HomeMy WebLinkAboutPolyglass Flat roof SAV-SAP.pdf(1) 2/17/2021 Florida Building Code Online
AwlP 1
BCIS Home Log In Wer Registration Hot Topics submit Surcharge Stats&Facts Publications Contact us 6cl5 S+te Map Lrnis Search
doprQProduct Approval
O
USER:Puhllc User
- Product Approval Menu>Product or AQohcation Search>ggolicauon Lis[>Application OetalI p FL# FL1654-R27 � ■
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ext 242
matpert@polyglass.com
Authorized Signature Maury Alpert
matpert@ polygIass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.corn
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach,FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/07/2022
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL1654 R27 C I 2020 01 COI NIEMINEN.pig
Referenced Standard and Year(of Standard) Standard Year
ASTM D4601 2012
ASTM D4897 2009
ASTM D6162 2015
ASTM D6163 2015
ASTM 06164 2011
ASTM D6222 2011
ASTM D6509 2015
https:lfwww.floridabuilding.org/pr/pr_app_dtiLespx?param=wGEVXQwlDgvgqu2w%2bnFgUPv2pw6pKxAhNlxQbXaKmD3xgHjyOAYxuQ%3d%3d 112
2/17/2021 Funds Building Code Online
ASTM G155 2013
FM 4470 2016
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
Certi0ed By
Sections from me Code
Product Approval Method Method 1 Option D
Date Submitted 10/02/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/12/2020
Date Approved 12/15/2020
Summary of Products
FL# Model,Number or Name Description
1654.1 Polyglass Modified Bitumen Roof SBS and APP modified bitumen roof systems
I Systems
Limits of Use installation Instructions
Approved for use in HVHZ:No
Approved for use outside HVHZ:Yes R22.odf
Impact Resistant:N/A Verified By:Robert Nleminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Thiml Party:Yes
Other: 1.)The design pressure in this application relates Evaluation Reports
to one particular assembly over concrete deck. Refer to the
ER Appendix for other systems and deck types. 2.)Refer to R27.adf
ER,SeQlon 5 for other Limits of Use. 3.)Refer to R167I7 Created by Independent Thlyd Party:Yes 1
for HVHZ pm dictions.
0
I9atad Us::2601 Blair stone Road T,llahawee a 32399 Phone:850.487-182e
The stainsl Fla..aan ogee)amplo,raa.aant zom-zar[ .ar Fnam.::pdyssy3trhmra[::n[aeNelllms ::Remne Rt•tem
V toalswae,Isan ,-ntaatart WW< weaneclywestatwentyoV have
anyge,bor,vimsWnum a WWert[oMtamean M rwt ern 4s¢pVmG
nyll[s Mls enllty.ln9eaa.[Matt the three by IMlsne n Cy tnal[bul mell.Ilyw have any yu[seons.plea4¢ntett 950.ia].U95.•PursYsn[m SeCbn a553]5(I),
FbrMa$bNles.eXe[eve 0.tsMt 1.3013.Ixmeees N[eruN uMer CTaph,a55.F.S.murtpmviae[M Deperimm[wlq an avJ eaartss H NeY Mveaw.lhe emalli
rm
gsNa[a mwy Ee uuO lst alaclal[smmuNutlm wIN Ne Ikemee.nexevtt rneJ aaatesses are puda rtcara.l(yw es n4wlsli m alpplY a peasmal males,please
psNEe qe Department with an small aEERU xhkA ran Ee moos avellsek m Me Wdk.Ta ae[ertnlne I!you ere a fttniee unaet CMphta55.F.5„pease 6(k bSQ.
p,weYa Mprwv.l a:evt,:
® ® Q
Credit Card
Safe
hfpslA .floddabuilding.org/pripr app_dd.aspx?pamm-vGEVXQMDgvgqu2w%2bnF9UPv2pw6pKxAiINlxQbXaK D3xgHjyOAYxuQ%3d%3d 2J2
MEMO etc.
Certl(mre o/Authorization#32455 U
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
aREPORT
Polyglass USA, Inc. Evaluation Report P9290.02.08-11125
1111 West Newport Center Drive FL1654-R27
Deerfield Beach, FL 33442 Date of Issuance:02/11/2008
(954)233-1330 Revision 25:09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7a Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Polyglas5 Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number(FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5,plus a 94-page Appendix.
Prepared by: `^^^s•p.—
•y,..,..
Robert J.M.Nieminen,P.E. ;*'•ay ±f':. meFamn,neFeamana,me.a•aw�an."aa eyxonen
Florida Registration No.59156,Florida DC4 ANE1983 '�wf„?;!,',kt•`` - Nlemlmn,P.E.on as/nonom cols does notzerre asan
0.iik.lp Flened documenl
CERTIFIGTIDN OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will It acquire,a financial interest in any company manufacturing or
distributing products It evaluates.
2. NEMO ETC,LLC Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018,NEMO ETC,LLC
®MEMO I etc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: Polyglass Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the 70 Edition (2020) Florida Building Code through
testing In accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
STANDARDS:2. Section Propel Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2012
1504.6 Accelerated weathering ASTM G155 2013
1504.7 impact resistance FM 4470,Section 4.6 2016
1507.10.2 Material standard ASTM D4601 2012
1507.10.2 Material standard ASTM D4897 2009
1507.11.2 Material standard ASTM D6162 2015
1507.11.2 Material standard ASTM D6163 2015
1S07.11.2 Material standard ASTM D6164 2011
1507.11.2 Material standard ASTM D6222 2011
1507.11.2 Material standard ASTM D6509 2015
3. REFERENCES:
inift Egam Reference Date Entity Egam Reference Date
ERD(TST6049) Physlrah P10490.1008.2 10(30/2C08 FM ITST1e671 FM 44M 3006115 05/02/2001
ERD(TST6049) FM 4470/44)4 P33760.09.09 09/IO2W9 FM(TST1867) FM 4470 3012322 07/29/2002
ERD MT6049) FM N70/404 P13770.09.09 09/10/2W9 FM(TST166)) FM 4470 MU692 OVOS/2003
ERDmna)49) FMN70/4474 1`30540.11.09 R1 11/30/20(9 FM(TST166)) FM"M W14751 08/27/3003
ERD(TST6M9) FM H)0/44)4 P305SOA2.09 12/N/20U3 FM(TST1867) FM"" 30071)0 oUl3/2.
ERDIM6m9) Physiah P33960.12.10 1WO12010 FM(TST186)) FM470 r0uu17 O6/30/EO%
END ma'60191 FMM)0/W4 P33970.03.11 03/1S/20II FM ITST1867) FM"M 3020703 07/30/20X
EAU(1576019) Phy k P3759003.133A 03/06/2013 FM(TST186)) FMMM/4474 301032 01/31/2006
ERD INTIG49) FM 44AV.74 P3969003.13 OARK/2013 FM(15T186)) FM44)0/M4 30233U 03/20/2W6
ERD(2116049) P vy N P3759001133R1 W/26/2013 HV(TnI867) FM.M/4474 30245% 0/23PM
ERD(TST6049) P"Iab P375%,03.133MI 0/01/2013 Ha M1867) FMN70/N74 3023458 0/18/2W6
ERD ITST60R)1 Ph"I.k P37590.07.132 07/01/2013 FM991867) FMN70/H74 3030668 09/12/2007
ERD(TST600) Physlrak P1759003.135 R1 07/01/2013 FM IRtt867) FM 4470/N74 3032172 06/12/2009
ERD(TST60491 Physlob P3759007.131 07/02/2013 FM MT1867) FM 400/4474 SU9631 04/2)/An4
DID m T6049) FM44A/4474 P4n,3008'I3 (X/06/2013 FM MT1867) FM4470/4474 30M29 0?/02/2017
ERn(MblP49) Physicals "59,10.09,23 09/04/M13 NEW(TST6049) CM.11ry npA &1FWID618 M/23/2018
ERD(TS11049) Physials P44370.10.13 10/04/2013 NEMO(TST60391 FM N74 41PLY4UI.ArL 08/21/2018
ERD(TT6D49) Physirak P39520.09.162 03/1112014 NE N)p5T5049) CMiollt, 10/03/20M
ERD(TST60,19) FM4 AVVI74 Scunw.11.14 IV10/2014 Nvoorno6D49) ASTM Dust, 4SnWLmLiLiax 11AW018
ER0(TST6019) PhSslok P454405C.03.IS1 03/3rtsua NEW p5TE049) /STM D6164 4SnWL0]Liva3 11/20018
ERO(T516049) Phliak SC5170.05.15 05/0811ce NEMO(TS75049) FM 4474 44PLY41Ff0L11Y 11/28R018
ERDm TWa9) FM 4474 SCW95.05.15 0119/2015 NEMO(MG049) FM44)4 41-11s.i aots OIAW019
ERD(TSTW49) Physimis SC5170.1115 12/29/2015 NEMO(TSr6949) ASTM M163 4SAY41aA]LOL14A 01/24/2029
ERD(TST6M9) FM rMVU74 A945515 N10112016 NEMO(TSTWa9) ASTM D6162 41nI.I .I.I. Ol/25/2019
mr)(TST6W)) FM 4470/4474 FLYGSC8905.05.16.1 05/17/2015 NEMO(TST6049) FM 4474 4L,KYGIaM.WISA m/01/2019
ERD MT6,a49) FM OM/4474 PUG-SC11905.05.16-2 05/17/2016 NEMO(TST6049) ASTM DOZZ 4SPLY6 U.o.1 t1c 0/20/2029
ERD(TST60a9) FM 4470/4474 PL 1tioi5.O7.I6M 09/23/2016 NEMOnST049) ASTM D5222 4SPLYG v&UU 05140 M/20/2019
Can DST6049) UL1897 FOG SC22025.10.16 10/12/2016 NEMO(TST6049) ASTM M163 4Stt nlID L05]4M UUM/2019
ERD(TST6o49) FM 4470/4474 MYG-SC11475.16 11/17/2016 NEMO(TST60491 ASTM D6154 45n U14XM5]4N QuaL2019
Can M6049) FM 4AV"74 MYGX]3235.01.17 OU17/2m7 NEMOmTW49) G lh, 41.1r0owt9A 07/17/2029
ERD(705049) FM 4M1.741 PLYG5CL3920.0S17 05tUVW17 NEMO(1316049) A5TM D614 45PLY4LL0]LW.I41 oemn019
ERDMT11294) FM 4)0/474 05/30/Wl7 NEMO DSTW491 ASTM 0614 4SMY41B0]SIN.I41 QVoVzo19
ERD(TSTIII9 ) FM 4T0/474 FLYOCmMsarf GS/30/O17 NEMO(MR0191 FM 474 4a'rttt.NliSMVSOIA 08/28/2D20
ERD(TST6019) FM 470/474 PLY6-SC1394SM.17 05/30/2017 PRI(TresIn) Physiab PUS1062-02-01 12/01/20[7
ERDmMiUI9) FM Vlrv474 PLY(I3CIS760.09.17 09/31/2017 pttlMears) Physirak PUSl-061-02-02 01/28/2001
FM CTM86)) FM 470 2MA7.AM 08/04/1934 FRI ITST5876) Phys b PUMA 02-02 02/27/2009
FMRST186)) FM 4470 003A3.AM W4 1/1997 FRI ITST58791 Phy—ts PUSA(1620242 12/04/2018
FM ITS7186)) FM 4470 2WAUAM 12/23/1598 PRI(MT58)8) TA5114 PUSA 188-0201 02/08/2017
NEMO ETC,LLC EoalU tIon Report"290.02.08-1125
Cem7ianc~orboddo#32455 7T"EDITION(2020)Pat NON HVHZ EVALUATION FL1654-R27
Polyglass ModlRed Bitumen Roof Systems R.isi0n 25:09/30/2020
Page 2 of 5
ONEMOjetc.
Entity Exam Reference Date Entity EXdm Reference Date
FM(TST186T) FM 4O70 2D5A9.,1M o6/22/1999 PRI IT575a]8) TA51l4 PUMA 88-@02 03118/101]
FM ITSr186]) FM 4470 3006M6 O1/OG/2WD PRI(TST58]8) TAS14 PUSA3W-0203 02/08/2.17
FM DStt86]) FM<00 3W1331 O]/25/IWO PRI(TST58]B) iAS 114 PU543@-02L1 O5/1]/301)
FM p5T1861) FM<00 30013M 02/15/2000 PRI(T5158]8) TM 114 PUM 202-02-02 05/1]/20ll
FM(T52186]) FM N70 30.V85] DV1ZjZ= MD(CER1592) HVHZ Venous NOAs V.d.n
FM Ds2186)) FM ii70 3004131 01/12/2000 M D(CER1592) Prop.I.,Rw 1 11123 I01=010
UL(0UA9625) coalhy Conmi Xrvvoco.fi_ 03/13/2018
DESCRIPTION:4. PRODUCT
This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass
USA,Inc.published Installation instructions and the Limitations/Conditions of Use herein.
TABLE 1:ROLL-GOODS FOR MODIFIED BITUMEN ROOF SYSTEM
Type Product Materiel Standard Plant(s)
Reference Type Grade
Polyglass G2 Base ASTM D4601 II N/A AL
Polyflex SA Base ASTM D4601 II N/A FL
Base Sheets Elastobase SA ASTM D4601 II N/A PA
Elastovent ASTM D4897 N/A N/A PA
Polyglass Base ASTM D6509 N/A N/A FL
APP,Smaath-Surface Pol bond ASTM D6222 I S FL
Membranes Polyflex ASTM D6222 I S FL
Polykool ASTM D6222 1 5 FL
PolybondG ASTM D6222 I G FL
PolyflexG ASTM D6222 1 G FL
Polyflex G FR ASTM D6222 I G FL
APP,Granule-Surface PDlyfreskoG ASTM D6222 1 G NV
Membranes Polyfresko G FR ASTM D6222 1 G NV
Polynex SA P ASTM D6222 I G FL,TI(
PDlynex SA P FR ASTM D6222 I G TX
Polyfresko G SA ASTM D6222 I G NV
Polyfresko G SA FR ASTM D6222 I G NV
Elastoshield HT ASTM D6162 III S FL
Elastobase ASTM D6163 I S FL
Elastoflex V ASTM D6163 I S FL
Elastoflex SA ASTM D6163 I S FL,PA,TX
Elastoflex SA V FR ASTM D6163 I S FL PA,TX
SBS,Smooth-Surface Elastoflex SA V Plus ASTM D6163 I S FL,TX
Membranes Elastoflex SA V Plus FR ASTM D6163 I S FL,TX
Elastobase P ASTM D6164 I S FLTX
Elastoflex SA Base HD ASTM D6164 I 5 PATX
Elastoflex 56 ASTM D6164 1 5 FL
Elastoflex 56 HP ASTM D6164 II 5 NV
Pol reflect ASTM D6164 1 5 FL
Elastoshield AT G ASTM D6162 III G FL
Elastoshield AT G FR ASTM D6162 III G FL
Elastoflex V G ASTM 06163 1 G FL.PA
Elastoflex V G FR ASTM D6163 1 G FL,PA
SBS,Granule Surface Elastoflex SISG ASTM D61M I G FL PA
Membranes Elastoflex S6 G FR ASTM D61M I G FL
Elastoshield TSG ASTM D61M I G FL TX
Elastoshield TS G FR ASTM D61M I G FL TX
Elastoflex SAP ASTM D6164 I G FL TX
Elastoflex SA P FR ASTM D6164 I G FL TX
NEMO ETC,LLC Evaluation RaImrt P9290.02.08-R25
Consta a o)AUMonmton N32855 )o'EDITION(2020)FBC NO&HVHZ EVALUATION FU654-RI7
Polyglass Modlfled Bitumen Roof Systems Revision 25:09/30/ZOZO
Page 3 of 5
ONEMIDIetc.
K. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC,LLC nor Robert Niernmen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone Jurisdictions(i.e.,Broward and Miami-Dade
Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning
the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements
and limitations regarding edge securement for law-slope roofs.
5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations.
5.6.1 For mechanically attached components over existing roof decks,fasteners shall be tested in the existing deck for
withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing shall be in accordance with ANSI/SPRI FR-1 or Testing Application Standard
TAS 105.
5.6.2 For bonded insulation or membrane over existing substrates in a re-roof ftearoff)orrecover installation,the existing
deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface
conditions exist that bring system performance into question,field uplift testing in accordance with ANSI/SPRI IA-
1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on
mock-ups of the proposed new roof assembly.
5.6.3 For banded insulation or membrane over existing substrates in a recover installation,the existing roof system shall
be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having
Jurisdiction,as documented through field uplift testing in accordance with ASTM E907, FM Lass Prevention Data
Sheet 1-52 or Testing Application Standard TAS 224.
5.7 Refer to Appendix l for system attachment requirements for wind load resistance.
5.7.1 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2)the 2 to 1 margin of safety per FBC 1504.9 has already been
applied).Refer to FBC 1609 for determination of design wind loads.
5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with
FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are AN51/SPRI WD3, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.
Assemblies marked with an asterisk-carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29)February 2020)for Zone 2/3 enhancements.
5.7.3 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16. No rational analysis is
permitted for these systems.
5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are
produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report.
NEMO ETC,LLC Evaluation Report P9298.02.08-R25
CeK7 to P7AulhN von#32455 7'EDMON I2020I FBC NONAVH2 EVALUATION FL1654-R27
Poly[la4s Modified Bitumen Roof Systems Revision 25:09/30/2020
Pap 4 of S
ONEIVIOletc.
Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published
installation instructions,subject to the Limitations/Conditions of Use noted herein.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named CA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625:(414(248-6409,karen.buchmann@ul.com
THE 94-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report P9290.02.08-1125
Oo-aAco..fAutnomaaaa 11455 7-EDITION(2020)Fee Ni EVALUATION F11654-1127
Polyglass Modified Bitumen Roof Systems Revision 25:09/30/2020
Page 5 of 5