HomeMy WebLinkAboutEMF -5 V-MAX PRODUCT APPROVAL.pdf(1) 4/2'U2021 Florida Building Code Online
SCiS Home Log In User Registration Hot Topics Submit surcharge Stats&Facts Publications contact us BCIS Site Map Links Search
'I Product Approval V ��y
dbpr { �= USER:Public User
5rtV
Product Approval Menu n goRcarion Search n Appllc:tiur,Wi,[n Application Detall
FL# FL17022-R9
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Porna Drive
Palm City,FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally,PE
Validation Checklist-Hardcopy Received
Certificate of independence FL17022 Rg COI 26ga—VMAx_pLywood,W
Referenced Standard and Year[of Standard] StAndprd ear
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
httnt•Ilfinrirtahi iNriinn nmInrinr ann rill acnr7narnrn=wr,r—N/XC.]wtnnv9 PtnnHnr-n.A,nn71,A4l ICZ [POLos,77Pn-il 0a?l.,ee,.4..10 .,,1„A or-o.lor.0A a-
4,`n12O21 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 12/16/2D20
Date Validated 12/16/2O20
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summery of Products
FL# Model,Number or Name I Description
17022.1 111: 26ga VMax on Plywood 26ga(min)VMax 5V panel with 24'coverage on 15/32"(min)
plywood or 3/4'(min)thick Wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12022 R9 11 26ca VMAX gly tl tlf
Approved for use outside HVHZ:Yes Vedfied By:David Eng,PE 81322
Impact Resistant;N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-228 Evaluation Reports
Other:Refer o evaluation report. FL12O12 R9 AE 2fi0a VMAX alvwootl.otlf
Created by Independent Third Party:Yes
17022.2 02:032 Aluminum VMax on Plywood Nominally 0.032'aluminum(or thicker)VMax 5V panel with
21-coverage on 15/32'(min)plywood or 3/4'(min)thick
wood plank.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R9 11 032 VMAX 211n olvwaatl.odf
Approved for use outside HVHZ:Yes Verified By:David Eng,PE 81327
Impact ResistanC N/A Created by Independent Third Parry:Yes
Design Pressure: +N/A/-16B.5 IEvaluatlon Reports
Other:Refer to evaluation report. FL17022 R9 AE 032 VMAX Im plylagaiA df
j Created by Independent Third Party:Yes
17022.3 03: 26ga VMax on Plywood 26ga(min)VMax 5V panel with 24-coverage on 15/32-(min)
plywood or 3/4'(min)thick wood plank.Option for fasteners In
the Flats and in the ribs.
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL17022 R9 11 260iI_-VMAX_plywootl fiats.otlf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81322
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-114.25 Evaluation Reports
Other: Refer to evaluation report. FL12022 R9 AE 2figaa VMAX dy XoQd fi d,,,Qjf
Created by Independent Third Party:Yes
12022.4 09: 26ga CorMax on Plywoe0 26ga(min) )CorMaxplywood
d or 3atetl panel with Woos" lank. eon
15/32"(min)plywootl or 3/4'(min)thick wootl plank.
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL12022 R9 11 2fioa CorMax Plvwoatl HVH2 otlf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81322 j
Impact Resistant. N/A Created by Independent Third Parry:Yes
Design Pressure: +N/A/-161 Evaluation Reports
Other: Refer t0 evaluation report, FL17022 Re AE 2§.ga CarMax PIVWootl HVH2.pdr
Created by Independent Third Parry:Yes _
17022.5 05: 269a CorMax on Battens 269a (min)CorMax carrugmed panel with 29.5-coverage on
2.4(min)battens.
Limits of Use Installation Instructions
Approved for use In HVHZ: No F IZQ22_R9 13ga CorMax Battens otlf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81322
Impact Rhou stanti N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-I61 Evaluation Reports
Other:Refer to evaluation report. F 12022 R9 AE 2fioa CorMax RathenessrLdf
Created by Independent ThInd Parry:Yes
00
iman us;:zam elan smn<aaaE.n i.naa-n n son Pear e.esona�asoa
me sure afrarwaisan Aveto employer.gypnmhesnm-zaun :; ::all sue
urcon
crow ours.W.,wsm admen.ea as pualc remm...1,da—sour I--man—1 maims m repass a a wH..yi so na seae as locos
mall m mk may.know.clean the NPa by prone P W madis rel mail,avail na ve am aueuam,Neax meta¢asoAa2.Ises.•eow.am a semen,s55.27n u,
taMa Norea s ,eaMlve ocmter 1.2012,M[Mren Il..pnptt as5,I.S.man PONE,ae isepaoaenr Men as email asones it m,,Nve one,me my,
hgps:/IOodtlabuilding.orglpdpr_app_OB.aspX7PeremavGEVXOWID9V28BGOHDOOe6rMZMKUEOR%2b7ZBaaisB9inMvmlwawl vAuanapan an
4Rl Y2021 Florida Building Code Online
promded may be used foromdal communication with the Reuters.However emaR addresses are public random.If you do rem wlsb to auppry a personal add—,pease
pmvma the Depertmate wIM ea email eddm.wmN can be made awalabie to Me public To detamAne If you art a limner under[haprer455,F.S.,please cadcod¢.
Product approval ar.epr.r
Credit Cam
Safe
hVIIJ/fioridabuilding.orglpr/pr app dg.aseX70ammwGEVXQw DUV2aBO0H000eBrMZMkOEOR%2b MZ ic82inWilliarwm on%sa%ad vc
MAX
FL17022. 01-R8
p //M64
EXTREMEMETAL
FABRICATORS
S rLLEOCRA RS06nfCFit sPP lNG cvSfFn,S
26ga ( min) ✓ MAX over 15/32" ( min) plywood
Extreme Metal Fabricators
2120 SW Poma or I Palm City FL 34990
Product Description
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/8".
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #2061 Gainesville FL
FL PE 81377 1 FL CA 33344
p w.T mberLak a Cov_g,corn
\D I E I Fy''•,
%r ENS
le •.G
Davie E Eng =202010.03 NO.81377
-
Ones 33.01-60c
, o STATE OF (V=C(�
. .p
G
RCORIDP . ' \
(�S ' ...........
70NAL EN ON
Crimpand assets by D.E.Eng,PE,on me
date indicated.Printed copies of this
donument am not considered!signed
VMAX and sealed!and the slitnature must be
wnfied an any electimnic copies
Exposed Seam
MAX
FL17O22.O1- R8
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required-
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
.5e f Pattern at ^ o.e.. 86 PSF
Method B- tt pattern at 1 ^ o.c.: 93.5 PSF
Method C• # O 8^ o.c.: 102 l
Method D: u10 x 1.5e fastener in 12"-12" pattern at 6- ..a.- 228 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intel
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in
FL 17022.01-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVMZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, n will
acquire, a financial interest in any other entity involved in the approval process of the products
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design a outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Coven r themanufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or mplied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
• '
MAX
FL17022.01 - R8
Instructions:
Select the appropriate load table that applies to the /I
structure in question.
Determine the design wind speed for the project a-�` 2 2 3
location.
Use the attachment method indicated for that \2 \
windspeed within each roof
zone-2 2 3 a
2 1 2 — 2 3
NOTE: ASCE 7-16 and FBC 2020 adopt a ]-zone concept.
For the load tables below, the worst case was taken :Z
for each one and reported using the standard zones 'y/ 1 1 2
Zone I includes zones 1 and V a I3 _ ,3II a
Zone 2 includes zones 2e, 2r, and 2n ��a wv � a,eu soar
Zone 3 includes zones 3e and 3r J=;
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A: METHOD B: METHOD C: METHOD D:
#9 AT 16"O.C. #10 AT 16"O.C. #10 AT 8"O.C. #10 AT 6"O.C.
-12"(NOM)� 12"(NOM) NR: NOT RATED, CONSULT DESIGN
—^ a PROFESSIONAL AS NEEDED
Use this load table for structures which meet the following criteria: Use this load table far structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a Oat roof,or gablelhip roof with max slope of 12:12 Have either a Bat roof,or gablethip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15132" plywood FL17022.01: 26 a 5V Crimp on 15132" olvwood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A C D D D
Zone 2: A A A A A A A A C D D Zone 2: A A A A C D D D D D D
Zone 3: A A A A A A B C D D D Zone 3: A A A C : D D D D D D
Use this load table for structures which meet the following criteria: Use this bad table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a Oat roof less than 7',hip roof with Have either a flat roof less than 7",hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15132" plywood FL17022.01: 26 a 5V Crimp on 15132" I ood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A AlZone 1: A A A A A A A 8 C D D
Zone 2: A A A A A A A A A B C Zone 2: A A A A A B D D D D D
Zone 3: A A A A A A A B D D DJ.JZDne 3: A A A B D D D D D D D
0CMEf-1EMETALFABRXCAT0RaCi