Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Pederson Wedi Shower info
I 4 os 2 01 Ply i �r 'll i j oa 02 Vra� 9 03 All products needed to build a wedi Fundo Primo point drain shower are included and provide a single manufacturer warranty.Safe transportation in one box,easy estimating of product quantities needed.The shower floor units feature a strong and pre-sloped surface which can be tiled over immediately whether you choose mosaic size or large format tile. Pre-sloped extension panels are available so that virtually no limit exists for making any size or shape for custom shower designs happen. Naturally,Fundo Primo is insulating keeping surfaces warmer. Especially when compared to traditional mortar bed installations or other currently known methods for building showers such as those including use of sheet— or liquid waterproofing membranes used in an attempt to manage water exposure—wedi Fundo Primo's simplicity and high performance shows. The most unique advantage, however, is the complete and natural core waterproofness of the wedi product and its completeness and range of components that will form an entire assembly system with Fundo Primo engineered to fit and last.This is a true system with full warranty coverage. 01 wedi Building Panel *Found in each kit Fundo Pnmo Showier Base(1) Fo 21 wedi Fundo Primo Showier Base ® wedi 36 in.or 48 in.x 60 in.x 12 in.Building Panels(4) wedi Full Foam Curb,Lean(1) F03 wedi Full Foam Curb Lean . v✓edi Fundo Kit Drain Standard(1) Screws,washers and Putty Knife - wedi Joint Sealant(7 10.5 oz.tubes) wedi Fastener Kit(1,screwstwashers 100 ct_) 05 v✓edi Niche(optional) ® wedi Corner Putty Knife(1) • wedi Mixing valve Flexi Collar(1) wed!Rexi Collar(1) inn wedi Fundo Primo Product Information These added values and its detail perfections eliminate the technical concerns in shower installations.However,this is not where wedi shower systems stop offering its added values.The wedi Fundo shower system adds to your productivity and enables you to provide real value to your customers.Our wedi Fundo Shower systems reduce the installation time for just the shower floor from a 2-3 day process(includes drying times)to only 30 minutes when compared to traditional methods built with pre slope,vinyl liner and final mortar bed.wedi helps you to turn showers into service quicker,cleaner and safer.Especially for our contractors,Fundo Primo helps to get to setting tile faster and on a much more consistent and the friendly surface.Customers will appreciate the "no noise and no dirt/dust"installation.The wedi products do not contain harmful ingredients providing peace of mind to contractors and end users. Note for Installation Optionally a glue drain can be obtained from wedi.For a cement glue connection,the floor pipe must be cut 2 1/4"below the surface of the subfloor. Optionally a brass drain can be obtained from wedi.The installation proceeds as shown for the standard ABS drain provided with each Fundo Primo base. Drain to Base Assembly Caulking nut Rubber caulking gasket Drain body ABS to ABS seal with wedi Joint Sealant :ATM Rubber gasket Fiber gasket - Locking nut 2 in- (50.8 mm) The shower base may be extended using a pre-sloped wedi wedi shower bases thicker than 1 V2 in.where an extension is con- extension panel. nected require a wedi building panel be placed under the extension panel to adjust for a proper connection fit. Note 2 in.outside diameter is nominal(2 3/8 in.for PVC/ABS schedule 40 pipe and 2 in.for cast iron/copper).Several Fundo Primo models naturally feature different perimeter height or thickness at the edge.Therefore,pre-made standard notch connections of wedi curbs must be modified in the field for a tight fit to the bases.Ramps and Extension panels can naturally not fit to all models and might be modified in the field as well. im wedi Fundo Prim& Installation Before Installation: 45>9 •Have 2 x 4 blocking installed over bottom plate between studs along to support wedi Building Panel to shower base transition area. •Subfloor is stable,even and load bearing,and meets deflection criteria of maximum U360 as per IRC.Wooden or concrete structural substrates are dry and sufficiently load bearing considering live and dead load.Wood and Steel framing is sufficiently load bearing,plum and square. •Floor drain assembly below floor is stabilized,fixed and supported in posi- tion,and will not sink under water load. w •only wedi products(Building Panels,Curb,Joint Sealant and Fasteners)are used for wedi Fundo Shower System assembly. ] •Installer has received instructions from wedi Technical Sales Staff or is in- s formed about proper installation methods as described. •wedi Shower Bases can be cut to size using a skilsaw.The Z notch channel must be remade and cleaned from sawdust or other possible contamination " fi •This manual extends and is not in conflict with applicable state or local plumbing codes for waterproofed areas,including shower system and •Seams in the assembly,which are not flat transitions or right angle other wet room installations.wedi Shower Systems or other wet room inside corner connections,are treated with these extra steps: installations in which non-wedi product is also used require specific • Assembly parts are installed tight and offer a minimum of in.wide project recommendations by wedi and may reduce the extent and instal- continuous contact/adhesion surface between two parts,inside lation area of protection offered by wedi's warranty. which wedi joint sealant is continuously applied. •Ensure that no fasteners are used and penetrate through any horizontal • wedi joint sealant is applied over these seams topically,and 1 in. building panel or shower base surfaces in shower or immediate wet wide on both sides of the seam. rooms.This includes tub decks,pony shower wall tops,curb tops made • wedi mesh tape is installed over these seams and covered with joint from building panels,seat tops.wedi panels in such areas are installed sealant 1 in.wide on both sides of the seam. in a full surface applied thinset mortar setting bed. � 5 URN Cut the 2"(50.8 mm)pipe flush(or max 1/8"[3.2 mm]above)to the Set up a continuous 1/4"(6.4 Drop the drain body firmly into floor construction.Make sure that the cut out fits to the Fundo panel mm) bead of wedi sealant the sealant. drain.Cut out a 5"(127 mm)diameter hole around the 2"(50.8 mm) along the top side of the wedi pipe to allow for the wedi drain to be inserted into the subfloor while the Fundos' valve groove profile. cut out area must remain free of deflection.The drain and trap have to Optionally you can apply the be sturdily fastened to the sub floor.Assemble the drain unit following bead on the underside of the the instruction drawing. main drain body's flange.This will help keeping sealant off the threads of the main drain body when it is inserted. a f E a Turn the Fundo base upside Tighten the gaskets firmly Skim coat the thinset ANSI 118.4 and comb through with a 1/4"x 1/4" down and apply the rubber to the bases' steel ring using (6.4 x 6.4 mm)notched trowel. Channels pointing to the entrance. and the fiber gasket. the locking nut. Make sure Trowel the thinset on the rear side of the Fundo again using a 1/4"x 1/4" the drain body is still safely (6.4 x 6.4 mm)notched trowel.There are different ways to ensure good received in the valve-bead of bond of the wedi Base to the subfloor.Required is a setting bed thick- sealant. Smooth out excess ness of min.3/16"(4.8 mm)and max.of 5/16"(7.9 mm)(compressed). sealant over the drain body's Applying thinset on both,wedi Base and subfloor,is recommended to flange surface. achieve full surface coverage adhesion.Another best practice is to use fast setting mortar to achieve faster bond and adhesion, 5 4 � Press the Fundo firmly into Set up the rubber caulking Tighten (squeeze) the rubber Set up a continuous 12"(12.7 the thinset bed,ensuring that gasket(with the beveled side caulking gasket firmly with the mm)bead of wedi Joint Seal- the installation is level and up)around the 2"(50.8 mm) caulking nut(use a flat headed ant along the pans channel on void free.Apply some weight pipe in the subfloor.The rub- screwdriver) and finally insert the outer perimeter and only equally and leave on surface ber gasket must be flush with the plastic frame and strainer in areas where you can imme- and drain area to allow the the upper end of the 2"(50.8 on top(without adhesive).The diately install a wedi Building thinset to initially cure without mm)ABS or PVC pipe. frame and strainer will be held Panel into the fresh sealant. being disturbed (e.g. thinset Do not use any lubricants. in a grout joint only once tiling bags). commences.0o not tighten the gasket prior to 60 minutes after the threaded drain part was sealed into the shower base. e ' Push the wedi Building Panel all the way into the channel of the shower Apply continuous 12"(12.7 mm)beads of sealant between all connec- base channel and its bead of sealant.Smooth out any pushed out seal- tions of panels and install with tightly butted seams.Excess sealant must ant on inside seam using a putty knife.Fasten the panels directly to the be spread flat with a putty knife.All seams and fastener heads in the studs starting 1 ft.(304.8 mm)above the base and in corners while assembly are covered vAth a secondary 12"(12.7 mm)bead of sealant and keeping the board pushed down into the channel,and set the fasteners spread flat.The seams should be covered 1"(25.4 mm)on either side of at a rate of 1 fastener per 1 ft.(304.8 mm).1 extra fastener is set into seam.All fastenerlwashers are covered with sealant stretching 1"(25.4 the seam to the next panel to create a flush transition.wedi requires mm)over the washer edges. vvedi Building Panels to be installed in all areas exposed to water and in any case no lower than 6"(152.4 mm)above all water inlet fixtures. Tn� wedi Niches are installed in a cut out in the wedi wall and attached with A continuous 1/2"(12.7 mm)bead of sealant is set into the channel it's flange right into the center of 16"(406.4 mm)o.c.studs.wedi Joint and along the vertical curb notch part.A circle of 1/2"(12.7 mm)seal- Sealant is set along the connection of wall to niche. ant bead is set against the wall panels(and)or the curb sides where the 2 Fasteners on each side of the niche are set to create a flush transition curb attaches.A 1/2" x 1/2"(12.7 x 12.7 mm)bed of thinset mortar to the wall panels.Another 1/2"(12.7 mm)bead of wedi Joint Sealant is applied to the subfloor and a skim coat on the bottom surface of the is spread over fasteners and seams. curb as a best practice.The tightly fitting curb is pressed into the con- nection area.Weight is applied for a minimum of 30 minutes on and against the curb(from outside)and another 1/2"(12.7 mm)bead of sealant is applied over all curb seams and spread flat.The seams must be covered 1"(25.4 mm)either side of a seam. For the installation to properly work it is critical to waterproof all Curb connection notches must be cut to fit select Primo bases penetrations of the wedi product such as shower valves and shower with perimeter thickness higher than 1 12"(38.1 mm).Do not heads using the appropriate sealing gaskets for the application.The place fasteners in horizontal areas or mesh treatment in angled wedi Mixing Valve Flexi Collar and wedi Flexi Collar(for 12"—3/4" corner seams. [12.7—19 mm]shower pipe protrusions)are used for these applica- tions and are part of the wedi System complete warranty. After Installation All visible joints or seams in the installation are visibly covered and reinforced with wedi Joint Sealant applied flat over the seams.Coverage of wedi Joint Sealant over all seams should be at least 1 inch(25.4 mm)on either side of the seam.The wedi Joint Sealant should be no less than 1/16 inch(1.6 mm) thick for strength,Do not add mesh tape into the wedi Joint Sealant.This may only put the waterproofing performance at risk and will not strengthen the sealant's or system's resistance against movement related stresses.Once wedi Joint Sealant application over all shower system seams has been completed, an optional water flood test may be performed as early as 2 hours later.The test should not exceed 24 hours and nor should the water level exceed the height of the perimeter seams so that the fresh sealant may continue to a full cure without too much weight added during that process.wedi recommends to test at least the drain connection for its proper seal while a full surface flood test is not technically required for non-absorbing products like wedi but may be required by a building inspection department.When tiling commences,no premixed and organic("mastic")file adhesives must be used over wedi Systems in any wet area installation.When tiling the wedi Shower Bases,ind.extensions or ramps,tile thickness should generally not be less than 1/8"(3.2 mm).Choose setting materials appropriate for the type of stone,ceramic or glass tile as well as for a wet area installation.Tile with a square size of 2 x 2" (50.8 x 50.8 mm)or more may be installed using a polymer modified cement based tile adhesive and grout.Tile with a square size of less than 2 x 2"(50.8 x 50.8 mm)may be installed using a polymer modified cement based the adhesive and require 100%solids epoxy grout.Tile with a square size of 1 x 1" (25.4 x 25.4 mm)or less must be installed using a 100%solids epoxy file adhesive and grout Only non-flat bottom pebble stone installations including in part small mosaics may be installed using polymer modified cement based the adhesive and grout,all fiat bottom pebble stone installation are subject to the general tile size based setting materials recommendation outlined above.When installing non-square tile,the length of the shortest file edge(s)is considered as its square size for the purpose of determining the choice of the setting materials as outlined above. All file installations designed to receive heavier paint loads such as from wheelchair use,must be grouted using 100%solids epoxy grout.large format tile may be installed over vvedi Fundo shower bases.Cuts may have to be made in consideration of the base's slope lines and so that such tie can always be fully supported by the file adhesive setting bed and the surface of the wedi Base.Tile adhesive coverage under the file must be 95%and special care must be taken to achieve good transfer of adhesive to wedi's Shower Base when working with mesh backed tile.Use only solvent and acid free cleaners and sealers on tile and grout installed over wedi product and apply such products only in amounts as needed to treat the surface materials without drenching the substrate.Follow setting materials manufacturer's recommendations and contact wedi with any questions or regarding applications not covered here. Inn +on Lo\tar tJ� (tens o+ntaPt'onalESQtbed,+nt0the F�S�e flex+b\e 9rOut 1 ou9h the th.M need to rase the Oj \NedV �O�e� et�een Part andmmrn9 uP the k PAaa+o evens onm y beaslt\s n°t kbe al 1uQ r n° �u5 no, t oreate au YQa d the d\{n t�eeded,the een5+on co\\ screv�s) to base ho\e aQ d.the caulk 1°re(mrsstbe odnt+nuthE firam�tOver. \nsert coder fran e ht if Pad is nee re the tIn+nse L VayE and insert be\0v, cap be out to he+9 \hereto sit e(i\Cut extef\,° coV\a<to Iron m be\oW jh wed+tnstaV\a dra+n N toy d fur�tOnin9 01 the vJedrtram nece r a vjedi C0ve w e �o�er{tan` Y i OPtrOpai E(tensron cow" WSJ t�� x 59" , 3 B a - a c c _ 3 a oo= _ 4,� section A-A (1 : 10) sHO .0 N GI T V = 3 c o C N i M !'L •�O O O i mO7O Lnl O � ~ IE 1= 3 d 2,60% 2,60% d -—-—-—-—-—-—-—-— �- — 1 M A A o i Ln N i i 291/211 1/11 60" (, top view( 1 : 10 ) = NOTE: Detail B ( 1 : 5 ) E slope 1/4"/ft minimum in all areas of shower base surface a.0t view ( 1 : 30 ) �i E m 3 v � M a zak" Z 0-0 0 0 1 31 Benennung/designation c rn E Kunde/ client : wedi corporation wedi Fundo USA Y X 5' Ey BV/ BP : Art: 07-37-35/506 N Ca s atum ame date name a g 30.11.2009 Vo wedi GmbHdrawn �® 2D Hollefeldstrasse 51 yved� L drawn oz.o5.zolz vo N ■■■48282 Emsdetten O Pro r. c u wedi Vertrieb/sales Fon+49(0)2572/156-0 s Fertigungszustand/Bautoleranzen: Fax+49(0)2572/156-133 „ o B Anpassung Bem. 24.07.2014 L.S. finished condition/tolerances: oath DIN 18202 wedi Projektabteilung/project dept. Fon+49(0)2572/156-0 w u A Standardisierung 02.05.2012 d Fax+49(0)2572/156-239 oj usg. Anderung Datum name Made in Zoli DIN A4 niename:073735506_FU_USA_3'x 5'_Kundenzeichn ngdpt a E Q .r/ gradient:2,08% 3 a a �90 3 a 0 via m� E � v� r 15,v .0 N Q7 a u c-� 3 = � o v'0` N _ M — p C u= N 3 ,-I 1/zip front view ( 1 : 1 ) 2„ 0 �o v= ( 1 : 20 ) v E top view ( 1 : 1 ) a't d E,m 3 �' Z.�ngnganqmma Z 00 00 62 86 n dnwngnum6a Benennung/designation 3 � c E Kunde/ client : wedi Corporation wedi shower curb ESE BV/ BP : - - - C>N full form - 60"/ Art.: 07-43-19/007 vW Cn i5 u,°= Datum Name sU date name a, v 28.10.2014 ds wedi GmbHdrawn �® 2D Hollefeldstrasse 51 wwa, N drawn 28.10.2014 ds 48282 Emsdetten ■ ■ �£ v O1� O1 Pro r. C E�c=, wedi Vertrieb/sales Fon+49(0)2572/156-0 s Fe,Igungszustand/Bautoleranzen: Fax+49(0)2572/156-133 v rn> finished condition/tolerances: wedi Projektabteilung/project dept. Fon+49(0)2572/156-0 N 0 v nach DIN 18202 0 v Fax+49(0)2572/156-239 a usg. Anderung Datum Nam MaBe in Zoll 5 2 ilk= modification date nameldimensions In in h I DIN A4 filename:074319007_shower curb_USA.Ipt Technical Properties ® wedi systems ASTM C 578* Standard Specification for Rigid, Compliant Cellular Polystyrene Thermal Conductivity* 75°F(25°C)-ASTM C518 0,23 Bbtu in/hr F R-Value* 75°F(25°)-ASTM C518 4.3hr ft.2 F/Btufin(R Value for 1"wedi=4.3) Tensile Strength*** ASTM C297 65 psi Shear Strength* Under conditions required in ANSI A118.10-1999 28 day Shear Strength: 95 psi 84 day Shear Strength: 100 psi 100 day Shear Strength: 98 psi Waterproof*** ASTM D4068/ANSI At 18.10-1999 Passed Waterproofness of Assembly*** ASTM E331 Passed,wedi Fundo Kit assembly(complete system) Water Vapor Transmission**** ASTM E 96-2016 Permeance/Perms 0,03 and WVT(grains/h x ft2)0.05 Capillarity*** 0 Fungus/Bacteria Resistance*** ASTM G21 Passed,No Growth Flexural Strength* ASTM C947 627 psi Robinson Floor Test* ASTM C627 Heavy duty commercial use,passed Fastener Pull Through* ASTM C473 Wet 131.8 IbJDry 196.2 lb. Temperature Limits* 58/+175°F Freeze&Thaw* ASTM C666-25 Cycles No disintegration/change Accelerated Aging* AC 71-25 Cycles No disintegration Linear Variation*** AC 159/ASTM 1037-39 Passed,less than 0.07% Surface Burning Characteristics* ASTM E84-16(NFPA 255,ANSI/UL 723,UBC 8-1) Flame Spread Index(FSI): 20 Tested as required without file on Building Panel Smoke Developed Index(SDI): 70 surface Classification: Class A Floor and Trench Drain Compliance** ASME A112.18.2 Passed,Compliant(ICC PMG 1189) 'wedi Building Panel tested 'Consult wedi for proper subfloor,tile,setting materials choice to uvedi Fundo Floor Systems tested design heavy duty commercial use floor surfaces. '•"Entire wedi sho—system tested •"•"Vapor 85 assembly inct.seams".Test standard is ASTM E 96 Method E at 100 F'and 90%R.H. 48 in. 60 in. 1/4 in. 13.9 lb. 48 in. 60 in. 1/2 in. 14Alb. Approvals and certificates applicable City of New York, Fundo Shower Systems Meets all applicable TCNA handbook to entire Fundo Shower System incl. MEA 912-52-SM &Building Panels: ANSVISO Standards recognized for wall, wedi Building Panel ICC PMG 1189 incl.ANSI 118.10 and floor,countertop,& (for USA and Canada) IAPMO PIS 106 more applications City of Los Angeles BBA(British Board DIN EN ISO 9001 CE marked Approval of Agr@ment) Diverse State Approvals SA1 Global Watermark Certified(Australia&New Zealand) Codemark Certified(Australia&New Zealand) Contains no unbonded fire retardants like HBCD(Hexabromocydododecane)which has been banned in Canada and is a toxic substance of high concern with the US EPA. 1A7 ICC-PMG 1189 Report m National wilding Code Compliances MENEMENEENEEM CS1 DIVISION:22 00 00—PLUMBING Section:22 40 00—Plumbing Fixtures(Shower System Kit) Product certification system The]CC-ES product certification system includes testing samples taken from the market or supplier's stock,or a combination of both,to verify compliance with applicable codes and standards.The system also involves factory inspections,and assessment and surveillance of the supplier's quality system. Product wedi Fundo Shower System and Tile Backer Board Underiayments Listee wedi Corporation-1160 Pierson Drive,Batavia,IL 60510 www.wedicorp.com Compliance with the following codes 2021,2018,2015,2012 and 2009 International Plumbing Code's(IPC) 2021,2018,2015,2012 and 2009 International Residential Code`(IRC) 2021,2018,2015,2012 and 2009 International Building CodeO(IBC) 2018,2015,2012 and 2009 National Standard Plumbing Codeg(NSPC) 2018,2015,2012 and 2009 Uniform Plumbing Coded(UPC)* 2015,2010 and 2005 National Plumbing Code of Canada** *Uniform Plumbing Code is a copyrighted publication if the International Association of Plumbing and Mechanical Officials **National Plumbing Code of Canada is a copyrighted publication of National Research Council Canada Compliance with the following standards ANSI A 118.10-2014,Load Bearing,Bonded,Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installations ASME A 112.6.3-2016,Floor and Trench Drains ]CC-ES EG 159,Evaluation Guideline for Composite Backer Board(Approved Dec 2004) ASTM E 96-2016,Standard Test Methods for Water Vapor Transmission of Materials ASTM E 331-00(R16),ASTM E331-00(2016)Standard Test Method for Water Penetration of Exterior Windows,Skylights,Doors,and Curtain Walls by Uniform Static Air Pressure Difference ICC-ES AC 71,Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water Resistive Barriers(Approved Feb 2003,Ed Revised Nov 2018) IAPMO PS 46-2012,Field-Fabricated Tiling Kits IAPMO PS 106-2015el,Tileable Shower Receptors and Shower Kits Identification Packaging label for each system shall include the manufacturer's name or trademark as well as the ICC-ES PMG certification mark. Installation The wedi Fundo Shower Systems shall be installed in accordance with the manufacturer's published instructions and the applicable code(s). The wedi Fundo Shower system components shall be assembled and can be customized in the field. When provided drains must comply with ASME At 12.18.21CSA B125.2 as applicable.The wedi pre- sloped,ready-to-tile shower bases may be used in lieu of a CSA B45.5/APMO Z124 plastic shower receptors or any liner based shower installations.The wedi drain units do not require weep holes. Listed Models and Characteristics The wedi Fundo Shower Systems consist of the following a)The wedi waterproof Fundo show bases are waterproof,pre-sloped,ready-to-tile floor units.The shower bases with linear and point drainage include factory sealed parts integrated into the floor bases and can be installed with or without curbs in recess,barrier free installations, b)The wedi waterproof building panels which are;engineered as a general purpose backer board and underlaymentfor tile as well as an integral part of the Fundo shower system and consist of a rigid extruded polystyrene foam covered on both sides with a cement-based resin surface and rein- forcing mesh for durability and bond performance with the adhesives. c)the wedi Vapor 85 Building Panel which may be used with or without wedi shower systems.R is a specialized building panel featuring the original wedi Building Panel but with its vapor exposed side protected by wedi Subliner Dry.The wadi Vapor,85 was tested to ASTM E96 Procedure E as a com- plete assembly with the wedi 620 joint sealing membrane and wedi Subliner Dry sealing tape over seams and fastener points and was found to have a perm rating of 0.03 perms which meets the permeance rating requirement of 0.5 perm or less and can be used in continuous use steam shower/ room applications without additional vapor retarders in accordance with Tile Council of North Amer- ica(TCNA)2014 Handbook for Ceramic Glass and Stone Tile Installation(SR613-14 and 5R614-14). d)The wedi waterproof Fundo Shower system accessories which may include the following water- proof components:wedi pre-sloped curbs,wedi niches,wedi seats,wedi fasteners,wedi drain cover plates,wedi sealants,wedi Fundo drains,wedi Subliner sheet waterproofing membrane system and tapes,with wedi Sublimer Dry Bonding flange drain„vredi Subliner Dry Tub Sealing Tape. The wedi Fundo family line includes the following:Primo,Riolito Neo,Riolito Neo Modular,Rici ino, Discreto,t gno and OneStep.The wedi Fundo Shower system components and assembly for shower installations were proven to be waterproof,water-resistant,and mold resistant when tested in accordance with Al 18,10-2014 and ASTM E331.The wedi drains have found to comply with with ASME At 12.1&2/GSA B125.2 and do not require weep holes. Conditions of Listing 1.The wedi Fundo Shower Systems shall be installed in accordance with the manufacturer's published instructions and the applicable code(s). 2.The wedi Fundo Shower Systems are manufactured by wedi GmbH,in Emsdetten,Germany and in Batavia,Illinois,USA under a quality control program with annual surveillance inspections by[CC-ES. Find Current Report on wvwv.icc-es.org or wvwa.wedicorp.com tag IES ICMES P G Product Certificate PMG-1189 ,. Effective Date:May 2021 This listing is subject to re-examination in one year. www.icc-es-pmg.org ( (800)423-6587 ( (562)699-0543 A Subsidiary of the international Code Counci/0 CSI: DIVISION: 22 00 00—PLUMBING Section: 22 40 00—Plumbing Fixtures(Shower System Kit) Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier's stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier's quality system. Product: wedi Fundo Shower System and Tile Backer Board Underlayments Listee: wedi Corporation 1160 Pierson Drive, Suite 102 Batavia, IL 60510 www.wedicorp.com Compliance with the following codes: 2021, 2018, 2015, 2012 and 2009 International Plumbing Code®(IPC) 2021, 2018, 2015, 2012 and 2009 International Residential Codee(IRC) 2021, 2018, 2015, 2012 and 2009 International Building Code®(IBC) 2018, 2015, 2012 and 2009 National Standard Plumbing Code®(NSPC) 2021, 2018, 2015, 2012 and 2009 Uniform Plumbing Code®(UPC)* 2015, 2010 and 2005 National Plumbing Code of Canada** *Uniform Plumbing Code is a copyrighted publication if the International Association of Plumbing and Mechanical Officials **National Plumbing Code of Canada is a copyrighted publication of National Research Council Canada Compliance with the following standard: ANSI All 18.10-2020, Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installations ASME All 12.6.3-2019, Floor and Trench Drains ASTM E 96-2016, Standard Test Methods for Water Vapor Transmission of Materials ASTM E 331-00(R16), ASTM E331-00(2016) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ICC-ES EG 159, Evaluation Guideline for Composite Backer Board (Approved Dec 2004) ICC-ES AC 71, Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water Resistive Barriers (Approved Feb 2003, Ed Revised Nov 2018) IAPMO PS 46-2012, Field-Fabricated Tiling Kits IAPMO PS 106-2015e1, Tileable Shower Receptors and Shower Kits Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this listing,or as to any product covered by the listing. MISS 1= 4 r Copyright©2021 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 2 PMG-1189 1 Most Widely Accepted and Trusted Page 2 of 2 Identification: Packaging label for each system shall include the manufacturer's name or trademark as well as the ICC-ES PMG certification mark. Installation: The wedi Fundo Shower Systems shall be installed in accordance with the manufacturer's published instructions and the applicable code(s). The wedi Fundo Shower system components shall be assembled and can be customized in the field. When provided drains must comply with ASME Al 12.18.2/CSA B125.2 as applicable. The wedi pre- sloped, ready-to-tile shower bases may be used in lieu of a CSA B45.5/IAPMO Z124 plastic shower receptors or any liner based shower installations. The wedi drain units do not require weep holes. Models: The wedi Fundo Shower Systems consist of the following: a) The wedi waterproof Fundo shower bases are waterproof, pre-sloped, ready-to-tile floor units. The shower bases with linear and point drainage include factory sealed parts integrated into the floor base and can be installed with or without curbs in recessed, barrier free installations b) The wedi waterproof building panels which are engineered as a general purpose backer board and underlayment for tile as well as an integral part of the Fundo shower system and consist of a rigid extruded polystyrene foam covered on both sides with a cement-based resin surface and reinforcing mesh for durability and bond performance with tile adhesives. c) The wedi Vapor 85 Building Panel which may be used with or without wedi shower systems. It is a specialized building panel featuring the original wedi Building Panel but with its vapor exposed side protected by wedi Subliner Dry. The wedi Vapor 85 was tested to ASTM E96 Procedure E as a complete assembly with the wedi 620 joint sealing membrane and wedi Subliner Dry sealing tape over seams and fastener points and was found to have a perm rating of 0.03 perms which meets the permeance rating requirement of 0.5 perm or less and can be used in continuous use steam shower/room applications without additional vapor retarders in accordance with Tile Council of North America (TCNA)2014 Handbook for Ceramic Glass and Stone Tile Installation (SR613-14 and SR614-14). d) The wedi waterproof Fundo Shower system accessories which may include the following waterproof components: wedi presloped curbs, wedi niches, wedi seats, wedi benches, wedi ADA compliant ramps, wedi vapor barrier for steam room installations, wedi fasteners, wedi drain cover plates, wedi sealants, wedi Fundo drains, wedi Subliner sheet waterproofing membrane system and tapes, with Subliner Dry Bonding Flange drain, wedi Subliner Dry Tub Sealing Tape. The wedi Fundo family line includes the following: Primo, Riolito Neo, Riolito Neo Modular, Riofino, Discreto, Ligno and Onestep. The wedi Fundo Shower system components and assembly for shower installations were proven to be waterproof, water-resistant, and mold resistant when tested in accordance with Al 18.10-2014 and ASTM E331. The wedi drains have found to comply with ASME A112.18.2/CSA B125.2 and do not require weep holes. Conditions of Listing: 1. The wedi Fundo Shower Systems, Building Panels and System Accessories shall be installed in accordance with the manufacturer's published instructions and the applicable code(s). 2. The wedi Fundo Shower Systems are under a quality control program with annual surveillance inspections by ICC-ES.