Loading...
HomeMy WebLinkAboutEngineering AL-FAROOQ CORPORATION CONSULTING ENGINEERS & PRODUCT DEVELOPMENT PRODUCT APPROVAL EVALUATION RULE CHAPTER#61G20-3 • METHOD 1 OPTION D Detailed Product Description: REVIEWED FOR �®®� C Manufacturer:VIWINCO, INC. 1 HN44 NCE Manufacturer Address: PO BOX 499, MORGANTOWN,PA 19543 ST. LUCIE COIN 1 T Model Name:OCEANVIEW SERIES VINYL SINGLE HUNG WINDOW ROCC Maximum Load:+70 PSF,-70 PSF(Large Missile Impact) Fije Installation Drawings#19-20F ®�37 This product does not comply with the High Velocity Hurricane Zone(HVHZ)testing requirements. For maximum sizes,combination of span vs loads and anchor type refer to installation drawings. Comparative analysis used X Yes _No Mandatory Tests(Tested in accordance with AAMA/WDMA/CSA 101/I.S.2/A440/NAFS) Test Description Test Location Test Report Date Test Report#. 1/10/2008 76646.01-109-47 ASTM E283 Air Infiltration Architectural 12/5/2007 75147.01-109-47 Leakage Testing 8/15/2011 B1834.01-109-47 7/19/2011 B1833.01-106-47 ASTM E331&ASTM Water Penetration Architectural 1/10/2008 76646.01-109-47 E547 Testing 12/5/2007 75147.01-109-47 8/15/2011 B1834.01-109-47 11/13/2007 75595.01-109-47 7/19/2011 B1833.01-106-47 ASTM E330 Uniform Static Air Architectural 1/10/2008 76646.01-109-47 Press. Testing 3/26/2014 D0902.03-109-47 12/5/2007 75147.01-109-47 8/15/2011 B1834.01-109-47 8/6/2015 E8004.01-109-47 11/13/2007 75595.01-109-47 7/19/2011 B1833.01-106-47 ASTM F588 Forced Entry Test Architectural 1/10/2008 76646.01-109-47 Testing 12/5/2007 75147.01-109-47 8/15/2011 B1834.01-109-47 7/19/2011 B1833.01-106-47 9360 Sunset Drive STE 220 1 Miami, FL 33173 1 T:305.264.8100 1 F:305.262.69781 www.afceng.com I alfarooq@afceng.com Supplemental Tests Test ' Description Test Location Test Report Date Test.Report# 1/15/2008 75581.01-109-47 10/14/2013 D0902.02-109-47 11/20/2007 76955.01-109-47 Large Missile Architectural 2/16/2008 80365.01-109-47 ASTM E1886/1996 Impact&Cyclic Testing 8/16/2011 B1832.01-109-47 5/15/2009 88662.01-109.47 8/6/2015 E8004.02-109-47 11/12/2007 75560.02-109-47 6/30/2011 1 B1074.01-109-47 Under the limitations of the attached installation drawings,to the best of my knowledge and ability,the above product conforms to the requirements of the 2020 Florida Building Code. Evaluation Report Engineer: 4° O`i t/i+l, FAR "\` 4 90, 14 IV Jalal Farooq PE#81223 AI-Farooq Corporation EB#3538 Sealed: 3/9/2021` 9360 Sunset Drive STE 220 1 Miami, FL 33173 T:305.264.8100 F:305.262.6978 1 www.afceng.com l alfarooq@afceng.com