HomeMy WebLinkAboutAPPROVED-UNDERLAYMENTPRODAPPR2/10/2021 Florida Building Code Online
BCIS Home 1 Log In I User Registration I Hot Topics I Submit Surcharge
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
=lorida Engineer or Architect Name who developed the
valuation Report
=lorida License
2uality Assurance Entity
duality Assurance Contract Expiration Date
/alidated By
:ertificate of Independence
referenced Standard and Year (of Standard)
FL12328-R9
Revision
2020
Approved
TAMKO Building Products LLC
PO Box 97
Galena, KS 66739
(417)624-6644 Ext2305
kerri—eden@tamko.com
Kerri Eden
kerri—eden@tamko.com
Kerri Eden
PO Box 1404
Joplin, MO 64802
(417)624-6644 Ext2305
kerri_eden@tamko.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Archii
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/18/2021
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL12328 R9 COI 2020 01 COI NIEMINEN pdf
Standard
ASTM D1970
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 1/3
2/10/2021
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
ASTM D226
ASTM D6380
Method 1 Option D
09/29/2020
10/04/2020
10/12/2020
12/15/2020
FL # Model, Number or Name Description
12328.1 TAMKO Roof Roof underlayments for use in FBC HVHZ jurisdictions.
Underlayments (HVHZ)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL12328 R9 II 2020 09 229 FINAL ER TAMKO UNDERL
Approved for use outside HVHZ: No R9 pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See ER Section 5 for Limits of Use. Evaluation Reports
FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDER
R, p_-df
12328.2 TAMKO Roof Roof underlayments for use in FBC non-HVHZ jurisdictions
Underlayments (NON-
HVHZ)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL12328 R9 II 2020 09 29 FINAL ER TAMKO UNDERL
Approved for use outside HVHZ: Yes HVHZ FL12328-R9 p fJff
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See ER Section 5 for Limits of Use. Evaluation Reports
FL12328 R9 AE 2020 09 29 FINAL ER TAMKO UNDER
HVHZ FL12328-R9 pdf
Created by Independent Third Party: Yes
.Bach Nix
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 done: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility St
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please cor
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I
if they have one. The emails provided may be used for official communication with the licensee. However email addresses are
to supply a personal address, please provide the Department with an email address which can be made available to the pL
licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
M W] NOW eCheck
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 2/3
2/10/2021
Florida Building Code Online
Credit Card
Safe
hops://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtF2AezuarjgOlAramDGm5elxgFDzaRb4t427TWXal7Bg%3d%3d 3/3
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER
EVALUATE TEST CONSULT
REPORTEVALUATION
TAMKO Building Products, LLC Evaluation Report 3m-TAM-20-FBCER.A-RO
PO Box 97
Galena, KS 66739
(417) 624-6644
FL12328-R9
Date of Issuance: 09/29/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: TAMKO Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANEl983
tillLtf(fJ-J,J ""
t •h'
The facsimile seal appearing was authorized by Robert
°°Fs"•"wyy
Nieminen, P.E. on 09/29/2020. This does not
serve as an
CERTIFICATION OF INDEPENDENCE: e ectronically signed document.
I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019, NEMO ETC, LLC
ROOFING COMPONENT EVALUATION
F4,'
4.1
4.2
4.3
4.4
4.5
4.6
4.7
ONEMOletc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TAMKO Roof Underlayments, as produced by TAMKO Building Products LLC, have
demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
Section
Property
Standard
Year
1507.1.1 / R905.1.1
Material standard
ASTM D226
2009
1507.1.1, 1507.2.4, 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.2.9.2, 1507.6.5 / R905.2.8.2,
Material standard
ASTM D6380
2013
R905.5.4
Entity
Examination
Reference
Date
PRI(TST5878)
ASTM D1970
TAP-388-02-01
10/04/2017
PRI(TST5878)
ASTM D226,Type 11
TAP-420-02-01
04/19/2018
PRI(TSTS878)
ASTM D1970
TAP-447-02-01
10/19/2018
PRI(TST5878)
ASTM D6380
847T0009
12/21/2019
PRI(TST5878)
ASTM D6380
847T00010
12/21/2019
PRI(TST5878)
ASTM D226,Type 11
TAP-351-02-01
04/25/2016
PRI(TST5878)
ASTM D226,Type 11
TAP-351-02-02
05/04/2016
UL LLC (TST9628)
ASTM D226, Type 11
13CA12269
03/14/2014
UL LLC (QUA9625)
Quality Assurance
Service Confirmation
10/20/2020
UL LLC (QUA9625)
Quality Assurance
Florida BCIS
r....
PRODUCT DESCRIPTION'
Product
Material Standard
Plant(s)
Description
No. 30 UL
ASTM D226, Type II
Joplin, MO
Asphalt -saturated organic felt
Green Cove Springs, FL
No. 30 ASTM
ASTM D226, Type II
Phillipsburg, KS
Asphalt -saturated organic felt
TAM -FELT°
ASTM D226, Type II
Green Cove Springs, FL
Asphalt -saturated organic felt
Moisture Guard®
ASTM D1970
Joplin, MO
Self -adhering, fiberglass reinforced SBS
modified bitumen roof underlayment with a
mineral top surface.
Self -adhering, SBS modified bitumen roof
TW Underlayment
ASTM D19701
Columbus, KS
underlayment with a polymer -film top
surface.
Self -adhering, SBS modified bitumen deck
TW Seam Tape
ASTM D1970
Columbus, KS
ASTM Slate Surfaced Roll
ASTM D6380,
Green Cove Springs, FL
seam -tape with a polymer -film top surface.
Asphalt -saturated organic mat, coated
Roofing
Class M, Type II
on
both sides with asphalt and surfaced with
granules.
I Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance of TW
Underlayment.
NEMO ETC, LLC
Certificate ofAuthorization #32455 Evaluation Report 3m-TAM-20-FBCER.A-R0
7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL12328-R9
TAMKO Roof Underlayments Revision 0: 09/29/2020
Page 2 of 5
4.8
(N7)
KIrILA IN 1
Product
Material Standard
Plant(s)
IYCIVIU I C1.1..
Description
ASTM Tile Underlayment
ASTM D6380,
Green Cove Springs, FL
Asphalt -saturated organic felt, coated on
Class M, Type II
both sides with asphalt and surfaced with
granules.
5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade
Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 TAMKO Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile
Underlayment
fShingles
(15OZ3)
Metal
Slate or
Slate -Type
wood
Mechanical
Adhesive-
Panels
Shingles
Shingles
Shingles
Shakes
Attach
Set
(15OZ4)
(1507.5)
(150Z7)
(25OZ8)
(1507.9)
No. 30 UL
Yes
Yes
Yes
See 5.6.1
See 5.6.1
Yes
Yes
Yes
Yes
Yes
No. 30 ASTM
Yes
Yes
Yes
See 5.6.1
See 5.6.1
Yes
Yes
Yes
Yes
Yes
TAM-FELT00
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Moisture Guard®
Yes
No
No
Yes
Yes
No
No
Yes
(jointstrips,
(jointstrips,
1507.1.1.3 /
1507.1.1.3 /
R905.1.1.3)
R905.1.1.3)
Yes
Yes
TW Underlayment
Yes
No
No
Yes
Yes
Yes
(jointstrips,
(jointstrips,
1507.1.1.3 /
R905.1.1.3) I
1507.1.1.3 /
R905.1.1.3)
Yes
Yes
(jointstrips,
Yes
Yes
TW Seam Tape
(jointstrips,
NO
NO
Yes
Dint strips,
it P
Yes
Qoint strips,
1507.1.1.1/
R905.1.1.1)
1507.1.1.1 /
1507.1.1.1 /
1507.1.1.1 /
(jointstrips,
1507.1.1.3 /
(jointstrips,
1507.1.1.3 /
ASTM Slate Surfaced Roll
R905.1.1.1)
R905.1.1.1)
R905.1.1.1)
11905.1.1.3)
R905.1.1.3)
Yes
Yes
Roofing
(Valley Liner)
(Cap Sheet in 2-
No
No
No
No
No
No
Ply system)
ASTM Tile Underlayment Yes
Yes
(Valley Liner)
(cap Sheet in 2-
No
NO
NO
NO
No
No
ply system)
NEMO ETC, LLC
Certificate ofAuthorizotion #32455 Evaluation Report 3m-TAM-20-FBCER.A-RO
7TR EDITION (2020) FBC NON-HVHZ EVALUATION FL12328-R9
TAMKO Roof Underlayments Revision 0: 09/29/2020
Page 3 of 5
ONEMOletc.
5.6.1 No. 30 UL or No. 30 ASTM may be used as a mechanically attached anchor sheet followed by an asphalt -applied
ASTM Slate Surfaced Roll Roofing or ASTM Tile Underlayment.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Primer Substrates
Moisture Guard® or TW Underlayment self -adhering (Optional) ASTM D41 plywood
None No. 30 UL, No. 30 ASTM or TAM -FELT®
TW Seam Tape self -adhering (Optional) ASTM D41 plywood
ASTM Slate Surfaced Roll Roofing or
ASTM Tile Underlayment hot asphalt None No. 30 UL, No. 30 ASTM or TAM -FELT®
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less
than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions,
but — for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table
1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover
Installation Type Maximum Exposure (days)*
No. 30 UL, No. 30 ASTM, TAM -FELT ®
Moisture Guard®, TW Underlayment, TW Seam Tape Any 30
ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment
*Maximum exposure shall not exceed the manufacturer's recommendations, which may be less than 30 days.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the tile
shall be staged atop battens during loading of the roof tiles.
6.1 TAMKO Roof Underlayments shall be installed in accordance with TAMKO Building Products LLC installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 No. 30 UL, No. 30 ASTM:
6.3.1 Non -Tile Applications•
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
NEMO ETC, LLC
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report 3m-TAM-20-FBCER.A-RO
328-119
TAMKO Roof Underlayments FL
Revision 0: 09/2 29/2020/2020
Page 4 of 5
6.3.2 Tile Applications:
MEMO I etc.
No. 30 UL or No. 30 ASTM are limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from
FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by ASTM Slate
Surfaced Roll Roofing, ASTM Tile Underlayment applied in hot asphalt, or other FBC Approved hot -asphalt applied
cap sheet. Refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 for attachment requirements.
6.4 TAM -FELT®:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.5 Moisture Guard®, TW Underlayment:
6.5.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.6 ASTM Slate Surfaced Roll Roofing, ASTM Tile Underlayment:
6.6.1 Tile Applications:
ASTM Slate Surfaced Roll Roofing and ASTM Tile Underlayment are limited to use as the Hot Asphalt applied "Cap
Sheet" in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,
Sixth Edition.
Refer to Section 5.8.2 for attachment limitations.
Refer to Section 5.10 for the staging limitations.
6.6.2 Valley Liner:
ASTM Slate Surfaced Roll Roofing and ASTM Tile Underlayment are acceptable for use as a valley liner in accordance
with FBC 1507.2.9.2 or FBC Residential R905.2.8.2. Installation shall be in accordance with the manufacturer's
instructions before applying shingles.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (414) 248-6409;,Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report 3m-TAM-20-FBCER.A-RO
28-119
TAMKO Roof Underlayments FL12 Revision 0: 09/29/2020/2020
Page 5 of 5