Loading...
HomeMy WebLinkAboutPlummer Porch Addition PlansPRODUCT OPENING DESIGN PRODUCT MANUFACTURER MODEL # APPROVAL # GLASS ATTACHMENT METHOD PRESSURES (WORST DESIGN TYPE CASE) PRESSURES ROOFING ZONE 1 -39.1 -82.5 GAF EVERGUARD FL3445.1 N/A ONE OR MORE LAYERS TREAD SAFE INSULATION ZONE 2 -51.8 THERMOPLASTIC FASTEN WITH DRILL-TEC # 14 WITH 1" EMBEDMENT @ ZONE 3 -66.5 ROOF SYSTEMS 18" AND 24 O.C. EVERGUARD PVC: XK OR EVERGUARD PVC SMOOTH INDUCTION WELDED TO DRILL-TEC RHINO BOND PVC XHD PLATES OR DRILL-TEC RHINOBOND PVC XHD TREAD SAFE PLATES THE SEAL HEREON IS PROVIDED ONLY IU INDICAI t OUR REVIEW AND APPROVAL FUK UDt Ur rKUUUk-IJ uQ�I ru rkJK I HISS I KUCI UKt. I M AIL LtrIANl.t ur in rar rnuuuLia Arvu ivir i nuu., ur ATTACHMENT ARE BASED ENTIRELY UPON TEST DATA PROVIDED BY THE MANUFACTURER, WHICH CARRIES ITS OWN ENGINEER'S CERTIFICATION AND IMPLIES NO WARRANTY OR GUARANTEE BY THIS OFFICE FOR THESE PRODUCTS. ROOF HEATHING NAILIN9 ZONE INFO. ZONE P1 REMAINING AREA W/8d RING SHANK @ 6" O.0 PERIMETER & 6" O.C. FIELD ZONE P2 4` X LENGTH W/8d RING SHANK @ 4" O.0 PERIMETER & 6" O.C. FIELD, ZONE P3 5' X 5' @ HIP AND 5' X LENGTH @ GABLE ENDS W/8d RING SHANK @ 4" O,C PERIMETER & 4" O.C, FIELD . NOTES.: 19/32" CDX PLYWOOD SHEATHING 25' - 0" OR GREATER MEAN ROOF HEIGHT SHALL HAVE 10 d RINGSHANK NAILS. UNDERLAYMENT FELT .SHALL. BE PEEL,&.STICK OR.30# FELT.COMP.LYING W/ ASTM-D226. 44 A �s, ; �fiti�.., ta'.r�n,lj .�, ,,.,^•• ,�L_g�..��° ='.v+�(--C__ �vEYt��.l� J,. CFO. T(O IJ 411 f�� Cof Imo,. -Z- (FOUNDATION SCHEDULE S-1 4" (3000 PSI ) POURED CONCRETE SLAB WITH FIBERMESH REINFORCING ON .006" VAPOR BARRIER OVER CLEAN COMPACTED TREATED FILL. F-1 12" X 12" THICKENED EDGE WITH 1 # 5 BAR CONTINUOUS. F-2 16" DEEP X 18" WIDE MONOLITHIC FOOTING WITH 3 # 5 BARS CONTINUOUS, D-1 3 # 5 DOWELS DRILLED 6" MIN. INTO EXISTING FOUNDATION SET IN EPCXY AND TIED TO NEW FOOTING STEEL. D-2 # 5 DOWELS DRILLED 6" MIN. INTO EXISITING FOUNDATION SET IN EPDXY @ 48" O.C. TIED TO NEW FOOTING STEEL. NOTE: REMOVE EXISTING PATIO SLAB AS REQUIRED FOR NEW FOUNDATION Q t STRUCTIJRA Nam4TE5, 1. STRUCTURAL LUMBER TO BE HEM -FIR #2 GRADE OR BETTER WITH 1000 P.S.I. MIN. FIBER STRESS VALUE. 2. CONCRETE TO BE 3000 P.S.I. MIN. FOR BEAMS, COLUMNS, AND FILLED CELLS, CONCRETE SLABS AND FOOTINGS TO 2500 P.8,1. MIN, 3. REINFORCING STEEL SHALL BE GRADE 60 OR BETER WITH 30' MIN. LAP. 4. CONCRETE COVER OVER REINFORCING STEEL: FOOTINGS 3" BEAMS COLUMNS 5. FILL (SOIL) SHALL. BE PLACED IN LIFTS NOT TO EXCEED 12" AND COMPACTED TO A MINIMUM OF 95% MODIFIED PROCTOR DENSITY. 6. ALL COMPONENTS OF THIS STRUCTURE HAVE SEEN DESIGNED AND SELECTED TO WITHSTAND WIND FORCES PER THE FLORIDA BUILDING CODE 2020 EDITION. 7. DOOR AN WINDOW ASSEMBLY COMPONENTS TO BE CERTIFIED BY MANUFACTURER FOR WIND FORCES PER THE FLORIDA BUILDING CODE 2020 EDITION PER WIND LOAD COMPLIANCE DESIGN PRESSURES. 8, PRECAST/PRESTRESSED CONCRETE LINTELS TO HAVE 4" MINIMUM BEARING, SEE LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. 9. MORTAR FOR MASONRY CONSTRUCTION SHALL CONFORM TO ARTICLES 2.1 AND 2.6 A OF TMS 602/ACI 530.0/ASCE6 10. FOR METHOD OF ATTACHMENT OF DOORS AND WINDOWS, SEE ATTACHED PRODUCT REVIEW AFFIDAVIT. 11. ALL LUMBER IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED PER SECTION 2303.1.9.1 OF THE FLORIDA BUILDING CODE. "NOTE: ALL SIMPSON STRONG -TIE PRODUCTS IN CONTACT WITH TREATED LUMBER SHALL HAVE A MINIMUM Z-MAX COATING OR BETTER. NOTE: STUCCO ON RIBLATH OR PAPER BACKED WIRE LATH SHALL BE ATTACHED TO HORIZONTAL FRAMING AS PER ASTM C-1063: LATH SHALL BE ATTACHED TO FRAMING MEMBERS WITH CORROSIONRESISTANT MATERIALS. ATTACHMENTS SHALL BE SPACED NOT MORE THAN 6" O.C. ALONG SUPPORTS, FASTENERS TO BE USED CAN BE 6D COMMON OR ROOFING NAILS HAVING A MIN. 1-3/4" PENETRATION INTO HORIZONTAL FRAMING MEMBERS OR STAPLES W! A MIN. %" CROWN ENGAGED NOT LESS THAN (3) STRANDS OR LATH AND MUST PENETRATE THE WOOD FRAMING MEMBERS %" MIN. x 2a e r a ter^. lt� 1 A' s� CTci A iG (? 7-44 O' cr r-, ^.Y-' Ce Ar T T- Certifioation for Cle i L csa t Compliance 1. DESIGN CODE: Florida : F o a.M(code 2020 Edition w/20 ,� -, supplements using ASCE 7-16 2. Structure Design is: _ _ Enclosed _ }e' Partially Enclosed Open Suiiding 3. Risl(Category: ____t ?s it -III ____.IV Exposure Category: 7"-B r,,,C _D Adjustment coefficient 1,0 4. Design Wind Velocity )&Omph _ASD _;LRFD End Zane Width ft. 5. Mean Roof Height: ­5'-ft. Roof Pitch: I / 4:12 Parapet __-__ft, 6. Components 8 Cladding Design Pressure used: (PSF, based on Actual sq. ft. @ 'bra MRH (worst case) Zone 1:-37 s t ,Zone 2:-�- - ,,� Zone 3:-44 15Zone 4:- 1$'1 Zone 5:3A, 5 Garage: ti?/'A. 7. Design Loads: Floor: ? E PSF Roof/Dead: ( S PSF Roof/Live PSF Balcony: _PSF Dock -PSF Deck: _ PSF Stairs: � PSF Fence: - - ___ _ _ P PSF Railing: SF 8. Were Shear Walls Considered for Structure? X Yes _Not Applicable Explain Why Not: 9. Is a Continuous Load Path provided? Yes ___-_Not applicable Explain Why Not: 10. Minimum soil bearing pressure 2000 P.S.F. F"A. t2�A I Pf � I ARCHITECT Arch itiveocitionic Inc 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 WWW.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2020 PROJECT PLUMMMER PORCH ADDITION ST. LUCIE COUNTY, FLORIDA CLIENT CONSULTANTS �ECSIvr- -1D 110 � ? mini+ REGISTRATION J,£' MICHAEL J. SEAL, AIA AR96898 NO. DATE REVISION SHEE I I ITLE / SHEET NUMBER zK4C 4 PROJECT NUMBER DATE fy?3 13-- Y