailing, Supreme (Standard Size) Normal Mansard or Area pars Wind Aroma High Wind desvnnos y Area pare vientos normal*# Areas vientos fuerte# i12 (A) art 1• 1. 2 (el 2• 1. 5 5/E` Exposure Exposioldn Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-1171 Certificate of Authorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 5 of 10 6.3.1.2 Berkshire®: Sealant strip La tLa fie sonador Figure 6: 5-Nail Pattern, Berkshire ONEMO I etc. Figure 7: 6-Nail Pattern, Berkshire Sealant strip Le t&a de wiWor •4---------- ► 0 4---► • • .---... . • Q8 Yf 8 Yz" 8 Yf t C Asphakrooting cement Cemanto do lochoda a,;Wo Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Certificate of Authorization #32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION Owens Corning Asphalt Roof Shingles Evaluation Report 037940.02.12-Rll FL10674-R16 Revision 11: 12/11/2020 Page 6 of 10 NNEMO I etc. 6.3.1.3 Duration' Premium, TruDefinition' Duration, Duration' Premium COOL & TruDefinition® Duration' Designer Color Collection: Figure 9: Standard 4-Nail Pattern, Duration Figure 10: 6-Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 SureNalh:*) fastening area width Nail, Typical 1"E 12" i � 12" 1" 'k Ff 8-178" 5_518" e,00«+re ?16;" 2.. Four 1" Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern, Duration NEW ETC, LLC Evaluation Report 037940.02.12-1111 Certificate of Authorizotion#32455 7`" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 7 of 10 6.3.1.4 TruDefinition®Oakridge°, Oakridge®: 4 Nail Pattern Esquerna con 4 clavos r I-*-- rz- 12- 55/8" Exposure Nails 55/8"Exposure Expogdcindo55/8pulq. C1jvcK Exposici6ndo6G18ptdq. Figure 12: Standard 4-Nail Pattern, Oakridge 6.3.1.5 WeatherGuard® HP 6 NJI Pattarn Esquema con S clavos 5 519" Exposure Erposicidn de 55/9pulq. NNEMO I etc. n - 5 5/9" Exposure Exposicidrr de 661C pulp. Figure 13: 6-Nail Pattern, Oakridge 6 Nail Pattern Esquema con 6 clavos 5 5T Exposure f Exposici5n de 5 61 pulg. xA Dam — Nail 1,8" from bottom of shinoe 6 Fasteners Cleve a 6 118 pulp. de la 6 sujetadores Pie inferior de la teja 5 5 5 8' Four 1" Spots of Asphalt Roof Cement 58 D�k. ExDarSciBn de 5 putp. rn �potie Cuatro puntos de ceento de techo de asfdto de 1 putgada rposicti6n di 5 ��B Figure 15: 6-Nail Pattern, WeatherGuard HP Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP NEMO ETC, LLC Evaluation Report 037940.02.12-Rll Certificate of Authorization#32455 7`" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 8 of 10 *NEM0 I etc. 6.4 HIP AND RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard* HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge° Hip and Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction +— Direccion del viento predominante I cl 42L--v V I I i i I I �li E.SpOSU(Q posicioo de i pul A Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard' HP Hip and Ridge Shingles: Fig.A 44 Prevailing N10d F— Direction p �` Nails i I A I A i � I r I A i I I r 1 I I r s —,{ Ezpaauro Fig. B Top view Vista superior Nail Clevo �I 12" (tIi �P 2%" • Owens Doming Sura^la6' • I I I� � U I I Figure 18: Plan View, Berkshire and DuraRidge Fig. C Hip & Ridge Shingle Fastening ew Top Vi Nails Nails r' z z„ 1' t' t r�s S, Expoauro tr Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20: Plan View, WeatherGuard HP Hip and Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization#32455 T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 9 of 10 6.4.1.3 ProEdge®: Prevailing Wind Direction rent Strip 6' Exposure Fasten 71b' Cover Exposed Fasteners with Roof Cement Figure 21: Isometric View, ProEdge ONEMO I etc. Standard Fastening Pattern 12' Saiatt � h 8' E>tpawd�►• Figure 22: Plan View, ProEdge BUILDING7. • As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - NEMO ETC, UC Evaluation Report 037940.02.12-R31 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 10 of 10