Loading...
HomeMy WebLinkAboutAPPROVED, Widman Residence - Stamped full permit set - Rev1(1)SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-1 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT TITLE SHEET PROJECT LOCATION PROJECT INFORMATION x 37 X 365W LG365N1K-A6 MONOCRYSTALLINE PV MODULES x 1 X SOLAREDGE SE10000H-US INVERTER x DC SYSTEM SIZE: 13.505 KW STC x AC SYSTEM SIZE: 10.000 KW STC x ARRAY AREA: 721.63 SF x AHJ: SAINT LUCIE COUNTY x APN: 3419-530-0073-000-5 THIS PROJECT CONSISTS OF THE INSTALLATION OF (37) PHOTOVOLTAIC MODULES WITH (1) UTILITY INTERACTIVE INVERTER. PV MODULES WILL BE MOUNTED TO AN EXISTING COMP SHINGLE ROOF TOP USING QUICKMOUNT L-MOUNT ATTACHMENTS AND QUICKMOUNT RAIL. THE ATTACHMENT SYSTEM IS SPECIFICALLY DESIGNED TO WITHSTAND WIND LOADS AND SEISMIC LOADS ON EXISTING ROOFTOPS. REFER TO CODE COMPLIANT INSTALLATION MANUAL FOR DETAILED INFORMATION AND WATER PROOFING SPECIFICATIONS. PLAN SET LEGENDS & ABBREVIATIONS MSP SUB AC DC SLC INV MAIN SERVICE PANEL SUB SERVICE PANEL AC DISCONNECT DC DISCONNECT SOLAR LOAD CENTER INVERTER JB JUNCTION BOX ECB ENPHASE COMBINER BOX RS RAPID SHUTDOWN DEVICE (E) EXISTING (N) NEW EXT EXTERIOR INT INTERIOR EMT ELECTRICAL METALLIC TUBING RMT RIGID METALLIC TUBING VOC VOLTAGE OPEN CIRCUIT VMP VOLTAGE AT MAX. POWER ISC SHORT CIRCUIT CURRENT IMP CURRENT AT MAX. POWER M MONITORING METER NTS NOT TO SCALE SHEET INDEX SHEET NO. INDEX NO.PAGE TITLE 01 PV-1 TITLE SHEET 02 PV-1.1 GENERAL NOTES 03 PV-2 SITE PLAN 04 PV-3 ROOF PV LAYOUT 05 PV-4 STRING LAYOUT 06 PV-5 ATTACHMENT DETAIL 07 PV-6 ELECTRICAL LINE DIAGRAM 08 PV-7 SAFETY PLACARD 09 PV-8 MODULE DATASHEET 10 PV-9 INVERTER DATASHEET 11 PV-10 OPTIMIZER DATASHEET 12 PV-11 RACKING DATASHEET 13 PV-12 ATTACHMENT DATASHEET 14 PV-13 ATTACHMENT DATASHEET 15 PV-14 COMPLIANCE CERTIFICATE 16 PV-15 SEALANT DATASHEET 17 PV-16 SEALANT DATASHEET 18 PV-17 SEALANT DATASHEET VICINITY MAP SCALE: NTS AERIAL VIEW SCALE: NTS SCOPE OF WORK APPLICABLE CODES ALL WORK TO COMPLY WITH THE FOLLOWING CODES: x 2020 FLORIDA BUILDING CODE x 2020 FLORIDA RESIDENTIAL CODE x 2020 FLORIDA MECHANICAL CODE x 2017 NATIONAL ELECTRICAL CODE x 2020 FLORIDA GREEN CODE x 2020 FLORIDA PLUMBING CODE x 2020 FLORIDA ENERGY CODE x 2020 FLORIDA FIRE CODE DESIGN CRITERIA: ROOF TYPE: - ASPHALT SHINGLE ROOF FRAME: - 2"X4" TRUSS @24" O.C. SNOW LOAD : - 0 PSF WIND SPEED :- 160 MPH WIND EXPOSURE:- C EXPOSURE CATEGORY:- II COORDINATES :- 27.321919, -80.336305 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-1.1 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT NOTES GENERAL NOTES: x PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH 2011 NEC, AND THE 2012 IRC/IBC, AND APPLICABLE REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVING JURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 705.10 AND 705.12. x PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITH THE WIRING METHODS AND INSTALLATION AND MARKING REQUIREMENTS OF NEC 690.31(E). x BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND "BREAKERS ARE BACK FED" PER NEC 705.12. BREAKER ALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING AC VOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUIT BREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PER NEC 705.12(D)(7). x LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCH TO BE LOCKED PER 2011 NEC. SWITCH TO BE VISIBLE BLADE DISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22. x BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY. x DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOT TO BE x ADDED TO THIS PANEL." x ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND ATTACHED PER APPROVED METHOD. x EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINES DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR. x WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIRE READS "SUNLIGHT RESISTANT." x THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC GROUNDING ELECTRODE SYSTEM PER NEC 250.64. x AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2)(c). CONDUIT ELEVATED MIN. 3 1/2"; ADDER 30 DEG F. x ALL EXTERIOR EQUIPMENT TO BE NEMA 3R. x THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. AHJ NOTES: x THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE ELECTRICAL INSPECTOR AND ALL INSTALLERS PRESENT. AT THE PRE-CONSTRUCTION MEETING THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF APPROVED DRAWINGS AND A COMPLETE PERMIT PACK CONTAINING ALL MANUFACTURES SPECIFICATIONS FOR ALL EQUIPMENT, COMPONENTS, LABELS, AND ANY/ALL ANCILLARY MATERIALS TO BE INSTALLED. x AT THE PRE-CONSTRUCTION MEETING THE ELECTRICAL INSPECTOR SHALL REVIEW ALL DRAWING AND DOCUMENTS TO VERIFY ALL COMPONENTS TO BE INSTALLED CORRESPOND WITH THE APPROVED DOCUMENTS, ALL APPLICABLE LISTINGS, AND ALL MANUFACTURES SPECIFICATIONS. x AT THE PRE-CONSTRUCTION MEETING THE ELECTRICAL INSPECTOR SHALL VERIFY THE CREDENTIALS OF ALL WORKERS PRESENT ON THE JOB SITE. ALL WORKERS ON THE JOB SITE SHALL MEET THE REQUIREMENTS OF "QUALIFIED PERSONS" AS DEFINED BY NFPA 70 AND NFPA 70E. x AT THE PRE-CONSTRUCTION MEETING ACCEPTABLE DOCUMENTATION WOULD INCLUDE NABCEP PV INSTALLER SPECIALIST CERTIFICATION, NABCEP PV INSTALLATION PROFESSIONAL CERTIFICATION OR EQUIVALENT. ANY EQUIVALENT DOCUMENTATION SHALL BE RECOLONIZED BY THE DEPARTMENT OF LABOR OR THE DEPARTMENT OF EDUCATION AND SHALL INCLUDE TRAINING IN ALL APPLICABLE OSHA REQUIREMENTS INCLUDED IN THE NABCEP CERTIFICATION PROGRAM. x UPON SATISFACTORY COMPLETION OF PRE-CONSTRUCTION MEETING WORK SHALL BE ALLOWED TO BEGIN. x THE CONTRACTOR SHALL SCHEDULE A ROUGH INSPECTION. A ROUGH INSPECTION SHALL BE PERFORMED PRIOR TO THE INSTALLATION OF ANY PANELS. x AT THE ROUGH INSPECTION THE INSPECTOR SHALL EXAMINE ALL CONDUITS, BOXES, BUILDING WIRING, SERVICE CONNECTIONS, COMBINER BOXES, INVERTERS, RAILING/RACKING COMPONENTS AND CONNECTIONS, ALL FLASHINGS, AND ANY OTHER EQUIPMENT OR COMPONENTS WHICH FALL UNDER THE USUAL CATEGORIZATION OF A ROUGH INSPECTION. x AT THE ROUGH INSPECTION THE INSPECTOR SHALL CONFIRM ALL SERVICE GROUNDING AND BONDING COMPLY WITH CURRENT STANDARDS. x AT THE ROUGH INSPECTION THE CONTRACTOR SHALL SUPPLY THE INSPECTOR WITH ANY/ALL PPE REQUIRED BY OSHA. x AT THE ROUGH INSPECTION THE CONTRACTOR SHALL PROVIDE THE INSPECTOR WITH SAFE ACCESS TO THE ROOF AND ATTIC TO PERFORM HIS/HER DUTIES. x UPON APPROVAL OF ROUGH INSPECTION, WORK SHALL BE ALLOWED TO CONTINUE. x UPON COMPLETION OF ALL WORK THE CONTRACTOR SHALL SCHEDULE A FINAL INSPECTION. x AT THE FINAL INSPECTION THE SYSTEM SHALL BE ENERGIZED FOR A SHORT PERIOD OF TIME TO ALLOW FOR INSPECTION. A SHORT PERIOD OF TIME SHALL BE DEFINED AS LESS THE TWO HOURS. x UPON APPROVAL OF THE FINAL INSPECTION AND SUBMITTAL OF ALL ADDITIONAL DOCUMENTATION REQUIRED BY THE COUNTY COMMERCE COMMISSION AND THE UTILITY PROVIDER THE SYSTEM THEN SHALL BE ALLOWED TO BE ENERGIZED AND REMAIN IN ITS NORMAL OPERATING CONDITION. ELECTRICAL NOTES: x COMED REQUIRES AN INTERCONNECTION AGREEMENT PRIOR TO SYSTEM START UP. PROVIDE COPY OF THE APPLICATION WITH COMED. x ALL ELECTRIC WORK SHALL BE INSTALLED BY LICENSED SOLAR CERTIFIED ELECTRICAL CONTRACTOR. x ALL ELECTRIC SHALL BE IN CONDUIT. ALL ELECTRIC IN ATTICS SHALL BE 18 INCHES BELOW THE ROOF SHEATHING. x CALL FOR PRECONSTRUCTION INSPECTION. x SCHEDULE A ROUGH INSPECTION PRIOR TO PANEL INSTALLATION. x CALL TO SCHEDULE A FINAL ELECTRIC INSPECTION. x INSTALLER CERTIFICATES FOR QUALIFIED PERSONS. A LICENSED ELECTRICAL CONTRACTOR SHALL BE ON THE SITE AT ALL TIMES. OTHER CERTIFICATES INCLUDE NABCEP, UL CERTIFIED, ALL OTHER CERTIFICATE SHALL BE FROM A GOVERNING BODY RECOGNIZED BY THE US DEPARTMENT OF LABOR OR THE FLORIDA DEPARTMENT OF EDUCATION STATING QUALIFIED PERSON FOR DISTRIBUTED GENERATION. DESIGN CRITERIA: ROOF TYPE: - ASPHALT SHINGLE ROOF FRAME: - 2"X4" TRUSS @24" O.C. SNOW LOAD : - 0 PSF WIND SPEED :- 160 MPH WIND EXPOSURE:- C EXPOSURE CATEGORY:- II COORDINATES :- 27.321919, -80.336305 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-2 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT SITE PLAN 1 SITE PLAN PV-2 SCALE: 1/16" = 1'-0" (37) PV SOLAR MODULES (TYP.) 3' FIRE SETBACK (TYP.) FIRE ACCESS POINT (E) MAIN SERVICE PANEL, 200A RATED, 240V RESIDENCE (E) FENCE (E) GATE EXISTING DRIVEWAY (E) 1-STORY HOUSE x ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. (37) SOLAREDGE POWER OPTIMIZER P400 BELOW EACH PV MODULE (TYP.)SE TRANQUILLA AVEPROPERTY LINEPROPERTY LINEP R O P E R T Y L I N E PROPERTY LINE18" FIRE SETBACK (TYP.) 24" WIND ZONE 2 WIND ZONE 1 24" WIND ZONE 3 MSPPVMINVUMJB1'-6" 1'-6" 5'-9" 1' 15' 1'-6" 9'-5" 11'-4" 41'-11" 11'-3" 7'-9" SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-3 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT 1 ROOF PV LAYOUT SCALE: 1/8" = 1'-0"PV-3 NUMBER OF MODULES: 37 MODULE TYPE: LG365N1K-A6 365W MODULE WEIGHT: 41 LBS / 18.6 KG. MODULE DIMENSIONS: 68.5" X 41" MODULE AREA: 19.50 SF UNIT WEIGHT OF MODULES: 41/19.50 = 2.10 LBS MODULE TYPE, DIMENSIONS & WEIGHT INVERTER HAVE RAPID SHUTDOWN REQUIREMENTS PER NEC 2017 SECTION 690.12 ROOF PV LAYOUT ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ARRAY TILT AZIMUTH RAFTER SIZE RAFTER SPACING #1 18°225°2"x4" 24" O.C #2 18°135°2"x4" 24" O.C ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA (%) #1 6 117.02 239.59 49 #2 31 604.61 930 65 (E) BACK OF RESIDENCE(E) FRONT OF RESIDENCESE TRANQUILLA AVE(E) MAIN SERVICE PANEL, 200A RATED, 240V (N) 1-SOLAREDGE SE10000H-US INVERTER (N) PV PERFORMANCE METER (E) UTILITY METER FIRE ACCESS POINT (E) ROOF VENT (TYP.) (E) ROOF FRAMING SEE ROOF INFO 3/4 " EMT CONDUIT RUN ON ROOF/UNDER EAVE/ IN ATTIC (N) JUNCTION BOX ARRAY #1 (6) SOLAR MODULES (13) ATTACHMENTS @ 48" O.C. MAX. ARRAY #2 (31) SOLAR MODULES (68) ATTACHMENTS @ 48" O.C. MAX. (37) SOLAREDGE POWER OPTIMIZER P400 BELOW EACH PV MODULE (TYP.) 3' FIRE SETBACK (TYP.) 18" FIRE SETBACK (TYP.) 24" WIND ZONE 2 WIND ZONE 1 24" WIND ZONE 3 MSPPVMINVUMJBSHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-4 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT STRING LAYOUT 1 STRING LAYOUT PV-4 (37) LG365N1K-A6 365W MODULES (1) SOLAREDGE SE10000H-US INVERTER LOCATED AT EACH MODULE (02) STRING OF 12 MODULES CONNECTED IN SERIES (01) STRING OF 13 MODULES CONNECTED IN SERIES SCALE: 1/8" = 1'-0" BILL OF MATERIAL QUANTITY DESCRIPTION MODULES 37 LG LG365N1K-A6 365W SOLAR MODULES INVERTER 1 SOLAREDGE SE10000H-US INVERTER OPTIMIZER 37 SOLAREDGE POWER OPTIMIZERS P400 PV METER 1 PV PERFORMANCE METER ATTACHMENT 81 QUICKMOUNT L-MOUNT RAILS 22 QUICKMOUNT QRAIL LIGHT SPLICE 16 QUICKMOUNT SPLICE MID CLAMP 66 QUICKMOUNT QRAIL BONDING MID CLAMP END CLAMP 16 QUICKMOUNT UNIVERSAL END CLAMP END CAP 16 QUICKMOUNT END CAP GROUNDING LUG 4 QUICKMOUNT GROUND LUG ASSEMBLY, 6-12 AWG (E) BACK OF RESIDENCE(E) FRONT OF RESIDENCESE TRANQUILLA AVE1 1 1 1 1 1 1 1 1 1 1 1 2 2 32 32 32 32 32 32 32 32 32 32 33 3 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-5 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT 1 ATTACHMENT DETAIL PV-5 SCALE: NTS 1.1 ATTACHMENT DETAIL (ENLARGED VIEW) PV-5 SCALE: NTS ATTACHMENT & EQUIPMENT ELEVATION PV MODULE SEE ENLARGED VIEW (1.1 / PV-5)(E) COMP SHINGLE 2"x4" RAFTE R @ 24 " O.C. QUICKMOUNT RACKING SYSTEM PV MODULE GROUNDING END/MID CLAMP ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT QUICKMOUNT L-MOUNT 5/16"x3.5" SS LAG BOLT WITH MIN 212" THREAD EMBEDMENT, SEALED PENETRATION (E) COMP SHINGLE SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-6 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS LG SOLAR LG365N1K-A6 365W VMP= 35.1V VOC= 41.8V ISC= 10.92A IMP= 10.41A CEC PTC POWER= 338.2W SOLAREDGE SE10000H-US (240V) (SI1)INVERTER MAX DC VOLTAGE: 480V MAX INPUT POWER: 15.5KW MAX INPUT CURRENT: 27A MAX AC OUTPUT CURRENT: 42A CEC WEIGHTED EFFICIENCY: 99% @ 240VAC NEMA 6, UL 1741 LISTED x PV BREAKER IS TO BE LOCATED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. WIRE TAG # CONDUIT WIRE QTY (CARRY CURRENT) WIRE GAUGE (AWG)WIRE TYPE TEMP. RATING WIRE LOCATION ADJUSTED WIRE TEMP WIRE AMP TEMP. CORRECTION PER TABLE 310.15(B)(2)(a): CONDUIT FILL PER TABLE 310.15(B)(3)(a): WIRE OCP. TERMINAL 75°C RATING INVERTER QTY.AC OUTPUT CURRENT NEC 690.8(A)STRING AMPS GROUND SIZE GROUND TYPE OCPD CHECK 1 NONE 2 10 PV WIRE 90°C ROOF 55°C 40 X 0.76 X 1 = 30.4 35 1 X 15 X 1.25 = 18.75 #6 SBC N/A 2 3/4" EMT 6 10 THWN-2 90°C WALL 55°C 40 X 0.76 X 0.8 = 24.32 35 1 X 15 X 1.25 = 18.75 #8 THWN-2 20A 2P 3 3/4" EMT 36 THWN-290°C ATTIC 33°C 75 X 0.96 X 1 = 72.0 65 1 X 42 X 1.25 = 52.5 #8 THWN-2 60A 2P LOW MEAN TEMP PER ASHRAE HANDBOOK MFR VOLTAGE TEMP COEFFICIENT (Voc) VOLTAGE LOW TEMP. CORR. (oC) HIGH AMBIENT TEMP (oC) CONDUIT HEIGHT (in) ROOF TOP ADDED TEMP PER Table 310.15(B)(C)(OC) ADJUSTED TEMP ROOF 0°C -0.26 1.065 33°C 0.5-3.5 22°C 55°C WALL 0°C 33°C N/A 0°C 33°C ATTIC 0°C 33°C N/A 0°C 33°C METHOD TO CONTINUE SERIES/BRANCH ARRAY TYP. PV WIRE ARRAY TYP. PV WIRE TYP. CONDUIT MAX PV VOLTAGE & CURRENT CALCS: RECORD LOW TEMP (In Celsius)0°C AMBIENT TEMP (HIGH TEMP 2%) (In Celsius)33°C MODULE TEMPERATURE COEFFICIENT OF Voc -0.26%/°C VOLTAGE CORRECTION 1.065 VCORRECTION * VOC (1.065 * 41.8)44.52 V MAX PV CONTINUOUS CURRENT PER STRING (1.25 X Isc X # STRINGS)13.65A 120% RULE BUS BAR 200 MAIN BREAKER 150 ALLOWED MAX PV OCPD 90 (37) LG365N1K-A6 365W MODULES (1) SOLAREDGE SE10000H-US INVERTER LOCATED AT EACH MODULE (02) STRING OF 12 MODULES CONNECTED IN SERIES (01) STRING OF 13 MODULES CONNECTED IN SERIES JUNCTION BOX 600 V, NEMA 3 UL LISTED (3) #10 AWG THWN-2 + RED (3) #10 AWG THWN-2 - BLACK (1) #10 AWG GND 3/4" EMT CONDUIT (1) #10 AWG USE-2/PV WIRE + Red IN FREE AIR (1) #10 AWG USE-2/PV WIRE - Black IN FREE AIR (1) #6 BARE COPPER GND = DC AC (N) SOLAR EDGE SE10000H-US[S|1] WITH DC DISCONNECT & AFCI EXISTING GROUNDING ELECTRODE SYSTEM G N M TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V (3) #6 AWG THWN-2 (1) #8 AWG GND 3/4" EMT CONDUIT SolarEdge Power Optimizer P400 Rated DC Input Power - 400 watts Maximum Input Voltage - 80 Vdc MPPT Range - 8 to 80 Vdc Maximum Input Current - 12.5 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 6000 watts STC per string maximum 150 A 21 = = 12 (N) PV PERFORMANCE METER 60A 2 POLE 60A PV BREAKER BACKFEED (E) 200A MAIN SERVICE PANEL 1PH,120/240V,3W, TOP MAIN BREAKER (E) MAIN BREAKER, 150A= = = = 21 = = 12 = = = = 21 = = 13 = = = = # ## #   "# #  #  # "## # ## #  # # # #  # #   # ##   # # #  # # #   # # #!   ##"#   #  # SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-7 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT SAFETY PLACARD 1 SAFETY PLACARD PV-7 SCALE: NTS LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): 690.31(G)(4) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): 605.11.1 PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): 690.35(F) PV SYSTEM DISCONNECT FOR UTILITY OPERATION SOLAR AC DISCONNECT ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): 690.17(E) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): 705.12(D)(4) 1 2 3 4 5 6 LABEL LOCATION: MAIN SERVICE DISCONNECT LABEL LOCATION: SOLAR AC DISCONNECT 7 8 9 LABEL LOCATION: UTILITY AC DISCONNECT PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. 10 ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): 705.12(D)(2)(3)(c) ! ! ! CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT AS SHOWN EQUIPMENT AT 1 METER AND MAIN SERVICE 2 INVERTER 3 PV METER EQUIPMENT AT EACH MODULE -MICROINVERTER MIN.6"x6" PLACARD TO GO ON MAIN SERVICE PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(4)) !11 SE TRANQUILLAAVE123 # ## #   "# #  #  # "## # ## #  # # # #  # #   # ##   # # #  # # #   # # #!   ##"#   #  # MODULE DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-8 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT INVERTER DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-9 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT OPTIMIZER DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-10 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT RACKING DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-11 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT ATTACHMENT DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-12 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT ATTACHMENT DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-13 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT COMPLIANCE CERTIFICATE SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-14 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-15 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT SEALANT DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-16 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT SEALANT DATA SHEET SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PV-17 MERAKI DESIGN & CONSTRUCTION LLC PROJECT ADDRESS REVDATEDESCRIPTION REVISIONS 09/3/2021FOR REVIEW 1801 CEDAR DR, COCONUT CREEK,FL 33063 Tel: (954) 993-6757 LIC. NO.: CVC 57098 421 SE TRANQUILLA AVEPORT ST. LUCIE, FL 34983, USAPHONE: (772) 871-6626WIDMAN, RUDOLPH110/8/2021SEALANT 210/21/2021SEALANT SEALANT DATA SHEET