Loading...
HomeMy WebLinkAboutAPPROVED, Electrical Plans - Revised(1)HYDRO PUMPS, INC. 6512 NW 13TH COURT PLANTATION, FL (954) 583-3303 INDUSTRIAL CONTROL PANEL ENCLOSURE TYPE: 4X 3 014 S E. UL LABEL NUMBER: B-52896099 DRAWING NUMBER: AP2020R2 SUPPLY VOLTAGE: 240V/1PH/60HZ TOTAL FULL LOAD AMPS: 40 LARGEST MOTOR HP: 2 SHORT CIRCUIT CURRENT: 2kA rms symmetrical @ 240V maximum --� N G III MAIN DISCONNECT TO BE PROVIDED BY OTHERS L1 L2 - BSI N B1 VM B2 BC BR "BE 30 GR 60 AMP I I 3T3 333 23OV, 1 PHASE, 60 HZ L1 - 115V TO GROUND O SC OgRC SC TO WIRE COLOR CODE SRtRC SR CONTROL(#,CLR0 - BLACK 1 - BROWN SR O 2 - RED 3 - ORANGE 4 - YELLOW T1 T2 T3 T1 T2 T3 5- GREEN R W g R W B 5 - BLUE 7 - PURPLE )FLA M2 8 - GRAY 9 - WHITE 12.12.5 FLA 2 2 HP NOTE: ALL CONDUITS TO ENTER FROM BOTTOM ONLY USE COPPER CONDUCTORS RATED 60degC IF RATED LESS THAN 100 AMPS; 75degC IF RATED 100 AMPS OR MORE TERMINAL TIGHTENING TORQUE REQUIREMENTS FOR FIELD WIRING TERMINALS ARE AS FOLLOWS: 35LB—IN FOR #18— #10 AWG; 40LB—IN FOR #8 AWG; 45LB—IN FOR #6—#4 AWG; AND 50LB—IN FOR #3 AWG AND LARGER TERMINAL TIGHTENING TORQUE REQUIREMENTS FOR #18 AWG PUMP CONTROL CABLES AND FLOAT CABLES ARE 20LB—IN CAUTION — MULTIPLE POWER SOURCES ARE PROVIDED WITHIN THIS CONTROL PANEL. MAIN AND EMERGENCY CIRCUIT BREAKERS ARE MECHANICALLY INTERLOCKED TO PREVENT SIMULTANEOUS OPERATION. DISCONNECT ALL POWER SOURCES BEFORE SERVICING. WARNING — USE OF THE FOLLOWING COMPONENTS IS DEPENDENT UPON THE ADDITIONAL PROTECTION AFFORDED BY THE GROUND FAULT CIRCUIT INTERRUPTER AND THE OVERCURRENT PROTECTIVE DEVICE PROVIDED. DO NOT REMOVE OR DEFEAT THESE PROTECTIVE COMPONENTS. THE GROUND FAULT CIRCUIT INTERRUPTER SHOULD BE CHECKED PERIODICALLY FOR PROPER OPERATION. COMPONFNT IDENTIFICATION DUPLEX RECEPTACLE PASS & SEYMOUR 1595TRWRW 17 HYDRO PUMPS, INC. MJC/CDL DRIVING SCHOOL DATE: 7/30/21 REV: 2 6512 NW 13TH CT. DUPLEX LIFT STATION BY: JR CH: PLANTATION, FL 4XSS/M-2021-ACD1 EGLM02RSV DWG: AP2020 SHT: 1 /3 (954) 583-3303 HYDRO PUMPS, INC. MJC/CDL DRIVING SCHOOL DATE: 7/30/21 REV: 2 6512 NW 13TH CT. DUPLEX LIFT STATION BY: JR CH: PLANTATION, FL 4XSS/M-2021-ACD1 EGLM02RSV DWG: AP2020 SHT: 2/3 (954) 583-3303 MINNI'l., 0 (9 EyT-M�1 EfM2 0 PI-1 PI-2 a a PI-3 PI-4 C::� TEST DEAD FRONT ALARM LIGHT m 0 (9 EyT-M�1 EfM2 0 PI-1 PI-2 a a PI-3 PI-4 C::� TEST DEAD FRONT ALARM LIGHT m IN i rruvv�o � i rruvv�o � a. N RC NRC a H BUZZER SRHSR im ® SILENCE BACKPANEL * LIGHTNING ARRESTOR MOUNTED TO BREAKER FRAME BILL OF MATERIALS ALARM LIGHT ME-, VM ALT R1 SF1 SF2 BUZZER SILENCE BM/BE MAIN/EMERG BREAKERS SQUARE D QOU260 INTERLOCK SQUARE D QOU2DTILA B1/B2 PUMP BREAKERS SQUARE D QOU230 BC CONTROL BREAKER SQUARE D QOU115 BR RECEPTACLE BREAKER SQUARE D QOU115 REC DUPLEX GFI RECEPTACLE PASS & SEYMOUR 1595TRWRW LA LIGHTNING ARRESTOR SQUARE D SDSA1175 VM PHASE MONITOR DIVERSIFIED UOA24OAKA GR GENERATOR RECEPTACLE APPLETON ADR6034RS S1/S2 PUMP STARTERS TELEMECANIQUE LC1D18G7 01-1/2 THERMAL OVERLOAD RELAY TELEMECANIQUE LRD21 CAP KITS CAPACITOR KITS MYERS 604450555 AL ALARM LIGHT 120V INGRAM LRX-25 BUZZER ALARM BUZZER INGRAM PB120AMB-X SIL SILENCE CONTROL CONCEPTS PBO TEST ALARM TEST CARLING 6FA54-73 R1 DPDT RELAY, 120V IDEC RR2PUC120VAC ALT ALTERNATOR DIVERSIFIED ARB 120ABA SW1/2 HAND -OFF -AUTO SWITCH CONTROL CONCEPTS SS03 ETM 1 /2 ELAPSED TIME METER REDINGTON 71 1-0160 PI-1/2 PILOT LIGHT CONTROL CONCEPTS FVLU120PLLGN SF1/2 OIL SEAL FAIL RELAYS SYRELEC PNR110A PI-3/4 OIL SEAL FAIL LIGHTS SELECTA SL53215-6-BG ENC PANEL ENCLOSURE HAMMOND HW242412SSHK HYDRO PUMPS, INC. MJC/CDL DRIVING SCHOOL DATE: 7/30/21 REV: 2 6512 NW 13TH CT. DUPLEX LIFT STATION BY: JR CH: PLANTATION, FL 4XSS/M-2021-ACD1 EGLM02RSV DWG: AP2020 SHT: 3/3 (954) 583-3303 �I C Nr� VAMP P1240VP ONFUSI SERVICI DISCONNE — SWITCh I ��i�" sr.+.zoz,.�oo,Eo..roza o. zAzozo sly ao � � � I xswxo:,+.co,eouw� v I o ...mzo exr. m L3oA, n PUMP " §—R L2 —� ENGINEERS 0 SURVEYORS VD FUL III ENVIRONMENTAL PHASE a 10250 VILLAGE PARKWAY MONITOR SUITE 201 PORT ST. LUCIE, FL 34967 LIGHTNING ,rouaa S f vT 772A624M55 LI ESTOR I e,wrw.ee n,.,om TO SURGE E O s O S wv*aa \ E <Ennrl:+re ar nurxovennaxe s V4RE ca.CRcoo s rzc .aP Ec[Rtrticar[orwmoawnw es� lr,cutl ac ,,e uw ARRESTOR O*oR S1MrEa _�—� { mDRET R ]-L-N1 TV To CONTROLS 2'CONDUIT 2'CONWR V .w.�N.,.. 1Mo a �vu�Nr°v°x�i;°' zassx,.oz,<co,Ecwozasv nPzozo sxr. t .. Q 0 DAVID L. 6AGGETT, —(DATE) .1176 F FL x9_ 19-473 12 OF 14 IGH WATER ALARM LIGHT EMERGENCY INFORMATION PLAQUE ENGRAVED ON 3" GALVANIZED PIPE CAP 2-PLY PLASTIC LAMINATE TO INCLUDE: 1) NAME AND PHONE NUMBER OF PERSON TO CONTACT IN CASE DISCONNECT SWITCH OF EMERGENCY AND 2) NAME AND PHONE NUMBER OF COMPANY TO CONTACT FOR PUMPOUT IN CASE OF OVERFLOW GENERATOR CONNECTION ALARM BUZZER 3" CONCRETE -FILLED GALVANIZED PIPE POST i� T ALARM SILENCE PUSHBUTTON 1-5/8" SQUARE METAL FRAMING CHANNELS PUMNTROL ,,,,,,�, CONDUIT TO PUMP CONTROL CONDUIT FROM BUILDING S CONDUIT SEAL (TYPICAL OF THREE) BOTTOM OF ONDUIT TO WET WELL (TYPICAL OF THREE) CONTROLPANEL TO BE LOCATED AT OR ABOVE THE 100-YEAR _ FLOOD ELEVATION ONCRETE INCASEMENT N ,t--/-5/8" X 8' COPPER GROUND ROD ELECTRICAL CONTROL PANEL DETAIL PROVIDE PHASE MONITOR FOR THREE PHASE POWER SUPPLY PROVIDE VOLTAGE MONITOR FOR SINGLE PHASE POWER SUPPLY POWER SOURCE GROUND TO 60 TWO-20' 2P/2, RODS NOW SEF DISCC SW JGRAVED ON 1) NAME AND \CT IN CASE )NE NUMBER BUT IN CASE OF TREE) POWER SOURCE GROUND TO 60 AMP 2a, 2PI240VAC RODS NON -FUSED SERVICE DISCONNECT SWITCH L 60 AMP GENERATOR RECEPTACLE NEMA 4X 304SS CONTROL PANEL WIDRIPSHIELD AND FULL GASKET 60 AMP, 2P MAIN 60 AMP, 2P EM (MAIN & EMER BREAKERS MECHANICALLY INTERLOCKED) 2" CONDUIT 30A, 2P PUMP BRKR 30A, 2P PUMP BRKR 15A, 1 P BRKR 15A, 1 P BRKR PHASE MONITOR LIGHTNING ARRESTOR SURGE ARRESTOR MOTOR STARTER MOTOR STARTER J CONV MOTOR REC THERMA UNITS TO CONTROLS 2" CONDUIT 2" CONDUIT I