HomeMy WebLinkAboutAPPROVED ENERGY CALC & EPL CARD11770 PALOMINO DRIVE, FORT PIERCE, FL,
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft²)
New (From Plans)
Detached
1
4
No
2116
7. Windows**
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 215.00 ft²
SHGC=0.25
Sgl, U=0.65 117.33 ft²
SHGC=0.30
N/A f t ²
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2116.00 ft²
R= f t ²
R= f t ²
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior R=4.1 1949.00 ft²
b. Frame - Wood, Adjacent R=11.0 242.67 ft²
c. N/A R= f t ²
11. Ceiling Type and insulation level
a. Roof Deck (Unvented)R=20.0 2116.00 ft²
f t ² R =b. N/A
c. N/A R = f t ²
12. Ducts, location & insulation level
13. Cooling systems
14. Heating systems k B t u / h r
15. Hot water systems
a. Electric Cap: 50 gallons
EF: 0.98
b. Conservation features
None
d. N/A R= f t ²
Description Area
Insulation Area
Insulation Area
Insulation Area
Credits (Performance method)None
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
6.026 ft.
0.268
a. Electric Strip Heat 27.0 COP:1.00
a. Central Unit 36.0 SEER:16.00
k B t u / h r
Efficiency
Efficiency
a. Sup: Attic, Ret: Attic, AH: Attic 6 150
R f t ²
8. Skylights
a. U-Factor(AVG):
S H G C ( A V G ) :
Description Area
N/A
N/A
f t ²
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date:
Address of New Home:City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
Page 1 of 1
FORM R405-2020
4/8/2021 12:29 AM
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 74/8/2021 12:29 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC. DONOVAN RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
11770 PALOMINO DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
2116
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.65 215.00 ft²
SHGC=0.25
Sgl, U=0.65 117.33 ft²
SHGC=0.30
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2116.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1949.00 ft²
b. Frame - Wood, Adjacent R=11.0 242.67 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2116.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:6.026 ft.
Area Weighted Average SHGC:0.268
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits None
4
(332.3 sqft.)
(2191.7 sqft.)
(2116.0 sqft.)
(2116.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
36.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 150
EF: 0.980
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.157
Total Proposed Modified Loads:
Total Baseline Loads:
69.43
71.41 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
4-8-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
1
DONOVAN RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2116
4
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
11770 PALOMINO DRI
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2116 20854.2
Number NameAreaVolume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 MASTER BEDROO 288 2966.4 No 01 Yes Yes1Yes
2M WIC 90 837 No 0 Yes Yes1Yes
3 M BATH 160 1488 No 0 Yes Yes1Yes
4M TOILET28260.4 No 0 Yes Yes1Yes
5 LIVING ROOM 347 3817 No 0 Yes Yes1Yes
6 FOYER 64 640 No 0 Yes Yes1Yes
7 BEDROOM 2 166 1660 No 01 Yes Yes1Yes
8 KITCHEN1951950 Yes 0 Yes Yes1No
9 UTILITY RM 72 669.6 No 0 Yes Yes1No
10 CLST 3 18 167.4 No 0 Yes Yes1No
11 BEDROOM 3 203 1887.9 No 01 Yes Yes1Yes
12 BATH 2 78 725.4 No 0 Yes Yes1Yes
13 CLST 4 20 186 No 0 Yes Yes1Yes
14 BEDROOM 4 169 1571.7 No 01 Yes Yes1Yes
15 DINING RM 142 1320.6 No 0 Yes Yes1Yes
16 HALL 60 558 No 0 Yes Yes1No
17 WH CLST655.8 No 0 Yes Yes1No
18 CLST 2 10 93 No 0 Yes Yes1Yes
4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 288 ft² 100______ Slab-On-Grade Edge Insulation - - - -36 ft MASTER BEDRO
2 90 ft² 100______ Slab-On-Grade Edge Insulation - - - -10 ft M WIC
3 160 ft² 100______ Slab-On-Grade Edge Insulation - - - -31 ft M BATH
4 28 ft² 100______ Slab-On-Grade Edge Insulation - - - -6 ft M TOILET
5 347 ft² 100______ Slab-On-Grade Edge Insulation - - - -19 ft LIVING ROOM
6 64 ft² 100______ Slab-On-Grade Edge Insulation - - - -8 ft FOYER
7 166 ft² 100______ Slab-On-Grade Edge Insulation - - - -14 ft BEDROOM 2
8 195 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft KITCHEN
9 72 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft UTILITY RM
10 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft CLST 3
11 203 ft² 100______ Slab-On-Grade Edge Insulation - - - -13 ft BEDROOM 3
12 78 ft² 100______ Slab-On-Grade Edge Insulation - - - -19 ft BATH 2
13 20 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft CLST 4
14 169 ft² 100______ Slab-On-Grade Edge Insulation - - - -13 ft BEDROOM 4
15 142 ft² 100______ Slab-On-Grade Edge Insulation - - - -27 ft DINING RM
16 60 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft HALL
17 6 ft² 100______ Slab-On-Grade Edge Insulation - - - -1 ft WH CLST
18 10 ft² 100______ Slab-On-Grade Edge Insulation - - - -2 ft CLST 2
#Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1Hip Metal 2366 ft² Light 0.2 20 26.57______No0 ft² 0.9 NoN
ATTIC
#Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2116 ft² N N0
4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
#Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 288 ft² 0.1 Wood______MASTER BEDRO Blown
2 Under Attic (Unvented)0 90 ft² 0.1 Wood______M WIC Blown
3 Under Attic (Unvented)0 160 ft² 0.1 Wood______M BATH Blown
4 Under Attic (Unvented)0 28 ft² 0.1 Wood______M TOILET Blown
5 Under Attic (Unvented)0 347 ft² 0.1 Wood______LIVING ROOM Blown
6 Under Attic (Unvented)0 64 ft² 0.1 Wood______FOYER Blown
7 Under Attic (Unvented)0 166 ft² 0.1 Wood______BEDROOM 2 Blown
8 Under Attic (Unvented)0 195 ft² 0.1 Wood______KITCHEN Blown
9 Under Attic (Unvented)0 72 ft² 0.1 Wood______UTILITY RM Blown
10 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 3 Blown
11 Under Attic (Unvented)0 203 ft² 0.1 Wood______BEDROOM 3 Blown
12 Under Attic (Unvented)0 78 ft² 0.1 Wood______BATH 2 Blown
13 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 4 Blown
14 Under Attic (Unvented)0 169 ft² 0.1 Wood______BEDROOM 4 Blown
15 Under Attic (Unvented)0 142 ft² 0.1 Wood______DINING RM Blown
16 Under Attic (Unvented)0 60 ft² 0.1 Wood______HALL Blown
17 Under Attic (Unvented)0 6 ft² 0.1 Wood______WH CLST Blown
18 Under Attic (Unvented)0 10 ft² 0.1 Wood______CLST 2 Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0MASTER BE 040 1 4 1 0NConcrete Block - Int Insul 0.20Exterior144.7 ft² ____
2 4.1 0MASTER BE 040 5 1 0EConcrete Block - Int Insul 0.20Exterior51.7 ft² ____
3 4.1 0MASTER BE 040 1 7 1 0WConcrete Block - Int Insul 0.20Exterior175.7 ft² ____
4 4.1 0M WIC 040 1 0 9WConcrete Block - Int Insul 0.20Exterior93.3 ft² ____
5 4.1 0M BATH 040 5 9EConcrete Block - Int Insul 0.20Exterior46.7 ft² ____
6 4.1 0M BATH 040 1 4 9SConcrete Block - Int Insul 0.20Exterior130.7 ft² ____
7 4.1 0M BATH 040 1 2 9WConcrete Block - Int Insul 0.20Exterior112.0 ft² ____
8 4.1 0M TOILET 040 2 9EConcrete Block - Int Insul 0.20Exterior18.7 ft² ____
9 4.1 0M TOILET 040 4 9SConcrete Block - Int Insul 0.20Exterior37.3 ft² ____
10 4.1 0LIVING ROO 000 1 9 1 1NConcrete Block - Int Insul 0.20Exterior209.0 ft² ____
11 4.1 0FOYER000 8 1 0SConcrete Block - Int Insul 0.20Exterior80.0 ft² ____
12 4.1 0BEDROOM 2 000 1 2 1 0SConcrete Block - Int Insul 0.20Exterior120.0 ft² ____
13 4.1 0BEDROOM 2 000 2 1 0WConcrete Block - Int Insul 0.20Exterior20.0 ft² ____
14 11 0UTILITY RM 040 6 9S Frame - Wood 0.20.1Garage56.0 ft² ____
15 11 0CLST 3 040 2 9S Frame - Wood 0.20.1Garage18.7 ft² ____
16 4.1 0BEDROOM 3 040 1 3 9EConcrete Block - Int Insul 0.20Exterior121.3 ft² ____
17 11 0BEDROOM 3 040 1 3 9S Frame - Wood 0.20.1Garage121.3 ft² ____
18 4.1 0BATH 2 040 1 3 9NConcrete Block - Int Insul 0.20Exterior121.3 ft² ____
19 4.1 0BATH 2 040 6 9EConcrete Block - Int Insul 0.20Exterior56.0 ft² ____
20 4.1 0CLST 4 040 2 9EConcrete Block - Int Insul 0.20Exterior18.7 ft² ____
21 4.1 0BEDROOM 4 040 1 3 9EConcrete Block - Int Insul 0.20Exterior121.3 ft² ____
22 4.1 0DINING RM 040 1 7 9NConcrete Block - Int Insul 0.20Exterior158.7 ft² ____
4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
23 4.1 0DINING RM 040 1 0 9WConcrete Block - Int Insul 0.20Exterior93.3 ft² ____
24 4.1 0CLST 2 040 2 9SConcrete Block - Int Insul 0.20Exterior18.7 ft² ____
25 11 0CLST 2 040 5 9E Frame - Wood 0.20.1Garage46.7 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1N Low-E Single 0.65 0.25 20.0 ft² 7 ft 6 in 1 ft 4 in NoneMetal None______Yes1 Y
2W Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes3 Y
3S Low-E Single 0.65 0.25 15.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes6 Y
4W Low-E Single 0.65 0.25 12.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes7 Y
5N Low-E Single 0.65 0.3 48.0 ft² 12 ft 6 in 1 ft 4 in NoneMetal None______Yes10 Y
6S Low-E Single 0.65 0.25 12.0 ft² 10 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes11 Y
7S Low-E Single 0.65 0.3 48.0 ft² 10 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes11 Y
8S Low-E Single 0.65 0.25 36.0 ft² 7 ft 6 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes12 Y
9E Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes16 Y
10 E Low-E Single 0.65 0.25 10.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes19 Y
11 E Low-E Single 0.65 0.25 20.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes21 Y
12 N Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal None______Yes22 Y
13 N Low-E Single 0.65 0.3 21.3 ft² 1 ft 6 in 1 ft 4 in Drapes/blindsMetal None______Yes22 Y
14 W Low-E Single 0.65 0.25 20.0 ft² 6 ft 6 in 1 ft 4 in Drapes/blindsMetal None______Yes23 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 483 ft² 483 ft² 26 ft 8 ft 1______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1737.8 595.34.000313Wholehouse .0981179Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 36 kBtu/hr 1080 cfm 0.8______sys#1Split1 Single
4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 55.1 gal 120 deg None______None WH CLST
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 150 ft² Attic 15 ft² Default Leakage Attic (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 12345678910 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area T hickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 ELEV 2ND FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 STAIRS 3RD FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV 3RD FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 MECH AND STORA
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1
4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area T hickness Furniture Fraction Space
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 ENTRY
Default(8 lbs/sq.ft.f t ² f t 0.3 W/D
Default(8 lbs/sq.ft.f t ² f t 0.3 SITTING RM
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 STAIR STORAGE
Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV. 1ST FLR
4/8/2021 12:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������