Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALC & EPL CARD11770 PALOMINO DRIVE, FORT PIERCE, FL, EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 4 No 2116 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 215.00 ft² SHGC=0.25 Sgl, U=0.65 117.33 ft² SHGC=0.30 N/A f t ² N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2116.00 ft² R= f t ² R= f t ² 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior R=4.1 1949.00 ft² b. Frame - Wood, Adjacent R=11.0 242.67 ft² c. N/A R= f t ² 11. Ceiling Type and insulation level a. Roof Deck (Unvented)R=20.0 2116.00 ft² f t ² R =b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 50 gallons EF: 0.98 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method)None Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 6.026 ft. 0.268 a. Electric Strip Heat 27.0 COP:1.00 a. Central Unit 36.0 SEER:16.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: Attic 6 150 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 4/8/2021 12:29 AM ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� ����������������������������������������������������� EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 74/8/2021 12:29 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. DONOVAN RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 11770 PALOMINO DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 2116 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.65 215.00 ft² SHGC=0.25 Sgl, U=0.65 117.33 ft² SHGC=0.30 N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2116.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1949.00 ft² b. Frame - Wood, Adjacent R=11.0 242.67 ft² c. N/A R=f t ² 11. Ceiling Types a. Roof Deck (Unvented)R=20.0 2116.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:6.026 ft. Area Weighted Average SHGC:0.268 Description Area Insulation Area Insulation Area Insulation Area 16. Credits None 4 (332.3 sqft.) (2191.7 sqft.) (2116.0 sqft.) (2116.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 36.0 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 150 EF: 0.980 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.157 Total Proposed Modified Loads: Total Baseline Loads: 69.43 71.41 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 4-8-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. 1 DONOVAN RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2116 4 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie 11770 PALOMINO DRI Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2116 20854.2 Number NameAreaVolume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 MASTER BEDROO 288 2966.4 No 01 Yes Yes1Yes 2M WIC 90 837 No 0 Yes Yes1Yes 3 M BATH 160 1488 No 0 Yes Yes1Yes 4M TOILET28260.4 No 0 Yes Yes1Yes 5 LIVING ROOM 347 3817 No 0 Yes Yes1Yes 6 FOYER 64 640 No 0 Yes Yes1Yes 7 BEDROOM 2 166 1660 No 01 Yes Yes1Yes 8 KITCHEN1951950 Yes 0 Yes Yes1No 9 UTILITY RM 72 669.6 No 0 Yes Yes1No 10 CLST 3 18 167.4 No 0 Yes Yes1No 11 BEDROOM 3 203 1887.9 No 01 Yes Yes1Yes 12 BATH 2 78 725.4 No 0 Yes Yes1Yes 13 CLST 4 20 186 No 0 Yes Yes1Yes 14 BEDROOM 4 169 1571.7 No 01 Yes Yes1Yes 15 DINING RM 142 1320.6 No 0 Yes Yes1Yes 16 HALL 60 558 No 0 Yes Yes1No 17 WH CLST655.8 No 0 Yes Yes1No 18 CLST 2 10 93 No 0 Yes Yes1Yes 4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 288 ft² 100______ Slab-On-Grade Edge Insulation - - - -36 ft MASTER BEDRO 2 90 ft² 100______ Slab-On-Grade Edge Insulation - - - -10 ft M WIC 3 160 ft² 100______ Slab-On-Grade Edge Insulation - - - -31 ft M BATH 4 28 ft² 100______ Slab-On-Grade Edge Insulation - - - -6 ft M TOILET 5 347 ft² 100______ Slab-On-Grade Edge Insulation - - - -19 ft LIVING ROOM 6 64 ft² 100______ Slab-On-Grade Edge Insulation - - - -8 ft FOYER 7 166 ft² 100______ Slab-On-Grade Edge Insulation - - - -14 ft BEDROOM 2 8 195 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft KITCHEN 9 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft UTILITY RM 10 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft CLST 3 11 203 ft² 100______ Slab-On-Grade Edge Insulation - - - -13 ft BEDROOM 3 12 78 ft² 100______ Slab-On-Grade Edge Insulation - - - -19 ft BATH 2 13 20 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft CLST 4 14 169 ft² 100______ Slab-On-Grade Edge Insulation - - - -13 ft BEDROOM 4 15 142 ft² 100______ Slab-On-Grade Edge Insulation - - - -27 ft DINING RM 16 60 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft HALL 17 6 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft WH CLST 18 10 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft CLST 2 #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1Hip Metal 2366 ft² Light 0.2 20 26.57______No0 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2116 ft² N N0 4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 288 ft² 0.1 Wood______MASTER BEDRO Blown 2 Under Attic (Unvented)0 90 ft² 0.1 Wood______M WIC Blown 3 Under Attic (Unvented)0 160 ft² 0.1 Wood______M BATH Blown 4 Under Attic (Unvented)0 28 ft² 0.1 Wood______M TOILET Blown 5 Under Attic (Unvented)0 347 ft² 0.1 Wood______LIVING ROOM Blown 6 Under Attic (Unvented)0 64 ft² 0.1 Wood______FOYER Blown 7 Under Attic (Unvented)0 166 ft² 0.1 Wood______BEDROOM 2 Blown 8 Under Attic (Unvented)0 195 ft² 0.1 Wood______KITCHEN Blown 9 Under Attic (Unvented)0 72 ft² 0.1 Wood______UTILITY RM Blown 10 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 3 Blown 11 Under Attic (Unvented)0 203 ft² 0.1 Wood______BEDROOM 3 Blown 12 Under Attic (Unvented)0 78 ft² 0.1 Wood______BATH 2 Blown 13 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 4 Blown 14 Under Attic (Unvented)0 169 ft² 0.1 Wood______BEDROOM 4 Blown 15 Under Attic (Unvented)0 142 ft² 0.1 Wood______DINING RM Blown 16 Under Attic (Unvented)0 60 ft² 0.1 Wood______HALL Blown 17 Under Attic (Unvented)0 6 ft² 0.1 Wood______WH CLST Blown 18 Under Attic (Unvented)0 10 ft² 0.1 Wood______CLST 2 Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0MASTER BE 040 1 4 1 0NConcrete Block - Int Insul 0.20Exterior144.7 ft² ____ 2 4.1 0MASTER BE 040 5 1 0EConcrete Block - Int Insul 0.20Exterior51.7 ft² ____ 3 4.1 0MASTER BE 040 1 7 1 0WConcrete Block - Int Insul 0.20Exterior175.7 ft² ____ 4 4.1 0M WIC 040 1 0 9WConcrete Block - Int Insul 0.20Exterior93.3 ft² ____ 5 4.1 0M BATH 040 5 9EConcrete Block - Int Insul 0.20Exterior46.7 ft² ____ 6 4.1 0M BATH 040 1 4 9SConcrete Block - Int Insul 0.20Exterior130.7 ft² ____ 7 4.1 0M BATH 040 1 2 9WConcrete Block - Int Insul 0.20Exterior112.0 ft² ____ 8 4.1 0M TOILET 040 2 9EConcrete Block - Int Insul 0.20Exterior18.7 ft² ____ 9 4.1 0M TOILET 040 4 9SConcrete Block - Int Insul 0.20Exterior37.3 ft² ____ 10 4.1 0LIVING ROO 000 1 9 1 1NConcrete Block - Int Insul 0.20Exterior209.0 ft² ____ 11 4.1 0FOYER000 8 1 0SConcrete Block - Int Insul 0.20Exterior80.0 ft² ____ 12 4.1 0BEDROOM 2 000 1 2 1 0SConcrete Block - Int Insul 0.20Exterior120.0 ft² ____ 13 4.1 0BEDROOM 2 000 2 1 0WConcrete Block - Int Insul 0.20Exterior20.0 ft² ____ 14 11 0UTILITY RM 040 6 9S Frame - Wood 0.20.1Garage56.0 ft² ____ 15 11 0CLST 3 040 2 9S Frame - Wood 0.20.1Garage18.7 ft² ____ 16 4.1 0BEDROOM 3 040 1 3 9EConcrete Block - Int Insul 0.20Exterior121.3 ft² ____ 17 11 0BEDROOM 3 040 1 3 9S Frame - Wood 0.20.1Garage121.3 ft² ____ 18 4.1 0BATH 2 040 1 3 9NConcrete Block - Int Insul 0.20Exterior121.3 ft² ____ 19 4.1 0BATH 2 040 6 9EConcrete Block - Int Insul 0.20Exterior56.0 ft² ____ 20 4.1 0CLST 4 040 2 9EConcrete Block - Int Insul 0.20Exterior18.7 ft² ____ 21 4.1 0BEDROOM 4 040 1 3 9EConcrete Block - Int Insul 0.20Exterior121.3 ft² ____ 22 4.1 0DINING RM 040 1 7 9NConcrete Block - Int Insul 0.20Exterior158.7 ft² ____ 4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 23 4.1 0DINING RM 040 1 0 9WConcrete Block - Int Insul 0.20Exterior93.3 ft² ____ 24 4.1 0CLST 2 040 2 9SConcrete Block - Int Insul 0.20Exterior18.7 ft² ____ 25 11 0CLST 2 040 5 9E Frame - Wood 0.20.1Garage46.7 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1N Low-E Single 0.65 0.25 20.0 ft² 7 ft 6 in 1 ft 4 in NoneMetal None______Yes1 Y 2W Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes3 Y 3S Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes6 Y 4W Low-E Single 0.65 0.25 12.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes7 Y 5N Low-E Single 0.65 0.3 48.0 ft² 12 ft 6 in 1 ft 4 in NoneMetal None______Yes10 Y 6S Low-E Single 0.65 0.25 12.0 ft² 10 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes11 Y 7S Low-E Single 0.65 0.3 48.0 ft² 10 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes11 Y 8S Low-E Single 0.65 0.25 36.0 ft² 7 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes12 Y 9E Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes16 Y 10 E Low-E Single 0.65 0.25 10.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes19 Y 11 E Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes21 Y 12 N Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal None______Yes22 Y 13 N Low-E Single 0.65 0.3 21.3 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal None______Yes22 Y 14 W Low-E Single 0.65 0.25 20.0 ft² 6 ft 6 in 1 ft 4 in Drapes/blindsMetal None______Yes23 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 483 ft² 483 ft² 26 ft 8 ft 1______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1737.8 595.34.000313Wholehouse .0981179Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 36 kBtu/hr 1080 cfm 0.8______sys#1Split1 Single 4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 55.1 gal 120 deg None______None WH CLST FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 150 ft² Attic 15 ft² Default Leakage Attic (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 12345678910 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area T hickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 ELEV 2ND FLR Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3 Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 STAIRS 3RD FLR Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV 3RD FLR Default(8 lbs/sq.ft.f t ² f t 0.3 MECH AND STORA Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area T hickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 ENTRY Default(8 lbs/sq.ft.f t ² f t 0.3 W/D Default(8 lbs/sq.ft.f t ² f t 0.3 SITTING RM Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 STAIR STORAGE Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV. 1ST FLR 4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������