Loading...
HomeMy WebLinkAboutPermit #2105-0411 compaction signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net October 25, 2021 KSM JOB # :218759-1d/JM/jam CONTRACTOR:AEM & Associates 3 Ridgewood Circle Jupiter, FL 33469 JOB LOCATION:13506 NW Cocoplum Court Palm City, Florida PERMIT #:2105-0411 Respectfully, PE # 68366 10/25/21 Certified Women Owned Business - WBE To Whom it may concern, Enclosed, please find the nuclear density test results performed on the compacted foundation fill at the above referenced project. Should you have any questions, please feel free to contact our office. Julie E. Keller, P.E. President Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Email: andre@aemandassociates.com Proudly Serving Florida since 1990 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:218759-1d/JM/jam NUC #215 Nuc Model:MC-1DR-P Nuc Serial #:MD80404215 13506 NW Cocoplum Court Palm City, Florida Compacted Foundation Fill DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 S.W.0" - 12"14D 108.8 112.0 97.1% 2 Center "15D 109.8 "98.0% 3 N.E."14D 109.1 "97.4% 4 S.E."15D 109.5 "97.8% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement 10/25/2021 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting ITEM TESTED: Soil Description: TEST LOCATION OF SAMPLE Proudly Serving Florida since 1990 Certified Women Owned Business - WBE 11.2% PE # 68366 for Staked Foundation 112.0 JOB LOCATION: Brown Sand with Traces of CONTRACTOR:AEM & Associates SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 DATE TESTED:October 25, 2021 Clay and Shell Fragments In Place Moisture: PERMIT #:2105-0411 Email: andre@aemandassociates.com 12.0% Julie E. Keller, P.E. President Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:October 25, 2021 KSM JOB # :218759-1d/JM/jam PERMIT #:2105-0411 CONTRACTOR:AEM & Associates JOB LOCATION:13506 NW Cocoplum Court Palm City, Florida Soil Description: Brown Sand with Traces of Clay and Shell Fragments Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 112.0 Julie E. Keller, P.E. President PE # 68366 10/25/2021 Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting SOIL COMPACTION REPORT ASTM D 1557 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Certified Women Owned Business - WBE Proudly Serving Florida since 1990 107.0 108.0 109.0 110.0 111.0 112.0 113.0 7 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight