Loading...
HomeMy WebLinkAboutWind Loads ,'J II IIiI� 1 1 =� Easy �IS ASCE 7-16 Design Wind Loads Wind speed V= 160 mph Exposure D For Wall Components & Cladding Ke= 1.0 /LSD Load Combination Coeff.0.6 easys2als.com Wind Pressures[psf]For use with Allowable Stress Design KZt= 1.0 Kd= 0.85 Enclosed Bldg GCpi= 6.18 Triburary area at least... Triburary area at least... Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Mean 10 sg ft 15 sg ft 20 sg ft 25 sg ft 30 sg ft 35 sg ft 40 sg ft 50 sg ft Roof Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zane 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Height Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner 60'to: + + + + + + + + + + + - + I - + - + - + I - + - 61 ft +47.5-47.5 +47.5-87.0 +47.5-47.5 +47.5-87.0 +47.5-47.5 +47.5-87.0 +46.5-46.9 +46.5-84.6 +45.8-46.4 +45.8-82.6 +45.2-45.9 +45.2-80.9 +44.6-45.6 +44.6-79.4 +43.7-45.0 +43.7-77.0 65 ft +48.0-48.0 +48.0-88.0 1 +48.0-48.0 +48.0-88.0 +48.0-48.0 +48.0-88.0 +47.1-47.4 +47.1-85.5 +46.3-46.9 +46.3-83.5 +45.7-46.4 +45.7-81.8 +45.1-46.1 +45.1-80.3 +44.2-45.5 +44.2-77.9 70 ft +48.6-48.6 +48.6-89.1 +48.6-48.6 +48.6-89.1 +48.6-48.6 1 +48.6-89.1 +47.7-48.0 1 +47.7-86.6 +46.9-47.5 +46.9-84.6 +46.3-47.0 +46.3-82.9 +45.7-46.7 +45.7-81.4 +44.8 46.0 1 +44.8-78.9 75 ft +49.2-49.2 +49.2-90.2 +49.2-49.2 +49.2-90.2 +49.2-49.2 +49.2-90.2 +48.3 48.6 +48.3-87.7 +47.5-48.0 +47.5-85.6 +46.8-47.6 +46.8-83.9 +46.3-47.2 +46.3-82.3 +45.3-46.6 +45.3-79.8 80 ft +49.8-49.8 +49.8-91.2 +49.8-49.8 +49.8-91.2 +49.8-49.8 +49.8-91.2 +48.8-49.1 +48.8-88.7 +48.0-48.6 1 +48.0-86.6 +47.4-48.1 +47.4-84.8 +46.8-47.8 +46.8-83.3 +45.8-47.1 +45.8-80.7 85 ft +50.3-50.3 1 +50.3-92.2 +50.3-50.3 +50.3-92.2 +50.3-50.3 +50.3-92.2 +49.3-49.6 +49.3-89.6 +48.5-49.1 +48.5-87.5 +47.9 48.7 +47.9-85.7 +47.3 48.3 +47.3-84.2 +46.3-47.6- +46.3-81.6 90 ft +50.8-50.8 +50.8-93.1 +50.8I-50.8 +50.8-93.1 +50.8-50.8 +50.8-93.1 +49.8-50.1 +49.8-90.5 +49.0-49.6 +49.0-88.4 +48.3-49.1 +48.3-86.6 +47.7 48.8 +47.7-85.0 +46.8 48.1 +46.8-82.4 95 ft +51.3-51.3 +51.3-94.0 +51.3-51.3 +51.3-94.0 +51.3-51.3 +51.3-94.0 +50.3-50.6 +50.3-91.3 +49.5-50.1 +49.5-89.2 +48.8-49.6 +48.8-87.4 +48.2-49.2 +48.2-85.8 +47.2-48.6 +47.2-83.2 100 ft +51.7-51.7 +51.7-94.8 +51.7-51.7 +51.7-94.8 +51.7-51.7 +51.7-94.8 +50.7-51.1 +50.7-92.2 +49.9-50.5 +49.9-90.0 +49.2-50.1 +49.2-88.2 +48.6-49.7 +48.6-86.6 +47.6-49.0 +47.6-83.9 105 ft +52.2-52.2 +52.2-95.6 +52.2-52.2 +52.2-95.6 +52.2-52.2 +52.2-95.6 +51.2-51.5 +51.2-93.0 +50.3-50.9 +50.3-90.8 +49.6-50.5 +49.6-88.9 +49.0-50.1 +49.0-87.3 +48.0-49.4 +48.0-84.6 110 ft +52.6-52.6 +52.6-96.4 +52.6-52.6 +52.6-96.4 +52.6-52.6 1 +52.6-96.4 +51.61-51.9 +51.6-93.7 +50.7-51.4 1 +50.7-91.5 +50.0-50.9 +50.0-89.6 +49.4-50.5 +49.4-88.0 +48.4-49.8 +48.4-85.3 115 ft +53.0-53.0 +53.0-97.2 +53.0-53.0 +53.0-97.2 +53.0-53.0 1 +53.0-97.2 +52.0-52.3 +52.0-94.4 +51.1-51.8 +51.1-92.2 +50.4-51.3 +50.4-90.3 +49.8-50.9 +49.8-88.7 +48.8-50.2 +48.8-86.0 120 ft .+53. -53.4 +53.4-97.9 +53.4-53.4 +53.4-97.9 +53.4-53.4 +53.4-97.9 +52.4-52.7 +52.4-95.1 +51.�-52.1 '+51.5-92.9 +50.8-51.7 +50.8-91.0 +50.2-51.3 +50.2-89.4 +49. -50.6 +49.2-86.6 125 ft +53.8-53.8 +53.8-98.6 +53.8-53.8 +53.8-98.6 +53.8-53.8 +53.8-98.6 +52.7-53.1 +52.7-95.8 +51.9-52.5 +51.9-93.6 +51.2-52.0 +51.2-91.7 +50.6-51.6 +50.6-90.0 +49.5-50.9 +49.5-87.2 130 ft +54.1-54.1 +54.1-99.3 +54.1-54.1 +54.1-99.3 +54.1-54.1 +54.1-99.3 +53.1-53.4 +53.1-96.5 +52.2-52.9 +52.2-94.2 +51.5-52.4 +51.5-92.3 +50.9-52.0 +50.9-90.6 +49.9-51.3 +49.9-87.8 135 ft +54.5-54.5 +54.5-99.9 +54.5-54.5 +54.5-99.9 +54.5-54.5 +54.5-99.9 +53.4-53.8 +53.4-97.1 +52.6-53.2 +52.6-94.8 +51.9-52.7 +51.9-92.9 +51.21-52.3 +51.2-91.2 +50.2-51.6 +50.2I-88.4 140 ft +54.8-54.8 +54.8-100.5 +54.8-54.8 +54.8-100.5 +54.8-54.8 +54.8-100.5 +53.8-54.1 +53.8-97.7 +52.9-53.6 +52.9-95.4 +52.2-53.1 +52.2-93.5 +51.6-52.7 +51.6-91.8 1 +50.5-51.9 +50.5-89.0 145 ft +55.2-55.2 +55.2-101.2 +55.2-55.2 +55.2-101.2 +55.2-55.2 +55.2-101.2 +54.1-54.5 +54.1-98.3 +53.2-53.9 +53.2-96.0 +52.5-53.4 +52.5-94.0 +51.9-53.0 +51.9-92.4 +50.8-52.3 +50.8-89.5 150 ft +55.5-55.5 +55.5-101.8 +55.5-55.5 +55.5-101.8 +55.5-55.5 +55.5-101.8 +54.4-54.8 +54.4-98.9 +53.6-54.2 +53.6-96.6 +52.8-53.7 +52.8-94.6 +52.2-53.3 +52.2-92.9 +51.1-52.6 +51.1-90.0 155 ft +55.8-55.8 +55.8-102.3 +55.8-55.8 +55.8-102.3 +55.8-55.8 +55.8-102.3 +54.7-55.1 +54.7-99.5. +53.9-54.5 +53.9-97.1 +53.1-54.0 +53.1-95.1 +52.5-53.6 +52.5-93.4 +51.4-52.9 +51.4-90.6 160 ft +56.1-56.1 +56.1-102.9 +56.1-56.1 +56.1-102.9 +56.1-56.1 +56.1-102.9 +55.0-55.4 +55.0-100.0 +54.2-54.8 +54.2-97.7 +53.4-54.3 +53.4-95.7 +52.8-53.9 +52.8-93.9 +51.7-53.2 +51.7-91.1 165 ft +56.4-56.4 +56.4-103.5 +56.4-56.4 +56.4-103.5 +56.4-56.4 +56.4-103.5 +55.3-55.7 +55.3-100.6 +54.5-55.1 +54.5-98.2 +53.7-54.6 +53.7-96.2 +53.1-54.2 +53.1-94.5 +52.0-53.5 +52.0-91.6 170 ft +56.7-56.7 +56.7-104.0 +56.7-56.7 +56.7-104.0 +56.7-56.7 +56.7-104.0 +55.6-56.0 +55.6-101.1 +54.7-55.4 +54.7-98.7 +54.0-54.9 +54.0-96.7 +53.3-54.5 +53.3-94.9 +52.2-53.7 +52.2-92.0 175 ft +57.0-57.0 +57.0-104.5 +57.0-57.0 +57.0-104.5 +57.0-57.0 +57.0-104.5 +55.9-56.3 +55.9-101.6 +55.0-55.7 +55.0-99.2 +54.3-55.2 +54.3-97.2 +53.6-54.7 +53.6-95.4 +52.5-54.0 +52.5-92.5 180 ft +57.3-57.3 +57.3-105.0 +57.3-57.3 +57.3-105.0 +57.3-57.3 +57.3-105.0 +56.2-56.6 +56.2-102.1 +55.3-56.0 +55.3-99.7 1 +54.5-55.4 +54.5-97.7 +53.9-55.0 +53.9-95.9 +52.8-54.3 +52.8-92.9 185 ft +57.6-57.6 +57.6-105.5 +57.6-57.6 +57.6-105.5 +57.6-57.6 +57.6-105.5 +56.5-56.8 +56.5-102.6 +55.6-56.2 +55.6-100.2 +54.8-55.7 +54.8-98.1 +54.1-55.3 +54.1-96.3 +53.0-54.5 +53.0-93.4 190 ft +57.8-57.8 +57.8-106.0 +57.8-57.8 +57.8-10"0 +57.8-57.8 +57.8-106.0 +56.7-57.1 +56.7-103.1 +55.8-56.5 +55.8-100.6 +55.0-56.0 +55.0-98.6 +54.4-55.5 +54.4-96.8 +53.3-54.8 +53.3-93.8 195 ft +58.1-58.1 +58.1-106.5 +58.1-58.1 +58.1-106.5 +58.1-58.1 +58.1-106.5 +57.0-57.3 +57.01-103.5 +56.1-56.7 +56.1-101.1 +55.3-56.2 +55.3-99.0 +54.6-55.8 +54.6-97.2 +53.5-55.0 +53.5-94.3 200 ft +58.4-58.4 +58.4-107.0 +58.4-58.4 +58.4-107.0 +58.4-58.3 +58.4-107.0 +57.2-57.6 +57.2-104.0 +56.3-57.0 +56.3-101.5 +55.5-56.5 +55.5-99.5 +54.9-56.0 +54.9-97.7 +53.7-55.3 ,+51 -94.7 LLn •Design conforms to the Florida Building Code 7th Ed(2020). •Wind Speed noted above Is ultimate design wind speed(3-second gust). •Zones 4&5("interior"and"corner"zones,respectively)are as shown to e 1 Valid only w h e gineer's •Tabulated design wind loads are based on ASCE 7-16 specifications for •Plus(+)&minus(-)signs signify pressures acting toward and away from the right,where the dimension"a"Is the minimum of 10%of the building's Osignaitu�e rail d seal components and cladding based on design criteria as noted herein. the exterior component or cladding surface,respectively. least horizontal dimension or 40%of the mean roof height,but never less Z •Where this document Is used for permit,applicability of design criteria •Where"Mean(average)Roof Height"cannot be determined,peak roof than 3'-0"or 4%of the least horizontal dimension. J noted herein(Basic Wind Speed,Exposure Category,Risk Category,etc.) height shall be used,except that eave height shall be used for roof angle •This specification is valid only for use with structures NOT located in the zone `f shall be verified by the contractor&building official prior to construction. less than or equal to 10%Round up to values shown upper one-half of an isolated hill,ridge or escarpment,&below 1000'elev. 4 i 5 J)r! 3 1 C •This specification may be used in conjunction with engineering under •Wind pressures are applicable to all building floors. •This specification is valid for use with buildings of any Risk Category, _ `- LU separate certification(by this engineer or by others)using Allowable Stress •Tabulated wind pressures are valid for all roof slopes;no reduction for Including essential facilities and buildings or other structures that WDesign(ASD). roof slopes 10°has been considered. represent a substantial hazard to human life In the event of failure. i Christian, anggl ,PE. U •Refer to the above-noted ASCE 7 standard for descriptions and •Tributary Area noted In table(effective wind area)is equal to the •Design Is based on structure classification as Enclosed Bldg #67382 definitions of all design criteria. minimum of[height x width]or[ht x ht/3].Round dawn to values shown. well cicvennu FL 31124 1200 N Federal Hwy,#200,Boca Raton,FL 33432 Copyright©2021 Easy Seals rev 0121 boC PE PE = y A# ;INi6.lA16M5.160D Customer: Mceachem,Barbara WorkOrder Number: 08242021003N301 Unit No. Wall Opening Opening Shutter Shutter Slat Anchor Pressure Width Height Width Height Length Spacing 1 -53.4 34 45 46.875 50 46.75 9"o.c. 9"o.c. 2 -50.6 176.625 96.75 176.625 96.75 93.5 9"o.c. .-ICE 3 -52.1 74 61.25 88 66.25 63 9"o.c. O C I O z 9"o.c. ST. Lucie County, Permitting -J