Loading...
HomeMy WebLinkAboutAPPROVED-UNDERLAYMENTPRODAPPR2/10/2021 Florida Building Code Online BCIS Home 1 Log In I User Registration I Hot Topics I Submit Surcharge Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method =lorida Engineer or Architect Name who developed the valuation Report =lorida License 2uality Assurance Entity duality Assurance Contract Expiration Date /alidated By :ertificate of Independence referenced Standard and Year (of Standard) FL12328-R9 Revision 2020 Approved TAMKO Building Products LLC PO Box 97 Galena, KS 66739 (417)624-6644 Ext2305 kerri—eden@tamko.com Kerri Eden kerri—eden@tamko.com Kerri Eden PO Box 1404 Joplin, MO 64802 (417)624-6644 Ext2305 kerri_eden@tamko.com Roofing Underlayments Evaluation Report from a Florida Registered Archii Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 10/18/2021 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL12328 R9 COI 2020 01 COI NIEMINEN pdf Standard ASTM D1970 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 1/3 2/10/2021 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products ASTM D226 ASTM D6380 Method 1 Option D 09/29/2020 10/04/2020 10/12/2020 12/15/2020 FL # Model, Number or Name Description 12328.1 TAMKO Roof Roof underlayments for use in FBC HVHZ jurisdictions. Underlayments (HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL12328 R9 II 2020 09 229 FINAL ER TAMKO UNDERL Approved for use outside HVHZ: No R9 pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: See ER Section 5 for Limits of Use. Evaluation Reports FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDER R, p_-df 12328.2 TAMKO Roof Roof underlayments for use in FBC non-HVHZ jurisdictions Underlayments (NON- HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R9 II 2020 09 29 FINAL ER TAMKO UNDERL Approved for use outside HVHZ: Yes HVHZ FL12328-R9 p fJff Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: See ER Section 5 for Limits of Use. Evaluation Reports FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDER HVHZ FL12328-R9 pdf Created by Independent Third Party: Yes .Bach Nix Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 done: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility St Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please cor Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I if they have one. The emails provided may be used for official communication with the licensee. However email addresses are to supply a personal address, please provide the Department with an email address which can be made available to the pL licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M W] NOW eCheck https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 2/3 2/10/2021 Florida Building Code Online Credit Card Safe hops://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 3/3 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION TAMKO Building Products, LLC Evaluation Report 3m-TAM-20-FBCER.A-RO PO Box 97 Galena, KS 66739 (417) 624-6644 FL12328-R9 Date of Issuance: 09/29/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: TAMKO Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANEl983 tillLtf(fJ-J,J "" t •h' The facsimile seal appearing was authorized by Robert °°Fs"•"wyy Nieminen, P.E. on 09/29/2020. This does not serve as an CERTIFICATION OF INDEPENDENCE: e ectronically signed document. I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019, NEMO ETC, LLC ROOFING COMPONENT EVALUATION F4,' 4.1 4.2 4.3 4.4 4.5 4.6 4.7 ONEMOletc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TAMKO Roof Underlayments, as produced by TAMKO Building Products LLC, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1507.1.1 / R905.1.1 Material standard ASTM D226 2009 1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 1507.2.9.2, 1507.6.5 / R905.2.8.2, Material standard ASTM D6380 2013 R905.5.4 Entity Examination Reference Date PRI(TST5878) ASTM D1970 TAP-388-02-01 10/04/2017 PRI(TST5878) ASTM D226,Type 11 TAP-420-02-01 04/19/2018 PRI(TSTS878) ASTM D1970 TAP-447-02-01 10/19/2018 PRI(TST5878) ASTM D6380 847T0009 12/21/2019 PRI(TST5878) ASTM D6380 847T00010 12/21/2019 PRI(TST5878) ASTM D226,Type 11 TAP-351-02-01 04/25/2016 PRI(TST5878) ASTM D226,Type 11 TAP-351-02-02 05/04/2016 UL LLC (TST9628) ASTM D226, Type 11 13CA12269 03/14/2014 UL LLC (QUA9625) Quality Assurance Service Confirmation 10/20/2020 UL LLC (QUA9625) Quality Assurance Florida BCIS r.... PRODUCT DESCRIPTION' Product Material Standard Plant(s) Description No. 30 UL ASTM D226, Type II Joplin, MO Asphalt -saturated organic felt Green Cove Springs, FL No. 30 ASTM ASTM D226, Type II Phillipsburg, KS Asphalt -saturated organic felt TAM -FELT° ASTM D226, Type II Green Cove Springs, FL Asphalt -saturated organic felt Moisture Guard® ASTM D1970 Joplin, MO Self -adhering, fiberglass reinforced SBS modified bitumen roof underlayment with a mineral top surface. Self -adhering, SBS modified bitumen roof TW Underlayment ASTM D19701 Columbus, KS underlayment with a polymer -film top surface. Self -adhering, SBS modified bitumen deck TW Seam Tape ASTM D1970 Columbus, KS ASTM Slate Surfaced Roll ASTM D6380, Green Cove Springs, FL seam -tape with a polymer -film top surface. Asphalt -saturated organic mat, coated Roofing Class M, Type II on both sides with asphalt and surfaced with granules. I Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance of TW Underlayment. NEMO ETC, LLC Certificate ofAuthorization #32455 Evaluation Report 3m-TAM-20-FBCER.A-R0 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL12328-R9 TAMKO Roof Underlayments Revision 0: 09/29/2020 Page 2 of 5 4.8 (N7) KIrILA IN 1 Product Material Standard Plant(s) IYCIVIU I C1.1.. Description ASTM Tile Underlayment ASTM D6380, Green Cove Springs, FL Asphalt -saturated organic felt, coated on Class M, Type II both sides with asphalt and surfaced with granules. 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 TAMKO Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Clay and Concrete Tile Underlayment fShingles (15OZ3) Metal Slate or Slate -Type wood Mechanical Adhesive- Panels Shingles Shingles Shingles Shakes Attach Set (15OZ4) (1507.5) (150Z7) (25OZ8) (1507.9) No. 30 UL Yes Yes Yes See 5.6.1 See 5.6.1 Yes Yes Yes Yes Yes No. 30 ASTM Yes Yes Yes See 5.6.1 See 5.6.1 Yes Yes Yes Yes Yes TAM-FELT00 Yes No No Yes Yes Yes Yes Yes Moisture Guard® Yes No No Yes Yes No No Yes (jointstrips, (jointstrips, 1507.1.1.3 / 1507.1.1.3 / R905.1.1.3) R905.1.1.3) Yes Yes TW Underlayment Yes No No Yes Yes Yes (jointstrips, (jointstrips, 1507.1.1.3 / R905.1.1.3) I 1507.1.1.3 / R905.1.1.3) Yes Yes (jointstrips, Yes Yes TW Seam Tape (jointstrips, NO NO Yes Dint strips, it P Yes Qoint strips, 1507.1.1.1/ R905.1.1.1) 1507.1.1.1 / 1507.1.1.1 / 1507.1.1.1 / (jointstrips, 1507.1.1.3 / (jointstrips, 1507.1.1.3 / ASTM Slate Surfaced Roll R905.1.1.1) R905.1.1.1) R905.1.1.1) 11905.1.1.3) R905.1.1.3) Yes Yes Roofing (Valley Liner) (Cap Sheet in 2- No No No No No No Ply system) ASTM Tile Underlayment Yes Yes (Valley Liner) (cap Sheet in 2- No NO NO NO No No ply system) NEMO ETC, LLC Certificate ofAuthorizotion #32455 Evaluation Report 3m-TAM-20-FBCER.A-RO 7TR EDITION (2020) FBC NON-HVHZ EVALUATION FL12328-R9 TAMKO Roof Underlayments Revision 0: 09/29/2020 Page 3 of 5 ONEMOletc. 5.6.1 No. 30 UL or No. 30 ASTM may be used as a mechanically attached anchor sheet followed by an asphalt -applied ASTM Slate Surfaced Roll Roofing or ASTM Tile Underlayment. 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates Moisture Guard® or TW Underlayment self -adhering (Optional) ASTM D41 plywood None No. 30 UL, No. 30 ASTM or TAM -FELT® TW Seam Tape self -adhering (Optional) ASTM D41 plywood ASTM Slate Surfaced Roll Roofing or ASTM Tile Underlayment hot asphalt None No. 30 UL, No. 30 ASTM or TAM -FELT® 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days)* No. 30 UL, No. 30 ASTM, TAM -FELT ® Moisture Guard®, TW Underlayment, TW Seam Tape Any 30 ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment *Maximum exposure shall not exceed the manufacturer's recommendations, which may be less than 30 days. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the tile shall be staged atop battens during loading of the roof tiles. 6.1 TAMKO Roof Underlayments shall be installed in accordance with TAMKO Building Products LLC installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 No. 30 UL, No. 30 ASTM: 6.3.1 Non -Tile Applications• Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. NEMO ETC, LLC Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report 3m-TAM-20-FBCER.A-RO 328-119 TAMKO Roof Underlayments FL Revision 0: 09/2 29/2020/2020 Page 4 of 5 6.3.2 Tile Applications: MEMO I etc. No. 30 UL or No. 30 ASTM are limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment applied in hot asphalt, or other FBC Approved hot -asphalt applied cap sheet. Refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 for attachment requirements. 6.4 TAM -FELT®: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5 Moisture Guard®, TW Underlayment: 6.5.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.6 ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment: 6.6.1 Tile Applications: ASTM Slate Surfaced Roll Roofing and ASTM Tile Underlayment are limited to use as the Hot Asphalt applied "Cap Sheet" in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. Refer to Section 5.8.2 for attachment limitations. Refer to Section 5.10 for the staging limitations. 6.6.2 Valley Liner: ASTM Slate Surfaced Roll Roofing and ASTM Tile Underlayment are acceptable for use as a valley liner in accordance with FBC 1507.2.9.2 or FBC Residential R905.2.8.2. Installation shall be in accordance with the manufacturer's instructions before applying shingles. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (414) 248-6409;,Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report 3m-TAM-20-FBCER.A-RO 28-119 TAMKO Roof Underlayments FL12 Revision 0: 09/29/2020/2020 Page 5 of 5