Loading...
HomeMy WebLinkAbout2422 oak dr faSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Ron Raymond AGENT: MICHAEL STUHR (ASHTON SEPTIC TANKS, INC.) PROPERTY ADDRESS: 2422 Oak Dr Fort Pierce, FL 34949 APPLICATION #:A+P1605278 PERMIT #:56-SF-2210651 DOCUMENT #:F11718223 DATE PAID' 12/07/2020 FEE PAID:660.00 RECEIPT #:56-PID-4822898 LOT: 6 & 7 SUBDIVISION: BLOCK: 3 Fort Pierce Shores ID#: 1436-601-0055-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RUDE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1090.00 [21 300.00 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 91 FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER PolylokPL-68 [ ] (311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2. 70-156-03SC3 [ ] [321 POTABLE WATER 30 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 5.5 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 9 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 509.4 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 6.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 8.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] (201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] [471 CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [221 FILL AMOUNT [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [231 FILL TEXTURE [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 09/10/2021 DISAPPROVED Environmental Specialist III B n J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]:�— t. Lucie CHD DATE: 10/22/2021 n nm pecia ist I Matthew S Vaja i Ada Department of H (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP160 5278 EID2210651 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:Ai`16052 8 PERMIT #:56-SF-2210651 DOCUMENT # : FI 1718223 DATE PAID :12/07/2020 FEE PAID:660.00 RECEIPT # :56-PI D-4822898 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, DT, liberty 1/3 hp pump, and 3x7+3x8 long BED DF installed. No violations, system ok to cover, contractor notified by phone. Needs final inspection for mound system, alarm check, and final site grading. Final inspection completed. Mound system, final site grading, and alarm checked. Final inspection approved. Emailed copy to building department and contractor. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1605278 EID2210651