HomeMy WebLinkAboutNew CBS Building PlansGOVERNING CODES AND STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL GOVERNING CODES, STANDARDS AND SPECIFICATIONS OF THE LATEST ADOPTED EDITION NOT LIMITED TO THE FOLLOWING: FLORIDA BUILDING CODE, 2017, 6th EDITION FLORIDA BUILDING CODE EXISTING BUILDING, 2017, 6th EDITION FLORIDA BUILDING CODE PLUMBING, 2017, 6th EDITION FLORIDA BUILDING CODE MECHANICAL, 2017, 6th EDITION FLORIDA BUILDING CODE FUEVGAS, 2017, 6th EDITION FLORIDA FIRE PREVENTION CODE, 2017 (NATIONAL FIRE PROTECTION AGENCY [NFPA] 1 FIRE CODE & NFPA 101 LIFE SAFETY CODE, 2012) FLORIDA ACCESSIBILITY CODE, 2017, 6th EDITION NFPA 70 NATIONAL ELECTRIC CODE (NEC) 2014 202 MIDVVAY ROAD FORT PI RC I F ORIDA 0 (St. Lucie County) PERMIT SET: FE.'BRUARY 17, 2021 .''.' N Sheet List Sheet Number Sheet Name A01 GEN NOTES, SYMB, ABBREVIATIONS A02 ACCESSIBILITY REQUIREMENTS 1 A03 ACCESSIBILITY REQUIREMENTS 2 A05 _ LIFE SAFETY PLAN_ A101 FLOOR PLAN A105 ELEVATIONS A106 ELEVATIONS A501 PARTITION TYPES & DETAILS A561 MISC. DETAILS BA108 TYPICAL DETAILS TYPICAL DETAILS TYPICAL DETAILS WALL SECTIONS & PARTITION TYPES BA109 BA110 NA107 ARCHITECT'S OR ENGINEER'S AFFIDAVIT STATEMENT TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND CHAPTER 633, FLORIDA STATUES. ARCHITECT'S OR ENGINEER'S AFFIDAVIT STATEMENT THE PRODUCTS REQUIRING (FLORIDA PRODUCT APPROVAL) SUBMITTAL TO BUILDING DEPARTMENT SHALL BE A DEFERRED SUBMITTAL, WHICH SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR. CONTRACTOR SHALL SUBMIT ALL PRODUCTS APPROVALS TO ARCHITECT, ENGINEER AND OWNER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL. TO BUILDING DEPARTMENT United Pentecostal Fire Ministries NEW CBS BUILDING 1202 E M I DWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com i a�Jz� AUDIE ROBINSON, AR0094296 No. Description Date �REV",iEWLO FOR �. .. "Al �1 COVERSHEET /r'� NN'`t i (�'l v Project number UPFM001 Date 04/17/2021 Drawn by MN Checked by AR RECEIVED 19 2021 AOOO scd[ett'n°; r As indicated tIts- GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH THE 2017, 6TH EDITION, FLORIDA BUILDING CODE WITH LOCAL AMENDMENTS AND WITH ALL OTHER CODES, AND ORDINANCES. 2. ALL WORK RELATING TO THIS CONSTRUCTION SHALL COMPLY WITH U.S. DEPARTMENT OF LABOR, THE OCCUPATIONAL SAFETY AND HEALTH STANDARDS AND ALL RELATED LOCAL BUILDING CODES AND ORDINANCES. 3. DO NOT SCALE THE DOCUMENTS. 4. ALL DIMENSIONS ARE TO BE FIELD VERIFIED AND BACK CHECKED FOR CORRECTNESS. IF ANY DEVIATIONS OR DISCREPANCIES OCCUR, CONTACT THE ARCHITECT FOR VERIFICATION PRIOR TO PROCEEDING WITH THE WORK. 5. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL CAREFULLY REVIEW THE DRAWINGS, DETAILS AND NOTES FOR INFORMATION REGARDING THE SCOPE OF THE WORK INTENDED PRIOR TO PROCEEDING WITH THE WORK. 6. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO INDUSTRY STANDARDS, ALL AGENCIES OR "STANDARD" RECOMMENDATIONS REFERENCED IN THE SPECIFICATIONS, OR MANUFACTURERS RECOMMENDED INSTALLATION PROCEDURES, WHICHEVER IS THE MOST STRINGENT, IN ORDER TO PROVIDE A COMPLETE AND HIGH QUALITY PROJECT. MATERIALS, SYSTEMS OR INSTALLATIONS NOT INSTALLED PER INDUSTRY STANDARDS OR MANUFACTURERS RECOMMENDATIONS SHALL BE REJECTED OR REMOVED. 7. THE CONTRACTOR REPRESENTS AND WARRANTS THAT IT HAS EXAMINED THE PLANS, DRAWINGS AND ALL CONSTRUCTION CRITERIA OF OWNER AND HAS SATISFIED ITSELF THAT THE INFORMATION CONTAINED THEREIN IS SUFFICIENT TO FULLY AND COMPLETELY CONSTRUCT THE PROJECT. 8. ALL EXTERIOR BUILDING COMPONENTS SHALL HAVE FLORIDA PRODUCT APPROVAL OR MIAMI/ DADE NOA OR ENGINEERED SOLUTION. 9. GENERAL NOTES APPLY TO ALL DRAWINGS. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING ABOVE AND BELOW GROUND UTILITIES WITHIN CONTRACT LIMITS & PROTECT THEM FROM DAMAGE DURING THE COURSE OF THIS CONSTRUCTION. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF, AND RESPONSIBILITY FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGE CAUSED BY THEMSELVES OR THEIR SUBCONTRACTOR'S OPERATIONS. UTILITIES DEACTIVATED OR ABANDONED IN PLACE BY THIS PROJECT SHALL BE CAPPED OR SEALED OFF IN ACCORDANCE WITH LOCAL REGULATIONS. 11. CONTRACTOR SHALL SUBMIT ALL MATERIALS & COLOR SAMPLES TO OWNER FOR REVIEW AND APPROVAL PRIOR TO ORDERING AND INSTALLATION. 12. ALL SHEET METAL AND FLASHING SHALL COMPLY WITH SMACNA ARCHITECTURAL SHEET METAL. 13. CONTRACTOR SHALL SUBMIT TO ARCHITECT ALL MARKED UP FIELD CHANGES FOR THE PRODUCTION OF RECORD DRAWINGS AND SPECIFICATIONS. 14. CONTRACTOR SHALL SUBMIT A LIST OF PUNCHLIST ITEMS TO THE ARCHITECT FOR FINAL REVIEW AND BUILDING PUNCH. CONTRACTOR SHALL COMPLETE PUNCHLIST ITEMS PREPARED BY THE OWNER AND ARCHITECT. 15. CONTRACTOR SHALL SUBMIT WITHIN 10 DAYS OF NOTICE TO PROCEED (NTP) A CONSTRUCTION SCHEDULE WITH START DATE, FINISH DATE, WORK HOURS AND CONSTRUCTION PHASING PLAN IF REQUIRED AND CONSTRUCTION HOURS TO THE OWNER FOR REVIEW AND APPROVAL. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL APPLICABLE PERMITS AND ADDITIONAL COPIES. 21. CONTRACTOR SHALL REVIEW WITH OWNER THEIR SAFETY/PROTECTION PLAN, STAGING PLAN, CLEANUP PLAN, STAFFING, PORTABLE RESTROOM PLAN, AND SECURITY OF MATERIALS PLAN AT THE PRE -CONSTRUCTION MEETING. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE RELATED SAFETY REQUIREMENTS. 22. CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES AND REQUEST LOCATES PRIOR IF DIGGING IS REQUIRED OR ANY UTILITY WORK IS REQUIRED. 23. THE SITE IS A SMOKE FREE AND DRUG FREE SITE. THERE SHALL BE NO SMOKING WITHIN 25 FEET OF ANY BUILDING ENTRY/EXIT OR WINDOW. 24. CONTRACTOR SHALL COORDINATE PAYMENT, PAYMENT SCHEDULE, RETAINAGE AND CLOSEOUT WITH THE OWNER. 25. CONTRACTOR SHALL PROTECT ALL MATERIALS AND CONSTRUCTION FROM WEATHER, VANDELISM AND THEFT. STANDARD UTILITY NOTES 1. ALL UNDERGROUND UTILITIES MUST BE IN PLACE, TESTED AND INSPECTED AS REQUIRED PRIOR TO BASE AND SURFACE CONSTRUCTION. 2. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN AREAS OF BURIED UTILITIES AND SHALL PROVIDE AT LEAST 48 HOURS NOTICE TO THE VARIOUS UTILITY COMPANIES IN ORDER TO PERMIT MARKING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES IN ADVANCE OF CONSTRUCTION, BY CALLING FLORIDA SUNSHINE STATE ONE CALL CENTER OF FLORIDA, INC. AT 1-800-432-4770. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY "SUNSHINE" FORTY-EIGHT (48) HOURS PRIOR TO ANY CLEARING OF CONSTRUCTION TO IDENTIFY ALL UTILITY LOCATIONS. 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL UTILITY COMPANIES TO DISCONNECT OR REMOVE THEIR FACILITIES PRIOR TO REMOVING OR DEMOLISHING ANY EXISTING STRUCTURES FROM THE SITE. ALL UTILITIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, THE FOLLOWING SHOULD BE CONTACTED BY THE CONTRACTOR: 1. GAS 2. TELEPHONE 3. CABLE 4. POWER 5. CITY/COUNTY WATER AND SEWER 6. CITY/COUNTY/STATE TRAFFIC SIGNAL UTILITY (FIBER, HARDWIRE TRAFFIC SIGNAL INTERCONNECT) 4. THE LOCATION OF ALL EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR ACCURACY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATIONS OF THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING ANY UNDERGROUND UTILITY, WHETHER SHOWN ON THE PLANS OR LOCATED BY THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFACE WITH THE PROPOSED CONSTRUCTION SHALL BE RELOCATED BY THE RESPECTIVE UTILITY COMPANIES AND THE CONTRACTOR SHALL COOPERATE WITH THE UTILITY COMPANIES DURING RELOCATION OPERATIONS. ANY DELAY OR INCONVENIENCE CAUSED TO THE CONTRACTOR BY THE VARIOUS UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED. SAFETY NOTES 1. DURING THE CONSTRUCTION AND/OR MAINTENANCE OF THIS PROJECT, THE CONTRACTOR SHALL COMPLY WITH REGULATIONS. THE CONTRACTOR OR HIS REPRESENTATIVE SHALL BE RESPONSIBLE FOR THE CONTROL AND SAFETY OF THE TRAVELING PUBLIC AND THE SAFETY OF ITS PERSONNEL. LABOR SAFETY REGULATIONS SHALL BE AS SET FORTH BY OSHA IN THE FEDERAL REGISTER OF THE DEPARTMENT OF LABOR. 2. THE MINIMUM STANDARDS AS SET FORTH IN THE CURRENT EDITION OF THE STATE OF FLORIDA, MANUAL ON TRAFFIC CONTROL AND SAFE PRACTICES FOR STREET AND HIGH WAY CONSTRUCTION, MAINTENANCE AND UTILITY OPERATIONS SHALL BE FOLLOWED IN THE DESIGN APPLICATION, INSTALLATION, MAINTENANCE, AND REMOVAL OF ALL TRAFFIC CONTROL DEVICES, WARNING DEVICES, AND BARRIERS NECESSARY TO PROTECT THE PUBLIC AND WORKERS FROM HAZARDS WITHIN THE PROJECT LIMITS. 3. ALL TRAFFIC CONTROL MARKINGS, FLAGGERS, AND DEVICES SHALL CONFORM TO THE PROVISIONS SET FORTH IN THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES PREPARED BY THE U.S. DEPARTMENT OF TRANSPORTATION FEDERAL HIGHWAY ADMINISTRATION. 4. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH AND ENFORCE ALL APPLICABLE SAFETY REGULATIONS. THE ABOVE INFORMATION HAS BEEN PROVIDED FOR THE CONTRACTOR'S INFORMATION ONLY AND DOES NOT IMPLY THAT THE OWNER OR ENGINEER WILL INSPECT AND/OR ENFORCE SAFETY REGULATIONS. CLEARING AND SITE PREPARATION NOTES CONTRACTOR SHALL CLEAR AND GRUB ONLY THOSE PORTIONS OF THE SITE NECESSARY FOR CONSTRUCTION. CONTRACTOR SHALL REMOVE ALL TRASH AND UNSUITABLE DEBRIS WITHIN THE CONSTRUCTION AREA AND PROPERLY DISPOSE OF OFFSITE. ALL CONSTRUCTION DEBRIS AND OTHER WASTE MATERIAL SHALL BE DISPOSED OF IN ACCORDANCE WITH APPLICABLE REGULATIONS. CONTRACTOR TO OBTAIN ALL NECESSARY PERMITS AND APPROVALS PRIOR TO REMOVING ANY EXISTING STRUCTURES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL UTILITY COMPANIES TO DISCONNECT OR REMOVE THEIR FACILITIES PRIOR TO REMOVING OR DEMOLISHING ANY EXISTING STRUCTURES FROM THE SITE. ALL TREE ROOTS EXISTING WITHIN APPROVED IMPROVEMENT AREAS AND ORIGINATING FROM A PROTECTED TREE, SHALL BE SEVERED CLEAN AT THE LIMITS OF THE WORK AREAS WHEREVER THEY ARE WITHIN 20' OF A TREE TO BE PRESERVED. LOCATE ALL EXISTING UTILITIES. ALL EXISTING UTILITIES SHALL BE CAPPED AND PRESERVED FOR FUTURE TIE-INS. CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY ALL UTILITY AGENCIES HAVING JURISDICTION PRIOR TO CONSTRUCTION. CONTRACTOR SHALL COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS REGARDING POLLUTION CONTROL OF STORED MATERIALS, FUEL, EQUIPMENT, OR OTHER HAZARDOUS MATERIALS USED ON SITE. ALL CONSTRUCTION DEBRIS SHALL BE STOCKPILED IN MANNER THAT DOES NOT CAUSE SOIL, AIR, OR WATER POLLUTION ON SITE UNTIL DISPOSED OF IN A PROPER MANNER. CONTRACTOR SHALL COMPLY WITH SEDIMENT DISCHARGE CONTROL TO OFFSITE SO THAT WATER QUALITY COMPLIES WITH LOCAL, STATE, AND FEDERAL TURBIDITY PARAMETERS. CONTRACTOR SHALL SPRINKLER OR OTHERWISE APPLY WATER TO AFFECTED CONSTRUCTION AREA TO CONTROL BOTH SIGNIFICANT WIND EROSION AND FUGITIVE DUST. SITE NOTES LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES, AND OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. THE CONTRACTOR SHALL VERIFY THE LOCATIONS, ELEVATIONS, AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES AFFECTING THIS WORK PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL CHECK PLANS FOR CONFLICTS AND DISCREPANCIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE OWNER'S ARCHITECT OF ANY CONFLICT BEFORE PERFORMING ANY WORK. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING FACILITIES, ABOVE OR BELOW GROUND, THAT MAY OCCUR AS A RESULT OF THE WORK PERFORMED BY THE CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BECOME FAMILIAR WITH THE PERMIT AND INSPECTION REQUIREMENTS OF THE VARIOUS GOVERNMENTAL AGENCIES. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION, AND SCHEDULE INSPECTIONS ACCORDING TO AGENCY INSTRUCTION. ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF THE VARIOUS GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER THE WORK. ,aT LEAST 3 WORKING DAYS PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND APPROPRIATE AGENCIES AND SUPPLY THEM WITH ALL APPROVED SHOP DRAWINGS, THE CONTRACTOR'S NAME, STARTING DATE, PROJECTED SCHEDULE, AND OTHER INFORMATION AS REQUIRED. ANY WORK PERFORMED PRIOR TO NOTIFYING THE ENGINEER AND/OR WITHOUT AGENCY INSPECTOR PRESENT MAY BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE :;ONTRACTOR'S EXPENSE. ^,'jHK PERFORMED UNDER THIS CONTRACT SHALL INTERFACE SMOOTHLY ;,�!'TH OTHER WORK TO BE PERFORMED ON SITE BY OTHER CONTRACTORS AND UTILITY COMPANIES. IT VVILL BE NECESSARY FOR THE CONTRACTOR TO COORDINATE AND SCHEDULE ACTIVITIES, WHERE NECESSARY, WITH OTHER CONTRACTORS AND UTILITY COMPANIES. ALL DISTURBED AREAS WITHIN PUBLIC RIGHT-OF-WAY ARE TO BE RESTORED TO ORIGINAL CONDITION OR BETTER. REPAIR AND REPLACEMENT OF ALL PRIVATE AND PUBLIC PROPERTY AFFECTED BY THIS WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN EXISTING CONDITIONS BEFORE COMMENCING CONSTRUCTION WORK UNLESS SPECIFICALLY EXEMPTED BY THE PLANS. ADDITIONAL COSTS ARE INCIDENTAL TO OTHER CONSTRUCTION AND NO EXTRA COMPENSATION IS TO BE ALLOWED. ROOF NOTES: AFF ABOVE FINISH FLOOR ACOUST ACOUSTICAL ADJ ADJUSTABLE A/C AIR CONDITIONING ^ ALT ALTERNATE DRAWING TITLEBAR: ALUM ALUMINUM AN ANODIZED SCALE: ANCH ANCHOR APPROX APPROXIMATE NORTH ARROWS: ARCH ARCHITECT/ARCHITECTURAL N AE ARCHITECT -ENGINEER / ASPH ASPHALT REFER TO DRAWING ID @ AT ATT ATTACH(ED) AUTO AUTOMATIC BUILDING / WALL SECTION AVG AVERAGE REFERENCE: BD BOARD BLDG BUILDING BLK BLOCK E BLKG BLOCKING 4 A401 2 EXTERIOR / INTERIOR BM BEAM ELEVATIONS BRG BEARING 3 BOT BOTTOM BO BOTTOM OF ? LEVEL LINE IN ELEVATIONS ? AND SECTIONS CAB CABINET CPT ,CARPET CLG CEILING ? CEM CEMENT ? DETAIL REFERENCE CL CENTER LINE ? CLR CLEAR CT CERAMIC TILE CLO CLOSET COL COLUMN REFER TO THIS DRAWING ID CONC CONCRETE CMU CONCRETE MASONRY UNIT CONF CONFERENCE CONTT CONSTRUCTION CJ CONTROL JOINT J COLUMN LINE GRID INDICATOR CONT CONTINUOUS CORR CORRIDOR CF CUBIC FEET BREAK LINE CY CUBIC YARD DEG DEGREE DET DETAIL DIAG DIAGONAL ? ROOM INDICATOR DIA DIAMETER ROOM NUMBER AND DIM DIMENSION ROOM SPACE AREA DIV DIVISION DN DOWN DR DOOR DOOR IDENTIFICATION DS DOWNSPOUT J DWG DRAWING EA EACH E WINDOW/LOUVER TYPE E EAST IDENTIFICATION EWC ELECTRIC WATER COOLER ELECT ELECTRICAL WALL TYPE IDENTIFICATION EL ELEVATION EQ EQUAL ALIGN EQUIP EQUIPMENT EXIST EXISTING NOTE: INDICATES FINISHED EXP EXPANSION SURFACES SHALL ALIGN EJ EXPANSION JOINT EXT EXTERIOR FO FACE OF E DR�WING KEYNOTE FOF FACE OF FINISH FT FOOT/FEET FIN FINISH FF FINISH FLOOR FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FIXT FIXTURE FLEX FLEXIBLE FLR FLOOR FD FLOOR DRAIN FLOUR FLUORESCENT FTG FOOTING FDN FOUNDATION FURN FURNITURE/FURNISHINGS REFERENCES AND STANDARDS AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) - ANNUAL BOOK OF ASTM STANDARDS 1. ASTM A 653/A 653M - STANDARD SPECIFICATION FOR STEEL SHEET, ZINC COATED (GALVANIZED) OR ZINC -IRON -ALLOY -COATED GALVANNEALED BY THE HOT -DIP PROCESS 2. ASTM B 209 - STANDARD SPECIFICATION FOR ALUMINUM AND ALUMINUM ALLOY SHEET AND PLATE 3. ASTM B 370 - STANDARD SPECIFICATION FOR COPPER SHEET AND STRIP FOR BUILDING CONSTRUCTION 4. ASTM D 3018 - STANDARD SPECIFICATION FOR CLASS A ASPHALT SHINGLES SURFACED WITH MINERAL GRANULES 5. ASTM D 3161 - STANDARD TEST METHOD FOR WIND -RESISTANCE FOR ASPHALT SHINGLES (FAN -INDUCED METHOD) 6. ASTM D 3462 - STANDARD SPECIFICATION FOR ASPHALT SHINGLES MADE FROM GLASS FELT AND SURFACED WITH MINERAL GRANULES 7. ASTM D 4586 - STANDARD SPECIFICATION FOR ASPHALT ROOF CEMENT, ASBESTOS -FREE 8. ASTM D 7158 - STANDARD TEST METHOD FOR WIND -RESISTANCE OF SEALED ASPHALT SHINGLES (UPLIFT FORCE/ UPLIFT RESISTANCE METHOD) 9. AC438-1011-R1 - NEW ACCESS CRITERIA FOR ALTERNATIVE ASPHALT ROOFING SHINGLES 10. ASTM E903 - STANDARD TEST METHOD FOR SOLAR ABSORPTANCE, REFLECTANCE AND TRANSMISSION OF MATERIALS USING INTERGRATED SPHERES. UNDERWRITERS LABORATORIES (UL)- ROOFING SYSTEMS AND MATERIALS GUIDE(TFWZ.R21) 11. UL 790 -TESTS FOR FIRE RESISTANCE OF ROOF COVERING MATEIALS 12. UL 997 - WIND RESISTANCE OF PREPARED ROOF COVERING MATERIALS 13. UL 2218 - IMPACT RESISTANCE OF PREPARED ROOF COVERING MATERIALS 14. ASPHALT ROOFING MATERIALS ASSOCIATION (ARMA) 15. SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC. (SMACNA) - ARCHITECTURAL SHEET METAL MANUAL SHINGLES 1. SELF SEALING. GRANULE SURFACED, ASPHALT SHINGLE WITHA STRONG FIBERGLASS REINFORCED MICRO WEAVE CORE AND STAINGUARD PROTECTION, WHICH PREVENTS PRONOUNCED DISCOLORATION FROM BLUE-GREEN ALGAE THROUGH FORMULATION/ UNIQUE BLENDS OF GRANULES. ARCHITECTURAL LAMINATE STYLING PROVIDES A WOOD SHAKE APPEARANCE WITH A 5 5/8 INCH EXPOSURE, UL 790 CLASS A RATED WITH UL 997 WIND RESISTANCE LABEL; ASTM D 7158 CLASS H; ASTM D 3161, TYPE 1; ASTM D 3018, TYPE 1; ASTM D 3462; AC438 COMPLIANT; CSA 123.5-98; DADE COUNTY APPROVED, FLORIDA BUILDING CODE APPROVED. COLOR SELECTION BY OWNER. LEAK BARRIER 1. SELF -ADHERING, SELF SEALING, BITUMINOUS LEAK BARRIER SURFACE WITH FIRE, SKID -RESISTANCE GRANULES. APPROVED BY UL, DADE COUNTY, ICC AND STATE OF FLORIDA 2. SELF -ADHERING, SELF SEALING, BITUMINOUS LEAK BARRIER SURFACE WITH A SMOOTH POLYETHYI.ENE FILM. APPROVED BY UL, DADE COUNTY, ICC AND STATE OF FLORIDA SHINGLE UNDERLAYMENT 1. PREMIUM, WATER REPELLANT, BREATHER TYPE NON -ASPHALTIC UNDERLAYMENT. UV STABILIZED POLYPROPYLENE CONSTRUCTION. MEETS OR EXCEEDS ASTM D226 AND D4869. APPROVED BY DADE COUNTY AND FLORIDA BUILDING CODE 2. #30 ROOFING UNDERLAYMENT - WATER REPELLANT BREATHER TYPE CELLULOSE FIBER BUILFING PAPER. MEETS OR EXCEEDS ASTM D4869, TYPE IL CONSTRUCTION ADMINISTRATION NOTES: 1. OWNER/OWNER REP/ OWNER CM HAS THE RIGHT TO STOP WORK, CARRY OUT OR SUBCONTRACT OR SELF PERFORM WORK. SELF PERFORM WORK OR OWNER SUBCONTRACTOR SHALL BE DEDUCTED FROM THE CONTRACTOR SUM FOR ALL WORK NOT COMPLETED BY CONTRACTOR, 2. FORMAL LINES OF COMMUNICATION OF THE CONTRACTOR SHALL BE TO THE OWNER REP/ OWNER CM OR ARCHITECT 3. CONTRACTOR/SUBCONTRACTORS SHALL PERFORM AND COMPLETE WORK AS REQUIRED BY THE: (OWNER AS SHOWN IN THESE CONTRACT DRAWINGS AND SPECIFICATIONS 4. CONTRACTOR/SUBCONTRACTORS PROGRESS PAYMENT SHALL BE PAID UPON COMPLETION OF WORK BASED ON SUBMITTAL OF RECEIPTS WITH APPLICATIONS FOR PAYMENT AND DOCUMENTATIONS OF COMPLETED WORK TO BE APPROVED BY OWNER REP/ OWNER CM/ ARCHITECT 5. CONTRUCTION SUBSTITUTIONS, MODIFICATIONS AND CHANGES SHALL BE EVALUATED BY THE OWNER REP/ OWNER CM/ ARCHITECT BEFORE ANY WORK IS PERFORMED 6. OWNER SHALL MAINTAIN A RETAINAGE OF 10% OF THE CONTRACT SUM UNTIL SUBSTANTIAL COMPLETION 7. CONTRACTOR/ SUBCONTRACTORS SHALL PROVIDE THE OWNER AND ARCHITECT A PUNCH LIST AT SUBSTANTIAL COMPLETION 8. RETAINAGE SHALL BE RELEASED TO CONTRACTOR/ SUBCONTRACTORS AT THE COMPLETION OF ALL PUNCH LIST ITEMS 9. CONTRA TOR/SUB SUBCONTR ACTORS CO RS SHALL PROVIDE MARKED AS BUILT DRAWINGS SHOWING ANY IN FIELD CHANGES TO OWNER REP/ OWNER CM AND ARCHITECT 10. CONTRACTOR/ SUBCONTRACTORS SHALL PROVIDE DELIVER TO THE OWNER ALL WARRANTIES AND MAINTENANCE MANUALS 11. CONTRACTOR SHALL PROVIDE A COMPLETE CONSTRUCTION SCHEDULE COORDINATED WITH THE OWNER'S SUBSTANTIAL COMPLETION DATE. CONTRACTOR/ SUBCONTRACTORS SHALL COMPLY AGREED OWNER'S LIQUIDATED DAMAGES FOR COSTS INCURED FOR NOT COMPLETING THE PROJECT ON TIME 12. CONTRACTOR SHALL SCHEDULE A PRE -CONSTRUCTION MEETING WITH THE OWNER REP/ OWNER CM OR ARCHITECT. CONTRACTOR SHALL SCHEDULE REGULAR WEEKLY OR BI- WEEKLY CONSTRUCTION SITE MEETINGS WITH OWNER REP/ OWNER CM 0[1 ARCHITECT TO REVIEW CONSTRUCTION 13. CONTRACTOR SHALL PROVIDE A COMPLETE CONSTRUCTION COST AND SCIEDULE OF VALUES BROKEN DOWN BY CSI DIVISIONS GAL GALLON GALV GALVANIZED GA GAUGE GC GENERAL CONTRACTOR GJ GUTTER JOINT GL GLASS/GLAZING GOVT GOVERNMENT GYP GYPSUM GWB GYPSUM WALL BOARD HC HOLLOW CORE HM HOLLOW METAL HDW HARDWARE HD WD HARDWOOD HD HEAD HVAC HEATING, VENTILATING AND AIR CONDITIONING HT HEIGHT HORIZ HORIZONTAL HR HOUR INCH INCH INCL INCLUDED INFO INFORMATION ID INSIDE DIMENSION INSUL INSULATION INT INTERIOR 1. 1. INVERT IN 1.0. INVERT OUT JAN JANITOR JT JOINT JST JOIST LAB LABORATORY LAM LAMINATE LAV LAVATORY L LENGTH LT LIGHT LF LINEAL FEET/FOOT LVR LOUVER MFR NkNUFACTURER MO MASONRY OPENING MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING MTL METAL MM MILLIMETER MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS NAT NATURAL NOM NOMINAL N NORTH NA NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE NO NUMBER OC C J CENTER OFF OFFICE OD C 1TSIDE DIAMETER OH C'POSITE HAND OHD OVERHEAD OPNG OPENING OPP OPPOSITE PTD PAINTED PR PAIR PERF PERFORATED PERIM PERIMETER PLAS PLASTER P LAM PLASTIC LAMINATE PLYWD PLYWOOD PT POINT LB OR # POUND PSF P )UND PER SQUARE FOOT PSI POUND PER SQUARE INCH PC PRECAST PT PRESSURE TREATED PL PROPERTY LINE PREFAB PREFABRICATED PREFIN PREFINISHED TERMITE PROTECTION QTY QUANTITY QT QUARRY TILE R RADIUS RCP REFLECTED CEILING PLAN REC RECESSED REF REFERENCE REINF REINFORCE(D)(ING) REBAR REINFORCING BAR RESIL RESILIENT REQD REQUIRED RA RETURN AIR REV REVISE(SION)(D) RD ROOF DRAIN RM ROOM RO ROUGH OPENING SCHEID SCHEDULE SCR SCREEN SECT SECTION SHT SHEET SMACNA SHEET METAL & AIR CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION SIM SIMILAR SC SOLID CORE S STAIN SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL SSM SOLID SURFACE MATERIAL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SYS SYSTEM TER TERRAllO THK THICK TLT -OILET T&G TONGUE AND GROOVE TO TOP OF TD TOWEL DISPENSER TDR TOWEL DISPENSER/RECEPTACLE TR TOWEL RECEPTACLE T TREAD TYP TYPICAL UNFIN UNFINISHED UL UNDERWRITERS LABORATORIES LINO UNLESS NOTED OTHERWISE VAR VARIES VTR VENT THRU ROOF VERT VERTICAL VEST VESTIBULE VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD VWC VINYL WALL COVERING VWM VERIFY WITH MANUFACTURER WT WEIGHT WH WATER HEATER W/ WITH W/o WITHOUT WD WOOD YD YARD 1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED.THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. 2. CONDENSATE AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST V-0" AWAY FROM BUILDING SIDE WALLS. 3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN V-0" OF THE BUILDING SIDE WALLS 4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, THE DISTANCE BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN SIX INCHES. EXCEPTION: PAINT OR DECORATIVE CEMENTOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. 5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACK FILL IS COMPLETE. 6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED FOR FORMED. 7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT, 8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. 9. CONCRETE OVER POUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT. 10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN V-0" OF THE STRUCTURE SIDE WALLS. 11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING AND LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED. 12. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL. 1.13 COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES" 13. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN V-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. United Pentecostal Fire Ministries NEW CBS BUILDING 202 E MIDWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com 2� 17' 2-I AUDIE ROBINSON, AR0094296 No. Description Date GEN NOTES, SYMB, ABBREVIATIONS Project number UPFM001 Date 04/17/2021 Drawn by MN Checked by AR A01_ Scale 202 E M I DWAYROAN FORT PIERCE FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com AUDIE ROBINSON, AR0094296 No. Description Date I REVIIEW.E no $ a-�� �N � � sirs =tre' ti9ha ''trtw+, ACCESSIBILITY REQUIREMENTS Project number UPFM001 Date 04/17/2021 Drawn by MN Checked by AR Scale 7 N O N O N LO W. ua _ Y 0�y LL to a b Handrail Handrail P,�P'E�i T'�.� TRASH SAS S�1[TA#��'' NAPKIN/ � U AND SEAT COVE fhl HAi*! R NAPKIN NAPKIN LAVATORY TAMPON VENDOR HAIR DRYER DISPENSER RECEPTACLE DISPENSER DISP ENSER DISPOSAL & TRASH \ RECEPTACLE VISUAL DEVICE W 0. -- OUTLET� LL 0 (c ) �a) �d ) CUP �iCRov16 PAPER TOWELPAPER TOWEL 'Grab Bar Handrail VENDING Handrail -or�R ��N DISPENSER DISPENSER RECEPTACLE MACHINE 202 E MIDWAY "•A FLORIDAFORT PIERCE, SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com Z'I►LI AUDIE ROBINSON, AR0094296 No. Description Date Y i"AL i " fCl k., C �ma� �'�As� Lam' T 1 -, ACCESSIBILITY REQUIREMENTS Project number UPFN1001 Date 04/17/2021 Drawn by MN Checked by AR A03 Scale NOTES: CONSTRUCTION TYPE VB NON -SPRINKLER 1. CHURCH SHALL CONFORM TO MINIMUM LEGAL DESCRIPTION: LOTS 21 AND 22, BLOCK 38, INDIAN RIVER ESTATES BUILDING CLASSIFICATION (302): ASSEMBLY, GROUP A-3 (RELIGIOUS) STANDARDS OF THE FBC. UNIT 4, ACCORDING TO PLAT THEREOF AS RECORDED IN PB 1 D, PAGE 48 OF THE PUBLIC RISK CATEGORY: PUBLIC ASSEMBLY, SEATING < 300 PERSONS ...... II BUILDING DEPARTMENT PRODUCT APPROVAL AFFIDAVIT 2. EMERGENCY DISCHARGE RECORDS OF ST. LUCIE COUNTY FLORIDA DESIGN WIND SPEED: FIG. 1609A/CAT II .......................................... 160MPH - LIGHTING/ILLUMINATION WITH BATTERY EXPOSURE............................................................................................. "B" OPENING / ITEM PRODUCT MODEL MFGR NCTA PRESSURE PRODUCT BACKUP SHALL BE PROVIDED. VELOCITY PRESSURE CALCULATED 41.7PSF - ADDRESS: 202 EAST MIDWAY ROAD (ST. LUCIE CTY) FORT PIERCE, FLORIDA PRESSURE(CALCULATED) ••••••••••••••••••••••••••�•••••••••••••••••• - 3. ALL EXIT DOORS SHALL HAVE PANIC SITE / AREA: 43,529 GSF (0.99 Ac) IMPORTANT USE FACTOR.................................................................. "1.D" ROOFING METAL ROOFING MECHANICAL TRI COUNTY METALS FL#4595.6 -123.5 HARDWARE. SEE HARDWARE SPEC INTERNAL PRESSURE COEFFICIENT BUILDING AREA: NEW CBS STRUCTURE ...........................3931 GSF SEAM LOK 4. PROVIDE HOOD FIRE SUPPRESSION SYSTEM IN COVERED DROP-OFF.............................361 GSF ENCLOSURE STRUCTURE ..................................................... (0.75/ .B3) KITCHEN. CONTRACTOR SHALL PULL UNCOVERED WALKWAY ........................360 GSF PARTIALLY ENCLOSED........................................................ (1.06/-1.15) SOFFIT ENG. WOOD LP BUILDING FL#9103.1 N/A SEPARATE PERMIT. SEE TOTAL 4652 GSF ASCE CATEGORY................................................................................. PUBLIC ASSEMBLY SOLUTIONS WIND PROTECTION: STEEL SHUTTERS HI IMPACT GLAZING DOORS EXTERIOR DOOR CONTOURS STEEL, JELD WEN FL#11136.6 +66/-66 ap STEEL EDGE ACTUAL FIXED SEAT: NOTE: PLUMBING BERTOLINI, MILLENNIA CONTRACTOR TO ENSURE THAT THE EXTERIOR SLAB SURFACE ELEVATION WINDOWS SINGLE HUNG V1 / SERIES 70 SILVER LINE BLDG. FL# 14911.5 +55/-60 END SEATS & EVERY OTHER SEAT AND INTERIOR FLOOR LEVEL AT DOOR OPENINGS SHALL NOT EXCEED 1/2" PRODUCTS CORP. MALE =123 (1/125WC & 1/200LAV) = 1 WC, LAV 1 SHALL BE BOLTED TO THE FLOOR & El DIFFERENCE IN LEVEL CHANGE AND THE ELEVATION ON BOTH FLOOR FEMALE =123 (1/65WC & 1/200LAV) = 2 WC, LAV 1 ALL SEATS INTERLOCK TOGETHER SURFACES SHALL BE MAINTAINED FOR A DISTANCE NOT LESS THAN THE WALL LOUVER VENT 5" DEEP ALUM. SP537DC INDUSTRIAL NOA 18-0222.07 +120/-120 TOTAL REQUIRED: 3 WC, LAV 2, FOR EACH ROW OF SEATS. FASTENED WIDTH OF THE WIDEST DOOR LEAF. LOUVER LOUVERS, INC. 1 DRINKING FOUNTAIN, 1 SERVICE SINK W/ 1"HEAVY DUTY ANGLES W/ 1/2" 1' - 5" PROVIDED: 4 WC, 1 URINAL, 5 LAV TRI-WING BOLT OR SIM. TAMPER RESIST. United Pentecostal 1 SERVICE SINK, 1 DRINKING FOUNTAIN F ST N R. Fire Ministries INTERIOR FIINISHES: ALL INTERIOR FINISHES SHALL BE NOA / FLORIDA PRODUCT APPROVAL GENERAL NOTES EXITS CLASS A RATED FBC 1005.3.2, w 1. THE CONTRACTOR SHALL COMPLY WITH THE CURRENT VERSION OF THE FLORIDA PRODUCT APPROVAL EXIT 1 = 36"/.2 = 180 PERSONS STATUTE 553.8425 FOR ALL EXTERIOR BUILDING ENVELOPE COMPONENTS AND SYSTEM PRODUCTS AS EXIT 2 - 36/.2 - 180 PERSONS n_ INDICATED IN THE CONSTRUCTION DOCUMENTS. o TOTAL EGRESS = 360 PERSONS xQ n 2. THE CONTRACTOR SHALL PROVIDE WIND DESIGN ANALYSIS FOR ALL FIXED ATTACHMENT STRUCTURES AND COMPONENTS, IN ACCORDANCE WITH FLORIDA STATUTE 553.8425, LOCAL PRODUCT APPROVAL. 3 AISLE WIDTH = (AISLE 1- 45") 225 PERSONS +Cl 3. THE CONTRACTOR SHALL PROVIDE CERTIFICATE OF PRODUCT APPROVAL AND/OR SIGNED AND SEALED SHOP (AISLE 3 - 45") 225 PERSONS + (AISLE 1- 60") 300 ¢ Q DRAWINGS AND WIND DESIGN ANALYSIS BY AN ACTIVE FLORIDA REGISTERED PROFESSIONAL ENGINEER, FOR PERSONS=150"/.2=750 PERSONS. EXIT 2 - 36/.2 - EXIT 1 - 36"/.2 - ALL FIXED ATTACHMENT STRUCTURES AND COMPONENTS LISTED HEREIN AND AS INDICATED IN THE CONSTRUCTION DOCUMENTS, AND MUST ALSO CERTIFY INDEPENDENCE FROM THE PRODUCT 180 PERSONS 180 PERSONS MANUFACTURER PRIOR TO THE BID OPENING. 4. IF THERE IS A FLORIDA PRODUCT APPROVAL SUBSTITUTIONS DEVIATING FROM THE CONTRACT DOCUMENTS, NEW CBS BUILDING ■ ■ ■-77'■ ■ ■ ■ IT MUST BE SUBMITTED TO THE ENGINEER/ARCHITECT FOR REVIEW AND APPROVAL. I,1\ am ,33� 5. THE CONTRACTOR SHALL INCLUDE IN THEIR BID ALL ASSOCIATED COSTS TO PROVIDE A REGISTERED FLORIDA rYY " MINISTRY RM. STRUCTURAL ENGINEER (PE) TO EVALUATE PROJECT EXTERIOR BUILDING ENVELOPE COMPONENTS, FOR AISLE 1 = 45"/.2" _ 66 FIXED SEATS WHICH THE FLORIDA BUILDING CODE DOES NOT HAVE ESTABLISHED STANDARD EVALUATION METHODS. THE VESSTRY SD I 225 PERSONS �'' -109 / ' ENGINEER'S EVALUATIONS SHALL BE A COMPLETE DESCRIPTION OF THE COMPONENT ASSEMBLY AND 11 _ _ _ _ _ I / , 00, METHOD OF ANALYSIS, SIGNED AND SEALED, INCLUDING ALL EVALUATION CALCULATIONS 1 OCC.I ' 202 E MIDWAY ROAD _ o I it I / ' ' 1 O OCC. GENERAL FIRE EXTINGUISHER NOTES 9000 FORT PIERCE .O C p I 1. CONTRACTOR SHALL VERIFY EXISTING FIRE EXTINGUISHER LOCATIONS & PROVIDE ADDITIONAL F.E.C. TO COMPLY W/ CURRENT CODES & LOCAL JURISDICTION. FLORIDA 2. CONTRACTOR SHALL PROVIDE A DESCRIPTION AND LIST OF ALL LIFE SAFETY PROVISIONS DURING CONSTRUCTION TO COMPLY WITH NFPA 1 CHAPTER 16 TO THE FIRE MARSHAL AND COMPLETE ALL REQUIRED AHJ DOCUMENTS. 3'- 6" PLATFORM: FBC 1004 1 ' I 3. CONTRACTOR SHALL PROVIDE ALL FIRE EXTINGUISHERS, FIRE SUPPRESSION, ALARMS, STROBES AND 164SF/15 = 12 OCC. 1 I CONNECTIONS THAT ARE NECESSARY TO COMPLY W/ THE FIRE MARSHAL'S AND AHJ'S LIFE SAFETY 00 REQUIREMENTS FOR ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 1 4. FIRE EXTINGUISHER SHALL BE MULTIPURPOSE DRY -CHEMICAL TYPE IN STEEL CONTAINER: UL-RATED 4-A:60- B:C, 10-LB NOMINAL CAPACITY, WITH MONOAMMONIUM PHOSPHATE -BASED DRY CHEMICAL IN ENAMELED- o I L - - - - '" - - J 47 STEEL CONTAINER. CONTRACTOR SHALL INSTALL WITH MANUFACTURER'S STANDARD STEEL MOUNTING MUSICIAN I I BRACKETS. PROVIDE IDENTIFYING BRACKET SIGN -MOUNTED WITH THE WORDS "FIRE EXTINGUISHER" IN SAVAN NAPU B, INC. 1 OCC. BREAK RED LETTER DECALS APPLIED TO MOUNTING SURFACE. ORIENTATION: VERTICAL, ABOVE EXTINGUISHER. j I _ _ _ _ _ _ _ _ _ _ _____ __ _ i 1 88 / / CONFORM WITH NFPA 10, PLACEMENT NFPA 1 AND 101. PO BOX 773553, OCALA FL 34477 I SD / 813-313-7707; savannapub@gmaiLcom ■ 60 - AISLE 2 = "/.2" = 300 PERSONS SANCTUARY OCC LOAD = 66+66+4+12+1+1+1=152 / NOTE: 1 0 SOUND ROOM CONTRACTOR SHALL BE RESPONSIBLE TO ACQUIRE PERMIT APPROVALS AND ALL ASSOCIATED COSTS: 1 SANCTUARY Ln a 1-07 / CONTRACTOR SHALL SUBMIT NOA / FLORIDA PRODUCT APPROVAL FOR ALL EXTERIOR BUILDING LLLJ 1 110 132 TOTAL SEAT / COMPONENTS AND INSTALLATION INSTRUCTIONS TO THE BUILDING DEPARTMENT. N 1 OCC. Do / 9 OCC. - - TYPICAL HANDICAP TOILET REQUIREMENT: (for reference) L- - - -- -- -� 0 1 5' - 0" ACCESSORY SIZE/MFGR# NOTE 7 7 1 I MIRROR WITH SHELF (24" X 32") #0605A-2030 FRAMED-40" TO SHELF MUSICIAN I TOWEL DISPENSER #0215 48"TOBOTTOM AUDIE ROBINSON, AR0094296 Q 1 OCC. I I SOAP DISPENSER #0371 40" TO BOTTOM 90.000 I MINISTRY RM TISSUE HOLDER #74022-SD 19"TO BOTTOM 106 GRAB BAR #3701-30 34" ABOVE F. FLOOR No. Description Date ■ HVAC _ GRAB BAR #3701-42 34" ABOVE F. FLOOR 1 Bldg. Dept Revision 03/25/2021 - _ � � COAT HOOK #0751 48" ABOVE F. FLOOR 112 11 OCC. ADA SIGNAGE (UNIVERSAL) 60" TO CENTERLINE (ON WALL) 3 Bldg. Dept Revision 7/02/2021 A/C PAD AH Sp 1 ♦ ` MOP RACK #8215A 60" ABOVE FIN, FUR, _w FIRE EXTINGUISHER: LARSON'S MANUFACTURING CO. FT LAUDERDALE FLORIDA PASSAGE 47� AISLE 3 = 45 /.2" = o ------------� � 113_' 225 PERSONS ` ■ 66 FIXED SEATS EXTINGUISHERS: MP10;10#, MULTIPURPOSE, UL RATING 4A-60B:C a o I 49 A/C PA (MOUNTED WHERE INDICATED ON PLAN) MOUNT UNITS SECURELY, SQUARE AND TRUE ■■1■■■ j■■■■■■ 45 MIN SMOKE DETECTORS SHALL BE REQUIRED IN ALL STORAGE ROOMS AND AT R/A DUCTS L - - - -- r---� I Si) ■ ♦ ♦ CHURCHBOARDCHURCH SECT. I Co / OCCUPANCY LOAD CALCULATION - ASSEMBLY - GROUP A3 ♦ 115 116 I / - j so ♦ I - - f - - - - - - - - - - ■ TOTAL OCCUPANT LOAD - 132 SANCTUARY (FIXED SEATS) NOTE: FBC 202 - ` ♦ 42 so / 20 (WHEELCHAIR, AV, VESTRY, RESTROOMS, MECHANICAL, ♦ 1 `� I O a PLATFORM, MUSCIAN STORAGE IS NOT TO BE / 48 INCIDENTAL MINISTRY RMS INCLUDED IN NET AREA -- TOILET 16 OCC. ♦ ♦ I 2 OCC. ■ I 45 MIN / MEN s� (15SF/PERSON TABLES/CHAIRS) CALCULATIONS OF _ - 114' I ■ 46 LOBBY (322 SF/7) OCCUPIED AREAS M=i ��_------------ - - -- :� 27' 45 MINA ♦ ♦ I I 45 MIN s� GRAND TOTAL = 246 OCCUPANTS ■ ♦ I ■ __ LIFE SAFETY SYMBOL LEGEND LIFESAFETY PLAN ♦ NOTE: LOGN FOR WARNING STENCIL ABV LAY -IN CLG. -WHITE 9" LETTERS - "FIRE WALL - ♦ ♦ I � LIGHTED EXIT SIGN W/ BATT 10/Y FIRE DEPT. MALTESE CROSS DO NOT PENETRATE" ♦ I FOR WD TRUSS ROOF ♦ LIGHTED EXIT SIGN W/ EMERGENCY PROVIDE SIGN FOR MAX. OCC. `L}� ADA MAX. SLOPE LIGHT 10/Y LOAD 148 @ SANCTUARY LOBBY KIMEMERGENCY LIGHTS W/ BATT 10Y 323 SF EM Project number UPFM001 SMOKE DETECTOR/ALARM Date 02/17/2021 $D 10 YEAR LITHIUM BATTERY UNIT Drawn by MN ■ a Checked by AR ■ ■ FIRE ALARM HC STROBE a LIFE SAFETY PLAN - N 1 49r DISTANCE IN FEET TO MARKED EXIT A05 1/4 =1-0 N N ■ ■ ■ ■ ■ 1 HR FIRE RATED WALL Scale 1 /4" = l'-O" 0 LO zo A. A00P CV bo 16'-4" 7' - 711 5'-4" HAM HB #6 VERT @ COR. CELL (TYP. @ ALL) ® l 3 2 14' - 3 1 /2" I A561 O VESSTRY MINISTRY RM. G 111 ------ - - - - ----- - - - - -- 109 DI I I . I I I I I I 90.00° O ' IC) I I 4 :�D 0 0 I I ( 0 0 I I cV REF. � , I 75 01: I I I ,I I I I I (.0 BREAK 3 G 3' 6° r , � i SOUND ROOM 108 01 ' 12' - 4" CLG. RIDGE SANCTOUARY 107 10' - 2" ■ i I I ' A106 2 I I I I I I I CV C4) I ' O d <E> d( I I TRUSS 1, 4I Q , I I I I ■ 4' 5" 14, 5" ----- ---- - - O HVAC f - - 56X66 112 Li A/C PAD --------- l . - MINISTRY RM ■ ------- 4'-0" 10'-4" 3'-8" 5'-6" 5'-6" 71- 5'-0" Of E o �� ■ xco `r' � O O CC4 CV 0 T N Ln T TECHNOLOGY NOTE: PROVIDE CABLES/CONDUIT AND WIRING FOR LARGE FLAT -SCREEN MONITORS IN SANCTUARY FOR DISPLAY OF CHURCH SERVICES, COORDINATE WITH OWNER FOR FINAL LOCATION AND CONNECTIONS GENERAL FLOOR PLAN NOTES 1. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD OR MASONRY UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLR" OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. DIMENSIONS OF EXTERIOR WALLS ARE TO THE OUTSIDE EDGE OF FOUNDATION BLOCK. 2. PROVIDE BRACING AS REQUIRED IN WALLS SUPPORTING CASEWORK AND RESTROOM ACCESSORIES, RAILINGS, ETC. ALL DOOR FRAMES ARE LOCATED 4" FROM ADJACENT WALL UNLESS NOTED OTHERWISE. 3. IF EXISTING DOOR DOES NOT COMPLY WITH ADA DOOR LEVER, IT SHOULD BE REPLACED. THE CONTRACTOR SHALL VERIFY EXISTING DOORS AND COORDINATE WITH HARDWARE SCHEDULE. 4. CONTRACTOR SHALL PROVIDE AN ELEVATED METAL SHELF TO ACCOMMODATE ELE0. WATER HEATER. COORDINATE WITH OWNER FOR TANKLESS SYSTEM IN LIEU OF TANK. 5, SLOPE FLOOR TO DRAIN IN ALL RESTROOMS. CENTER ALL FLOOR DRAINS WITHIN FLOOR TILE 6. FIELD VERIFY ALL DIMENSIONS. 7. SEAL ALL JOINTS BETWEEN DISSMILAR MATERIALS. 8. WHERE WALL TILE ABUTS HOLLOW METAL DOOR FRAME, DO NOT GROUT THE TILE JOINT ADJACENT TO THE FRAME APPLY SEALANT. INTERIOR PARTITION NOTES USE MOISTURE RESISTANT GYPSUM BOARDS AT RESTROOMS AND JANITORS AREA`:;; CD 1 A106 0 PASSAGE - z_ 1-1 —31 O o = - 4 (:4:) o JANITOR '— z CHURCH SECT. 45 MIN c� 3 `�' 0 1 0" `�' � �� CHURCH BOARD 116 DOOR00 IE WOMEN w RM - ■ co U 10 ---------------------------------------------- _ 115 0 ;� �, �_ G.B. PART'N T = _ d, 1 P 1\1",] (1 HR. RATED UL#419) ® �' TOILET F 114 E F - F _ ELE�H4�VAC — 4 r MEN O ® 10 O MTR OZL3 I f fi :p j I LOBBY N :.. • , - , ,., fi•- - , � ,.. • 101 CID „ 01 :.... - /y� is I „ fi a , fi. Q I , R v, , , e , , AI - DRIVE - Sim MSTI I w '" .. ,file I 10' WIDE CONC. WALK SLOPE TO DR 0'-8" 7'-2" 6'-6" 81- 10" 5,_6„ - — - 2' 0„ 5' 6" 5' 61' 2' 0„ DROP AWNING : I 1 - 0 1'-0" 14'-4" 14'-4" 3'-4" -- I I / L---------------------------------------- ------ r 7. 32'-Off 17'-Of' 26'-0" 75'-0" 10'-0" 19'-off FLOOR PLAN 1 /4" = 1'-0" United Pentecostal Fire Ministries NEW CBS BUILDING 202 E MIDWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com 'I v AUDIE ROBINSON, AR0094296 No. I Description Date 1 Bldg. Dept Revision 03/25/2021 2 Bldg. Dept Revision 5/04/2021 3 Bldg. Dept Revision 7/02/2021 FLOOR PLAN Project number UPFM001 Date 02/17/2021 Drawn by MN Checked by AR Al 01 Scale 1 /4" = 1 '-0" 2 a_ N N N N O N N r- TOP OF CMU BEARING WALL 12'-0" F.F.L. 01� 8., �_G,RCUND LEVEL 0'-Oil MALTESE CROSS PER FIRE DEPT. FOR WD. TRUSS ROOF STRUCTURE @ 64" AFF USE ENERGY STAR WINDOW UNITS (3 TOTAL) VINYL UNITS W/LOW E GLAZING ARCH HD (52" X 27.75") FL#14918 W/ 1X1 MULL COMPONENT TOP SASH (52" X 37.25") FL#14911 TYPE 70 SERIES /SH VINYL REQ.D WINDLOAD (+43/47) TYPE 70 SERIES / 5H VINYL � NORTH ELEVATION 11 CAST STONE CAP (2") PREFAB HALF -COLS (16"DIA) METALLIC FIN, EXTR. CER. TILES (6X6 W/DK GROUT (GREEN) BULLETIN BOARD GUTTER SYSTEM 1'-0" 16'-7" 15'-0" 1'-0" 1'-0" 19'-0" LO LO TOP OF CMU _ BEARING WALL 12'-0"-� CV F.F.L. o. _ .. GROUND LEV L 0'-0" United Pentecostal Fire Ministries NEW CBS BUILDING 202 E MIDWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com AUDIE ROBINSON, AR0094296 No. Description I Date 1 Bldg. Dept Revision 03/25/2021 ELEVATIONS Project number UPFM001 Date 02/17/2021 Drawn by MN Checked by AR Al 05 Scale 1/4" = 1'-0" a M co N N N O N 00 Con*4etion Detail Desarlpficir, Test Numbe�� STC Test Number Non-Loadbearing wt, 6 5/8" SflE7,ETfl&CKFlPEC,00ECore gypsum UL Des U419 40 USG-860808 A-2 �J t High Performance FS 6,fii Fire Block T Panels, or 5/8" Sfiirmocv UltraLight Ft;iEcom X Based on 5)8" &EETForK FnEcr,,DE:� Intumescent Firestop Sealant panels or 5/8" R­5ERO�Kpanels Core panels Product description 4'X,,g' 3-1/2" 25 glLlge steel studs 24" 0,C, ... Product description Ready-tio-use, intumescent flexible block based on a vvo­ optional inAllation 48 RAL-TL-1 1-068 Inturnescent (expands when exposed to fire�) firestop sealant that Gompo nent polyurethane foam optional RC-1 channel Based on 5/8" SHF.Fii�ok-I(FioE�,,rjn,�E Core holps proiort combusti lo and non tible penotrations'for up to 4 hours fire rating Product features Panels or 5/8"SHEETKICKUltralLight a Suitable for re -penetration or new penetrations Product features a Economic;al to use, with short installation tinias .4 1 1 . no� Easy instal lation — no special 1001t required sound bat Contains no halogen, solvents or asbestos Ideal for use in floors — no forming required 49 ...... High fire ratin 3 propeflies One sided wall systems available SA-870-717 Water based, easy to clean C Halogen, asbestos and solvent freo, Based on 5/8" SHEETROCK FiREcooE Core * Protects most typical firestop penetration applications Operational immediately after Installation panels, 3" mineral fiber insulatiorl a COD be painted ........ 6 Single component systems available FS-ONS Technical 0ata * Can be painted FS, 667 Technical Data 52 C"hicirpiol ba*m" W's - Smoke resistant Hod, RAL-TL-1 1 -071 a Meets LEEDI,'4 reciuiroments for indoor environmental qualitycredit 4VAe'aw'- 1­,Mrienwrr.t� 4 f1' r t Q Q 4' F 05' C' t 0 4 0' C i Based on 5/8" SHE1TRN-X Ultrall-ight FsKm,,�'; 4.1 Low Emitting Materials, Sealants and Adhesives and 4,2 Paint's Color, R0:J Areas of application I X pariels, R-1 1 fiborglass sound bat, RC-1 and. Coatings ApplicatfaTtOMPONBrUria 110 T to, 104 k * Sealing single or multiple penetratifins in small to large openings It Mr� ' ' a temporary or permainent sealing of cables and cable tray channel Areas of application 2wm&�A____Am_r2�21 _rT_1 � , penetrations J.L_:5 T N1 9 8 4 - M��Y112 * Steel, copper and EMT pipes tj�L�brgt oar -Ability . � � �, � �, ± pAm�*, '4,0 Sound tram�ririfaOon dassificatlio-I 64 tD JFXpansloo �ule. Up to 3's ttiril�o fF,*ates spedfi� constructwi a Temporary or permanent sealing of insulated and non-inSufated 53 a Insulated steel arid copper pipes ongln,% i6mul_E _91-11-9-11. HAL-TL-1 1 -076 TS=ZgMSL2�� metallicpipes and cornbuslible pipe penetrations Approvals jt�,t�ar'�Co c; u I e 40- Cable bundles 'CaPorria State Fr Based on 5/8" Slifflp.ocx FR.li'moE panels, Miming characteristot Flatrind Spread: 0 a tvlairshd Ustng No, 4486-VOD�10b �_E QC For uso with M F-A 31 "15 - i, il 6 - M Closed or vented plastic pipes A F, -0 og,,��,.Irinmmpt� A, R-1 1 fiberglass sound bat, R.C-11 channel Te�tiad in Aoovrclartae v�eO'i # JL. 14 4J, So'..'Orid trararn4sion homelAtea tc Walls (UL tested up to max. opening 52" x 48") a HVAG penetrations - A�STM E 8M ....... Floors (UL tested up to max. opening 36" x 3a") A A-1,TNI E 8-,; 54 RAL-TL-11-076 For use with Qlufarniafitate Rn':i [Johno P-�o. At V1,1F (,,'a 10) Concrete, porous concrete, masunry and gypsum wall asserriblies 0 Concrete, masonry, drywall and kvoodl floor assemblies cj�y o? tqeei'york MEA 3126-96-MV,61. N Based on 5/8" SIAEUP00K l_-lR1­'(;00j,, panels -1 Wall nsse—bil— ratari — to 4 hou- &MOi,0X"POW0 140WE", *%A' � '�—V Wail and floor asserriblies, rated up to 4 hours 1� ASTM E 814 Floor assembi I ies rated up to 33 hours OR ��AVJV IMA3 L-'IAL F 3" mineral fiber insulation, RCI channel M ......................... Examples �STM 12 64 ,'If ;'�Irp' Oi ire r�'iou&o rigAymirk Examples, 52 STC-120310 a Seating around pta%tic pipe penetrations in. fire rated construction, Completely dust and fiber free roonis and places where electrical �I;yi Based on 5/8" SIEETPOCK FfUDDE. panels. �8 IN I HHoLX,,,Ii Pi-14F I RAININ b nstallations are frequently used fie, computer centers, hospitals, -combuslible penetration Sealing around combustible and non a in tire rated construction U FALF40P S115reY4,5 11ILY1114 I'm =�Whya 1. L 4" 20 gauge steel studs 12" ox., T' ot ;-IFF, corc7cFre <:S> �aboratcvries, etc,) sew APPROVED mineral wool insulation, RC-1 channel a New buildings in the construction phase and during renovation ...... ........... Installatioti iristructions tor FS-ONE a Large openings containing multiple penetrations as found in production buys, warehouses, hosoitals etc, 52 STC-120306 Notice 4� Smoothing of frestnr, seaiart To c4onnplele the seal, i ion materias where. oil � plw�tjcizs�,ws o( solvenm nlalv Based on 5/8" Sheetrack Firecode panels, * Refort. handling, Tea<1 silatiWal Safety Dataf>beat and lool orum'dial ely I a 4�4've a Smooth appolwarice� bl"'d I e, irnpre�jilweiJ Wood, od base't Semi% it�oen 4" 20 gauge steel studs 16" o.c,, 3-1/2" product label forsife osage Ard neakh irformahon, Exuers!� tiodarit, P"lor 10 Curing, cao b.-I GIL4aried Lv partially vuiu I anieOeJiuloonr Installation instructions for FS 657 * Irmt1%1GLium� belc-w ate qwlerol gvidr"Nllei� —.vway:i away frvn idja;ent surfaces and toolu with wator lr� any pene'ration other �han thuse specifically Notice 4; Cornpleiely Uil cable -jitiaces, ga,lai ow-aven bloco Not for use glass fiber insulation, RC-1 channel reNr to tne applicable dra,�%-Irig in the UL Rro S. Leay.e, cornpleted seal undhitarb-m fG, 48 hGurE. degivibed in inis manual or the tesi reports berbte hithding, read 10,11tir-ol Saloty Dutafina�tt a�rid and pipes, and joints w1h FS-Olil E Fire�ilnp Saaiarit. lr�, wbt MOMI, ouldunn� or uxposed to the W�-'av'm'r Ratimlarce D�reOory or fliti FiFustop Svsteins Guide 0, For m alriteriarice feasons � a penetration -seal rould Product la'W, lor,,safu L*age ard lieaitti infoiiuzktiwi� 5� For maintenanca reasons, 4 nerietration seal Mtvd u, UV �adialion lCatt Lw done uily after applynig ari for corriplel a lnsUlal�an Information ne perrnane<My mafkad wim an idemsficanon wate� Storage Instructions belo'w are general guidei;nes — a�ivays, oe pernaigeritly ri%,iekel wilh aj iderilification vaw Lciatrig� i�e, Cp C,0 IS). 54 STC-1120307 # Store �urily i�n the 0(�q'rial p�%CkogtfiQ in �3 opening W %Urh a C&u" roark I'lo 160FAIficutim'I plate and protected Irom moisluro mt toriporaturos bakwoon re -far to The applicable drawinG in the 1.11, - Fire in auol a ca"m rnaik 'Ino, lCientitic"Aii'lo Plate 'vid Storage Based on 5/8" SHEEMOICA FIREWDE panels, lasteri 11 in a �Asiblb position noxt to the sool, Resilitarce Dractoiry or Kiti Fitestop Systnarris, C;qide IwAvn I,, m a visible pocsition next to the qi�al. i Goa"-li t" "'UTIKO's 10 'Whicirl FS-(J.NL will cie QT' (5'zQi und 8,5'F (39"Cl, S�oro, onl� P) Irie or g nal 1,'jili�k*,i, a 0 grill Ili , I canor, 4" 20 gauge Steel Studs 16" ox,., 4" OPplied tirOiAd be, deaut�d Of ICASe dimrti, dirt, Oil, Not for Use Obserie expiration date on the p&ckaq�ng for conripime instaflatorl infoallatior, Re -installing cables or other prolueAed koin a dj'ecl sijill grif mineral wool insulation, AC-1 channel rr0N,!1_,rU. triust &,nd Was- ShUc'turas supporltrig a High movernerl expwrision inints Opening penetrations pei�eltravng items must be zzistabou ai cornppanc�q * I - Clean the opering, Penetration arid panatrzition . Remove or cul the block fram the senl� ............ w4h loca� building and electricai standarzis, supporting !itfuctwres must be MaWled in 53 STC-120308 Application of firestop sealant compliarice with local bo,Mfing and . I , ristall Me pi-aietrant andre-lay the block in �=,mplmri�^e wi�h the appiroval, Fill gaps *,n Fqmices Based on 5/8" SuEETr,,0CK RREC00-- panels, P Insra"ll the ioresoolbed backlilhog maloria! �%Ze ur�'o wilh FS� ONE 4" 20 gauge Steel studs 16" o,c,, 3" diiplh to,) oblui�i Ira, dosired Tufiqj (it iroquiml(i� Loan Application of Fire Blocks Sirigle cabim ain be run uirouqh fmirits bstwueo twflicien! depth fur applying FS-CINL 2a.9f ra la0rietratians -are lo,:,ated. build tip FS 11557 IARL alackb or a hole, can be drill�sd through a blocX using mineral wool insulation, RC�l channel 3. Apponatiorinz f-,-Aop sea�'Iant: Apply FS-ONE tzi the SLOCK firm.ly sealed, wilhii opening. a sharpened piece of metal pipe or, tibing. required depth in oder ionbtain zhe der-ared ire rating, Pb, It Penetration-. an- !"augid, build up FS IlI57 FIRE t,(ake -jap FS-ONF crntacts all surfaces to pw'iiiie OW" r", F".;ICC BLOCK firmly ieeal,�d, While c0iing blocks Alin a nuaywitim adhosior, For appocatico, I at 176-ONE uso a jil eaq­�'iii FSA'Ar knife to Vail the ptor od Penal alions SILIndaroi C.ajjkeig ouli, toil paok ipjn� 6,jlk Wade( end wling 3, r4) sh buildirig uo I'lPE r3LOCK5until Onlrtj opL, bulk Win. With [,�S',ONLbuckfits, Gruco type &balant puitin may bo used. (GarAaLA wrrip rrianufactufor lot pmper seleciiari�. Ndd kipic" 0A lo Nim 1 6Al kv''�;hx"'x 4. r 11 pgln; vMt� Hilti Firestop to 'w ff Saving Lives qp�-'i"� V463 - BXUV.V463 - UL Product Spec 10/8118, M52 Appi, rr,-'to* .1 exxvilION'l E F&44" tbrough innovation and eckication HiltL Outnerform. Outlast. "Milb. C3utntm_rfnrm (1i itinat Kiti, Irio (U,SJ 1-800-879-8000 * www.us.hilti.com 6 en espafiol 1-600-879-5000 * H'§1V risestop S'Vstems Guide 2007 Hi fi, IVIG N SJ 1 -a00-879-8000 * www.us.hilti.com a eo espahoi 1-800-879-5000 * H Iti Fj�esmp S, w if] ym rns GLI A� 2007 Q­, NON SI/UL 263 Certified for United States -resistance Ratings - AN W, F "@p'w"' �MB "'n"';R IRW'01 M_ Design Criteria and Allowable Variances See General Information for Fire 3", ZIA 13 '4 ;p I'M AP W I I 'S V '33 "10 nn r-'anornt Inf^rrrinfinn fr)r Pira Poizi<zt:anno Pnfinn-, (A /HLC-S1 01 Certified for Canada 60, 'g 00 A d 2 01 ��'M N'� vg M'4� Design Criteria and Allowable Variances K www" n X '61 R� 'M AV Ov Desi n No. V 63 TY September 25, 2017 FIRE DEPARTMENT SIGNAGE CONTRACTOR SHALL PROVIDE IDENTIFICATION SYMBOL (MALTESE CROSS) WITH LETTER "R" FOR ROOF, LETTER "F�:" FOR FLOOR OR LETTERS TYP. PLATFORM H/1- [-UK �LUUK ANU HOOF FOR LIGHT -FRAME I KUbb - I YPE CONSTRUCTION (WOOD OR LIGHT GAUGE STEEL FRAMING MEMBERS) AS PER Nonbearing Wall Rating — I hr STATE STATUTES, LOCATED AT EACH MAIN ENTRY DOORS, THE HEIGHT SHALL BE FROM 41 TO 61 FROM F.F.E. Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. ASTRAGAL REQ'D HD & TDE BLTS DOOR SHEDULI: n4 n 81-01' @ NON EMER. DR 16 in, or 24 in OC 10 in, or 24 in (X 0 If - Oil if - Oil 6' - 0" < 7 31 - 4fl 61-411 J (+41.6 / -52.0) x X x x X, )( �e V 11 �e ,*off 00 :< Cr L.L co LIJ W F_ UJ X < co X CC CD rr LL r— I Page 1 "�f 6 :D LIJ 0 CD http://productspec.ul,com/doctimeill.php?id�BXUV.V463 (70 NOTE ON C0 71 :E cr _J < PLAN DR LOCN < DENOTES 45 MIN RATED DR IN PAIR 3070 X 13/4" FAUX WD PNL DRS 1 HR FIRE RATED IN 1 1/2 X 4" ALUM FRIVI (BRZ) (W/CLOSERS) 3070 X 13/4" EXTR. DRS (HN4) PR 3071, DR WALL IVIIIT IN 2" X 6" HM FRIVI (CLOSED) EQ TO'� 13/4" FAUX WD PNL DRS IN 1 112 4" ALUM FRM (BRZ) (W/CLOSERS) C' @ HDWR. NOTE - LEVEL TYPE OPERATOR REQ'S ALL PUBLIC ACCESS, DOOR UNITS WALL OR FLR STOPS TO BE PROVIDED / BUTTS B.B. TYPE *WHERE LOC'D IN FIRE PARTITION TROLLY TYPE CARRIERS 3068 X 13/4 5C WD. DR. IN IT, 2068 X 1 3!8 HC WD. FRM. (HM FRIVI IN 1 HR PARTIN) WD. DR. IN PKT. FRIVI. United ftmmtecostal Firwo% Ministries 1202 E IT111DWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com AUDIE ROBINSON, AR0094296 No. Description Date 0% 41-. e_," V� I ST� PARTITION TYPES & DETAILS Project number UPFIVI001 Date 02/17/2021 Drawn by MN Checked by AR A501 Scale As indicated 0 0 LO 7 CQ V463 - BXUV.V463 - UL Product Spec 10/8118, 19:52 V463 - BXUV.V463 - UL Product Spec 10/8118, 19:52 FIRE -RESISTANCE DESIGN Assembly Usage Disclaimer BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV? - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See General Information for Fire -resistance Ratings - ANSI/UL 63 Certified for United States Design Criteria and Allowable Variances See General Information for Fire Resistance Ratings CAN/UL.C-S101 Certified for Canada Design Criteria and Allowable Variances Design No. V463 September 25, 2017 Nonbearing Wall Rating -1 hr Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. http://produ ctspec.0 1. comi'docu ment. php?id=BXUV,V463 Page 1 of 6 V463 - BXUV.V463 - UL Product Spec 10/8/18, 19:52 1A. Steel Floor and Ceiling Runers - (Not shown) - as an alternate to item 1 - for use with Item 2A - 3-5/8, 4 or 6 in. wide by 1-1 /4 in. deep channels, depending on steel stud width (item 2A). Attached to the supporting structure with fasteners 2 ft OC. SCAFCO STEEL STUD MANUFACTURING CO - Type SoundGuard Framing System 2. Steel Studs - Nominal 1-1/2 in. by 3-1/2 in., spaced 2 ft OC maximum, fabricated from minimum 25 MSG (0.022 in., minimum bare metal thickness) galvanized steel. Studs attached to floor and ceiling runners with 3/8 in. No.6, steel screws on both sides of the studs. For locations that are not accessible for mechanical fastening, the flange of the stud shall be fastened to the track by tack welding. 2A. Steel Studs - As an alternate to Item 2 - for use with Item 1 or 1 A. - Double row of min. 1-5/8 in. wide by min. 1-1/4 in. deep studs, separated by 3/8 in. foam spacers (3-5/8 in. total width) or 3/4 in. foam spacers (4 in. total width) or doube row of min. 2-1/2 in. wide by min. 1-1/4 in. deep stud, separated by 1 in. foam spacers (6 in. total width). SCAFCO STEEL STUD MANUFACTURING CO - Type SoundGuard Framing System 3. Gypsum Board* - Nominal 5/8 in. thick, 4 ft wide panels, applied vertically to studs and runners with 1-1/4 in. long, No. 6, Type S screws spaced at 8 in. OC along the perimeter of the panels and 12 in. OC in the field. Vertical joints centered over studs and staggered one stud cavity on opposite sides of stud. Horizontal joints of vertically applied panels to be staggered 4 ft on opposite sides of the wall. PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM - QuietRock ES 3A. Wall and Partition Facings and Accessories* - (As an alternate to Item 3) - Nominal 5/8 in. thick, 4 ft wide panels, applied vertically to studs and runners with 1-1/4 in. long, No. 6, Type S screws spaced at 8 in. OC along the perimeter of the panels and 12 in. OC in the field. Vertical joints centered over studs and staggered one stud cavity on opposite sides of stud. Horizontal joints of vertically applied panels to be staggered 4 ft on opposite sides of the wall. Horizontal joints of vertically applied QuietRock 527 and QuietRock 528 panels need not be backed. PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM - QuietRock lhttp://productspec.ul.comldocument.plip?id=BXUV.V463 Page 3 of 6 1. Steel Floor and Ceiling Runners - (Not Shown) - Min. 3-5/8 in. wide by 1 1/4 in. deep channel, fabricated from minimum 25 MSG (0.022 in., minimum bare metal thickness) galvanized steel. Attached to the supporting structure with fasteners 2 ft OC. Configurations B and C shall utilize two, separate tracks along the floor and ceiling. Track(s) width to accommodate stud(s) width. http:ijproductspec.ul.com/document.php?id=BXUV.V463 V463 - BXUV.V463 - UL Product Spec 527, QuietRock 528, QuietRock 530. Page 2 of 6 1018113, 19:52 313. Gypsum Board* - Any 518 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. (As an alternate to Items 3 and 3A; on only one side of the assembly, for use only in Configuration A, when the studs are spaced 16 in. or 24 in. OC) - Nominal 5/8 in. thick, 4 ft wide, applied vertically to studs and runners with 1-1/4 in. long, No. 6, Type S screws spaced at 8 in. OC along the perimeter of the panels and 12 in. OC in the field. Vertical joints centered over studs and staggered one stud cavity on opposite sides of stud. Horizontal joints of vertically applied panels to be staggered 4 ft on opposite sides of the wall. Horizontal joints of vertically applied panels need not be backed. ACADIA DRYWALL SUPPLIES LTD (View Classification) - CKNX.R25370 AMERICAN GYPSUM CO (View Classification) - CKNX.R14196 BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO (View Classification) - CKNX.R19374 CERTAINTEED GYPSUM INC (View Classification) - CKNX.R3660 CGC INC (View Classification) - CKNX.R19751 GEORGIA-PACIFIC GYPSUM L L C (View Classification) - CKNX.R2717 CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C (View Classification) - CKNX.R18482 LOADMASTER SYSTEMS INC (View Classification) - CKNX.R11809 NATIONAL GYPSUM CO (View Classification) - CKNX.R3501 PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM (View Classification) - CKNX.R7094 http://productspec.ul.com/document.php?id=BXUV,V463 463 - BXUV.V463 - UL Product Spec PANEL REY S A (View Classification) - CKNX.R21796 SIAM GYPSUM INDUSTRY (SARABURI) CO LTD (View Classification) - CKNX.R19262 GEORGIA-PACIFIC GYPSUM L L C (View Classification) - CKNX.R6937 THAI GYPSUM PRODUCTS PCL (View Classification) - CKNX.R27517 UNITED STATES GYPSUM CO (View Classification) - CKNX.R1319 USG MEXICO S A DE C V (View Classification) - CKNX.R16089 Page 4 of 6 1018/18, 19:52 5/8" GYPSUM W/ BOA GABLE END STUCCO DETAIL BOTTOM OF ROOF SRUCTURE EXTERIOR SHEATHING END GABLE TRUSS CEILING. REFER TO CLG. PLANS 3-5/8" INSULATION BLANKET 7/8" STUCCO ON LATH ON MOISTURE BARRIER ON EXTERIOR GRADE SHEATHING PT WOOD IN CONTACT W/ MASONRY/CONC. TYP MOISTURE BARRIER FACE OF CMU LATH WEEP SCREED 4" MIN. ABOVE GRADE 2" MIN. ABOVE ROOF SURFACES BOTTOM OF ROOF SRUCTURE CEILING. REFER TO CLG. PLANS CERAMIC TILES 3-5/8" SOUND ATTENUATION BLANKET 2X4 STUDS @ 16" O.C. 5/8" GYPSUM WALL BOARD BOTH SIDES CONT. GALV. METAL RUNNER FINISH FLOOR AS SCHEDULED G3 TYP. GWB PARTITION W/ CERAMIC TILE ONE SIDE GWB THE OTHER SIDE RESTROOMS ADJACENT STANDARD ROOMS 0\ CEILING. REFER TO CLG. PLANS 3 5/8" SOUND ATTENUATION BLANKET 2X4 STUDS @ 16" O.C. 5/8" GYPSUM WALL BOARD BOTH SIDES CONT. GALV. METAL RUNNER FINISH FLOOR AS SCHEDULED G1 TYP. GWB PARTITION AT STANDARD ROOMS PARTITION TYPES & DETAILS 2X8 CONT 2X6 CONT 4X4 MTL EDGE Elmo in (JCC J 1 r1UU 1 Ur1HL) G TYP EXTR WALL SECTION 1 _ 1 �_0„ WALL SECTION. 1 V-10" United Pentecostal Fire Ministries NEW CBS BUILDING 202 E M I DWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com AUDIE ROBINSON, AR0094296 No. Description Date 1 Bldg. Dept Revision 03/25/2021 3 Bldg. Dept Revision 7/02/2021 WALL SECTION, PARTITION TYPES & DETAILS Project number UPFM001 Date 02/17/2021 Drawn by MN Checked by AR A502 Scale As indicated a K 3 (2) 2X8 ,TYP Platform Section (Typ.) 5 CARPET FINISH BY OWNER 2X8 BRIDGING, TYP 2X8'S @ 16" O.C., TYP WOOD 2X8 BRIDGING, 48" O.C..TYP zi� . CONG. SKAS 2. iYP. CONC. SLAB JOINT DETAILS2" 1, PROVIDE OPENINGS & COVER PLATES FOR CONDUIT AND OUTLETS PER OWNER (2) 2X8 ,TYP WALLS LOCATIONS TYP. e 3 z s I..................,.-...........,............�� ............�...�.�..�.,....� Ramp Section a ,a -, METAL CABINETOGLASS PA k United Pentecostal Fire Ministries 114" METAL SCREW TOP BOTTOM NEW CBS BUILDING &-a 101; *01 A g "01 W CONTRACTOR SHALL INSTALL RECESSED FIRE EXTINGUISHER CABINET AT FIRE EXTINGUISHER LOCATIONS SHOWN ON LIFE SAFETY PLAN FIRE EXTINGUISHER CABINET3 1 I!= 1 1-011 9.1 202 E MIDWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com 4�I� AUDIE ROBINSON, AR0094296 No. I Description I Date 1I Bldg. Dept Revision 03/25/2021 MISC. , PLATFORM & RAMP DETAILS Project number UPFM001 Date 02/17/2021 Drawn by MN Checked by AR A561 Scale As indicated Hip Cap Field Notched Neoprene Pre Notched Z Closure S.S. Painted Pop Rivet 1„ 24Movable Clip � ATA-Guard > > METAL ROOF HIP DETAIL # 10 x 1" Wafer Head Screw Eave Trim Trim Board Standing Seam Panel Plywood Substrate ATA-Shield 1" Movable Clip ATA-Guard \ # 10 x 1" Wafer Head Screw /Appropriate Sealant / Butyl Tape ri C-CI l II ICCI CU ll UJ'CJ Standing Seam Metal Panel Pre-engineered Trusses Standing Seam Metal Panel ATA-Guard Plywood Substrate\ Vented Ridge Cap Field Notched Neoprene \ Vented Z Closure S.S. Painted Pop Rivet 1" Movable Clip 2411 0. Standing Seam 40100 Metal Panel Plywood Substrate Wall Appropriate Sealant Appropriate Anchor Fastener Counterflashing (anchor when appropriate ATA-Shield (1 width "I\ Sidewall Trim oll) S.S. Painted Pop Rivets 24" O.C. Trim Board \ METAL ROOF ENDING SIDEWALL Wall Appropriate Sealant Appropriate Anchor Fastener METAL ROOF. Y- V V V - r r r r r . r . . . . . . — # 10 x 1 Wafer Head Screw INTERIOR WINDOW W/ LAMINATED TEMPERED GLASS (OPTION FOR SLIDER AT AV ROOM) Appropriate Sealant Butyl Tape I j ATA-Guard FASTEN WINDOW SYSTEM W/ CORROSION RESISTANT 1-3/4" TAPCON PER MANUFACTURERS ••% RECOMMENDATION FOR SPACING Plywood Substrate / CONT. SEALANT AND BACKER ROD METAL ROOF VENTED RIDGE DETAIL 6" = 1'-0" 'Z' GALV. METAL CHANNELS @ 24" O.C. MASONRY WATER PROOFING CEILING SYSTEM AS SPECIFIED 8" BOND BEAM, REFER TO STRUCTURAL DRAWINGS RIGID INSULATION GALV. METAL CORNER BEAD CONT, BACKER ROD AND SEALANT CONT. SEALANT AND BACKER ROD IMPACT RESISTANT WINDOW SYSTEM 'C' GALV. METAL CHANNEL 5/8" GYP BD 1 1/2" RIGID INSULATION EXTRU[)FD POLYSTYRENE Plywood Substrate ATA-Guard /Standing Seam Metal Panel 1" Movable Clip ARTING SIDEWALL MASONRY WATER PROOF NG 'Z' GALV. METAL CHANNELS @ 24" O.C. 1 1/2" RIGID INSULATION 'Z' GALV. METAL CHANNEL`' @ 24" O.C. MASONRY WATER PROOFING 8" CMU 7/8" STUCCO FINISH WINDOW HEAD DETAIL 3 3" = 1 '-0" \ METAL STUD — 5/8" GYPSUM BOARD EACH SIDE ON 3 5/8" METAL STUDS INTERIOR WINDOW DETAIL, TYP. JAMB/HEAD/SILT 3" = V-0" 8" CMU, REFERENCE STRUCTURAL DRAWINGS FOR FILLED CMU CELL REQUIREMENTS BACKER ROD AND SEALANT, BOTH SIDES, TYPICAL IMPACT RESISTANT DOOR F ASSEMBLY 8" CMU a. 7/8" STUCCO FINISH INSTALL WINDOW SYSTEM W/ CORROSION RESISTANT FASTENERS PER MANUFACTURERS RECOMMENDATION AND PRODUCT APPROVAL FOR SPACING SEE WINDOW HEAD DETAIL FOR TYP. NU I t5 WINDOW SILL DETAILINT31OR 3 3„ = 1'-0" SEE WINDOW HEAD DETAIL FOR TYP. NOTES EXTERIOR WINDOW JAMB DETAIL 2 2 3„ = 1 '-0" EXTERIOR EXTERIOR STALL WINDOW SYSTEM W/ CORROSION RESISTANT STENERS PER MANUFACTURERS :COMMENDATION AND PRODUCT APPROVAL IR SPACING 3" STUCCO FINISH 8" CMU c I'" 3YP. BD GALV. METAL CHANNEL NDOW SYSTEM. SEE NOA FOR :TAILS. United Pentecostal Fire Ministries NOTE: DOOT TO BE INSTALLED PER NOA PRODUCT APPROVAL REQUIREMENT NEW CBS BUILDING ` MASONRY "T"-STRAP 3 PER JAMB AT CMU WALL, TYP. DOOR MASONRY DETAIL 5 7 311 = 1 ,_O„ 8" CMU, REFERENCE STRUCTURAL DRAWINGS FOR FILLED CMU CELL REQUIREMENTS BACKER ROD AND SEALANT, BOTH SIDES, TYPICAL IMPACT RESISTANT DOOR ASSEMBLY E DOOR MASONRY DETAIL 6 6) 5/8" GYPSUM BOARD EACH SIDE ON 3 5/8" METAL STUDS METAL STUD BOX BEAM HOLLOW METAL DOOR FRAME DOOR AS PER SCHEDULE " VARIES REFER TO PARITION TYPES DOOR GWBDETAILS 0' -1 0'. 2" VSTALL WINDOW SYSTEM W/ CORROSION RESISTANT -ASTENERS PER MANUFACTURERS ZINN 1ECOMMENDATION AND PRODUCT APPROVAL L -'OR SPACING DOUBLE STUDS AT JAMB HOLLOW METAL DOOR FRAME Nco Cl- Z: 0 w � Q Q > a 0 R Cr U_Uj \ ` DOOR PER SCHEDULE D O OR GWB DETAIL 6\ 3/5/8" M BOARD EACH SIDE ON 4 3„ = 1'-0„ 202 E M I DWAY ROAD FORT PIERCE, FLORIDA SAVANNAPUB, INC. PO Box 773553, OCALA FL 34477 813-313-7707; savannapub@gmail.com AUDIE ROBINSON, AR0094296 No. Description Date 1 Bldg. Dept Revision 03/25/2021 DOOR, WINDOWS & ROOF DETAILS Project number UPFM001 Date 02/17/2021 Drawn by MN Checked by AR A601 Scale As indicated Al