Loading...
HomeMy WebLinkAboutRidge Vent (56)1/14/21, 10:40 AMFlorida Building Code Online Page 1 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO%2bC3zFtrydq9fPhgLACiVmFHfXqoD3ASJQ%3d%3d BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL10758-R8 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10758_R8_COI_OCR14003.4 2020 FBC Eval Vents final_.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards 1/14/21, 10:40 AMFlorida Building Code Online Page 2 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO%2bC3zFtrydq9fPhgLACiVmFHfXqoD3ASJQ%3d%3d Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 08/10/2020 Date Validated 12/16/2020 Date Pending FBC Approval 09/18/2020 Date Approved 12/17/2020 Summary of Products FL #Model, Number or Name Description 10758.1 VentSure 4-Foot Strip Heat and Moisture Ridge Vents Copolymer plastic low profile attic ridge vents for installation in shingle roof systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report Installation Instructions FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Roof Vent With Exterior Louver Galvanized metal roof vent Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report. Installation Instructions FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report. Installation Instructions FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 1/14/21, 10:40 AMFlorida Building Code Online Page 3 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO%2bC3zFtrydq9fPhgLACiVmFHfXqoD3ASJQ%3d%3d a CREEK Technical Services, LLC OCR14003.4 FL10758-R8 Page 1 of 5 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance c hanges throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 www.owenscorning.com Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year Architectural Testing, Inc (TST1558) 01-38660.04 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) 01-38660.05 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) C1774.01-109-18 TAS 100(A) ASTM D 635 ASTM D 1929 ASTM D 2843 1995 2014 2016 2016 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 635 ASTM D 1929 ASTM D 2843 2014 2016 2016 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) OCF-111-02-01 ASTM D 635 ASTM D 1929 ASTM D 2843 2014 2016 2016 PRI Construction Materials Technologies (TST5878) OCF-112-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OCF-223-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OHI-007-02-01 TAS 100(A) 1995 CREEK Technical Services, LLC OCR14003.4 FL10758-R8 Page 2 of 5 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING VentSure® Roof Ventilation PRODUCT DESCRIPTION AND APPLICATION VentSure® 4-Foot Strip Heat and Moisture Ridge Vents: 1-1/4´ x 14-7/8´ x 48´ low-profile attic ridge vent consisting of a two-layer nylon- polyester composite. Available with or without a polyester fabric moisture barrier for installation in shingle roof systems. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 to maximum 16/12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6 -inches from the rake edges. Apply a ¼-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles , taking care to not completely cover the weep slots in the vent . Center the vent over the opening and fasten to the deck using the 11 ga. 2½-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked ³shingle nail line´ with two (2) minimum 11 ga. 2½-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer¶s installation instructions. Allowable Roof Coverings: Asphalt shingles 48´ 14-7/8´ CREEK Technical Services, LLC OCR14003.4 FL10758-R8 Page 3 of 5 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING VentSure® Roof Ventilation VentSure® Low Profile Slant Back Roof Vent with Exterior Louver: 18´ x 24´ x 2-3/16´ (32´ x 23´ flange base) static off-ridge vent composed of ASTM A653 galvanized steel (available with painted finish). Material shall conform with FBC Section 1507.4.3. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring Ǫ-inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in ¼-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring Ǫ-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles CREEK Technical Services, LLC OCR14003.4 FL10758-R8 Page 4 of 5 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING VentSure® Roof Ventilation VentSure® Rigid Roll Ridge Vent: 5/8´ x 11-1/4´ x 20¶ attic ridge vent composed of high density polypropylene with a spun-bond polypropylene fabric. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring Ǫ-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked ³shingle nail line´ with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed b\ the shingle manufacturer¶s installation instructions, ensuring Ǫ-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATIONS 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer¶s published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. CREEK Technical Services, LLC OCR14003.4 FL10758-R8 Page 5 of 5 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING VentSure® Roof Ventilation COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT 2020.12.15 13:59:34 -05'00'