HomeMy WebLinkAboutLONGO ROOFING INFO SHEET.pdf(1) S'-, LULL 02 L?N-� IS-T. # Ir.I P I_ c 1.: t L, tz - ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition �2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A, B,D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A,B, D Wood Shingles and A, B,D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 ST, LUCIE Section A(General Information) Master Permit No. Process No. Contractors Name: 0n f License# c C.C. c �A g 91 y Job Address 57 ! % 5q1g1qm "D r. t-64 Ray-co- , EL 3qc�S:, ROOF CATEGORY IJ LOW Slope ❑Mechanical Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles etal Pa hingles Mood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Q Steep Sloped Roof Area(SF) n 0 Total(SF) P22 Q b Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. ED T. P -atking Eq Pharmacies ® ATMs y r�. `" F t�i ST, LUCID Section C(Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1': "oc @ Lap,#Rows @ A dC (If a component is not used,identify as"NA") Zone 1• "oc @ Lap,#Rows @ coo System Manufacturer: PolLheiassZone 2• "oc @ Lap,#Rows ® 1100 Vj Zone 3: "oc @Lap,#Rows-@ cooF Product Approval No.: C Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1'-- Zone 1: Zone 2: Zone 3: Zone 1':.W Zone 1: Zone 2 7-alone 3riLa Illustrate Components Noted and Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping,Etc.. Deck: Indicate:Mean Roof Height, Parapet Height, Height of Base Type: WJ Flashing,Component Material,Material'Thickness,Fastener Gauge Thickness: / g Type,Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Slope: 12'` Anchor/Base Sheet&No.df Ply(s): FT. Anchor/Base Sheet Fastener/Bonding Material: new oAbakrl rnn� MmbC�1� Insulation Base Layer: A Base Insultation Size and Thickness: bJ- Parapet Base Insulation Fastener/Bonding Material: Height VIA Top Insulation Layer: A.//R Top Insulation Size and Thickness: 669 FT. Top Insulation Fastener/Bonding Material: M1 A Mean Base Sheet(s)&No.of Ply(s): l Roof Base Sheet Fastener/Bonding Material: Height Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: R0&Tn'e &+17m eA Top Ply Fastener/Bonding Material: ST, LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: Eximme, fACJAL fabricat2--5 Notice of Acceptance Number: Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): Zone 1':_Zone 2e Zone 2n:0Zone 2r- Zone 3e:- 109 Zone 3r:—tZg • Deck Type: Type Underlayment Roof Slope: -� 12 ' Insulation: Fire Barrier: n1( A Ridge Ventilation? Fastener Type&Spacing: Adhesive Type: ?eel 4 Si a Type Cap Sheet w i Mean Roof Height: 1Z Roof Covering: lHe4piLI&C-A t _v Type&Size Drip 3 X 3 Edge: Sao LUCIE Section E(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values are eater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x� c �_..Mg; _� Product Approval M- (Zone 2e: x� = -Mg: =M� Product Approval Mf ne 2n: x� _ --Mg: =Mra, Product Approval Mf (Zo 2r: x - -Mg: =Me Product Approval Mf (Zone x --'Mg: =M� Product Approval Mf (Zone 3r: x� - .-._�-Mg: =meir Product Approval Mf Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistan (Mr)From Table Below Product Approval Mf-- Mr required Moment Resistance* Mean Roof Height Roof Slope 5' 20' 25' 30' 40' 2:12 34. 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 0.1 31.6 32.8 34.9 6:12 26.4 2 . 29.4 30.5 32.4 7:12 1 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment base ile systems • For Uplift based tile systems use Method 3.Compare the v es for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile at chment method is acceptable. Method 3"Uplift Based Tile Ca ulations Per RAS 12T (Zone 1: x L =x W:= )-W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= )-W: cos r =Frze Product Approval F' (Zone 2n: x L =x W:= )-W: cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= )-W: cos r =Frzr roduct Approval F' (Zone 3e: x L =x W:= )-W: cos r =Fr3e Pr duct Approval F' (Zone 3r: x L =x W:= )-W: cos r =Fr3r Pro t Approval F' Where to Obtain Information Description Symbol Wher o find Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or y an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.