HomeMy WebLinkAboutRoofing PlansE N E R r? C STRUCTURAL DESIGN CRITERIA: 1. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. 1. THE DESIGN COMPLIES WITH THE BUILDING CODE - (2020 7TH EDITION) AND = THEY ARE NOT INTENDED TO SCALED FOR ROUGH -IN MEASUREMENTS OR TO ALL OTHER REFERENCED CODES AND SPECIFICATIONS. ALL CODES AND SERVE AS SHOP DRAWINGS OR PORTIONS THEREOF. SPECIFICATIONS SHALL BE THE LATEST EDITION AT THE TIME OF PERMIT. 2. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL, AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR SITUATION 2. WIND LOAD CRITERITA: ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL OR SECTION IS SHOWN. BASED ON THE ANSI/ASCE 7-10, WIND VELOCITY 180 MPH., K = 0.85 3. PRIOR TO START OF CONSTRUCTION, THE CONTRACTOR AND ALL THE OCCUPANCY CATEGORY #3 (AT HURRICANE OCEAN) EXPOSURE "C". SUBCONTRACTORS SHALL VERIFY ALL GRADES, LINES, LEVELS, DIMENSIONS AND COORDINATE EXISTING CONDITIONS AT THE JOB SITE WITH THE PLANS AND 3. ROOF DESIGN LOADS: SPECIFICATIONS. ANY INCONSISTENCIES OR ERRORS FOUND, MUST BE REPORTED TO THE ARCHITECT/ENGINEER BEFORE COMMENCING THE WORKS. THE CONTRACTOR AND HIS SUB -CONTRACTORS SHALL LAY OUT THEIR WORK FROM ESTABLISHED DEAD LOADS: . . . . . . . 25 PSF REFERENCE POINTS AND BE RESPONSIBLE FOR ALL LINES, ELEVATIONS AND LIVE LOADS : . . . . . 30 PSF M E A S U R E M E N T S I N C O N N E C T I O N W I T H T H E I R W O R K. i NET UPLIFTS: 4. ANY ERRORS OR OMISSIONS APPEARS IN THE DRAWINGS, GENERAL NOTES OR ZONE 1U = 30 P.S.F. OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OR ZONE (2) = 46 P.S.F. SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH THE WORK WHICH APPEARS ZONE (3) = 46 P.S.F. IN QUESTION. IN THE EVENT OF THE CONTRACTOR FAILING TO GIVE SUCH AN ADVANCE NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULT OF ANY SUCH ERROR OR OMISSION PLUS THE COST OF RECTIFYING THE SAME. B) PREFABRICATED WOOD TRUSSES NOTES. 5. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS AND SPECIFICATIONS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, SHOP DRAWINGS 1). - 2"x4" CONT. BOTTOM CHORD BLOCKING @ 8'-0" MAX. AND DRAWINGS OF OTHER TRADE TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS. W/ 2-1 6d TOE NAILS AT EACH INTERSECTING TRUSS. OUTLETS, RECESSES, OPENINGS, BOLTS SETTING, SLEEVES, DIMENSIONS, ET AL. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY POTENTIAL CONFLICT BEFORE PROCEEDING WITH THE WORK. 2). - ROOF SHEATHING SHALL BE -%" CDX EXTERIOR PLYWOOD 6. THE CONTRACTOR SHALL FIELD CHECK ALL DIMENSIONS ON THE WITH 10d NAILS @ 6" o.c AT EDGES AND INTERIOR STRUCTURAL DRAWINGS AND VERIFY SAME ON THE ARCHITECTURAL SUPPORTS. SET. ARCHITECTURAL DETAILS SUCH AS; SLAB DEPRESSIONS, WATERPROOFING, CURBS, MECHANICAL OPENINGS, FASCIA FRAMING AND 3). - ALL TRUSSES (U.O.N.) TO BE FASTENED TO CONCRETE BRACING SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL BEAMS WITH NU-VUE NVHTA20 DOUBLE STRAP W/ 8-10d SET. x 1 1 /2" ON EACH STRAP AND 6- 10d ON SEAT PLATE, N.O.A. 08-0325.02 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND BRACING TO ENSURE SAFE WORKING CONDITIONS AT ALL TIMES. ALL CONSTRUCTION SHALL CONFORM TO THE FLORIDA BUILDING CODE. TRUSS MANUFACTURER NOTES. 1) IN ADDITION TO THE SPECIFIED SHOP DRAWINGS 8c DELEGATED ENGINEERING: DESIGN LOADS, TRUSSES MUST BE DESIGNED FOR AN ADDITIONAL 20# LOAD IN BOTTOM CHORD PANEL 1. ALL SHOP DRAWINGS SHALL BE SUBMITTED FOR ENGINEERS REVIEW ONLY AFTER POINTS AS PER FBC R 4403.4.3. THEY HAVE BEEN THOROUGHLY REVIEWED BY THE CONTRACTOR FOR CONSTRUCTION METHODS, BIMENSIONS AND OTHER TRADE REQUIREMENTS, AND STAMPRD WITH THE 2) TRUSS SPECIALTY ENGINEER PLEASE NOTE CONTRACTOR'S APPROVAL STAMP. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THAT OVERSTRESSING OF WOOD FOR WIND DIMENSIONS, QUANTITIES, ENGINEESING DESIGN BY DELIGATED ENGINEERS, ERRORS, OR OMISSION AS A RESULT OF REVIEWING ANY SHOP DRAWINGS. ANY ERRORS OR DESIGN IS ALLOWED BUT NOT TO OVERSTRESSED OMISSIONS MUST BE MADE GOOD BY THE CONTRACTOR, IRRESPECTIVE OF HIS TRUSS METAL PLATES. RECEIPT, CHECKING OR REVERWING OF DRAWINGS BY THE ENGINEER AND EVEN THOUGH THE WORK IS DONE IN ACCORDANCE WITH SUCH DRAWINGS. 2. BEFORE STRUCTURAL INSPECTION CAN BE MADE ON ANY PORTION OF THE TERMITE PROTECTION COMPLIANCE: STRUCTURE, ALL RELATED SHOP DRAWINGS, DELIGATED ENGINEERING, PRODUCT APPROVAL, MANUFACTURER'S DATA AND OTHER RELATED INFORMATION, MUST BE REVIEWED AND ACCEPTED BY ENGINEER OF RECORD AND REVIEWED BY THE BUILDING DEPARTMENT. THE GENERAL CONTRACTOR MUST PROVIDE A CERTIFICATE OF COMPLIANCE A LICENSED PEST CONTROL COMPANY THAT CONTAINED THE FOLLOWING STATEMENT AS 3. ALL SHOP DRAWINGS SHALL CONTAIN THE MINIMUM INFORMATION AS OUTLINED PER FBC 2020, SECTION 1816.1.7 IN THE FLORIDA BUILDING CODE. 4. ALL DELEGATED ENGINEER'S SHOP DRAWINGS SHALL COMPLY WITH ALL THE THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF REQUIREMENTS OF THE FLORIDA BUILDING CODE. SUBTERRANEAN TERMITE IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY SHOP DRAWINGS SHALL CONTAIN ALL INFORMATION SHOWN ON THE STRUCTURAL THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICE. PLANS (RELATED TO THE THE DELIDATED DESIGN) INCLUDING ALL DESIGN LOADS IN ADDITION TO THE INFORMATION REQUIRED BY THE DELIGATED ENGINEER'S DESIGN. SOIL STATEMENT: 5. THE ENGINEER OF RECORD SHALL REVIEW ALL SHOP DRAWINGS, PREPARED, SIGNED AND SEALED BY THE CONTRACTOR'S DELEGATED ENGINEER, ONLY FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT, REQUIRED LOADING AND CO-ORDINATION WITH THE STRUCTURE DESIGNED BY THE ENGINEER OF RECORD. DESIGN BEARING CAPACITY: SOIL AT THIS SITE IS SAND & ROCK ADEQUATE TO SUPPORT THE 6. CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF RECORD ONLY ONE (1) SET DESIGN LOAD OF 2000 PSF. AFTER EXCAVATION SIGNED AND SEALED OF SEPIA AND ONE (1) SET OF BLUE PRINT OF THE STRUCTURAL SHOP DRAWINGS LETTER WILL BE SUBMITTED BY THE ARCHITECT OR THE ENGINEER FOR ENGINEER'S REVIEW BEFORE STARTING FABRICATION. THE ENGINEER WILL ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION RETURN THE MARK-UP AND STAMPED SEPIA TO THE ARCHITECT. THESE SEPIA COPIES SHALL BE USED TO MAKE PRINTS AS REQUIRED FOR THE SHOP DRAWING CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS DISTRIBUTION. SET OF BLUE PRINTS (WITHOUT SEPIA) WILL NOT BE ACCEPTED. BASED ON. CONSTRUCTION MEANS AND METHODS: . 1. THE CONTRACTOR IS RESPONSIBLE, AND SHALL COMPLY WITH THE SAFETY REQUIREMENTS OF THE FLORIDA BUILDING CODE, PLUS ALL LOCAL, STATE AND FEDERAL LAWS 2. PROVIDE ALL SHORING, BRACING AND SHEETING AS REQUIRED FOR SAFETY, STRUCTURAL STABILITY AND FOR THE PROPER EXECUTION OF THE WORK AND MUST BE REMOVED UPON THE COMPLETION OF THE WORK. 3. PROVIDE AND MAINTAIN GUARD LIGHTS AT ALL BARRICADES RAILING, OBSTRUCTION ON THE STREETS, ROADS OR SIDEWALK AND ALL TRENCHES OR PITS ADJACENT TO PUBLIC WALKS AND ROADS. 4. AT ALL TIMES, PROVIDE PROTECTION AGAINST THE WEATHER (RAIN, WIND, STORM OR SUN) IN ORDER TO MAINTAIN ALL WORK, MATERIAL, MACHINE AND FIXTURES FREE FROM INJURY OR DAMAGE. 5. AT THE END OF EVERY DAYS WORK, COVER FOR PROTECTION, ALL WORK THAT IS SUBJECT TO DAMAGE. BY FAILURE TO PROVIDE SUCH PROTECTION, DAMAGES DONE WILL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. 6. THE CONTRACTOR SHALL PAY FOR ALL DAMAGES TO ALL ADJACENT PROPERTY. CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND HOLDS RESPONSIBILITY FOR ALL MEASUREMENTS ROOFING NOTES ALL OVERHANGS SHALL BE 2'-0" EXCEPT WHERE NOTED. LAYOUT OF ROOF TRUSSES SHv_L BE DESIGNED BY TRUSS MANUFACTURER GENERAL CONTRACTOR SHALL PROVIDE DROPPED TIE -BEAM W/2- #5 TOP, 2- #5 MIDDDLE & 2- #5 BOTTOM @ ALL DOOR/WINDOW OPENINGS GENERAL CONTRACTOR SHALL COORDINATE W/TRUSS MANUFACTURER AND MECHANICAL CONTRACTOR THE PROVISION OF ALL A/C DUCT WORK OPENINGS THRU. TRUSSES. SHOP DRAWINGS SHALL BE SUBMITTED BY CONTRACTOR FOR APPROVAL BY THE ARCHITECT/ENGINEER OF RECORD GENERAL CONTRACTOR SHALL COORDINATE W/TRUSS MANUFACTURER THE VERIFICATION OF THE SLOPE OF NEW ROOF & CONTACT ARCH/ENG. ABOUT ANY DISCREPANCIES BETWEEN THE SLOPE SHOWN ON DRAWINGS AND THE ACTUAL SLOPE IN SITE. APPROVAL OF TRUSS PLAN BY THE ARCH /ENG. SHALL NOT RELEASE THE TRUSS MANUFACTURER /CONTRACTOR FROM THEIR RESPONSIBILITY IN VERIFYING THE ROOF SLOPE. CONCRETE AND REINFORCING: 1. SHALL BE A MIX DESIGNED WITH HOT WEATHER CONCRETING. IN ACCORDANCE WITH A.C.I. 301 TO ACHIEVE A 28-DAY COMPRESSIVE STRENGTH OF 3,000 P.S.I. AND A SLUMP OF 4". 2. EACH CUBIC YARD OF CONCRETE SHALL CONTAIN A MIN. OF 5 BAGS OF CEMENT. 3. TRANSPORTATION, PLACING AND CURING OF CONCRETE SHALL COMPLY WITH A.C.I. 318 BUILDING CODE (LATEST EDITION). 4. ALL CONCRETE STRUCTURAL COMPONENTS SHALL HAVE CONCRETE STRENGTH TESTED IN ACCORDANCE WITH A.S.T.M. STANDARDS, F.B.C. 2020, AND A.C.I. 318 (LATEST EDITION). TEST CYLINDERS MUST BE TAKEN EVERY 50 CUBIC YARDS ON CONCRETE PRIOR TO PLACEMENT. TESTING LAB SHALL PROVIDE COPIES OF CONCRETE TEST RESULTS TO ENGINEER OFFICE FOR REVIEW. 5. CONCRETE MIX DESIGN SHALL BE SUBMITTED TO ENGINEERS OFFICE FOR REVIEW AND APPROVAL PRIOR TO PLACING ANY DESIGN MIX. 6. CONTRACTOR SHALL CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE. 7. ALL REINFORCING TO BE NFW BILLET STEEL CONFORMING TO THE LATEST A.S.T.M A-615 GRADE 60, FABRICATED IN ACCORDANCE WITH C.R.S.I MANUAL OF STANDARD PRACTICE AND PLACED IN ACCORDANCE WITH A.C.I 315 AND C.R.S.I MANUAL OF STANDARD PRACTICE. 5. CONCRETE COVER UNLESS OTHERWISE DETAILED ON DRAWING: GRADE BEAM: (BOTTOM) . . . . . . . . . 3" (TOP & SIDES) . . . . . . . . . . 2" EXTERIOR SLAB ON GRADE (BOTTOM) . . . . . . 2" COLUMNS AND BEAMS (TO THE TIES). . . (TOP) 1 1 /2" 1 1 /2" 6. COLUMN REINFORCEMENT: DOWELS TO BE SAME SIZE AND NUMBER AS VERTICAL RE -BARS ABOVE. LAP MAX. 36 TIMES THE DIAMETER OF THE BAR OR MIN. 18 INCHES, U.O.N. , PROVIDE RIGID TEMPLATES FOR DOWEL LOCATION. PROVIDE STANDARD HOOKS AT TOP OF ALL VERTICAL REINFORCEMENT AT NON -CONTINUOUS COLUMNS (U.O.N) 7. ALL DOWELS FOR COLUMNS SHALL BE SECURED IN POSITION PRIOR TO CONCRETING. PUSHING THE DOWELS INTO POSITION IN WET CONCRETE IS UNACCEPTABLE. 8. BEAM RE-INFORCRMENT: LAPPED 36 BAR DIAMETER OR MIN. 18 (SEE BEAM DIAGRAM ON PLAN). BOTTOM BARS SPLICED ONLY AT SUPPORTS, TOP BARS SPLICED ONLY AT MID SPAN. ALL TOP BARS HOOKED AT NON -CONTINUOUS EDGES (U.O.N) ALL HOOKS TO BE STANDARD 90 DEGREE HOOKS AS REQUIRE. (U.O.N) 9. ADD REINFORCEMENT: PROVIDE ADDITIONAL CORNER BARS BENT 36 INCHES MINIMUM EACH WAY AT 1" AND "T" CORNERS IN OUTER FACE OF ALL BEAMS TO MATCH ALL HORIZONTAL BAR (TOP, BOTTOM AND INTERMEDIATE RE -BARS) 10. SEE PLAN PLAN FOR MINIMUM SIZE CONCRETE TIE BEAM REQUIREMENTS REINFORCED MASONRY WALLS: 1. CONCRETE MASONRY UNITS SHALL COMPLY WITH THE PROVISIONS OF T HE STANDARD SPECIFICATION FOR DESIGN AND CONSTRUCTION OF LOAD BEARING CONCRETE MASONRY, NCMA TR-75B AND ACI 530.1. 2. HOLLOW LOAD BEARING MASONRY UNITS SHALL CONFORM TO A.S.T.M C-90, TYPE-1, (STANDARD SPECIFICATIONS FOR HOLLOW LOAD BEARING CONCRETE MASONRY UNITS" 2. SPECIAL INSPECTOR SERVICE ARE REQUIRED FOR ALL REINFORCED MASONRY CONSTRUCTION. THE SPECIAL INSPECTOR SHALL INSPECT THE PLACING OF THE REBAR IN THE CELLS, VERIFY CLEANLINESS OF THE CELL, VERIFY THE CELLS TO BE GROUTED, AND OBSERVE THE PLACING OF THE GROUT OR CONCRETE INTO THE CELLS. 3. MORTAR SHALL CONFORM TO A.S.T.M C-270. TYPE "M" OR "S" WITH A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI. ON THE NET AREA.. 4. LAY ALL MASONRY WITH FULL FACE HEAD JOINTS AND WITH FACE SHELL MORTAR BEDDING. 5. MASONRY ANCHORAGE TO SUPERSTRUCTURE SHALL BE PROVIDED IN ACCORDANCE WITH STRUCTURAL DRAWING AND DETAILS. 6. THE USE OF ADMIXTURE SHALL NOT BE PERMITTED WITHOUT PRIOR REVIEW OF THE ENGINEER. 7. VERTICAL REINFORCING: (A) ASTH A-615 PER REINFORCING SECTION. (B) WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALL NOT BE SLOPED MORE ONE HORIZONTAL INCH TO S!X INCHES VERTICAL FOR ALIGNMENT, EVEN THOUGH IT IS IN A CELL ADJASCENT TO THE VERTICAL WALL REINFORCEMENT. (C) VERTICAL REINFORCING STEEL SHALL BE PLACED CENTER IN THE CELL LAP 48 BAR -DIAMETER. PROVIDE, BAR SPACERS AS REQUIRED TO MAINTAIN REINFORCING SECURED IN POSITION. MAXIMUM LIFT HEIGHT TO BE 8'-0" (C-1) (D) VERTICAL REINFORCING SHALL BE PROVIDED AT EACH SIDE OF OPENINGS IN WALL, AT WALL INTERSECTION, CORNERS AND ENDS. THIS REINFORCING SHALL BE THE SAME SIZE AS THE SCHEDULED WALL REINFORCING FOR THE PARTICULAR WALL BUT NEVER LESS THAN A # 5 REBAR. SPECIAL CARE SHALL BE TAKEN TO ENSURE THAT CELLS TO BE GROUTED LINE UP PROPERLY AND ARE CLEAN OFF EXCESS MORTAR. (E) FC-1 REINFORCING SHALL BE # 5 VERTICAL IN CONCRETE FILLED CELLS WHERE INDICATED ON PLANS. (F) ALL VERTICAL REINFORCING BARS SHALL BE HOOKED INTO THE BOND BEAMS AT THE NON -CONTINUOUS END OF THE REBAR. 8. HORIZONTAL REINFORCING: PROVIDE GALVANIZED # 9 GAUGE !_ADDER TYPE HORIZONTAL JOINT REINFORCING EVERY SECOND BLOCK COURSE (V-4" O.C. VERTICALLY) LAPPED 7 1/2". PROVIDE SPECIAL HORIZONTAL REINFORCING AT "T" AND "L" INTERSECTION. ANCHOR TO COLUMNS WITH MINIMUM 4" EXTENSION INTO AREA OF POUR. 9 PROVIDE "DOVE -TAIL" ANCHORS 16" D.0 VERTICALLY FOR ALL MASONRY PLACED ADJACENT TO ALREADY IN PLACE COLUMNS. 10. CELL FILLING CONCRETE SHALL BE "PEA -DOCK CONCRETE MIX (8" TO 9" SLUMP) OR GROUT WITH f2c=3,50OPS1 MIN. AT 28 DAYS. 11. LINTELS (A) THE CONTRACTOR SHALL PROVIDE PRECAST CONCRETE OR, CAST -IN-PLACE LINTELS AT THE HEAD OF ALL OPENINGS IN MASONRY WALLS NOT EXCEEDING SIX (6') FEET IN WIDTH WHERE BEAM HAS NOT BEEN SPECIFIED. FOR OPENING ADJACENT TO CONCRETE COLUMN, THE LINTEL SHALL BE CAST -IN -PLACE WITH THE COLUMN. (B) LINTEL MAY BE INTEGRAL WITH THE STRUCTURAL OR TIE BEAM WHEN HEAD OF THE OPENING IS 16" OR LESS BELOW. CONTINUE BEAMS TYPICAL BOTTOM REBAR THROUGHOUT AND ADD 2 # 5 BOTTOM TRUSS BARS AT DROP, AND 2 # 3 STIRRUPS AT 6" O/C EACH END OF DROP. (C) MINIMUM BEARING FOR ALL LINTELS MUST BE 8" INCHES EACH SIDE, OR PROVIDE DOWELS AND POCKETS IN ADJACENT CONCRETE COLUMN. (D) ALL LINTELS SHALL, BE A MINIMUM OF 8 INCHES DEEP WITH 2 #5 TOP AND BOTTOM FOR CLEAR SPANS LESS THAN SIX (6') FEET; 12 INCHES DEEP WITH 2 # 5 TOP AND BOTTOM WITH 2 # 3 STIRRUPS AT 6" INCHES O/C EACH END FOR SPANS GREATER THAN SIX (6') FEET UP TO 8' FEET. CALL ENGINEER FOR SPANS LARGER THAN EIGHT (8') FEET WITH NO SPECIFIED BEAM OR LINTEL OVER OPENING. (E) BOND BEAMS MAY BE CAST IN PLACE OR CONSTRUCTED USING 8X16 CONCRETE FILLED BOND BEAM BLOCKS. STRUCTURAL WOOD: TO CONFORM TO RULES OF THE MANUFACTURES ASSOCIATION UNDER WHOSE RULES THE LUMBER IS PROVIDED, SUPPLID'\S LABELS AND SPECIFICATION SHALL BE UPHELD. 2. TO BE AIR DRIED, WELL SEASONED AND MARKED AT THE MILL, 3. SPECIES OF WOOD SHOULD BE No. 2 PE-NSE, SOUTHERN PINE, 4. ALL STRUCTURAL WOOD TO BE SURFACED FOUR (4) SIDES (S-4-S WITH A MINIMUM FIBER STRESS IN. BENDING OF 875 PSI FOR 2X12'S AND A MAXIMUM MOISTURE 925 P.S.I FOR 2 X 10'S CONTENT OF 19 PERCENT PER NDS TABLES 5. ALL LUMBER AND PLYWOOD IN CONTACT WITH CONCRETE, STUCCO, MASONRY OR OTHER CEMENTITIOUS MATERIALS SHALL BE TREATED TO COMPLY WITH AWPA STANDARD LP-2. 6. STORE ALL LUMBER ABOVE GRADE OR FLOOR, STACK TO ALLOW PROPER AIR CIRCULATION AND PROTECT FROM WETTING WITH SUITABLE COVER. NEL"M a i71C� 4. HORIZONTAL JOINT REINFORCING SHALL BE STANDARD NO. 9 LADDER TYPE FOR 8" THICK MASONRY UNITS, AS MANUFACTURED BY "DUR-O-WAL", HOT DIPPED G/1LVANIZED, OR ENGINEER APPROVED EQUAL PLACED AT EVERY 2ND BLOCK COURSE (16" VERTICALLY) FOR ALL INTERIOR AND EXTERIOR WALLS. THE JOINT REINFORCING SHALL EXTEND 8" INTO ADJACENT 5. WHEN COLUMNS ARE CONSTRUCTED FIRST, BLOCK AND COLUMN SHALL BE TIED THRU 20 GAUGE GALVANIZED CORRUGATED DOVETAIL SLOTS AND 1 X 5" X 16 GA. GALVANIZED CORRUGATED DOVETAIL ANCHORS AT THE SAME LOCATION AND SPACING AS THE HORIZONTAL 6. WHENEVER ANCHOR BO4LTS ARE TO BE SET IN MASONRY, TWO CELLS AT THE SETTING 7. MAXIMUM POUR LIFT FOR MASONRY UNITS AND GROUT POUR HEIGHT SHALL BE 4'-0". 10. COMPRESSIVE STRENGTH OF UNIT MASONRY SHALL BE MIN. OF 1900 PSI RESULTING IN 11. GROUT SHALL BE CONCRETE CONSISTING OF NATURAL SAND FINE AGGREGATE AND NUMBER 8 OF ASTM C33, TYPE: PORTLAND CEMENT CONFORMING TO ASTM C150. AND SHALL HAVE A COMPRESSIVE STRENGTH (F'C) OF 3000 PSI mol in Di signed by Lisga H Anglin Date: 2021.08.1 8 01:56:29 -04100' E 0 U z 2 � o ,_ CO 1 LLJ LLJ > z LLJLn 0) C� - F w z Lu Q z � w -� >Ln m� ��_ z _ Qzw J w zo=5=' c� Q� z Q --cn= _ W zo Q z Q 0O :Dw 00 ¢ �~ J 00 -1 CL LLJ w 0 SEAL: E N j No:00 3844 STATE OFF �COR IOC 4, 0 NA L L00000�° °000�0p°Dn�„_ Q 0 CE LLJ 0 cf) LL LLJ FF z can f rn LLJ cf) cr_ m LL 0 LLJ Uj 0 LLJ Lij w i H 0 M U C\j LJ Cy) J LL.. Cn W -- U 0 _0 ui DATE: 02-02-20 REVISIONS: M I Ag.Gp M Win, _.u. c c SHEET NO. rM S-100 . `' . O O LO - 1 3 #5 e 4w ♦ d p -,— ' 4 b - °• • ' 4 8 MIL VAPOR 2' 6 e ;• " .­4' BARRIER ♦ d• e THICKENED SLAB EDGE DETAIL TE-30) JA_' 4. - S-2 SCALE: 3/4" = 1'-0" A. " a i 'ei d' °r da 'e < + - ab• ° ,°, .. -•6 '_ e s Q_ - ° ,!d _ - a ad ,: .i1 _d a d•. 'd �< °,`, e„' - d P _ °! d• - -tl' °' t ..°4, ba 4,. a °,_ d' SEE CIVIL SITE PLAN `d =TEA_� a' -FOR RAMP SLOPES SEECIVI•- d °a dAFOR RAd, a A a Q 4'-a ,0 t,•d.4 -WALnYYM-14 °j e a a:� _'.a-°DN 4 P, a�' 4 a' ,. r a „ e ° 51 011 4r FIBRECRETE 1 11 5 -0 ° SLAB CONC. SLAB W.W.F. ON GRADE 5'-011 1'-6" LAP 1 #5 CONY TOP 1 61-411 31-011 2'-3" 3'-211 ; ... _. _.. __ ._... - . -..- SPLICE 2 #5 CONY. BOY. HB PORCH HB 4" FIBRECRETE SLAB = a o WELL COMPACTED ■I I I I LA-■ ■ --- --- ■ ■ ■ ■ ■ ■ FILL 8 MIL VAPOR 16" _ _ - FC" ? �' ♦d _ `, `,C , „�C F� °• se F�' •:_ < . ' F�'^ = ° ��C ° ° d FC d `F,C, ;�,_ • R°F'.0 < ' -�FG 4 a : ^FC ._ PB'9 `+• :: w.- �-• -� ^ = ' = F — r T=' -'+ •� L' �. T, — — — ,'- - -s — -- -e — , ; �"° 4 r -° _= — — —'•-• _ — �! — _ `— -r • e' - — — , — ___:FG r _ tr, a �-r— — — -b r- - —° �— �sT ° — —,"'; — ;— < BARRIER y. - d �O° .6a, "te ., e: I _ d .. e, •,, ♦ - - d > ♦. - -'° •, a; .a _d - - ' >e °� - •Q'• b, - ° _' a`A • ♦d ••a • - f •° ♦ it •, ;Tf -�lU ', _' r .. .,Q tl- a - Ids - rd 4 -°— e e h `COR—CELL <•ia _.. 9 ° • _ e .° _ c =4° >_ j t —. �_•— — — ` — �. — .c ♦ �' °' .; All THICKENED SLAB C° r6°VERY @ -, I ° d •d•. -I J (TYP. @ ALL) (TYP. @ALL) ; e 2 EDGE DETAIL T E -1 6 ) UP , -2 SCALE: 3/4' = 1'-0" I° Rc I'. 1' om N CONT. a, ° •I 4" CONC, SLAB W/6%6" — 10/10 WWM OVER I = W.W.F. CONC. SLAB t VAPOR BARRIER ON CLEAN FILL COMPACTED I C ON GRADE 1'-6" LAP 1 #5 CONT TOP TO MIN, 95% DRY DENSITY. SOIL SHALL SPLICE 2 #5 CONT. BOT. F ° ( BE PROTECTED AGAINST SUBTERRANEAN I : d.• I TERMITES L5 • .x xTx x x x— ♦ �, x t HARD WOOD FINISH @ PLATFORM d J. WELL COMPACTED FILL 16" $ MIL VAPOR ••r 4 .I ELEVATED WD DECK 5 a" PLY FOUNDATION CORNER BARS I T�V: ;I I BARRIER / 1819 .3.1.2 : SPLICES IN REINFORCING BARS SHALL BE NOT LESS THAN 36 I �! ON 2X4 @ 12" 1 1/2" BAR — AND REINFORCEMENT SHALL BE CONTINUOUS AROUND ALL CORNERS SOUND 11 •,; d-'I I ° d UNDERLAYMENT ADHESIVE AND CHANGES IN DIRECTION. CONTINUITY SHALL BE PROVIDED AT CORNERS !. OR CHANGES DIRECTION BOOTH I= •` ; - I THICKENED SLAB IN BY BENDING THE LONGITUDINAL STEEL AROUND 'I I A - !' APPLIED :I THE CORNER 48 BAR K OR BY ADDING MATCHING REINFORCING STEEL. WHICH I" ' `. SHALL EXTEND 48 BA — FROM EACH CORNER OR CHANGE IN DIRECTION. WHEN 4 - I 3 EDGE DETAIL I N T -1 6 ) ,• I (SEE DETAIL ON SHEET S-5) s THREE OR MORE BARS ARE REQUIRED, THE BARS SHALL BE HELD IN PLACE AND ALIGNED BY TRANSVERSE BARS SPACED NOT MORE THAN 4 FEET APART. I +; I '-0" F� , . ;,•°..I S_2 SCALE: 3/4" = 1 -4 6" DIA PVC WIRING SLEEVE BLW SL48 W/ PULL WIREA AL IF 4 . ♦' 4•; . 6" DIA PVC WIRING SLEEVE BLW SLAB W/ PULL WIRE • ,~ h, I SEE ARCHITECTURAL FOR DIMENSIONS ♦ +� �a .I ,I, I ";°•,r I I a AND SLOPES ONSLABS. Y I° Nd- ° da A 2 - #56 ' .. ; 4 THICKEN SLAB BELOW PARTITION ITE=18a•L----------------------------------------- -- —-------------------------- ----------------J' °4 C ■ atl ' ' etl • , ° .-------------------------------------------------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------:.:_�J' CONIC. PM) ------------------------------------------------------------=— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ------------------== `.•e .r-----------------------------------------------------------------------------------------� .fie■ aQ ° ,°- I i d. _1 r. :I4, CT L tl A ♦ 4 ' 171-011 •I a°^, .I 1 41-411 4'-0" I: ap 'y,I , �,, _ - " "° •^.= ;ea • °' •_° / 4 : , y ; e° - C-1 C-1 a r F ♦' a I ; 1,♦ - ,•�I F ".; �� Q' s e ... _------------------------ 'd ..{{II I___ _T, — ; a •-••, - -S` d..° ., • �' — —,— .eT ' , -� �— a _w. — —� — `— g r"� T r- — — —_ .r —•— — — — T —• —,7a — — —.-, ,— T 4 -T e� __ �� . .�.' '♦a ',S �a:21- ,• - ♦° `� t< ' 4' atl - r s �.9 -•,4 ° .e' - d �- d' ,a - -a' �$,- sd, 'a - '° a ,! 4 ° ` _ •° °Q° d e _ '4 •♦ tlP `' ' ° •�_ - '•') '.d -a''A I A' d „_" ,. d d C Fp♦ • d��ad 'Fir- - C ■ ----- � ° ! , ( °` ♦ ;1I II I • ;e° ,•� I I d ■ !A 1= 4- y Ic' = e tll I 4" CONC, SLAB W/6"x6" — 10/10 WWM OVER VAPOR BARRIER ON CLEAN FILL COMPACTED ?, • r I 3.2% Sloq I 0 TO MIN. 95% DRY DENSITY. SOIL SHALL RAMP DOWN ' ( BE PROTECTED AGAINST SUBTERRANEAN I 1 1 Al co I I I I I I TERMITES '.I ., :i I• .� I 4"' FIBRECRETE j FLAIL SLAB 11 : ' 1 -4'l` ■ 'F},.JE =- „'.1. - REFE d B DTL LO _ Cher _ r �, I `� , I ■ ■ I ■ i slope ' �0 2'x2' COL @ 4 i I 11611 DIA 12 COLS ( 51 -0 1 3.2 /o I I I I CORNERS (W 4 I I I I I I #5 VER,) c-1 3'-0" 5'-611 5'-61 31-0PIER WALK EDGE - — - — - — - — - --- ---------------- FOUNDATION PLAN DWN TO TOP OF slope — -- 1 /4 - 1 -0 2'-0" 21-611 17'-0" 26'-011 10'-011 19'-011 � - Cq N Z. w (n I� E ,♦ o L Lisga "�..}} O N O CO >> LL CO>, Z W 0 U Q0 (1) W I' o r� z Ln z �J < ZF>— l �a- W W cn J o —I > m IJ`- L,,J z � _ J w = An g I iz=�� QIL c� I CD� Q J = = z z l I Q (!� 0 00 Q W E _ `r —J H UJ —J w W —J W O Digitally signed by L i s g a H SEAL: �o�°p°pp°p0pp°°G ouH o0000000aea000°p°° Anglin 0�0� E N / o Date: No.00 3844 2021.08.1 �* °$-� -za- %� STATE OFso o 01C % (� P a .4 J F� O Rw� -04 100 °OpOpOp°0p°� ��o0a NA p p000 0°00°fig J Q 0 Q LJ LL 0 Cf) I__L L.L1 V z � W �J L� U-- U W UD O U LJ W � 11:1.11V 110-yo z O C'7 U N LLJ Cy) U cy) H W -- U 0 O W Q 0S G LLJ LHA DATE: 02-02-20 REVISIONS: � a nE i t'1 wDE ,.FL SHEET NO. OF an O d- Lo 75'-0" L5 L5 PERFORATED ALUM. SOFFIT g' VENT, -- I 11 I I —77 11 1 I I I I I I I I I I 1 I I I I I I. I I 11 I I I I —�--- -------- � 1c/) 1 II i I L1 I I I I 1 I I I I I I I I I I I I I I I I 11 I I 1 ------- ------ -- --- �-------------y�� I ------------------ ------------ ;\ 'Cn 1 V 1 I I I 1 I I 1 I I I 1 I I I I I 111�---------------------' -- --- ------- -------------- 1 I I 1 I I I I I I I I I I 11 I � �I 1 I I = 1------------------------� I I I I I I I 1I I I I I I 'I I I I I I I II ;------------------------- --- --7---7---7---7---7---7--1 i I I I I _�_—_---_—_—_—_—_--___-_-_ --- +--------------------------I I I 1 I I I I 1 1 --- i I I I I 1 I 1 I I I I I I --- �I� L I I I 11--------------------------I ----------------------- i 1 1 I 1 GAB(E ABi✓ SEAT INC' 1 1 1--- I� � 1 ' --1--- -- --- --- 1 -- I —I— ' '---i—I----I I --- ----------- -- -,-- ----- - - - -I- - - - ---�, I-I----I----I----1-- I I I- I -I--- 1---I----I--- I I I ----I-- 1-�------------------_------� , � I I ( I I I I I I I I I I 15/8" GYP Bd CL(; — ----��----------------------- -;-- I I I I I 1 I I I SANCTUARY- — - — - — - — - — - — - — - — - - — - — ��--- ��I i BYILDINGiRIDGE I LINE.-�-----------------_------ --- --- -----------------------—-- \v� 16 O/H I 16" O/H —I I ' ' 1 I i----,-----------_------Y -------------------------�---I I I I i 1 I RIDG I I I I I I I I --- I ' I I I I I I I El I I I 1 I I I I I I I I I I I ---�----------------------- I i i i 1 I SCI,ISSOF, S TR6SS AkV I I I I I ! - -'�------------------------I ; i I i 1 I I 1 I SANQTUA�Y I 1 --------------------------- ! --� I I ! I I I I I I I I I I-------------------------t1 --- ---�------------------------I-;--------------------------- \I I I I I I I I I 1 I Gl --- --- ' I 1 I I I b i ------------------ - — - — - — - -; I I i I i I 1 ------ --- I b l I lb I �� b I b I i b lb ., — - — - — - — - — - — - - — - — - — - 1 I I I I I I I I I I I 11 , �� - — - — - — - — - — - — - — - — - — - 6 -8 I I I I 1 I ---------- -- I I I I I III ' ( I I I -�1 I I I ( I n I I 1 1 ---�------------- --- i 1 i i �-------------- -- i----------=------� -- 1 I ( i�l I i ' ---------------- 1 I I 1 I I I i i i i i "'------------- -- I - — - — - — - — - — - — _ — - — - — — - I I I I I 11 I I I I � II \�------- I I I I I I I I I 1 I I I I I III I - — - — - — - — - -- DS --- fit- I I I I I i I i---------------------- ' I I I I I i I i � •� I I I I I !� I I I I I __ � L1 I I I I I I I - — - — - — - — - — - — - — - — - — - — - — - — - — — - --------------------------- -- II�—�--- I ----------------------------- �`,i�Y._1 2 12 � 2 ! 2 ! 2 12 12 12 12 12 i2 1 2 1 I I I 1 i I � 1\ I I 11 1 I I \ — — — - — - — - — - — - — — - — - — - — - — - — - — — -� L2 L2 12------------------------- — ,2 L2 -------------------------- -- CL2) I I 2 I - - — - — - — - — - — - — - — - — - — - — - — - -- -- I I 2 I ROOF FRAMING PLAN 51'-0" L2 1 A LINTEL 2' RECTANGULAR CO UON k CAP W/ 4 #6 VERTI BEND INTO 8.2e PRESTRESSED LINTEL MIN 36" OVERLAP 16- ROUND CON 'EE COLUMN W/ 4 VERTICAL. 3000 S CONCRETE 2' RECTANGULAR CO MN BASE W/ 4 #6 VE 3000 PSI CONCRE 1 o co -I N WELL COMPACTED FILL 2•-6•• 8 MIL VAPOR BARRIER COLUMN DETAIL (C 1) SCA_E: 3/4 = 1'-0" 21'-8" L7 2, 21 2 2 2 1 2 2 2 2 � 2 1 1 C � i s c I I I I I I I I I c c I I I 1---------- , -----------I I ( I C 1 1 C ' E- — - — - — - — - — - — - - — - — - — - — - — - — - 1 1 c C I 1 - — - — - — - — - — - — - - — - — - — - — - — - — - 1 -� I I c I----------- i c I I I I i ----c--I — 1 c �- % 1 I 1 I I I -- I � I I I ► I I I REF DTL BELOW 28'-4" E 0 U O 6 O ,, Z c� L Lis_ Qi C� W w � U Cfl a � Ln — 0M� Lu W cn � Lil = z=~J Q'L C� I- Q e = w� o =d LL ::D U U Ang,lin 0-O00 Q W _ 4 J W J00 J LL n O v ^ CL7 VA SEAL: °°p°°ppp0°UV V G H A -YV °0p0p°0®oo E N pN0.00 3844 STATE OF "` O R 1 o°pOp0p0nn�/ O V A L \p00pp0p4° J Q 0 Q I� I-- Lu z f- =D CE 0 c')0 UD U N LL w w to C� CC U cy) z_ c J — LL ® F. - -� U) W C) Co m CC 0 w CC) LL CL W UD (J- z O Q CJ Q � w � W r. v Lij I— W Q CL DRAWN BY: LHA DATE: 02-02-20 REVISIONS: d 2 4 Juav �j tJ "n SHEET NO. OF Sml 02 GENERAL STRUCTURAL NOTES A. REFERENCES 1. FLORIDA BUILDING CODE 2020. 2. ASCE 7-10, V = 180 MPH, CATEGORY 3, EXPOSURE "C" K=0.85 B. GENERAL 1. THE CONTRACTOR SHALL FIELD CHECK ALL DIMENSIONS ON THE STRUCTURAL DRAWINGS AND VERIFY SAME ON THE ARCHITECTURAL SET. ARCHITECTURAL DETAILS SUCH AS; SLAB DEPRESSIONS, WATERPROOFING, CURBS, MECHANICAL OPENINGS, FASCIA FRAMING AND BRACING SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL SET. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND BRACING TO ENSURE SAFE WORKING CONDITIONS AT ALL TIMES. ALL CONSTRUCTION SHALL CONFORM TO THE FLORIDA BUILDING CODE. C. CONCRETE 1. SHALL BE A MIX DESIGNED IN ACCORDANCE WITH A.C.I. 301 TO ACHIEVE A 28-DAY COMPRESSIVE STRENGTH OF 3,000 P.S.I. AND A SLUMP OF 4"_ 2. TRANSPORTATION, PLACING AND CURING OF CONCRETE SHALL COMPLY WITH A.C.I. 318 BUILDING CODE (LATEST EDITION). 3. ALL CONCRETE STRUCTURAL COMPONENTS SHALL HAVE CONCRETE STRENGTH TESTED IN ACCORDANCE WITH A.S.T.M. STANDARDS, F.B.C. 2010, AND A.C.I. 318 (LATEST EDITION). TEST CYLINDERS MUST BE TAKEN EVERY 50 CUBIC YARDS ON CONCRETE PRIOIR TO PLACEMENT. TESTING LAB SHALL PROVIDE COPIES OF CONCRETE TEST RESULTS TO ENGINEER OFFICE FOR REVIEW. 4. CONCRETE MIX DESIGN SHALLBE SUBMITTED TO ENGINEERS OFFICE FOR REVIEW. 5. CONTRACTOR SHALL CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE. 6. UNLESS OTHERWISE NOTED ON PLANS, MINIMUM CONCRETE COVER TO REINFORCING STEEL SHALL BE MAINTAINED IN ACCORDANCE WITH ACI 318. SPECIFIC CONCRETE COVERS ARE GIVEN IN THE FOLLOWING: FOOTINGS: BOTT. = 3" CLEAR TOP = 2" CLEAR TO TIES SIDE = 2" CLEAR TO TIES SLAB ON GRADE: BOTT. = 2" CLEAR WHEN POURED ON 6" MIL VAPOR BARRIER TOP = 1 1/2" CLEAR COLUMNS & BEAMS BOTT. = 1 1/2" CLEAR TOP = 1 1/2" CLEAR SIDES = 1 1/2" CLEAR 7. EACH CUBIC YARD OF CONCRETE SHALL CONTAIN A MIN. OF 5 BAGS OF CEMENT. 10. CONC. DESIGN MIX SHALL BE REVIEWED & APPROVED BY ENGINEER OF RECORD PRIOR PLACING ANY DESIGN MIX. D_ REINFORCING STEEL 1. SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND CONFORM TO A.S.T.M. A615 GRADE 6D. 2. ALL ACCESSORIES SHALL HAVE UPTURNED LEGS, AND BE PLASTIC DIPPED AFTER FABRICATION. ACCESSORIES FOR REINFORCING SHALL BE INSTALLED IN ACCORDANCE WITH A.C.I. 315 (LATEST EDITION). 3. SUPPORT BARS SHALL BE #5 OR GREATER AND NOT SPACED MORE THAN 4'-0" O.C. SUPPORT BARS AND ENDS OF MAIN REINFORCING SHALL NOT EXTEND MORE THAN V-8" PAST OUTERMOST CHAIR OR SUPPORT BAR. 4. A MINIMUM OF 3 SUPPORT BARS AND 3 INDIVIDUAL HIGH CHAIRS FOR EACH SUPPORT BAR SHALL BE PROVIDED FOR TOP REINFORCING. 5. ALL PLACEMENT OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE OF THE CONCRETE REINFORCING STEEL INSTITUTE. 6. PLASTIC TIPPED COLUMN SPACERS SHALL BE PROVIDED FOR VERTICAL COLUMN REINFORCING STEEL, SUCH THAT A 2" MINIMUM CLEARANCE IS MAINTAINED. E. STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING GRADES: a. ALL WF, ANGLE BASE PLATES, CONN. PLATES (UON) -------ASTM A36 (FY=36 KSI) b. STRUCTURAL TUBE----------------------------ASTM A500, GRADE B (FY=46 KSI) c. STEEL PIPE ---------------------------------ASTM A53, GRADE B (FY=36 KSI) d. ANCHOR BOLTS (U.O.N.)-------------------------ASTM A307 2. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, CORROSION PROTECTED & ERECTED IN ACCORDANCE WITH THE AISC CODE OF STANDARD PRACTICE, LATEST EDITION, EXCEPT AS MODIFIED IN THES ENOTES. PROVIDE IN SHOP ONE COAT OF RUST INHIBITING PAINT FOR ALL EXPOSED STRUCTURAL STEEL. 3. ALL EXTERIOR COLUMNS, BASE & CAP PLATES SHALL BE HOT DIPPED GALVANIZED AFTER 4. ALL ANCHOR BOLTS, HEADED STUDS SHALL BE HOT DIPPED GALVANIZED EXCEPT THAT EXPANSION BOLTS SHALL BE HILTI KWIK 3. 5. CONNECTIONS SHALL BE BOLTED/WELDED AS SHOWN ON PLANS. THE FABRICATOR IS RESPONSIBLE FOR THE DESIGN OF CONNECTIONS NOT SHOWN ON THE DRAWINGS. GENERALLY, CONNECTIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE SCHEMATIC AND ARE ONLY INTENDED TO SHOW THE RELATIONSHIP OF MEMBERS CONNECTED. 6. GROUT FOR COLUMN BASE PLATES SHALL BE NON -SHRINK, NON-METALLIC GROUT SUCH AS MASTER FLOW 713, AS MANUFACTURED BY MASTER BUILDERS OR APPROVED EQUAL (5000 PSI) 8. ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION. TOUCH-UP IN FIELD AT WELDS AS REQUIRED. F. WELDING ALL WELDING TO BE DONE BY CERTIFIED WELDERS. WELDING SHALL BE MADE WITH E70XX ELECTRODES AND CONFORM TO THE CURRENT RECOMMENDATIONS OF THE A.I.S.C. AND THE AMERICAN WELDING SOCIETY. G. MASONRY 1. CONCRETE MASONRY UNITS SHALL COMPLY WITH THE PROVISIONS OF THE STANDARD SPECIFICATION FOR DESIGN AND. CONSTRUCTION OF LOAD BEARING CONCRETE MASONRY, NCMA TR-75B AND ACI 530.1. 2. HOLLOW MASONRY UNITS SHALL CONFORM TO ASTM C-90, TYPE-1, "STANDARD SPECIFICATIONS FOR HOLLOW LOAD BEARING CONCRETE MASONRY UNITS" 3. MORTAR SHALL CONFORM TO ASTMC-270, TYPE 'M' WITH A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI. ON THE NET AREA. 4. HORIZONTAL JOINT REINFORCING SHALL BE STANDARD NO. 9 LADDER TYPE FOR 8" THICK MASONRY UNITS, AS MANUFACTURED BY "DUR-O-WAL", HOT DIPPED GALVANIZED, OR ENGINEER APPROVED EQUAL PLACED AT EVERY 2ND BLOCK COURSE (16" VERTICALLY) FOR ALL INTERIOR AND EXTERIOR WALLS. THE JOINT REINFORCING SHALL EXTEND 8" INTO ADJACENT COLUMNS. 5_ WHEN COLUMNS ARE CONSTRUCTED FIRST, BLOCK AND COLUMN SHALL BE TIED THRU 20 GAUGE GALVANIZED CORRUGATED DOVETAIL SLOTS AND 1" X 5" X 16 GA. GALVANIZED CORRUGATED DOVETAIL ANCHORS AT THE SAME LOCATION AND SPACING AS THE HORIZONTAL JOINT REINFORCING.LED IN 6. WHENEVER ANCHOR BOLTS ARE TO BE SET IN MASONRY, TWO CELLS AT THE SETTING LOCATION SHALL BE FILLED WITH CONCRETE. 7. MAXIMUM POUR LIFT FOR MASONRY UNITS AND GROUT POUR HEIGHT SHALL BE 4'-0". 8. SLUMP 9" + 1" FOR GROUT 9. REFER TO ADDITIONAL REINFORCING NOTES ON FLOOR PLANS. 10. COMPRESSIVE STRENGTH OF UNIT MASONRY SHALL BE MIN. OF 1900 PSI RESULTING IN f'm = 1500 PSI 11. GROUT SHALL BE CONCRETE CONSISTING OF NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO GRADING SIZE NUMBER 8 OF ASTM C33, TYPE: PORTLAND CEMENT CONFORMING TO ASTM C150. AND SHALL HAVE A COMPRESSIVE STRENGTH (F'C) OF 300D PSI AT 28 DAYS. J. BRACING 1. THE FRAME SHALL BE BUILT TRUE AND PLUMB AND TEMPORARY BRACING SHALL BE INTRODUCED WHEREEVER NECESSARY TO TAKE CARE OF ALL LOADS TO WHICH THE STRUCTURE MAY BE SUJECTED. INCLUDING EQUIPMENT AND OPERATION OF SAME. SUCH BRACING SHALL BE THE REPSONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL BE LEFT IN PLACE AS LONG AS REQUIRED FOR SAFETY. am"I AlN 1. WOOD MEMBERS IN CONVENTIONAL FRAMING SHALL HAVE A MINIMUM ALLOWABLE (BENDING STRESS OF 1,200 P.S.I.; MINIMUM ALLOWABLE SHEAR STRESS OF 175 P.S.I. AND MODULUS OF ELASTICITY OF 1,700,000 P.S.I. AT 19% MOISTURE CONTENT IN ACCORDANCE WITH A.I.T.C. STANDARDS. 2. WOOD MEMBERS SHALL BE SOUTHERN YELLOW PINE P.T. #2 DENSE WITH A 19% MOISTURE CONTENT. L. SHORING 1. FORMS AND SHORING FOR CONCRETE SLABS AND BEAMS SHALL BE DESIGNED TO WITHSTAND THE DEAD LOAD OF CONCRETE AND THE ANTICIPATED CONSTRUCTION LOADS. 2, WHEN CASTING A SLAB, THERE SHALL BE SHORING BELOW IT CONTINUOUS TO THE GROUND. 3. IN NO CASE SHALL SLAB AND BOTTOM BEAM FORMS BE STRIPPED EARLIER THAN 21 DAYS AFTER PLACEMENT AND UNTIL THE COMPRESSIVE STRENGTH OF 2,200 P.S.I. (FOR 3,000 P.S.I.) AND 3,200 P.S.I. (FOR 4,000 P.S.I.) HAS BEEN ATTAINED. 4. THE SYSTEM OF SHORING SHALL BE INSPECTED AND APPROVED BY THE CONTRACTOR'S SPECIALTY ENGINEER PRIOR TO INSPECTION OF BY THE THRESHOLD/SPECIAL INSPECTOR. 5. DESIGN AND CONSTRUCTION OF FORMWORK AND SHORING SHALL COMPLY WITH THE A.C.I. 318 BUILDING CODE (LATEST EDITION) AND BE ENTIRELY THE REPSONSIBILITY OF THE GENERAL CONTRACTOR. 6. SHORING DRAWINGS SHALL BE PROVIDED BY GENERAL CONTRACTOR AND SHALL BE DESIGNED, SIGNED AND SEALED BY THE CONTRACTOR'S SPECIALTY ENGINEER REGISTERED TO PRACTICE IN THE STATE OF FLORIDA. N OTE SOIL TO BE TERMITE TREATED AS PER F.B.C. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BLDG. DEPT. BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES & LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." SOIL STATEMENT SOIL AT THIS SITE IS SAND & ROCK ADEQUATE TO SUPPORT THE DESIGN LOAD OF 2000 PSF. AFTER EXCAVATION SIGNED AND SEALED LETTER WILL BE SUBMITTED BY THE ARCHITECT OR THE ENGINEER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED ON. PLAN NOTES : 1. PLACE ALL CONC. SLABS OVER 6 MIL. VAPOR BARRIER OVER TERMITE TREATED, CLEAN & WELL COMPACTED FILL. 2. ILI-n DENOTES 8" MASONRY BEARING WALL REINF. W/ #9 GALV. LADDER TYPE HORIZ. JOINT REINF. @ 16" O.C. 3. FOR VERTICAL REINF. SEE FLOOR PLAN. ADD 1#5 CORNER BAR @ TOP & BOTT. OF BEAM 90' HOOK AT ALL TOP BARS BEAM BARS SEE SCHEDULE (TOP PLANE SHOWN) TYPICAL- BEAM CORNER PLAN DETAIL_ SCALE: 3/4" = 1'-0" ADD 2 # 5 REINFORCEMENT BARS FOR EVERY 8" OF DROP #3TIES @ 8" a' ea' °4 a :a •'� a 'ate' I e DROP TIE BEAM i @ WINDOW AND DOOR OPENINGS DROP TIE BEAM TIE DOWN SCHEDULE (SIMPSON) ITEM GA LENGTH FASTENERS UPLIFT 2 HETA 16 16 12" EMBED / 10 - 1 Od X 1 1/2 1810 b LTT208 12 19 3/4" 1/2" dia BLT @ TOP PL W/WJHRS / 10-1Od X 1 1/2 1750 c H14 18 7 3/8" 12- 8d 1 1/2 (TRUSS) / 15-5d 1350 1 8" EXTEND DROP OF TIE BEAM 8" BEYOND SIZE OF OPENING AT EACH END OPENING FOR WINDOW, DOOR OR SLIDING DOOR. SEE FLOOR PLAN & ELEVATIONS PRESTRESSE LINTEL LINTEL SCHEDULE 12" - 8" I I 2-#5 USE BEND TO TOP STL COMP BM BRIG (4" BENDINTO BOT (MIN 36" LAP) 2" 3 3/4" 61/4" GROUT FILL CALL (TYP) PRECAST CONC. LINTEL 3 #6 VERT EXTEND INTO BM BENDS. TIE TO TOP STL BM (2) TO BOT STL BM (1) " "„ �W BM W/ I U UD 03'-5 NATE OPPO) COL W� 3\#6 VERT. BEND 'RESTRESSED CONC. L VV/ MIN 36 LAP 'TUCCO (SAND FIN) '2" 'PW W/SF LATH =RM COR BOX DTL) 0 TYP CORNER DETAIL (ATOTAIL) 3/4 - 1-011 MARBLE SILL AL FIRM WNDW 1 X 4 BUCK m � Q I-LIJ \ Q #5 INFILLED CELL REF c� ° FLR PLAN FOR LOC'N 0 - _ 16" dia FILL 1/2 COL 4 X 6 CER TILES (METALLIC GRN) #6 VERT @ 5/8" STUCCO ALL O.S CAST STONE BASE CAP CORNERS COLLAR (REF ELEV) D DTL @ 1/2 COL BASE & CMU R.EINF'G 3/4" = V-0" LINTEL MR I LENGTH I SAFE GRAVITY LID L 1 PC 4'-6" 1789 PC L2 5'-4" 1223 L3 PC 6'-6" 1255 PC L4 V-4" 1210 CL5) PC 9'4' 3138 455 L7 PS 1 7'-4" 1400 9 GAUGE DUR-O-WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE 16" CONC. J ITS TYPICAL DUR-O-WALL AT CORNER SCALE: N.T.S. DETAIL LINTEL SCHEDULE SAFE UPLIFT LID BM COMPOSITE/ REINF 8X8/1T 1660 1393 8X8/1T 1141 8X8/1T 1269 8 X 2 0 / 1 T 1978 8X8/1T 548 8X8/2T 851 12 X 20 / 213; 2T ^ ^^` 5/8" PLYWOOD TRUSS PLYWOOD SHEATHING CONTINUOS UNDER PIGGY BACK RT 14 (10) 16D (TYP.) BY UNITED STEEL PROP. CO. U=755# NOA= 12-0130.33 >-'� ATTIC VENT 20' X 20" HOLES IN SHEATHING UNDER SECONDARY TRUSSES TRUSS CONNECTION FOR PIGGYBACKS SCALE: 3/4" = V-0" E o Lisga o � CO CO 6 T @) zt� -J W > z LLJ Ln - H 0 w W U > m LJ � D w -J J 1 19 1 <2~J -- z O 0=u� a��- U� ct� -: V)= Q z = w= o =Q O 00 < LLJ uj __j 0 DI hall g Y signed by L i s g a H SEAL: ®0 ®oaaaaaa000000aaaa0000OQ0p0pBp0o Anglin H °o°°p°°p° o® �QQ0000 Date. No.00 3844 2021.08.1 0* 0 -1 -21- -�3 STATE OF o 0 01:5 9:3 0 ooPF� OR F0 1 1 O°BOOOOGpO e o0 0 N A L aa�NppO°°°°°o°goo _ 0 4^ 0 ! I 00068000000 ooaoa Q (D Q w z Ef 0 c')0 UD C) N L.L_ W W (1) ry- 0 M Q -� cn LLJ - C) m � 00 � LLJ W CL W C!� LL z O o U C Q G W LLJ W i CL DRAWN BY: LHA DATE: 02-02-20 REVISIONS: SHEET NO. mi ow m ,4,-n" (8d @ 4" O.C. @ PW DECK) 2X8 CONT 5/8" PW ROOF DEC 2X6 CONT W/ 8d @ 6" 0. C. 4X4 MTL (80H) EDGE META 1 0 24" = VINYL SCRN 1/2" PLYWOOD SOFFIT W/ 4 X 24 OPNG @ 48" O.C. 12 5 PRE-FAB WD TRUSS @ 24" O.C. 9" THK (R30) BATTS �,e_ ca►� 1/2 PW CLG TIE BM CONT 8X16 W/ 2- #513 / 2- #5 T / 2- #5 MID. TIE TO VERT STL @ =r— WALL NOTE: VERT TO TOP PLATE (� PART'N (1/2" AB)+ 10 -16d (1750) C4S 2X2 NAILED TO VERT TRUSS - 16d@12" O.C. 6" BATT SHOWN FOR CONCEPT & TIE DOWN ONLY ENGINEERED TRUSS DGS SHALL TAKE PRIORITY 2X4 E 2 LAYERS 5/8" TYPE 'X' 48" FIRE ROCK +10'-0' CLG. 9" (R30) BATT 8" BOND BEAM (U-BLOCK � III uyv W/ 1 #5 CONTINUOUS) ��-_ + 12' -0" -_ — - — BAG -- +71-4" J SPG @ 48" + 24" W 1/2 G JO.C. @ SPRG (FOR - { SOUND) FURR DWN @ PULPIT GUM 0'-0" F F 0 1 '-4" 1/2" GYP BD ON 1X FURR'G @" O.0 VV/ INSUL BD ( 1/2") SPACES (FOILED FACED) -1-5 INFILLED CELL @ 48" OXM IN LAP = 32" 6" WD BASE #5TOP 245 BOT (O.S. BAR 0 CONT) VINYL VAPOR BARRIER G TYP EXTR WALL SECTION 9" (R30) BATT +10'-0" CLG SUSP. AC TILE @ CLG 5/8" GYP BIRD "TYPEX" OVE IPA2YWOOD SHEAR JHEET (16d @ 24" O.C.) (UL 419) �2#5 CONT 1'-4" SANCTUARY F \ 1 HR RATED / L.B. PARTION \ 1" = 1'-0" FF E 0 Lisg' o z � O F CO T g" PLYWOOD ROOFo) w > CDuQ� z W DECK W 7@ 4 O.C. z o o w Q CD z� L-Li rn � m � 0- LLJ z SEE ARCHITECTURAL • � > - _j w DRAWINGS FOR ROOFING z Q CD COMPOSITIONngi � _ Q 8 PLYWOOD ROOF DECK Q LJ � Q _ 12 W/ 8D @ 6" O.C. L o u Q n O CO Q � UJ META 16 TIEDOWN - a_ J Q 04 METAL Lw J W a6 EDGE 2x6 CONT D I I to I I Y, 0 PREFAB WOOD TRUSSES 24" O.C. �nnnnnn��nnn�nn� 2x8 CONT 51 (�bly n e `" TRUSS ISUL'N ACROSS ID FILL FOR SOUND BTWN PASTORS OFF, OL BOOTH, MINISTRY GB EA FACE 2X4 @ 16" NOTE: SOIL BEARING CAPACITY ASSUMED -2000 PSF /E TYP INTR PART'N — i 1" = 1'-01, SHOT TO SLAS @ 12" 1/2" TYPE 'x' DRYWALL CEIL. OPT--J/ 1"x3" FURR. STRIPS @ 16" O.C. 1"0" P.T. FIRESTOP @ MIDPOINTS @ CEIL. 16"x8" TIE BEAM W/2— #5 CONT. BOT, 2— #5 CONT MID, 2— #5 CPNT TOP & 2— #5 60" LONG CORNER BARS BENT 30" E.W., 4— #5 TIES @ 12" D.0 @ CORNERS„ 'BALANCE @ 48" O.C. HORIZONTAL LADDER REINFORCEMENT EVERY OTHER COURSE 1/2" DRYWALL ON 1"x2" P.T. FURRING STRIPS @ 16" O.C. W/ R-4.1 INSULATION BETWEEN FURRING STRIPS. 1 "x2" P.T. FIRESTOP @ MIDPOINTS @ CEIL. #5 VERT IN GROUTED CELL @48" O.C. & EA. SIDE OF OPENINGS 36" OR LARGER W/ MIN OVERLAP TO STUB 480 OR 30" 4" PRESSURE -TREATED WOOD BASE 4" CONC, SLAB W/6%6" - 10/10 WWM OVER 6 MIL VISQUEEN OVER CLEAN SAND FILL COMPACTED IN 6" LIFTS TO MIN. 98% OPTIMUM DRY DENSITY AS PER AASHTO T180. SOIL TO BE PROTECTED AGAINST SUBTERRANEAN TERMITES AS PER F.B.C. 1816.1.7 #5 TOP CONTINUOUS 2 #5 " BOT CONT VINYL VAPOR BARRIER LI g a H SEAL: o a o A l l n p°aoaofloflaaaoa000aaaaaaaaon�o G "E q " °°�°°°°°°°�o �� a 0 g pppp°°°°°°°°� \ N S �% o � o 0 a o D t e. o0 ° No. 00 3844 �° C� 20 2 -0 1.08.10 * 08-1 —2-1 �o �� STATE OF �o 2.01. 7 0 �c �� OR I OP °90�00° 8 VINYL SCREEN —0 • • 00i <^ U ow000000000�^ `—\p°°p°p4 °°°°00poaONAuuuooanoo�°N 2" PLYWOOD SOFFIT W1 4x24 VENT @ Q 48 O.C. 1'-4" 3/4" STUCCO FIN. ON B" CONIC. BLOCKWALL W/No. 9 LADDER TYPE HORIZ. JT. REINF. @ 16" O.C. 0 Q z C ~ w z � z 0 c') CC 0 C!) U N LL w w DC U M z c �- LL J m � W 0 U CK 0- w cn LL z 0 Q U Q � w z W ��! U � W z DRAWN BY: LHA 0-0" FF DATE: 02-02-20 00 REVISIONS: d- I 4" THICKENED EDGE MONOLITHIC SLAB TYP EXTR WALL SECTION G 1" = 1'-0" SHEET NO. OF owl