HomeMy WebLinkAboutAPPROVED Boral Estate 21042005
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 1 of 7
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in
Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Estate “S” Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 21-0323.05 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 2 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Estate “S” Concrete Roof Tile, as manufactured by Boral Roofing, LLC in
Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building
Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by
applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127
using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Dimensions
Test
Specifications
Product
Description
Boral Estate ‘S’ Roof Tile Length = 16-1/2"
Width = 13"
TAS 112
Type 1b
Class III
Low profile, interlocking, extruded
concrete roof tile equipped with two nail
hole and double roll ribs. For direct deck
or battened nail-on, mortar or adhesive
set applications.
Trim Pieces l = varies
w = varies
varying thickness
TAS 112 Accessory trim, concrete roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name Product Description Manufacturer
(With Current NOA)
ICP Adhesives Polyset® AH-160
Two component polyurethane
foam adhesive.
ICP Adhesives and Sealants, Inc.
TILE BONDTM Roof Tile Adhesive Single component polyurethane
foam roof tile adhesive.
The Dow Chemical Company
Touch ‘N Seal StormBond® 2 Two-
Component Polyurethane Roof Tile
Adhesive
Two component polyurethane
foam adhesive.
DAP Foam, Inc.
Touch ‘N Seal StormBond® One
Component Polyurethane Roof Tile
Adhesive
One component polyurethane
foam adhesive.
DAP Foam, Inc.
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 3 of 7
2.3 EVIDENCE SUBMITTED:
Test Agency
Test Identifier Test Name/Report Date
Redland Technologies 7161-03 PA 102 Dec. 1991
7161-03 PA 102(A) Dec. 1991
7161-03 PA 108 Dec. 1991
P0402 Withdrawal Resistance Testing of
screw vs. smooth shank nails
Sept. 1993
P0631-01 PA 108 July 1994
Letter Dated Aug. 1,
1994
PA 108
Aug. 1994
Professional Service Industries, Inc.
224-47099 PA 112 Sept. 1994
The Center for Applied 94-060B PA 101 March, 1994
Engineering, Inc. 94-084 PA 101 May 1994
25-7094-1 PA 102 Oct. 1994
25-7094-7 PA 102 Oct. 1994
25-7094-4 PA 102 Oct. 1994
Project No. 307025
Test #MDC-76
PA 100 Oct. 1994
25-7183-1 PA 102 Feb. 1995
25-7183-2 PA 102 Feb. 1995
25-7214-2 PA 102 March, 1995
25-7214-6 PA 102 March, 1995
Celotex Corporation Testing Services 528454-2-1
520109-2
PA 101 Sep. 1998
Dec. 1998
Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999
IBA Consultants, Inc. 2381-264 TAS 112 01/08/08
American Test Lab of South Florida RT0201.02-21 TAS 112 02/12/21
PRI Construction Material DAPF-004-02-05 TAS 101 07/26/18
Technologies DAPF-004-02-07 TAS 101 07/26/18
2002T0003.04 TAS 101 11/06/20
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 4 of 7
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 Minimum slope 4/12 for mechanically attached tile.
3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Boral Estate “S” Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (l x w )
Tile Profile
Weight-W (lbf) Length-l (ft.) Width-w (ft.)
Boral Estate ‘S’ Roof Tile 10.0 1.375 1.08
Table 2: Aerodynamic Multipliers - (ft3)
Tile Profile (ft3)
Batten Application
(ft3)
Direct Deck Application
Boral Estate ‘S’ Roof Tile 0.267 0.289
Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf)
Tile
Profile
3":12" 4":12" 5":12" 6":12" Greater than
7":12"
Boral Estate ‘S’
Roof Tile
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
N/A 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 5 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail-On Systems
Tile
Profile
Fastener Type Direct Deck
(min 15/32” plywood)
Direct Deck
(min. 19/32” plywood)
Battens
Boral Estate
‘S’ Roof Tile
2-10d Ring Shank Nails 27.8 37.4 28.8
1-10d Smooth or Screw
Shank Nail2
8.8 11.8 4.1
2-10d Smooth or Screw
Shank Nails
16.4 21.9 7.1
1 #8 Screw2 25.8 25.8 22.9
2 #8 Screw 47.1 47.1 49.1
1-10d Smooth or Screw
Shank Nail (Field Clip)2
24.3 24.3 24.2
1-10d Smooth or Screw
Shank Nail (Eave Clip)2
19.0 19.0 22.1
2-10d Smooth or Screw
Shank Nails (Field Clip)
35.5 35.5 34.8
2-10d Smooth or Screw
Shank Nails (Eave Clip)
31.9 31.9 32.2
2-10d Ring Shank Nails1 43.0 67.5 50.9
1 Installation with a 4" tile headlap and fasteners are located a min. of 2½" from head of tile.
2 When using only one fastener use the hole that is approximately 4-3/4” away from interlocking edge.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Paddy Adhesive3 Set Systems
+
Tile Profile Tile Application Minimum Attachment
Resistance
Boral Estate ‘S’ Roof Tile TILE BOND™ Roof Tile Adhesive 674
TILE BOND™ Roof Tile Adhesive 355
ICP Adhesives Polyset® AH-160 26.16
Touch ‘N Seal StormBond® 2 357
Touch ‘N Seal StormBond® (one component)
628
3 See foam adhesive manufacturer’s component approval for installation requirements.
4 Medium paddy weight of 16 grams per paddy of TILE BOND™ Roof Tile Adhesive
5 Medium paddy weight of 8 grams per paddy of TILE BOND™ Roof Tile Adhesive
6 Medium paddy weight of 8 grams per paddy of Polyset® AH-160
7 Medium paddy weight of 8 grams per paddy of Touch ‘N Seal StormBond ® 2
8 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 5 grams on overlap of tile of
Touch ‘N Seal StormBond ® (one component)
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 6 of 7
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Paddy Adhesive Set Systems
Tile
Profile
Tile Application Minimum Attachment
Resistance
Boral Estate ‘S’ Roof Tile ICP Adhesives Polyset® AH-160 86.69
ICP Adhesives Polyset® AH-160 45.510
Touch ‘N Seal StormBond® 2
6011
9 Large paddy weight of 54 grams of Polyset® AH-160
10 Large paddy weight of 24 grams of Polyset® AH-160
11 Large paddy weight of 60 grams of Touch ‘N Seal StormBond ® 2
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf)
for Mortar or Adhesive Set Systems
Tile
Profile
Tile Application Minimum Attachment
Resistance
Boral Estate ‘S’ Roof
Tile
Mortar Set 20.60
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade County Product Control Approved".
OR
BORAL ESTATE “S” TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No. 21-0420.05
Expiration Date: 08/23/26
Approval Date: 08/26/21
Page 7 of 7
PROFILE DRAWING
BORAL ESTATE “S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE