HomeMy WebLinkAboutRevision20-0029 BASE_Main Bldg_Permit Set_R2_10-20-2021 E_SIGN FOUNDATION PLAN SCALE: 1/8" = 1'-0" +/-PSF WIND DESIGN PRESSURES (POUNDS PER SQUARE FOOT) 1 2 3 4 5 6 A E D C B A E D C B 25'-0" 32/-34 32/-34 P-1 TE-1 TE-1 P-1 TE-1 TE-1 P-1P-1 TE-1 P-3 TE-1TE-1TE-1TE-1P-2 P-2 P-2 P-3TE-1 P-1 P-1 P-1 P-1 TE-1TE-1TE-1TE-1P-3 P-2 P-2 P-2 P-3 TE-1TE-1TE-1TE-125'-0"25'-0"25'-0"25'-0" 5'-4 1/2"19'-7 1/2" 125'-0" 25'-0"25'-0"25'-0"25'-0"25'-0" 20'-4"4'-8" 125'-0"20'-0"80'-0"20'-0"20'-0"20'-0"80'-0"20'-0"20'-0"20'-0"6" MIN. THICK (F'c = 4,000 PSI) CONCRETE SLAB ON GRADE, REINF. W/ 6x6 - W2.9 x W2.9 WWF ON 6 MIL VAPOR BARRIER ON TREATED, WELL COMPACTED SOIL 1 2 3 4 5 610'-0"5'-11 1/2"14'-0 1/2"32/-4210'-3"1'-4"9'-9"10'-0"20'-0"6'-1 1/2"1'-3"1'-3"11 1/2" 25/-28 10'-0"15'-0" 2'-4"22'-8" F-1 F-1 F-1 F-1 F-1 400S162-54 VERTICAL CFS STUDS @ 16" O.C. MAX.; METAL STUD INTERIOR BEARING WALLS.1'-4"13'-10 1/2"32/-41FDFD 400S162-54 VERTICAL CFS STUDS @ 16" O.C. MAX.; METAL STUD INTERIOR NON-BEARING WALLS. 32/-34 30/-3832/-4132/-4132/-42S2 1 TYP. S2 2 TYP. S2 3 S2 4 48" HIGH CMU KNEEWALL REINFORCED W/ #5 VERT. REBAR @ 48" O.C. MAX. SPACING AND AT EACH END OF WALL; TYP. 48" HIGH CMU KNEEWALL REINF. W/ #5 VERT. REBAR SPACED @ 4FT O.C. MAX.; & AT ENDS OF WALL. 400S162-54 VERTICAL CFS STUDS @ 12" O.C. MAX.; METAL STUD INTERIOR BEARING WALLS. PREFABRICATED METAL BUILDING; SEE METAL BUILDING MFG.'S PLANS, SECTIONS AND DETAILS. S2 5 1200S162-68 VERTICAL CFS STUDS @ 16" O.C. MAX.; METAL STUD INTERIOR NON-BEARING WALLS. FOUNDATION SCHEDULE MARK TE-1 W x D x L 16" x 16" x CONT. REINFORCEMENT NOTES THICKENED EDGE FOOTER(2) #5 CONT. P-1 ANCHOR BOLTS (F1554 GRADE 36 HEX HEAD BOLT) 50" x 16" x 63"(5) #5 E.W. T&B RIGID FRAME FOOTERS 8" EMBED. MIN. P-2 38" x 16" x 48"(4) #5 E.W. T&B RIGID FRAME FOOTERS 8" EMBED. MIN. P-3 44" x 16" x 44"(3) #5 E.W. T&B RIGID FRAME CORNER FOOTERS 8" EMBED. MIN. F-1 16" x 16" x CONT.BELL FOOTER(2) #5 CONT. STRUCTURAL-GENERAL NOTES DESIGN CRITERIA AND LOADS 1.WIND DESIGN: WIND SPEED (MPH) V(ADJ)=124 V(ULT)=160 RISK CATEGORY II EXPOSURE CATEGORY C ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT CPI =+/- 0.18 TOPOGRAPHIC FACTOR KZT =1.0 2.DESIGN LIVE LOADS: a. ROOF LIVE LOAD 20 PSF b. ATTIC SPACE WITH STORAGE LIVE LOAD 20 PSF 3.DESIGN DEAD LOADS: a. METAL BLDG. ROOF DEAD LOAD, TOTAL PER M.B.M. b. SHOWRM / OFFICE / LAB / RESTRM / BREAKRM ROOF, TOTAL 15 PSF 4.THE CONTRACTOR HAS THE RESPONSIBILITY TO NOTIFY THE SER OF ANY ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING LOAD IMPOSED ONTO THE STRUCTURE THAT DIFFERS FROM, OR THAT IS NOT DOCUMENTED ON THE ORIGINAL CONTRACT DOCUMENTS (ARCHITECTURAL/ STRUCTURAL/ MECHANICAL/ ELECTRICAL OR PLUMBING DRAWINGS). PROVIDE DOCUMENTATION OF LOCATION, LOAD, SIZE AND ANCHORAGE OF ALL UNDOCUMENTED LOADS IN EXCESS OF 400 POUNDS. PROVIDE MARKED-UP STRUCTURAL PLAN INDICATING LOCATIONS OF ANY NEW EQUIPMENT OR LOADS. SUBMIT PLANS TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO INSTALLATION. 5.LOADS ON THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE DESIGN LOADS AS NOTED IN DESIGN CRITERIA & LOADS BELOW OR THE CAPACITY OF PARTIALLY COMPLETED CONSTRUCTION AS DETERMINED BY THE CONTRACTOR'S SSE FOR BRACING/SHORING. GENERAL REQUIREMENTS 1.THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE "FLORIDA BUILDING CODE (FBC)", SIXTH EDITION, HEREAFTER REFERRED TO AS THE FBC, AS ADOPTED AND MODIFIED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 2.WHERE OTHER STANDARDS ARE NOTED IN THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD. 3.REFER TO THE ARCH'L, CIVIL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADD'L INFORMATION INCLUDING BUT NOT LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, NON-BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING, RAILINGS, CURTAIN WALLS, DEPRESSIONS, MECHANICAL UNIT LOCATIONS, & OTHER NONSTRUCTURAL ITEMS. 4.THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND DOSH (DEPARTMENT OF OCCUPATIONAL SAFETY AND HEALTH). AB - ANCHOR BOLT AFF - ABOVE FINISHED FLOOR AHJ - AUTHORITY HAVING JURISDICTION ALT - ALTERNATE APPROX - APPROXIMATELY ARCH - ARCHITECT BOTT - BOTTOM BRG - BEARING CCCL - COASTAL CONST. CONTROL LINE CFS - COLD FORMED STEEL CMU - CONCRETE MASONRY UNIT COL - COLUMN CONC - CONCRETE CONT - CONTINUOUS D&E - DRILLED AND EPOXY DBL - DOUBLE DIA - DIAMETER DIM - DIMENSION DN - DOWN EA - EACH ELEV - ELEVATION/ELEVATOR ENGR - ENGINEER EW - EACH WAY E - EXISTING EXP - EXPANSION EXT - EXTERIOR FBC - FLORIDA BUILDING CODE FF - FINISH FLOOR FND - FOUNDATION FT - FEET/FOOT FTG - FOOTING ABBREVIATIONS HORIZ - HORIZONTAL IN - INCH/INCHES INT - INTERIOR MAS - MASONRY MAX - MAXIMUM MFR - MANUFACTURER MIN - MINIMUM MISC - MISCELLANEOUS MPH - MILES PER HOUR N - NEW NTS - NOT TO SCALE OC - ON CENTER PSF - POUNDS PER SQUARE FOOT PT - PRESSURE TREATED REV - REVISION/REVISED SPECS - SPECIFICATIONS SCHED - SCHEDULE SYP - SOUTHERN YELLOW PINE TYP - TYPICAL UNO - UNLESS NOTED OTHERWISE VERT - VERTICAL VIF - VERIFY IN FIELD W/- WITH W/O - WITHOUT WRB -WEATHER RESISTANT BARRIER WWF - WELDED WIRE FABRIC WWM - WELDED WIRE MESH #5 - STEEL REINFORCING BAR (REBAR) #5 (5/8") 37.ALL REINFORCING BARS MARKED "CONTINUOUS" SHALL BE LAPPED 36 DIA. AT SPLICES AND CORNERS UNLESS OTHERWISE NOTED. LAP CONTINUOUS TOP BARS AT CENTER BETWEEN SUPPORTS AS REQUIRED. TERMINATE CONTINUOUS BARS AT NON-CONTINUOUS ENDS WITH STANDARD HOOKS. U.O.N. 38.ALL WALLS (OTHER THAN SHEARWALLS) AND COLUMNS SHALL BE DOWELED INTO FOOTINGS, WALLS, BEAMS, OR SLABS WITH BARS OF THE SAME SIZE AND SPACING AS THE BARS ABOVE. USE A (30) BAR DIAMETER LAP EXCEPT WHERE SPECIFICALLY INDICATED. FOR SHEARWALL VERTICAL REINFORCING USE CLASS A TENSION SPLICE LENGTHS. 39.VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. SPLICE BARS IN WALLS, BEAMS, GRADE BEAMS ETC., (UNLESS OTHERWISE NOTED) AS FOLLOWS: TOP BARS AT CENTER LINE OF SPAN, BOTTOM BARS AT THE SUPPORT. 40.THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR SAFE ADEQUATE SHORING, RE -SHORING, BRACING AND FORMWORK. GENERAL CONTRACTOR SHALL CONTRACT A STATE OF FLORIDA REGISTERED ENGINEER TO PREPARE SHORING AND RE-SHORING PLANS TO BE SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL. 41.THE LONGITUDINAL REINFORCING STEEL IN BOND BEAMS, WALLS AND FOOTINGS SHALL BE CONTINUOUS AROUND CORNERS. SEE TYPICAL DETAILS. 42.CONCRETE LAP SPLICE, FOR LAP SPLICE LENGTHS, IN NO CASE SHALL BE LESS THAN 24 INCHES. STEEL STUDS 1.ALL PRODUCTS TO BE MANUFACTURED BY THE CURRENT MEMBERS OF THE STEEL STUD MANUFACTURERS ASSOCIATION. 1.ALL GALVANIZED STUDS AND JOISTS SHALL BE FORMED FROM STEEL THAT CORRESPONDS TO THE MINIMUM REQUIREMENTS OF 1996 AISI STANDARDS. 2.ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) “SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS”. 3.PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO, TRACKS, CLIPS. WEB STIFFENERS, ANCHORS, FASTENING DEVICES, RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE STEEL MEMBERS USED. 4.FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING. SCREWS OR WELDS SHALL BE OF SUFFICIENT SIZE TO ENSURE THE STRENGTH OF THE CONNECTION. ALL WELDS OF CARBON SHEET STEEL SHALL BE TOUCHED UP WITH PAINT. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITTED. 5.STUDS SHALL ADHERE TO ASTM A 653/653 M STEEL, [G60 (Z180)] GALVANIZED , CHANNEL SHAPED WITH LIPPED FLANGES, PUNCHED WEB, SIZE, THICKNESS AND GRADE AS SHOWN ON DRAWINGS. 6.TRACKS SHALL ADHERE TO ASTM A 653/653 M STEEL, SAME DESIGNATION, COATING, AND THICKNESS AS STUDS EXCEPT AS OTHERWISE NOTED, CHANNEL SHAPED, SOLID WEB, DEPTH COMPATIBLE WITH STUDS, SIZE, THICKNESS AND GRADE AS SHOWN ON DRAWINGS. 7.INSTALL COLD-FORMED METAL FRAMING PLUMB, SQUARE, TRUE TO LINE AND SECURELY FASTENED AS SHOWN ON DRAWINGS. 8.CUT MEMBERS BY SHEARING OR SAWING. ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR MEMBERS OR AS REQUIRED FOR AN ANGULAR FIT AGAINST ABUTTING MEMBER. 9.INSTALL MEMBERS IN SINGLE PIECE LENGTHS EXCEPT THAT TRACKS MAY BE SPLICED, BUTT-WELDED, OR EACH LENGTH ANCHORED TO A COMMON BUILDING FRAME ELEMENT. 10.INSTALL INSULATION IN FRAMING SPACES MADE INACCESSIBLE AFTER ERECTION. 11.REPAIRS AND TOUCH-UP: CLEAN DAMAGED SURFACES & COATINGS. TOUCH-UP FIELD WELDS AND DAMAGED GALVANIZED SURFACES WITH GALVANIZING REPAIR COMPOUND. 12.TOLERANCES: a)VARIATION FROM PLUMB, LEVEL, AND TRUE TO LINE: 1/8 INCH IN 10 FEET (1:960). b)MEMBER SPACING: NOT MORE THAN 1/8 INCH (3 MM) PLUS OR MINUS FROM SPACING INDICATED. 14.FRAME CORNERS WITH THREE STUDS. 15.INSTALL ACCESSORIES AS REQUIRED. PROVIDE APPROPRIATE FASTENERS IN ALL PREDRILLED HOLES BACKED BY ANOTHER FRAMING MEMBER. 16.BRIDGING CLIP FOR COLD ROLLED CHANNEL BRIDGING: SECURE TO STUD WEB BY INSERTING TABS THROUGH WEB SLOTS AND WITH 2 SCREWS. SECURE TO CHANNEL WITH ONE SCREW. 17.FASTENERS a)SCREWS TO BE CORROSION RESISTANT COATED, SELF-DRILLING, PAN OR HEX WASHER HEAD. PROVIDE SCREW TYPE AND SIZE AS REQUIRED PER STRUCTURAL DRAWINGS, FOR THE SPECIFIC CONDITION AND THICKNESS OF MATERIALS BEING JOINED. b)ANCHOR BOLTS AND STUDS TO BE IN ACCORDANCE WITH ASTM A 307, GRADE A, CARBON STEEL, WITH HEX-HEAD CARBON STEEL NUTS AND FLAT STEEL WASHERS. HOT-DIP ZINC COATED IN ACCORDANCE WITH ASTM A 153. PROVIDE BOLT OR STUD TYPE AND SIZE AS SHOWN ON DRAWINGS. c)EXPANSION ANCHORS TO BE IN ACCORDANCE WITH FEDERAL SPECIFICATION FF-S-325, GROUP II, TYPE 4, CLASS 1. PROVIDE BOLTS LISTED OR APPROVED BY ONE OR MORE OF THE FOLLOWING AND OF DIAMETER AND LENGTH AS SHOWN ON DRAWINGS. d)POWDER ACTUATED FASTENERS TO BE IN ACCORDANCE WITH FEDERAL SPECIFICATION FF-P-395B. MANUFACTURER FROM AISI 1062 OR 1065 STEEL, AUSTEMPERED TO A MINIMUM CORE HARDNESS OF 50 TO 54 HRC AND ZINC PLATED IN ACCORDANCE WITH ASTM B 633. PROVIDE FASTENERS OF THE TYPE, DIAMETER AND LENGTH AS SHOWN ON DRAWINGS. PRE-ENGINEERED METAL BUILDING 1.THE PRE-ENGINEERED BUILDING SHALL CONSIST OF ROOF DECK, RIGID FRAMES, CANOPY FRAMING, GUTTERS, DOWNSPOUTS AND FLASHING AS REQUIRED. 2.DEVIATION FROM BAY SPACING SHOWN ON THE PLANS SHALL NOT BE PERMITTED. 3.SUBMIT TRUSS SHOP DRAWINGS SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWINGS SHALL INCLUDE LAYOUT, DESIGN LOADS, AND ALL OTHER INFORMATION REQUIRED FOR PROPER INSTALLATION. 4.THE MANUFACTURER SHALL BE REGULARLY ENGAGED IN METAL BUILDING DESIGN AND MANUFACTURING. 5.THE DESIGN SHALL BE IN ACCORDANCE WITH AISC, AISI AND MBMA (METAL BUILDING SYSTEMS MANUAL” DESIGN PRACTICES. THE TOTAL DRIFT SHALL BE LIMITED TO H/360. 6.LATERAL SUPPORT OF MASONRY WALLS AND VENEERS BY CONTINUOUS STEEL WIND GIRT SHALL BE DESIGNED AND PROVIDED BY METAL BUILDING SUPPLIER. MASONRY WALL SHALL NOT BE USED FOR LATERAL SUPPORT. 7.FOUNDATION WORK SHALL NOT COMMENCE UNTIL FINAL PRE-ENGINEERED METAL BUILDING SHOP DRAWINGS AND CALCULATIONS ARE REVIEWED AND APPROVED. FOUNDATIONS ARE SUBJECT TO CHANGE BASED ON MANUFACTURER'S FINAL DOCUMENTATION FOR CONSTRUCTION. 5.THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS. 6.PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES. 7.ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DOCUMENTATION TO THE ARCHITECT/ENGINEER FOR REVIEW. ALTERNATE MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENT OF MATERIALS SPECIFIED MAY BE RETURNED WITHOUT REVIEW. ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE REVIEWED UNLESS AUTHORIZED BY THE OWNER. 8.ALL STANDARD NOTES AND DETAILS CONTAINED HEREIN ARE TYPICAL UNLESS NOTED OTHERWISE. 9.ALL BUILDING SITES SHALL BE GRADED TO PROVIDE DRAINAGE UNDER ALL PORTIONS OF THE BUILDING & AROUND THE BUILDING PERIMETER TO ALLOW DRAINAGE AWAY FROM THE STRUCTURE. 10.SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, DIMENSIONS, ELEVATIONS, ETC. 11.SHOP DRAWINGS SHALL BE REVIEWED BY CONTRACTOR PRIOR TO SUBMITTAL TO THE ARCHITECT/ENGINEER. DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. 12.CHANGES AND ADDITIONS MADE ON RE-SUBMITTALS SHALL BE CLEARLY CLOUDED AND NOTED. ARCHITECT/ENGINEER REVIEW WILL BE LIMITED TO THOSE ITEMS CAUSING THE RE-SUBMITTAL. STRUCTURAL CERTIFICATION 1.I CERTIFY THAT THE PLANS AND SPECIFICATIONS COMPLY WITH THE STRUCTURAL PORTION OF THE FLORIDA BUILDING CODE SIXTH EDITION. 2.I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED IN SECTION 1609 IN THE FBC. FOUNDATION AND SLABS ON GRADE 1.FOUNDATION IS DESIGNED BASED ON PRESUMPTIVE SAFE ALLOWABLE BEARING PRESSURE OF 2,000 PSF. CONTRACTOR SHALL VERIFY THAT THE MINIMUM BEARING PRESSURE IS OBTAINED PRIOR TO FOOTING PLACEMENT. 2.REINFORCED FOUNDATION REQUIREMENTS USED IN THE DESIGN: a.MINIMUM DEPTH BELOW FINISHED GRADE......................1'-0" b.MAXIMUM ALLOWABLE BEARING CAPACITY.....................2,000 PSF c.MODULUS OF SUBGRADE REACTION.............................. 160 PCI d.PASSIVE LATERAL PRESSURE........................................... 250 PSF e.ACTIVE LATERAL PRESSURE (UNRESTRAINED) ............55 PSF f.ACTIVE LATERAL PRESSURE (RESTRAINED)……………35 PSF g.COEFFICIENT OF SLIDING FRICTION………………………0.4 3.ALL FOUNDATION CONCRETE SHALL BE CAST IN THE DRY. DEWATERING OPERATION SHALL BE DONE IN SUCH A WAY THAT GROUND WATER LEVELS OUTSIDE THE SITE WILL BE MAINTAINED TO AVOID SETTLEMENT AND DAMAGE TO NEARBY BUILDINGS AND STRUCTURES. 4.WELDED WIRE FABRIC SHALL CONFORM TO A.S.T.M. A185 (LATEST EDITION), AND BE SUPPORTED ON SLAB CHAIRS SPACED AT 3' -0 O.C.. MAXIMUM. 5.REMOVE AND REPLACE MINIMUM 1 FEET OF EXISTING SOIL BELOW FOUNDATION WITH COMPACTED, MOISTURE-TREATED, NON-EXPANSIVE FILL MATERIAL. FILL AREA SHALL EXTEND 1 FOOT BEYOND FOUNDATION FOOTPRINT. 6.THE FILL MATERIAL BELOW THE SLAB ON GRADE SHALL BE A DENSE-GRADED AGGREGATE THAT IS GENERALLY GRADED BETWEEN THE 11 2-INCH AND No. 4 SIEVES. THE DENSE-GRADED AGGREGATE SHOULD BE OF SIMILAR GRADATION AND MATERIAL TYPE AS LOCAL DOT-APPROVED ROAD SUBBASE STONE MATERIAL, IN ACCORDANCE WITH ACI STANDARDS AND GUIDELINES. 7.FOR SITE PREPARATION, REMOVE DELETERIOUS MATERIAL SUCH AS VEGETATION, ORGANIC SOILS AND ROOT ZONES, EXISTING FILL, OR LOOSE, SOFT FROZEN, OR OTHERWISE UNSUITABLE MATERIALS FROM BELOW THE PROPOSED FOUNDATION AREAS. 8.SUBGRADE SHALL BE UNIFORM OVER THE ENTIRE FOUNDATION AREA. DEPRESS SLABS ON GRADE FOR FLOOR FINISHES PER ARCHITECTURAL DRAWINGS. 9.FOUNDATIONS SHALL BEAR ON EITHER COMPETENT NATIVE SOIL OR COMPACTED STRUCTURAL FILL AS PER THE GEOTECHNICAL REPORT. EXTERIOR PERIMETER FOOTINGS SHALL BEAR NOT LESS THAN 24 INCHES BELOW FINISH GRADE, UNLESS OTHERWISE SPECIFIED BY THE GEOTECHNICAL ENGINEER AND/OR THE BUILDING OFFICIAL. 10.PROVIDE (2) 6 MIL 'VISQUEEN' VAPOR BARRIER UNDER ALL SLABS ON FILL (UNLESS OTHERWISE NOTED ON PLANS). 11.COLUMNS, WALLS OR ANY OTHER STRUCTURAL MEMBER PENETRATING SLABS ON FILL SHALL BE ISOLATED BY PRE-MOLDED JOINT FILLER (1/2" THICK) COMPLYING WITH ASTM D1752, TYPE 1. 12.TOPS OF FOOTINGS AND SLABS ON GRADE SHALL BE AS SHOWN ON PLANS WITH VERTICAL CHANGES AS INDICATED WITH STEPS IN THE FOOTINGS; LOCATIONS OF STEPS SHOWN AS APPROXIMATE AND SHALL BE COORDINATED WITH THE CIVIL GRADING PLANS TO ENSURE THAT THE EXTERIOR PERIMETER FOOTINGS BEAR NO LESS THAN 24 INCHES BELOW FINISH GRADE, OR AS OTHERWISE INDICATED BY THE GEOTECHNICAL ENGINEER OR BUILDING OFFICIAL. 13.NON-EXPANSIVE BACKFILL SHALL BE PLACED IN CONTROLLED LIFTS NOT TO EXCEED 12 INCHES AND SHALL BE COMPACTED TO AT LEAST 95% OF LABORATORY MAXIMUM DENSITY (ASTM D 1557). 14.AREA DRAINAGE SHALL BE DIRECTED AWAY FROM THE FOUNDATION. 15.GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR SHORING, SHEETING AND BRACING OF EXCAVATIONS. 16.GENERAL CONTRACTOR SHALL INSTALL ALL PIPE SLEEVES, BOXED OPENINGS, ANCHOR BOLTS, ETC., AS REQUIRED FOR THE VARIOUS TRADES. WALL POCKETS TO RECEIVE BEAMS AND SLABS SHALL BE PROVIDED AS REQUIRED FOR THE SUPER-STRUCTURE. SHOP DRAWINGS SHOWING THE POSITION OF OPENINGS SHALL BE SUBMITTED TO THE CONTRACTING OFFICER PRIOR TO PLACEMENT OF CONCRETE. 17.LOCATE SAWCUTS PER PLAN OR IF NOT SHOWN ON PLANS COMPLY WITH ACI 224.3. 18.IN NO CASE SHALL TRUCKS, BULLDOZERS OR OTHER HEAVY EQUIPMENT BE PERMITTED CLOSER THAN 8'-0" FROM ANY FOUNDATION WALL UNLESS APPROVED BY ENGINEER. CONCRETE 1.ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" AND ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". 2.REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A 615 GRADE 60. 3.WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 "SPECIFICATION FOR WELDED STEEL WIRE FABRIC FOR CONCRETE REINFORCEMENT, FLAT SHEETS ONLY. 4.HOOKED ANCHOR BOLTS SHALL BE IN ACCORDANCE WITH ASTM A 36. 5.HEADED MACHINE BOLTS SHALL BE IN ACCORDANCE WITH ASTM F1554. 6.ALL CONCRETE STRUCTURAL COMPONENTS SHALL HAVE CONCRETE STRENGTH TESTED IN ACCORDANCE WITH ASTM STANDARDS, FLORIDA BUILDING CODE AND ACI 318 (LATEST EDITION). TEST CYLINDERS MUST BE TAKEN EVERY 50 CUBIC YARDS OF CONCRETE PRIOR TO PLACEMENT. TESTING LAB SHALL PROVIDE COPIES OF CONCRETE TESTS RESULTS TO ENGINEER'S OFFICE FOR REVIEW. 7.THE CONCRETE STRENGTHS SHOWN IN THE FOLLOWING TABLE ARE THE MINIMUM COMPRESSIVE STRENGTHS AT 28 DAYS AND THE WATER/CEMENT RATIO IS THE MAXIMUM. THE SPECIFIED SLUMP IS THE MAXIMUM PRIOR TO THE ADDITION OF ADMIXTURES. CONCRETE SHALL BE STANDARD WEIGHT CONCRETE (145 PCF). ITEM OF STRENGTH AGG SLUMP WATER/CEMENT CONSTRUCTION (PSI) (IN) (IN) (LB/LB) FOUNDATIONS & SOG 4,000 3/4 4-6 0.45 8.FORMWORK SHALL COMPLY WITH "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK" (ACI 347R). 9.CONCRETE SHALL BE PROPORTIONED SUCH THAT 7 DAY STRENGTHS ARE A MINIMUM OF SEVENTY PERCENT OF THE SPECIFIED 28 DAY STRENGTH FOR ANY CONCRETE CONSTRUCTION REQUIRING SHORING, BRACING OR TO RECEIVE CONSTRUCTION LOADS. 10.CONCRETE ON EXPOSED SLABS, BEAMS AND STAIRS SHALL HAVE THE TOP SURFACE COATED WITH "ALKYL-ALKYOXY SILANE SEALER" OR ENGINEER-APPROVED EQUAL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 11.TRANSPORTATION, PLACING, AND CURING OF CONCRETE SHALL COMPLY WITH ACI 318 BUILDING CODE (LATEST EDITION). DO NOT USE SILICATE BASED SURFACE DENSIFIER FOR CURING. 12.ALL CONCRETE EXPOSED TO WEATHER SHALL BE DESIGNED WITH A CORROSION INHIBITOR. 13.ALL CONCRETE SHALL CONTAIN AN ENGINEER-APPROVED ASTM C494 TYPE 'D' ADMIXTURE (WATER-REDUCING RETARDER). USE OF FLY ASH IS PERMITTED. 14.REINFORCING STEEL SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE. 15.ALL ACCESSORIES SHALL HAVE UPTURNED LEGS, AND BE PLASTIC DIPPED AFTER FABRICATION. ACCESSORIES FOR REINFORCING SHALL BE INSTALLED IN ACCORDANCE WITH ACI 315 CURRENT EDITION. 16.ALL REINFORCING SHALL BE DETAILED & FABRICATED FOLLOWING THE REQUIREMENTS OF ACI 315. 17.WELDED WIRE FABRIC SHALL BE SUPPORTED ON SLAB BOLSTERS. USE FLAT SHEETS ONLY. 18.REINFORCEMENT SHOP DRAWINGS, FABRICATION AND PLACING SHALL CONFORM TO ACI 315, ACI 318 AND ACI SP66. 19.COMPLETE SHOP DRAWINGS FOR FABRICATION AND PLACING OF REINFORCING STEEL SHALL BE SUBMITTED FOR APPROVAL. NO FABRICATION MAY BEGIN UNTIL DRAWINGS ARE COMPLETED AND APPROVED. 20.LAP SPLICES FOR REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 318. ALL UNSPECIFIED LAP SPLICES SHALL BE MAXIMUM LENGTH. 21.WELDING OF REINFORCING STEEL SHALL BE DONE IN STRICT ACCORDANCE WITH THE AMERICAN WELDING SOCIETY "REINFORCING STEEL WELDING CODE", A.W.S. D1.4. PREHEATING OF REINFORCING SHALL BE BASED ON THE CARBON EQUIVALENT DETERMINED FROM REINFORCING MILL REPORTS. GRADE 40 REINFORCING SHALL BE WELDED WITH E7018 LOW HYDROGEN ELECTRODES, AND GRADE 60 REINFORCING SHALL BE WELDED WITH E9018 LOW HYDROGEN ELECTRODES. 22.EXPOSED REINFORCEMENT, INSERTS AND PLATES INTENDED FOR BONDING WITH FUTURE EXTENSIONS SHALL BE PROTECTED FROM CORROSION. 23.CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS: a.NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: ROOF SLAB 1” STRUCTURAL SLABS AND WALLS 3/4” BEAMS AND COLUMNS (PRIMARY REINFORCEMENT, TIES, STIRRUPS AND SPIRALS) 1 1/2” 25.NO WATER SHALL BE ADDED TO THE CONCRETE AT THE JOB SITE. 26.CONCRETE BEAMS CAST OVER MASONRY WALLS SHALL BE POURED AFTER THE BLOCK WALLS BELOW ARE IN PLACE. REINFORCING SHALL BE CONTINUOUS THROUGH BEAM WITH MINIMUM LAP SPLICES OF 48 BAR DIAMETERS AND BENT BARS AT CORNERS. USE METAL LATH, MORTAR OR SPECIAL UNITS TO CONFINE CONCRETE TO AREA REQUIRED, IN ACCORDANCE WITH ACI 530.1 (SOLID METAL OR FELT CAVITY CAPS ARE PROHIBITED) 27.REMOVE ALL DEBRIS FROM FORMS AND FLOOR DECK BEFORE POURING. 28.ALL CONCRETE PLACED SHALL BE VIBRATED BY MECHANICAL VIBRATORS. 29.CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN WALLS AND COLUMNS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. USE HOPPERS, CHUTES OR TRUNKS OF VARYING LENGTHS SO THAT THE FREE UNCONFINED FALL OF CONCRETE SHALL NOT EXCEED 5 FEET, AND A SUFFICIENT NUMBER SHALL BE USED TO ENSURE THE CONCRETE IS BEING KEPT LEVEL AT ALL TIMES. 30.ALL PLACEMENT OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE OF THE CONCRETE REINFORCING STEEL INSTITUTE. 31.SUPPORT BARS SHALL BE #5 OR GREATER, & NOT SPACED MORE THAN 4' -0" 0/C. SUPPORT BARS AND ENDS OF MAIN REINFORCING SHALL NOT EXTEND MORE THAN 1' -6" PAST OUTERMOST CHAIR OR SUPPORT BAR. 32.A MINIMUM OF 3 SUPPORT BARS & 3 INDIVIDUAL HIGH CHAIRS FOR EACH SUPPORT BAR SHALL BE PROVIDED FOR TOP REINFORCING. 33.PLASTIC TIPPED COLUMN SPACERS SHALL BE PROVIDED FOR VERTICAL COLUMN REINFORCING STEEL, SUCH THAT A 2" MINIMUM CLEARANCE IS MAINTAINED. 34.NO DEVIATION FROM THE STRUCTURAL PLANS SHALL BE PERMITTED WITHOUT THE EXPRESS WRITTEN CONSENT OF THE STRUCTURAL ENGINEER. ALL REINFORCING DETAILS TO BE SUBMITTED TO THE CONTRACTING OFFICER FOR HIS APPROVAL. 35.ALL REINFORCING BARS SHALL BE SECURELY HELD IN PLACE DURING CONCRETE POURING. IF REQUIRED, ADDITIONAL BARS SHALL BE PROVIDED BY THE CONTRACTOR TO FURNISH SUPPORT FOR THE BARS. 36.BARS SUPPORTS SHALL BE PLASTIC TIPPED FOR EXPOSED CONCRETE. LEGS OF FOUNDATIONS CHAIRS SHALL BE GALVANIZED. PLASTIC "DONUT" SPACERS WILL BE REQUIRED FOR STEEL AGAINST FORMS IN CONCRETE BEAMS & WALLS IF FIELD CONDITIONS WARRANT. This item has been digitally signed and sealed by Rodolfo Villamizar, P.E. on Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 10/20/2021 20-0029SHEET OF AS NOTED123456DATE: 20-0029 2INDIAN RIVER SPIRITS3200 N. KINGS HIGHWAYRVAERCW20-00291835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-36177JAN 2020RODOLFO VILLAMIZAR FL. P.E.#61000 ST. LUCIE COUNTYFLORIDAMELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055MOIA BOWLES VILLAMIZAR & ASSOCIATESCONSULTING ENGINEERING CA #3728REVISIONSDATEODOL F V LIL No. 61000 STATE OF ROFL ADI RF O RP ISSE ANO INEEE N GL ENSECILROAM Z I A R 10-20-202111-20-2020PERMIT SETCOORD. W/ BLDG DEPT.01-22-2110-20-21BY CONTRACTORPROPOSEDFOUNDATION PLANS1 1 2 2 ATTIC SPACE FRAMING PLAN SCALE: 1/8" = 1'-0" 1 2 3 4 5 6 A E D C B A E D C B 1 2 3 4 5 6 S2 1 TYP. S2 2 TYP. S2 3 S2 4 1 1 1 1 1 1 800S250-54 CFS METAL JOISTS @ 12" O.C. MAX.; TYP. 2 2 2 600S250-54 CFS VERTICAL STUDS @ 12" O.C. MAX.; TYP. S2 5 TYPICAL FOOTING INTERSECTION DETAIL SCALE: 1/2" = 1'-0" CORNER PLAN AT PAD PERPENDICULAR FOOTING PENETRATION DETAIL SCALE: N.T.S. SAW CUT DETAIL SCALE: 3/4" = 1'-0"SCALE: 1/2" = 1'-0" TYPICAL FOOTER DETAIL PREFABRICATED METAL BUILDING; SEE METAL BUILDING MFG.'S PLANS AND CONNECTION DETAIL; TYP. (2) MASONRY U-BLOCK W/ #5 REBAR x CONT. STUCCO FINISH PER ARCHITECT METAL FLASHING PER ARCHITECT CENERLINE OF BASEPLATE 42" HIGH 8" CMU WALL W/ #5 VERT. IN FILLED CELLS @ 48" O.C MAX. A.B. EMBED. PER SCHEDULE A.B. DESIGNED & FURNISHED BY METAL BUILDING MFG. FOOTER PER SCHEDULE WALL GIRT DESIGNED FOR 220 PLF LOAD PER METAL BUILDING MFG. 1 2" LDT @ 12" O.C. MAX. W/ 3.5" MIN.EMBED WALL GIRT PER METAL BUILDING MFG. SECTION SCALE: 1/2" = 1'-0" 3 S2 INSULATION PER ARCHITECTURALS CONCRETE BELL FOOTER PER PLAN & SCHEDULE CONCRETE SLAB PER PLAN CONCRETE SLAB PER PLAN 600S250-54 50 KSI METAL STUDS @ 12" O.C. 600T250-54 METAL TRACK W/ 0.145" DIA PAF TO SLAB @ 12" O.C. W/ (3) #8 SCREWS EA. STD EA. FLANGE 800s250-54 50 ksi METAL STUDS JOIST PER PLAN 600T250-54 METAL TRACK W/ (3) #8 SCREWS EA. STD EA. FLANGE STC SIMPSON ROOF TRUSS CLIPS W/ (2) #8 CBSDQ158S TO TRACK & (1) #8 CBSDQ158S TO JOIST TYP. SECTION SCALE: 1/2" = 1'-0" 2 S2 1200S162-68 50 KSI CFS STUDS; SEE PLAN FOR MAXIMUM SPACING; PLACE EA. VERTICAL CFS STUD DIRECTLY ALIGNED WITH EA. CFS FLOOR JOIST; TYP. INSULATION PER ARCH'L DWGS. CONCRETE SLAB PER PLAN CONCRETE SLAB PER PLAN 1200T200-68 METAL TRACK W/ 0.145" DIA PAF TO SLAB @ 12" O.C. W/ (3) #8 SCREWS EA. STD EA. FLANGE 1200T200-68 METAL TRACK W/ (3) #8 SCREWS EA. STD EA. FLANGE 1200S162-68 50 METAL STUDS @ 16" O.C CONNECT TO ROOF FRAMING. METAL BUILDING ROOF GIRTS CONT. 3 5/8"-20 Ga METAL TRACK (2) 6"x 15 4" x 20GA, BLOCKING BETWEEN GIRTS W/ 2x2x3x20GA. CLIP W/ (2) #8 EA. LEG; TYP. BRACE VERTICAL STUD WALL TO FLOOR JOIST W/ 16 GAUGE, 50KSI VERTICLIP SLB1200 @ 4FT O.C. MAX. W/ (5) #12-14 HWH SCREWS TO JOIST & (2) #12-14 HWH SCREWS TO STUD; TEKS "SELECT" SCREWS; TYP. 2x P.T. NAILERS AS REQUIRED SECTION SCALE: 1/2" = 1'-0" 1 S2 800S250-54 50 KSI CFS JOISTS; SEE PLAN INSULATION; SEE ARCH'L. CONCRETE BELL FOOTER PER PLAN & SCHEDULE CONCRETE SLAB PER PLAN FINISHES; SEE ARCH'L. 600S250-54 50 KSI CFS STUDS; SEE PLAN FOR SPACING; PLACE EA. VERTICAL CFS STUD DIRECTLY ALIGNED WITH EA. CFS FLOOR JOIST; TYP. 600T250-54 METAL TRACK W/ (3) #8 SCREWS EA. STD EA. FLANGE T&B 600T250-54 METAL TRACK W/ 0.145" DIA PAF TO SLAB @ 12" O.C. W/ (3) #8 SCREWS EA. STD EA. FLANGE STC SIMPSON ROOF TRUSS CLIPS W/ (2) #8 CBSDQ158S TO TRACK & (1) #8 CBSDQ158S TO JOIST TYP. DECKING; SEE ARCH'L. SECTION SCALE: 1/2" = 1'-0" 4 S2 800S250-54 50 KSI CFS JOISTS; SEE PLAN. INSULATION PER ARCH'L CONCRETE BELL FOOTER PER PLAN & SCHEDULE CONCRETE SLAB PER PLAN FINISHES PER ARCH'L 600S250-54 50 KSI METAL STUDS @ 12" O.C. W/ (3) #8 SCREWS EA. FLANGE T&B 800T250-54 CFS JOIST TRACK W/ (2) #8 TEKS SCREWS EA. JOIST, EA. FLANGE; TYP. 600T250-54 METAL TRACK W/ 0.145" DIA PAF TO SLAB @ 12" O.C. W/ (3) #8 SCREWS EA. STD EA. FLANGE STC SIMPSON ROOF TRUSS CLIPS W/ (2) #8 CBSDQ158S TO TRACK & (1) #8 CBSDQ158S TO JOIST TYP. 800S250-54 50 KSI CFS JOISTS; SEE PLAN. DECKING; SEE ARCH'L 600S250-54 50 KSI METAL STUDS @ 12" O.C. ANCHOR SCHEDULE 5/8" DIAM.11" W/ 3" THREAD & 8" MIN. EMBED. SIZE REMARKSLENGTH NOTE: ALL ANCHOR BOLTS, NUTS, AND WASHER MATERIAL SHALL BE HOT DIP GALVANIZED AS PER ASTM A123/A153 A194 GRADE 2H HEAVY HEX NUT W/ F436 WASHER F1554 GRADE 36 3/4" DIAM.18" W/ 3" THREAD & 15" MIN. EMBED.A193 B7 SCALE: 3/4" = 1'-0" TYPICAL 4' MASONRY WALL DETAIL CLEANOUT AT EA. DOWEL; TYP. 6" THICK CONCRETE SLAB W/ 6x6 W2.9xW2.9 WWF ON 6 MIL VAPOR BARRIER; TYP. FOOTER PER SCHEDULE #5 DOWELS @ EA. VERT. W/ 90° HOOK; TYP. 8" CMU IN RUNNING BOND W/ #5 VERT. IN FILLED CELLS @ 48" O.C MAX. (2) MASONRY U-BLOCK W/ #5 REBAR x CONT. STUCCO FINISH PER ARCHITECT METAL FLASHING PER ARCHITECT PREFABRICATED METAL BUILDING; SEE METAL BUILDING MFG.'S PLANS AND CONNECTION DETAIL; TYP. METAL STUD WALL PER SECTIONS WALL GIRT DESIGNED FOR 220 PLF LOAD PER METAL BUILDING MFG. 1 2" LDT @ 12" O.C. MAX. W/ 3.5" MIN.EMBED WALL GIRT PER METAL BUILDING MFG. This item has been digitally signed and sealed by Rodolfo Villamizar, P.E. on Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 10/20/2021 SECTION SCALE: 1/2" = 1'-0" 5 S2 1200S162-68 50 KSI CFS STUDS; SEE PLAN FOR MAXIMUM SPACING; PLACE EA. VERTICAL CFS STUD DIRECTLY ALIGNED WITH EA. CFS FLOOR JOIST; TYP. INSULATION PER ARCH'L DWGS. CONCRETE SLAB PER PLAN CONCRETE SLAB PER PLAN 1200T200-68 METAL TRACK W/ 0.145" DIA PAF TO SLAB @ 12" O.C. W/ (3) #8 SCREWS EA. STD EA. FLANGE 1200T200-68 METAL TRACK W/ (3) #8 SCREWS EA. STD EA. FLANGE 1200S162-68 50 METAL STUDS @ 16" O.C CONNECT TO ROOF FRAMING. METAL BUILDING ROOF GIRTS CONT. 3 5/8"-20 Ga METAL TRACK (2) 6"x 15 4" x 20GA, BLOCKING BETWEEN GIRTS W/ 2x2x3x20GA. CLIP W/ (2) #8 EA. LEG; TYP. 2x P.T. NAILERS AS REQUIRED 20-0029SHEET OF AS NOTED123456DATE: 20-0029 2INDIAN RIVER SPIRITS3200 N. KINGS HIGHWAYRVAERCW20-00291835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-36177JAN 2020RODOLFO VILLAMIZAR FL. P.E.#61000 ST. LUCIE COUNTYFLORIDAMELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055MOIA BOWLES VILLAMIZAR & ASSOCIATESCONSULTING ENGINEERING CA #3728REVISIONSDATEODOL F V LIL No. 61000 STATE OF ROFL ADI RF O RP ISSE ANO INEEE N GL ENSECILROAM Z I A R 10-20-202111-20-2020PERMIT SETCOORD. W/ BLDG DEPT.01-22-2110-20-21BY CONTRACTORPROPOSEDFRAMING PLAN, ANDSTRUCTURAL NOTESS2 1 1