Loading...
HomeMy WebLinkAboutSurvey ReportSURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with on embossed Surveyor's Seal 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 4.6.2010. 4 This Survey was prepared using the Plat of Record only. No other documents were provided and no search of the public records was performed by this office. 5 The Survey shown hereon and prepared this April 19, 2010 was prepared in accordance with the requirement for field accuracy as set forth by the Minimum Technical Standards (61 G 17-6FAC). 6 By acceptance of this survey all parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Unless other wise noted all bearing and distances are in accordance with the record plat and have been verified by field measurements. See map for bearing base. 8 Parcel/Lot line locations have been based on found survey control along the center line of NE Lobster Road. 9 LEFT BLANK. 10 The Legal Description shown hereon was provided by the client and/or his/her representatives. 11 No ownership of fence lines has been determined as part of this Survey. 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC), point of reverse curvatures (PRC) or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. 14 Elevations shown are in accordance with the North American Vertical Datum a AN CIE — Covered Entry CAC — Concrete Pad with Air Conditioning CBS — Concrete Block Structure CARP — Corrugated Metal Pi e CPE — Concrete Pad with Pool Equipment CN — Cable Tv Box Cv — Water Cate valve HYD — Fire Hydrant OIL — Overhead Utility Line PP — Power Pole TCB — Telephone Communications Box St. — Street Light SSMH — Sanitary Bax Sewer Manhole UB - Utaity WM —hater Meter FCM — Found 4'x4 Concrete Monument PIP — Found }' Iron Pipe FiPC — Found Iron Pipe with Cap 284907' FiR —Found 5 Iron Rod FIRC — Found 15 iron Rod with Cap SIRC — Set 15 Iron Rod with Cap 'LB17357' FIPC — Found 112' iron Pipe with Cap FM — Found Mai, Nail TT — Found Mag Nail with Tin Tab D — Found Mog Nail with Disk FN — Found Nail FNTT — Found Nail with Tin Tab FPK — Found PK Nail FPKD — Found PK Nail with Disk FRRS — Found Rail Road Spike ,7CO — in Pavement Cut Out Flood zone Data derived by scaling methods of the official FEMA Maps and limited to the accuracy of such maps. Flood Zone: x Community : 120285 Panel : 0278 Suffix: if Date: 2.19.2020 I.N at PC N y o � m CN v `4- m rn 30.00' @--_________ 'rn 3a00` W 12.0' wv_ WM 3 a CL � p O a PREPARED FOR: Douglas J. Leighton, Jr. Angel Oak Mortgage Solutions LLC, Its sucesso and/or assigns as their interest may appear First American Title Insurance Company, By: Regina C. Karner, PSM Florida Registration # 4363 Karner Surveying, Inc. LB#7357 Prepared For: Douglas J. Leighton, Jr. St. Lucie CounLy Florid 2 i 11 LEGAL DESCRIPTION Lot 9, Block 73, RIVER thereof, as recorded in Lucie County, Florida. PARK — UNIT 9 PART "A'; according to the Pic Plat Book 14, Pages 31, Public Records of St. i 50008'30 "E 110.00' Fence corner Lot 10 Block 73 1 ®n (iDe _ 6'Drainage & utility Easement Fenae Line.. PP �TCB No ID 6'Droinage l & Utility Easement o I I l I �. ___ ...� _ 1 _�� �...a_...._ _.- .m_...�. _., m i__ �3W ... w....�. do 2 - 2 0 -_ 20.2' 6.9` Shed 2 5 LE,W flf g 'flb c:k CAR PORT 06 uri 00 Lill C" Conc. Drive EL. 15.18 Conc. w In o �n i 3.9 1 1.9, "ar- . O w C11 i �p o � lo o N N a gi LL. in 2 ` 11.93' �'n I \ CO v _ r< o Q, ti ) ° j Lot 9 Block 73=co co I 23.8' c� BhWdinm S, tb kt ll Rim at FIP 6'Drainage & Utility Easement I El 14.02 No ID 1 1 RMH 1. 10' l KARNER SURVEYING, INC. Residential & Commercial Surveying Services 2740 SW Martin Downs Blvd 333 Palm City, Florida 349W 6'Drainage '& Tbtility Easement N00018'30 "W 110.00' " - i _7 T Lot BBlock 73_____ NOTE: (This property is in a RS-4 Zoning District. In accordance witd the L 0d Development Code„ Chapter Vll Development Code Section 7.04.04 the following property development standards should be adhered to: Front Building Setback = 25', Side Building Setback = 7.5', Rear Building Setback = 15' Total maximum coverage = 30% Digitally Reg I n signedby rRegina Kan a, Date: V 2A27 1 O,�2$ Kamer o:10�2 NOS Mid Unr .s S-rd With M E sed Su y-s Seal sheet Titre, a date Boundary Survey s all e, ha No,� 20 4 [/1O �i$ brown Cl fl#9. By, P ,`!`GYf _1 f '�,.. )� 1001 1003-16 Proj: SLC_RiverPork1RivParkU9A-73-9