• FL# FL10674-1116 RECEIVED
Application Type Revision
Code Version 2020 O C T 2 6
2021
Application Status Approved St.Lucie County
Permitting
Comments
Archived
Product Manufacturer Owens Coming -,:VIEWED Fu
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659 y,(
(740)404-7829 � COMPLIA
greg.keeler@owenscoming.com
—JCIE COON
Authorized Signature Greg Keeler BOCC
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative FILE COPY
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R16 COI 2020 01 COI NIEMINEN.pLif
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2019
Equivalence of Product Standards
Certified By
Sections from the Code
https://floridabuilding.org/pr/pr_app_db.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReg[CQ8ucR6ixEAIpOjcKTwWbw%3d%3d 1/2
10/20/21,2:27 PM Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 12/11/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab, laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R16.pdf
Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE-59166
Design Pressure: N/A I Created by Independent Third Party:Yes
Other: Refer to ER,Section S. Evaluation Reports
i FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.pdf
Created by Independent Third Party:Yes
$ack ?iexe
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
2® ® gig
Credit Card
Safe
httpsJ/floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAIpOjcKTwWbw°/a3d%3d 2/2
ENERGY STAR" Product Attributes
IS FOR ROOFS TOO Warranty Length*
Limited Lifetime*(for as long as you own your home)
r� Similar to the energy-efficient Wind Resistance Limited Warranty'
appliances in your home, roofing
130 MPH
products can help provide Algae Resistance Limited Warranty
energy-saving qualities.Owens Corning' 10 Years
ENERGY STAR'qualified shingles can help TRU PROtection'Non-Prorated Limited Warranty Period
reduce your heating and cooling bills when 10 Years
installed properly,These shingles reflect solar
energy,helping to decrease the amount of heat TruDefinition" Duration"Shingles
transferred to a home's interior—and the Product Specifications
amount of air conditioning needed to keep it S1Ze 131/4"X 39%"
comfortable.Actual savings will vary based on Application Exposure 5-%"
geographic location and individual building Shingles per Bundle Not less than 20
characteristics. Call 1-800-GET-PINK'or Average Shingle Count per 3 Bundles 64
1-888-STAR YES for more information.
Average Coverage per 3 Bundles 98.4 sq.ft.
Applicable Standards and Codes
ASTM D228
ASTM D3018(Type 1)
ASTM D3161 (Class F Wind Resistance)
ASTM D3462
ASTM D7158(Class H Wind Resistance)
ASTM E108/UL 790(Class A Fire Resistance)
ICC-ES AC438'
PRI ER 137BE01
Shasta White color meets ENERGY STAR'requirements for initial
solar reflectance of 0.25 and 3-year aged solar reflectance of 0.15;
2013 California Building Energy Efficiency Standards,Title 24,Part 6
requirements;rated by the Cool Roof Rating Council(CRRC).
See actual warranty for complete details,limitations,and requirements
2018 Roofing Brand Awareness Study by Owens Corning Roofing and Asphalt,LLC.
t Owens Corning Roofing strives to accurately reproduce photographs of shingles.Due to manufacturing variances,the limitations of the printing process,and the variations in natural
lighting,actual shingle colors and granule blends may vary from the photo.The pitch of your roof can also impact how a shingle looks on your home.We suggest that you view a
roofing display or several shingles to get a better idea of the actual color.To accurately judge your shingle and color choice,we recommend that you view it on an actual roof with
a pitch similar to your own roof prior to making your final selection.Color availability subject to change without notice.Ask your professional roofing contractor for samples of colors
available in your area
+The amount of Triple Layer Protection'may vary on shingle-to-shingle basis.
#Tru-Bond`is a proprietary premium weathering-grade asphalt sealant that is blended by Owens Corning Roofing and Asphalt,LLC.
##40-Year Limited Warranty on commercial projects.
Owens Corning Roofing Preferred Contractors are independent contractors and are not an affiliate of Owens Corning Roofing and Asphalt,LLC,or its affiliated companies
For patent information,please visit www.owenscorning.com/patents
SureNair Technology is not a guarantee of performance in all weather conditions
SureNair Technology is available only on Owens Corning'Duration'Series Shingles.
ENERGY STAR and the ENERGY STAR mark are registered trademarks of the U.S.Environmental Protection Agency.
#International Code Council Evaluation Services Acceptance Criteria for Alternative Asphalt Shingles.
A Excludes non-Owens Coming'roofing products,such as flashing,fasteners,pipe boots,and wood decking.
NEMO Ietc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Owens Corning Evaluation Report 037940.02.12-1111
One Owens Corning Parkway FL10674-R16
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by: °""'"•_
'77s=f:.. The facsimile seal appearing was authorized by Robert
Robert J.M. Nieminen,P.E.
p` y, Nieminen,P.E.on 12/11/2020.This does not serve as an
Florida Registration No.59166,Florida DC4ANE1983 ", '��.r.°.y;`a'' electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018 NEMO ETC,LLC
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 71 Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
STANDARDS:2.
Section Propeft Standard Year
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5,R905.2.4 Material standard ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2019
3. REFERENCES:
Knftz Examination Reference Date
Owens Corning Declaration Equivalency Declaration 08/06/2019
PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
PRI(QUA9110) Quality Control Service Confirmation 04/05/2020
PRI(QUA9110) Quality Control Florida BCIS Current
PRODUCT4. DESCRIPTION:
TABLE 1:ASPHALT SHINGLE COMPONENTS
Type Product Plant(s) Material Description
Standard
Starter Strip Shingle H-TX,OR
Accessory Starter Strip Plus MN,OR ASTM D3462 starter strips for asphalt roof shingles
Starter SRS TopShield Starter MN,OR
Strips Starter Shingle Roll NH ASTM D1970 mineral-surfaced,fiberglass-reinforced,
self-adhering SBS modified bitumen starter
Supreme GA,CA,CO,I-TX,NJ,OH, ASTM D3462 fiberglass reinforced 3-tab asphalt
TN,OR,IL roof shingles
Berkshire' MN ASTM D3462 fiberglass reinforced,4-tab asphalt
roof shingles
Duration Premium CA,OR
Aspalt Duration'Premium COOL CA
Shingles les TruDefinition'Duration'
g IN,CA,CO,I-TX,FL,NJ,OH,
TruDefinition Duration' MN,OR,GA,IL,TN fiberglass reinforced,laminated
Designer Color Collection ASTM D3462
GA,IN,CA,CO,H-TX,I-TX, asphalt roof shingles
Oakridge FL,NJ OH,TN
TruDefinition'Oakridge H-TX,I-TX
WeatherGuard'HP TN
NEMO ETC,LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 2 of 10
ONEMO I etc.
TABLE 1:ASPHALT SHINGLE COMPONENTS
Type Product Plant Materials) Standard Description
Berkshire'Hip and Ridge MN
Shingles with Sealant
Hip and DuraRidge°Hip and Ridge MN fiberglass reinforced,hip and ridge
Ridge Shingles with Sealant ASTM D3462 asphalt roof shingles
Shingles ProEdge° I GA,CA,OH,OR
WeatherGuard'HP Hip and TN
Ridge Shingles
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
)
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications
TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES
Product FBC Table 1507.2.7.1 or R905.2.6.1
Supreme
Berkshire'
Duration'Premium
Duration Premium COOL
TruDefinition'Duration ASTM D3161(F)&ASTM D7158(H)
TruDefinition'Duration Designer Color Collection
Oakridge'
TruDefinition'Oakridge'
WeatherGuard'HP
5.5.1 Classification by ASTM D7158:
ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO ETC,LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization#32455 7i"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 3 of 10
ONEMO I etc.
TABLE 213:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE
Type Product FBC Table 1507.2.7.1 or R905.2.6.1
Starter Strip Shingle
Starter Strips Starter Strip Plus ASTM D3161,Class F
SRS TopShield Starter
Berkshire'Hip and Ridge Shingles with Sealant
Hip&Ridge DuraRidge•Hip and Ridge Shingles with Sealant
Shingles ProEdge® ASTM D3161,Class F
WeatherGuard'HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 611320-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
INSTALLATION:6.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions,using minimum five(5)nails per strip.
Feltwrdodaymart --Deck Paf Duk WWI
Self-adhered radDrlaymDrn
wathwLocN
w+derfarment '�
Drip edge
Drip Drip edge � i
ala6 bated
Nails located r-r tram eave
2"-3"from eave
Install first Salt-sealing adhesive save
hsta�first Sirtr strip P4a n9 adhee
Starter Strip positioned along eave with 6-rived 1 Pad a1o"g eavD
shingle with
6"removed Starter Strip sh' overhangs eave and rakes W-%- stanar p Pks overhang,Dawn card rakes 1/4^-314'
Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus
NEMO ETC,LLC Evaluation Report 037940.02.12-1131
Certificate oJAuthorization#32455 7r"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 4 of 10
ONEMOjetc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Underayment
Drip edge
Drip edge
Starter Shingle Roll adhered
- directly to underlayment and
primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3:Starter Shingle Roll
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Berkshire'shingles require minimum five(5)nails per shingle.
➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
gzam
Normal Mansard or Arse pare Normal Mansard or Area pars
Wind Areas High Wind dosvanes y Wind Areas High Wind desvanes y
Area porn vientos normaies Areas vientos fuertes Area pars vientos normsias Areas vientos fuertes
1r--;t;2 12 t2t
7 Exposure 5 5/8•Exposure
Exposicion Exposicidn
Figure 4:Minimum Nailing,Supreme Figure 5:Minimum Nailing,Supreme
(Standard Size) (Metric Size)
NEMO ETC,LLC Evaluation Report 037940.02.12-Rll
Certi/icateof Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 5 of 10
ONEMO etc.
6.3.1.2 Berkshire®:
Sealant strip Sealant strip
La lira de selladar ! La tirade sellador
8 V2" 9 Y2" 9 Y2 8 VP <--
8'@"' 8'h" 8'2'
1'
Figure 6: S-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire
Sealant strip
La tira de 5e7lador
04- • •4----------•4- r•
r -
2 Asphalt roofing cement
Cemento de lecho de astatto
Figure 8: Mansard or Steep Slope Pattern,Berkshire
NEMO ETC,LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 6 of 10
NNEMOjetc.
6.3.1.3 Duratton® Premium, Tr D fni ion® Duration, Duration® Premium COOL & TruDefinition" Duration` Designer Color
Collection:
4-Nail Fastening Pattern
SureNaiM fastening area width
Nail,Typical
1" 12" 12" 1"
00+C..x.0 D.,~ 4 •
6-1/8" 5 518"
r=pos..e
Figure 9:Standard 4-Nail Pattern,Duration
6-Nail Fastening Pattern
SureNailO fastening area width
Nall,Typical
1" 12"
aeo corr:.0—s�•�i e".,wo+w.o i`a.res co�us�errbs---i
6-1/8" 5.5/8"
r.�.r1 F
Figure 10: 6-Nail Pattern,Duration
Fastening for Slopes Greater Than 21:12
SureNailO fastening area width
Nail,Typical
1" 12" 12" 1"
gem coming wreNai • !:a�an+s aawo�cww •oen.comma svef+�z •
6-1/6" 5-518"
e=oosue
Four 1"Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern,Duration
NEMO ETC,LLC Evaluation Report 037940.02.12-Rll
Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 7 of 10
ONEMO I etc.
6.3.1.4 TruDefinition"Oakridge®,Oakridge®:
4 Nail pattern 6 Nail Pattern
Esquerna con 4 clavos Esauerna con b clavos
V 1.
12- 12"—�►I L
72..---�
5 5/8"Exposure Nails 5 5/8"Exposure Nails
Exposirdoa de 5 5/S putg. clavos Exposicioa de 5 5/S pulp. Expo"Exposure Claws 5 5p8"Exposure
Erposicidn de 5 5/8 ping. Exposieidn de 5 5/8 pufg.
Figure 12:Standard 4-Nail Pattern,Oakridge Figure 13:6-Nail Pattern,Oakridge
Fastening for Slopes Greater Than 21:12
SureNaim fastening area width
Nall'Typical
1" 12" 12" 1"
a�neanngsa i .xm o�,o�.�o •e,.em c«w.vs�a� •
6.118"
ew"s�
2"
Four 1"Spots of Asphalt Roofing Cement
Figure 14:Mansard or Steep-Slope Pattern,Oakridge
6.3.1.5 WeatherGuard®HP:
6 Nail Pattern
Esquema con 6 clavos Nail 6 1;8" from bottom
of shirge
Clave a 6 1:8 pulp.de la
5 5T Exposure g Fasteners r pie inferior de la t0a
Exposicion de 5 51 pufg. )et
1rt 12" 12' 1"
9' 12 plfg. 12 4.!III
1y� 1 al;
� • 'lag • • • • 7pg • —
!kA cum _
Four 1' Spots of Asphalt Roof Cement
5 5iS't:,tposue 5 de 5 Ex maatre Cuatro puntos de cemetto de tedro de asfalto de 1 pulgada
Fxpasabn de 5 5$ping. Expasici6i de 5 5� ping.
Figure 15:6-Nail Pattern,WeatherGuard HP Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP
NEMO ETC,LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 8 of 10
6.4 HIP AND RIDGE SHINGLES: ONEMOjetc.
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two(2)nails per shingle.
➢ WeatherGuard*HP Hip and Ridge Shingles and ProEdge®require minimum four(4)nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire®Hip and Ridge with Sealant and DuraRidge®Hip and Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction Fig. B Top View
�— Direccion del viento predominante Vista superior
1" 1"
Nail
A 2 11 vo
Nails Owens Coming SureNatli�'
Clavos
� I I
i I I
I I I I clb
� W CIO
yl N
I
A
12"
Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge
6.4.1.2 WeatherGuard®HP Hip and Ridge Shingles:
Fig.A 44 Fig.C Hip&Ridge Shingle Fastening
Prevalling Wind2i�L Top View
Direction A
A
Nails 4 4
I
A I Nails Nails
A I I
I I T'
I I 2^ 2"
I �^ V.
I I
AA i i I I ��
I I I I 1" ' I
Exposure
\ S Exposure
12
Figure 19:Isometric View,WeatherGuard HP Hip and Ridge Figure 20:Plan View,WeatherGuard HP Hip and Ridge
NEMO ETC,LLC Evaluation Report 037940.02.12-Rll
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 9 of 10
NNEMOjetc.
6.4.1.3 ProEdge®:
Prevailing Standard 11"
Wind Direction Fastening
Sealant Strip Pattern
6'Exposure 2'
12' I Sealant
I r
Fasten 71h 7/' 6'Exposure
Cover Exposed
Fasteners with i
Roof Cement
Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson(@pricmt.com
- END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization#32455 7T'EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 10 of 10