Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 11 PALO ALTO(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUC[E COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wali Type�1688.7 sqft,) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - [nt Insul, Exterior R=4.1 1448.70 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 a NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1750.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft2 6. Conditioned floor area above grade (ft2) 1720 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(155.4 sqft.) Description Afea 12. Ducts R ft2 a. U-Factor: Sgl, U=1.04 115.42 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 155 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtumr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth! 3.316 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1720.0 sqft.) insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.090 Total Proposed Modified Loads: 52.81 PASS Baseline Loads: 52.95 I hereby certify that the plans and specifications covered by Review of the plans and'�ilr>� Syq this calculation are in compliance with the Florida Energy specifications covered by this _ p Codecalculation indicates compliance with the Florida Energy Code. +< New,- PREPARED BY: Before construction is completed DATE: 1 -1 3-20 this building will be inspected for !i compliance with Section 553.908 „ IF I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. W,� DAT ERI9G NT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 111312021316 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 90 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft- _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 fP 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' — 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft` — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft- _ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0 98 fF 0 1 0 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 __ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Bar Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light N 0.6 No 0.7 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 11 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N=>E Exterior Concrete Block - Int InsuBEDR00M 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 2 S=>W Exterior Concrete Block- Int InsuSEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.4 0 3 W=>N Exterior Concrete Block - Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 S=>W Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0.4 0 5 N=>E Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 N=>E Exterior Concrete Block - Int InsBEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 7 NE=>SE Exterior Concrete Block - Int InsBEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.4 0 8 E=>S Exterior Concrete Block - Int Ins8EDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 9 SE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.4 0 10 S=>W Exterior Concrete Block- Int InSENEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 11 NE=>SE Exterior Concrete Block - Int Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.4 0 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPI IT RI IMMARV CWMI-k-I ICT 01=0nOT WALLS Adjacent Cavity Width Space - Height Sheathing Framing Solar Below o 12 E=>S Exterior Concrete Block - Int Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 13 S=>W Exterior Concrete Block- Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 14 N=>E Exterior Concrete Block- Int lnsddREAT/DINT 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 15 W=>N Exterior Concrete Block- Int InstGREAT/DINI 4.1 20 0 8 0 160.0 ft- 0 0 0.4 0 16 N=>E Exterior Concrete Block - Int Ins&EDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 17 N=>E Garage Frame - Wood BEDROOM 3 11 30 8 240.0 ft2 0.23 0.4 0 DOORS # Orm Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>S Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>N 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 S=>W 4 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft 5 in None None 3 E=>S 8 Metal Low-E Single Yes 1.04 0.29 N 23.2 ft2 1 ft 0 in 1 ft 5 in None None 4 N=>E 14 Metal Low-E Single Yes 1.04 0.29 N 36.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W=>N 15 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft2 10 ft 0 in 1 ft 5 in None None 6 N=>E 16 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft2 300 ft2 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.07 165.35 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Can # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — supply— V -- Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 155 ft' Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [) Jan [ ] Feb Heating Jan Feb Venting [ j Mar Mar r A r [X] May [) Jun [XJ Jul Jun Jul [XJ Aug Aug [XJ Sep Sep (t Oct Oct Nov NovOct (� Dec DO Dec tLX11 ltXl] Jan Feb LLxX�I Mar Pr ll )1 May [ 1 Jun Jul E 11 Aug Sep [[ )) [[z]1 Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 - 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 66 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defaull lbs/sq.ft. 0 ft' Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Defautt(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(81bs/sq.ft. ft' 8 0.3 KITCHEN Default(81bs/sq.ft. ft' ft 0.3 BATH Default(81bs/sq.ft. fN ft 0.3 BEDROOM 2 Default(8 lbs/sq.fL ft' it 0.3 ENTRY Default(8 lbs/sq.ft. ft' It 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' ft 0.3 GREAT/DINING Default(8 libs/.ft. ft. ft 0.3 BEDROOM 3 1/13/2021 3:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce x � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements q The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nininn an wrinn Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, Inspection of log walls shall be In accordance with the provisions of ICC-400. 1/13/2021 3:17 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1448.70 ft= 3. Number of units, if multiple family 1 b. Frame- Wood, Adjacent R=11.0 240.00 flz c N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft- 6. Conditioned floor area (f -) 1720 b. Knee Wall (Vented) R=19.0 30.00 IF 7. Windows*` Description Area c. N/A R= ft2 a. U-Factor. Sgl, U=1.04 115.42 fF 12- Ducts, location & insulation level R ft2 SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 155 b. U-Factor Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor. WA - fN a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. N/A ft2 SHGC: 14. Heating systems kBhilhr Efficiency Area Weighted Average Overhang Depth: 3.316 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): WA ft2 a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 9. Floor Types Insulation Area b. Conservation features None a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft- b. WA R= ft' Credits (Performance method) None c. N/A R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featured _'' Builder Signature: Date: Address of New Home: ��Q� �. City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 3:16 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project Summary Dat: - - wrightsoft ry Br Entire House QUICK CALCS, INC. 317 ST. LUCIE LN, Fr. PIERCE, FL 34946 PWne: 772466-6799 Fax 77246"796 Email: QUICKCALCS@AOL.COM Project• • For. WYNNE DEVOLPMENT THE ROYALE, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 19529 Btuh Structure 16243 Btuh Ducts 5998 Btuh Duds 9055 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfin) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 25527 Btuh Use manufacturers data n Rate/swingg multipplier Equipmentsensibleload 0.95 Infiltration 24033 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2135 Btuh Ducts 2467 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(iF) 1608 160% Equipment latent load 4603 Btuh Volume(ft') 15336 15336 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 28635 Btuh EquivAVF (cfm) 97 51 Rea. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536A'030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latentcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 clim Airflowfactor 0.045 cfin/Btuh Airflow factor 0.046 cm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. C -Pk- wright�50ft- 2021-Jan1308:1422 �y RigltSuteftrivem1201919.021 RSU08101 Page 1 HWr4 ...uner6wngWS ftWAQWYNNEDEV-1HEROYP.LE.np Caic=MI8 Frort Docrfao=_s: N +� wrightsofr RighW@ Worksheet Job: Entire House By QUICK CALCS, INC. By 3178T. LUCIE UN., F.. PIERCE, FL 34946 Prone:72466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name Entire House BEDRCOM 2 Eaposedvidl 1762 ft 32.0 ft 3 Room height 9.4 ft d 9.4 ft hea*wl 4 5 Room dimensions Room area 1631.5 ft 14.0 x 18D ft 252.0 iP Ty Construction U-value Or HTM Area OF) Load Area (ft� Load number (Bbh46--°F) (BWh4P) or perimeter (ft) (Btuh) or perimeter (ft) (Bbh) Heat Cool Gros N/PS Heat Cool Gross N/P/S Heat Cool 6 Vj/ 13A-4= 0.143 ne 4.00 2S5 517 458 1835 1166 0 0 0 0 1Aciom 1270 ne 35.56 70.43 38 0 1344 2662 0 0 0 0 L�(G 11DO 0.390 ne 10.92 11.31 21 21 229 238 0 0 0 0 Vr/ L—G 13A 0.143 se 4.00 2.55 150 130 522 332 0 0 0 0 11 1Ac1om 1270 se 3556 70.95 20 0 711 1419 0 0 0 0 w 13A-0as 0.143 s 4.00 2.55 40 40 160 102 0 0 0 0 w M4c s 0.143 m 4.00 2.55 395 395 1581 1005 169 169 677 431 s 0.143 nw 4.00 2.55 320 258 1034 657 132 108 432 275 Ti13A4o 1Actom 1270 nw 35.56 70.43 38 0 1344 2662 0 0 0 0 1A-clam 1270 nw 35W 4524 12 0 415 528 12 0 415 528 1Ac1orn 1270 nw 35.56 4524 12 0 427 543 12 0 427 543 P 12C-0sN 0.091 - 2.55 128 235 235 5% 302 0 0 0 0 C 16A30md 0.032 - 0.90 232 1632 1632 1462 3785 252 252 226 585 F 22A-CAI 0.989 - 27.69 0.00 1632 176 4878 0 252 32 886 0 6 c)AED exaysion 0 154 Envelope lossIgain 16540 15400 3063 2515 12 a) IMItation 2989 843 632 178 b) Roomventiation 0 0 0 0 13 Internal gam: Occupants@ 230 0 0 0 0 Applianoas/other 0 0 Subbtal(lines6b13) 19529 16243 3696 2693 Lesexbmalload 0 0 0 0 Leshansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subbtal 19529 16243 3696 2693 15 Ductloads 31% 56% 5998 9055 31% 56% 1136 1501 Total room load 25527 25298 4831 4194 Air required (Cm) 1160 1160 220 192 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. -r l*- wVightsof'[^ 2021Jarv1308:1422 A&p RigtrSUteb Uriversal 201919.021 RSUG8101 Page 1 ...=emslWrigttsod HVAQWYNNEDEV-THEROYALEnp Calc=WB Fror[Doorfaces:N wr➢ghft Right- JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By, 317 ST. LUCIE LN., Fr.. PIERCE, FL 34W Phone: 772466-6799 Fax: 7724666796 Email: QUICKCALCS@,AOL.COM 1 Room name WIC METER BATH 2 5posedwall 0 ft 9A It 3 Room height 9.4 ft heaV=l 9.4 ft heatlmol 4 Room dimensons 7.0 x 9.0 It 7.0 x 9.0 It 5 Room area 63.0 ft' 63.0 IF Ty Construction U-Value Or HTM Area Load number (Bluhr2F) (BWhfiF) or perimeter (ft) (Stun) orsperimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gras N/P/S Hit Cool 6 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 ne 3556 70.43- 0 0 0 0 0 0 0 0 D 11DO 0-490 ne 1022 11.31 0 0 0 0 0 0 0 0 1�/ 13A-4os 0.143 se, 4.00 2S5 0 0 0 0 0 0 0 0 11 —G 1Actan 1270 se 3556 70.95 0 0 0 0 0 0 0 0 W 13A4m 0.143 S 4.00 255 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 85 85 339 215 13A4ors 0.143 nw 4.00 2S5 0 0 0 0 0 0 0 0 1Actom 1270 rw 3556 70.43 0 0 0 0 0 0 0 0 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 1A-clom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 P 12C-O w 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 0.90 2.32 63 63 66 146 63 63 56 146 F 22A-tol 0.989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)Amexrurslon -15 Er Lope losskjain 56 137 1 6441369 12 a) IMlhation 0 0 178 b) RcomventMon I 0 0 0 13 Internal gains O=pan6@ 230 C C 0 AppliancecJfcte 0 Subtotal(linesft13) 56 131822 Lessextamalload 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 131 622 369 15 Ductloads 31% 56% 17 73 37% 56Ye 253 206 Total room load 74 204 1049 75 526 Airrequired(c1m) 3 9 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -Hr wr r+ssofea Right-Sute®Unvers1201919.027 RSU08101 2021-Jarv1308:1422 A_ K ...unerts\Wri ttAHVAQWYNNEDEV- Page g TFIE ROYALE.np Calc=M18 PrortDoorfaces:N wrightser Right.J® Worksheet Job: Entire House DaW: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34M Phone: 772466-6799 Fax 772-4666796 Email: QUICKCALCS@40LCOM 1 Room name M BATH KrrCHEN 2 FVosedwall 8.0 It 8.0 ft 3 Room height 9.4 It heaY=l 9.4 It heal 4 Room dimereons 7.0 x 8.0 ft 1.0 x 192.0 It 5 Room area 56.0 1P 192.0 IF Ty Construction U-value Or HTM Area Load Area (" Load number (BWh4P-°r7 or perimeter (ft) (Bfuh) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gross N/PS Heat Cool 6 U+1 13A-0ors 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 �L—DC 1Aclom 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 11D0 0390 ne 1092 11.31 0 0 0 0 0 0 0 0 13A4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 11 1Aclom 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 w 134-4aos 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 W 13A M 0.143 sx 4.00 2.55 75 75 301 191 0 0 0 0 13A-0xs 0.143 nw 4.00 2S5 0 0 0 0 0 0 0 0 tActom 1270 nw 3556 70.43 0 0 0 0 0 0 0 0 1Actom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1Aciom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 P 12C-09N 0.091 - 2S5 128 0 0 0 0 75 75 192 96 C 16A30md 0.032 - 090 2.32 56 56 50 130 192 192 172 445 F 22A-t)l 0489 - 27.69 0.00 56 I 8 222 i 0 192 8 222 0 6 c) AM exa m -38 Envelope loss/gain 573 283 585 486 12 a) Infiltration 158 45 0 0 b) Raomventilation 0 0 0 0 13 Intamal gains: Occupants @ 230 0 0 0 0 Applianoesbffw 0 0 Subtotal(lins6to13) 731 328 585 4S6 Lesedemalload 0 0 0 0 Leslramer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 731 326 585 486 15 Dud Its 31% 56% 224 183 31% 560/. 180 271 Total room load 955 511 765 756 Air required(o(m) 43 23 351 35 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -rwwr7ghtsoR- 2021-,larF1308:1422 AWN "' ^^ RigItSute®Uriversa1201919.021 RSU08101 Page ...unerts\WrigWftHVAQWYNNEDEV-THEROWLE.np Calc=M18 FrortDoorfares: N wrightsoft- Right-M Worksheet ea,: Entire House Date: QUICK CALCS, INC. BY 317 ST LUCIE LN., Fr. PIERCE. FL 34946 Ptnre: 772-466-6799 Fax 772-466-6796 Emil: QU1CKCALCS@AOL.COM 1 Room name BATH I BEDROOM2 2 Fposdwall 5.0 R 302 R 3 Room height 9A ft heaVmol 9.4 R heaVmol 4 Room dimensions 9.0 x 5.0 R 1A x 1905 it5 Room area 45.0 IF 190.5 ft Ty Constuction U-value Or HTM Area (ft') Load Area Load number (BWhAF-*F) (Btuhtfl or perimeter m (B1uh) or penmeer (it) (Bluh) Heat Cool Gros; N1pr Heat Cool (,loss NIPS Heat Cool 6 V 13A-4= 0.143 ne 4.00 2.55 47 47 188 12C 141 141 565 359 ___o 1Aciom 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 11DO 0390 ne 10.92 11.31 0 0 0 0 0 0 0 0 13A-0as 0.143 s 4.00 255 0 0 0 0 94 74 296 188 11 G tAclom 1270 se 3556 7095 0 0 0 0 20 0 711 1419 w 13A-4= 0.143 s 4.00 2.55 0 0 0 0 40 40 160 102 W moors 0.143 w 4.00 2.55 0 0 0 0 9 9 38 24 13A4s 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1270 nw 35.56 70.43 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 0 0 tActom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 P 12C-Ow OA91 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 090 232 45 45 40 104 191 191 171 442 F 22A-tol 0.989 - 27.69 0.00 45 5 138 0 191 30 835 0 6 c)AEDexwrson 1 -26 145 EnvelopeloWgain 367 198 2775 2679 12 a) InViralion 99 28 598 169 b) Roomeentlation 0 0 0 0 13 Intemalgains: Omopants@ 230 0 0 0 0 Appliancestother 0 0 Sublotal(lines6t>13) 466 226 3373 2847 Les odemal load 1 0 0 0 0 Lestansrer 0 0 0 0 RedishiMon 0 0 0 0 14 Subtotal 466 226 i 3373 2847 15 Ductloads 31% 56% 143 126 31% 56% 1036 1587 Total room load 609 352 4409 4434 Airrequired(dm) 28 16 200 203 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. - 2021-Jarv1308:1422 '-gyp RigttSHE ROYALE.n Caic MJ RSU08101 Page 4 ._unerlslWrigt6oRHVAgWYNNE DEV-hIE ROYALE.np Calc=M18 Frort Doarfao:s: N + wrighttsofi RighW@ Worksheet icix Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 P1ore:772-466-6799 Fax 772466-6796 Erroll: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Evosedwall 16.0 R 130 R 3 Room height 9.4 itheaU000l 9.4 itheaNmol 4 Room dimensons 6D x 10.0 It7.0 x 6A it5 Room area 60.0 ff 42.0 T Ty Construction U-value Or HTM Area Load Area Load number (BhWhrA F) (BtuW or perimeter (R) (Btuh) or perimeter (R) ((3Wh) Heat Cool Gros I NrP/S Heat Cool Gros NIPS Heat Cool 6 13A-4c s 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 re 35.56 70.43 0 0 0 0 0 0 0 0 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 4�/ 13A4ccs 0.143 se 4.00 2.55 56 56 226 144 0 0 0 0 11 L—C IA-dom 1270 se 3556 70.95 0 0 0 0 0 0 0 0 W 13AAocs 0.143 5 4A0 255 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 sv 4.00 2.55 0 0 0 0 56 56 226 144 13A4= 0.143 nw 4.00 2S5 0 0 0 0 0 0 0 0 to-clom 1270 rtw 35M 70.43 0 0 0 0 0 0 0 0 1At1om 1270 nw 3556 4524 0 0 0 0 0 0 0 0 IA-dom 1270 my 35.56 4524 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 94 94 240 121 66 66 168 84 C 16A-30md 0.032 - 090 2.32 60 60 54 139 42 42 38 97 F 22A-bl 0.989 27.69 0.00 60 16 443 0 42 13 360 0 6 c)AED excursion -37 Envelope loss/gam 962 358 791 288 12 a) hflb- ion 119 33 119 33 b) Room lentilalion 0 0 0 0 13 Intemal gains Ooarpa=@ 230 0 0 0 0 Applimoes/other 0 0 Subbal(lines61o13) 1081 391 910 322 Lesekemal load 0 0 0 0 Lestansfer 0 0 0 0 Redis4ibuion 0 0 0 0 14 Subtotal 1081 391 910 32 15 Duct loads 31% 56% 332 218 31% 56% 279 179 Total room load 1413 610 1189 501 Air required(dm) 64 28 54 23 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed - wri9ti>�o7�t- ..Rgtt-SUtesrsal2021 RS 2021Jarv1308:1422 urts@dg�oRNALWV4NEDEV-THEROYALE.np Calc=M8 FortDoorfaxs:N Page 5 wrghtsoft- Right-J@ Worksheet Jcb: Entire House Date: QUICK CALCS, INC. ey. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM 1 Room name SITTING ROOM GREAT/DNING 30.0 itheatlmol 25A ft 3 Room height 9.4 It 9.4 it heatbool 4 Room Cimensions 20.0 x 10.0 it1A x 468.0 it5 Room area 200.0 R 4680 R' Ty Construction U-value Or HTM Area Load number (BWl-ldt-F) (BWhRt� or perimeter (ft) (BWh) or pen (ft) (BWh) Heat Cool Gross Nh'S Heat Cool Gros NiPIS Heat Cool 6 VL13A4ocs 0.143 ne 4.00 2.55 94 73 292 186 235 197 790 502 1Aclom 1270 ne 3556 70.43 0 0 0 0 38 0 1344 2662 11D0 0.390 ne 10.92 11.31 21 21 229 238 0 - 0 0 0 Y�1 13A4o¢ 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 11 I—C 1Actom 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 W 13A-006 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 W 13A-0as 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 13A4o s 0.143 nw 4.00 2.55 188 150 601 382 0 0 0 0 IAclom 1270 nw 3556 70.43 38 0 1344 2662 0 0 0 0 1Actom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1A-clam 1270 nw 3555 4524 0 0 0 0 0 0 0 0 P 12C-09v 0.091 - 2.55 126 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 200 200 179 464 468 468 419 1086 F 22A-tol 0289 - 27.69 0.00 200 301 831 0 468 25 692 0 6 c)AED exursion 402 -440 Envelope loss/gain 3477 4334 3245 3810 12 a) Infiftafion 593 167 494 139 b) Roomlenfilaton 0 0 0 0 13 Internal gains: Omrpans@ 230 0 0 0 0 ApplianoeJother 0 0 Subtotal(lines6to13) 4070 4501 3739 3950 LeseMemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 subtotal 4070 4501 3739 M 15 Duo:loads 31% 56% 1250 2509 31% 56% 1148 2202 Total room load 1 1 5320 7010 1 4888 6151 Air required(dm) 242 321 222 282 Calculations approved bvACCAto meet all requirements of Manual J M Ed. wclwret cwll 2021Jar✓1308:1422 ACICk Ngit-Sate@ Uriversa1201919.021 RSU08101 Page 6 ...0 rtslWdghbuRHVAaWYNNEDEV-THEROYALE.np Calc=M18 Frort Doorfaces:N .p� wrightsoft. Duct System SummaryDate: Entire House S . QUICK CALCS, INC. 317 ST.. LUCIE LN.,Fr.. PIERCE, FL 34946 PInne: 772-466G799 Fa 772-0fieE796 Email: QU1CKCALCS@AOL.COM Project• • For. WYNNEDEVOLPMENT THE ROYALE, FT. PIERCE, FL Bdemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000/0.000 in H2O 0 in/100ft 1160 Crm Giii Supply Branch Detail Table Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 Cfm Name Design (Btuh) Htg (Ctm) Clg (Clm) Design FR Diam (in) H x W (in) Duct Mau Actual Ln (ft) Ftq.Egv Ln (ft) Trunk BATH h 352 28 16 0 0 OxO ShMt 0 0 BEDROOM h 2097 110 96 0 0 Ox0 ShMt 0 0 BEDROOM2 c 2217 100 102 0 0 OxO ShMt 0 0 SEDROOM2-A C 2217 100 102 0 0 OxO ShMt 0 0 BEDROOMA h 2097 110 96 0 0 OxO ShMt 0 0 ENTRY h 610 64 28 0 0 Ox 0 ShMt 0 0 GREAT/DINING C 3076 111 141 0 0 OxO ShMt 0 0 GREATANNING-A C 3076 111 141 0 0 OxO ShMt 0 0 KITCHEN C 756 35 35 0 0 OX 0 ShMt 0 0 LAUNDRY h 501 54 23 0 0 Ox0 ShMt 0 0 M. BATH h 511 43 23 0 0 Ox0 ShMt 0 0 MAS7ERBATH h 575 49 26 0 0 Ox0 ShMt 0 0 srrnNG ROOM c 3505 121 161 0 0 Ox 0 ShMt 0 0 smwG ROOM.A c 3505 121 161 0 0 OxO ShMt 0 0 WIC c 204 3 9 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Size (n) Htg (cfm) Clg (Cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 1 ShMt -F�F wrightsoft- 2021Jarv1308:1423 •..+-% .a.—.�.o-„ MgftSuteOUtie 1201919.021RSLW101 Pagel ACM -.unenslW69Wt ftWAGSWYNNEDEV-7HERO)ALEnp Calc=M,18 FrortDo fay N