Loading...
HomeMy WebLinkAboutCooling Packet ( rOo l l Right-Suite(g) Universal 201 Job: Revels rail -- aZy 2 wrightsoft° 9 RECEIVED Date: Jun 2s,2019 System 1 By: Plan: Revels JUN 26 2019 1. I-ucie County, Permittin Project Information For: Roderick Waller,Sunrise City CHDO 130 South Indian River Drive#202,Ft Pierce,FL Htg Clg Htg Clg Outside db (OF) 41 89 Inside db (OF) 70 75 Outside RH (%) - 58 Inside RH (%) - 50 Outside wb (OF) - 77 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 29 14 Moisture dill. (grub) - 57 Heating Equipment Cooling Equipment Make Make Model Model Type Gas furnace Type SplitAC Efficiency 80AFUE COP/EER/SEER 0 Heating Input 0 MBtuh Sensible 0 MBtuh Heating Output 0 MBtuh Latentcl l 0 MBtuh Humidifier 16.0 gpd To 0 MBtuh LeavingAirTemp 70.0 OF L emp 55.0 OF Actual Heating Fan 1600 cfm Cooling Fan 1600 cIm Equipment Location System 1 System Type PEAKCV Fan Motor Heat Type PACKAGE Fan&Motor Combined fficiency 0 % Static Pressure Across Fan 0 in H2O NAME Area Heat Sensible Latent Htg Clg Time fF Loss Gain Gain cfm cfm Rooml 100 815 1789 314 69 100 Aug 1700 LDT Room2 163 7359 6132 2793 557 328 Aug 1700 LDT Room3 137 868 2694 761 70 - 145 Aug 1700 LDT Room4 180 1027 2703 590 81 146 Aug 1700 LDT cst 25 27 0 0 0 0 Aug 1700 LDT closet 34 37 0 0 0 0 Aug 1700 LDT Lounge 791 16972 18058 9288 773 827 Aug 1700 LDT Bath 1 71 602 1003 225 51 54 Aug 1700 LDT System 1 1500 27708 32378 13971 1600 1600 Aug 1700 LDT REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 2019-.kin-251743:40 WrighY501FC` Right-SuiteeUniversal 201919.0.08 RSU16998 F'LE Co Page 1 Projectl.rup Calc=RTS Front Door faces:NE Py wrightsoft9 Right-Suite® Universal 2019 Short Form Date: Revels ,2019 System 2 By: Plan: Revels Project Inf• • For. Roderick Waller,Sunrise City CHDO 130 South Indian River Drive#202,Ft.Pierce,FL Mg Clg Htg Clg Outside db (OF) 41 89 Inside db (OF) 70 75 Outside RH N - 58 Inside RH N - 50 Outside wb (OF) - 77 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 29 14 Moisture diff. (grAb) - 57 Heating Equipment Cooling Equipment Make Make Model Model Type Gas furnace Type SplitAC Efficiency 80AFUE COP/EER/SEER 0 Heating Input 0 MBtuh Sensible Cooling 0 MBtuh Heating Output 0 MBtuh Latent Cooling 0 MBtuh Humidifier 15.3 gpd Total Cooling 0 MBtuh LeavingAirTemp 70.0 OF Leaving Air Temp 55.0 OF Actual Heating Fan 1600 cfm Actual Cooling Fan 1600 cfm Equipment Location System 2 System Type PEAKCV Fan Motor Heat Type PACKAGE Fan&Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME Area Heat Sensible Latent Htg Clg Time ft2 Loss Gain Gain cfm c(m Hall 1 155 996 2138 489 79 114 Aug 1700 LDT Bath 2 72 522 927 226 42 49 Aug 1700 LDT utility 48 488 756 151 41 40 Aug 1700 LDT Hall 2 203 7852 5172 2920 588 310 Aug 1700 LDT Room13 145 2135 3343 1809 40 146 Aug 1700 LDT Room14 152 2225 3327 1873 42 144 Aug 1700 LDT Room15 270 3361 5236 2364 74 231 Aug 1700 LDT Hall 3 455 9239 10575 3714 694 564 Aug 1700 LDT System 2 1500 26817 31472 13546 1600 1600 Aug 1700 LDT 2019-Jun-2517:43:40 wrightsoft' Pight-Suite®Universal 2019 19.0.08 RSU16998 Page 2 Projectt.rup Calc=RTS Front Door faoes:NE Right-Suite®Universal 2019 Load Summary Job: Revels - - wrightsoft, Date: Jun 25,2019 System 1 By: Plan: Revels Project Information For. Roderick Waller,Sunrise City CHDO 130 South Indian River Drive#202,Ft Pierce,FL Zone: System 1 COOLING LOAD 1. DESIGN CONDITIONS atAug 1700 LDT Peak load atAug 1700 LDT Inside: 75 OF Outside: 89 OF TD: 14 OF RH: 58 % MoistDiffi 56.9 grflb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 2792 - 3. TRANSMISSION GAINS Sensible 5601 Walls: 1434 - - Glass: 726 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 3442 - - 4. INTERNAL HEAT GAIN Sensible Latent 16640 1500 Occupants: 1423 1500 - - Lights: 10983 - - - Motors: 0 - - - Appliances: 4234 0 - - 5. INFILTRATION: Outside air cfm: 161 2556 6203 6. SUBTOTAL: Space load Sensible Latent 27589 7703 Envelope 27589 7703 - - Less external 0 - -Redistribution 0 0 - - 7. SUPPLY DUCT 1379 - 8. SUBTOTAL: Space load+supply dud 28968 Actual dm: 1600 at supply TD: 20 - - 9. VENTILATION: Make-up aircfm: 162 2583 6268 10. RETURN AIR LOAD: Lighting+plenum(net) 0 - 11. RETURN DUCT 828 - 12. TOTALLOADS ON EQUIPMENT 32378 13971 HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 4519 Walls: 1112 - Glass: 1544 - Doors: 0 - Partitions: 0 - Floors: 376 - Ceilings: 1487 - 15. INFILTRATION: Outside air t fm: 337 10753 16. SUBTOTAL: Space load 15271 Envelope 15271 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 764 18. VENTILATION: Make-up air tfrn: 162 5170 19. HUMIDIFICATION 6045 Piping 0 20. RETURN DUCT 458 21. TOTALHEATING LOAD ON EQUIPMENT 27708 -4d- wrightsoft- 2019-Jun-2517:43:40 �.• .a lPoght-Suile®Universal 201919.0.08 RSU16998 Page 1 Projectl.rup Calc=RTS Front Door faces:NE Right-Suite®Universal 2019 Load Summary Job: Revels wrightsoftp Date: Jun 25,2019 System 2 By: Plan: Revels Project Inf• • For. Roderick Waller,Sunrise City CHDO 130 South Indian River Drive#202,Ft Pierce,FL Zone: System 2 COOLING LOAD 1. DESIGN CONDITIONS atAug 1700 LDT Peak load atAug 1700 LDT Inside: 75 OF Outside: 89 OF TD: 14 OF RH: 58 % MoistDiff: 56.9 grAb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 2762 - 3. TRANSMISSION GAINS Sensible 5601 Walls: 1433 - - Glass: 724 - - Doors: 0 - - Partitions: 0 - - Floors: 0 - - Ceilings: 3445 - - 4. INTERNAL HEAT GAIN Sensible Latent 16072 1750 Occupants: 1657 1750 - - Lights: 10914 - -Motors: 0 - - - Appliances: 3501 0 - - 5. INFILTRATION: Outside air cim: 174 2770 6723 6. SUBTOTAL: Space load Sensible Latent 27206 8473 Envelope 27206 8473 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 1360 - 8. SUBTOTAL: Space load+supply duct 28566 - Actual cim: 1600 at supply TD: 20 - - 9. VENTILATION: Make-up aircfm: 131 2090 5073 10. RETURN AIR LOAD: Lighting+plenum(net) 0 - 11. RETURN DUCT 816 - 12. TOTAL LOADS ON EQUIPMENT 31472 13546 HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 4519 Walls: 1112 - Glass: 1544 - Doors: 0 - Partitions: 0 - Floors: 376 - Ceilings: 1487 - 15. INFILTRATION: Outside air ch: 347 11074 16. SUBTOTAL: Space load 15593 Envelope 15593 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 780 18. VENTILATION: Make-up air cfin: 131 4184 19. HUMIDIFICATION 5793 Piping 0 20. RETURN DUCT 468 21. TOTALHEATING LOAD ON EQUIPMENT 26817 'F�F wrightsoft- 2019-Jun-2517:43:40 Right-Suite®Uniwrsal 201919.0.08 RSU16998 Page 2 Projectl.rup C•Ic=RTS Front Door faces:NE Sheet 1 Hall 3 ij M00 drn ®27m2 278 dr» 173 dm z 173 dm li I 116 dm i 116 dm m 146 dm i �� Room15 i! 173 dm Room4 i t closet N 73&n I - 207 d 1600 c5n m —- -------------- + Existing ® El l Existing III i ,; RQamJA I' �1 196 dm ! is f ®207dm Lounge �207dm� i Hall RQ�nr}�346 dm j IIL(VI � 196 dm I z i I i ` Hall 2 N9 dm Bath 2 207 dm utility -�I�}Jh�/1I�,, ®I14 itin IG�^Cfm --- t - 41 dm i l Job M Revels Scale: 1 : 118 Performed for: Page 1 Roderick Weiler Right-Suite®Universal2019 130 South Indian River Drive#202 19.0.08 RSU16998 Ft.Pierce,FL 2019-Jun-25 17:44:21 Project1.rup