HomeMy WebLinkAboutAPPROVED, Philip Beekman MTS NOA10/22/21, 9:40 AM
Florida Building Code Online
BCIS Home Log In User Registration s Hot Topics Submit Surcharge ! Stats &Facts Publications Contact Us BCIS Site Map Links 1 Search
Firarida
Product Approval
-USER: Public User
Product Approval Menu > Product or Application Search > $p_pj cation List > AppiIcaNan Datail
FL #
FL5259-R34
Application Type
Revision
Code Version
2020
Application Status
Pending FBC Approval
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email lilt West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R34 COI 2021 01 COI NIEMINEN p�df
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4798
2011
ASTM D6163
2015
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2015
+.++..n•tin,..;,a.,ti,.:�.r.,...,...�..�f.,. 4+1--.,+rf.,,,i,c.,An7n'lrrlr'h,Co%7fnnnlinnnn\A(o/ 9hW lt/7CrRXl rin()RKAv6.n01.'Ari0WAr1 119
10/22/21, 9:40 AM Florida Building Code Online
FM 4474
FRSA/TRI, Sixth Edition
TAS 103
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2021
Date Validated 10/18/2021
Date Pending FBC Approval 10/20/2021
Summary of products
2011
2018
2020
2015
FL #
Model, Humber or Flame
Description
5259.1
Polyglass Roof Underlayments
Polyglass roof underlayments for use in FBC HVHZ jurisdictions.
(HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5259 R34 II 2021 10 15 FINAL ER PLYG UNDERLAYMENTS FL5259-
R34 HVHZ _pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL5259 R34 AE 2021 10 15 FINAL ER PLYG UNDERLAYMENTS FL5259-
R34 (HVHZ),pdf
Created by Independent Third Party: Yes
5259.2
Polyglass Roof Underlayments
Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions.
(non-HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R34 II 2021 10 15 FINAL ER PLYG UNDERLAYMENTS FL5259-
R 4 NON-HVHZ)spdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular underiayment system for
FL5259 R34 AE 2021 10 15 FINAL ER PLYG UNDERLAYMENTS FL5259-
R34 NON-HVHZ)spdf
use in tile roof systems. Refer to ER Section 5.8 for
other systems and associated maximum design
Created by Independent Third Party: Yes
pressures. 2.) Refer to ER Section 5 for other limits
of use.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 8$0-487-1824
The State of Florida is an AA/EEO employer. goyLiaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, ES., please dick here .
Product Approval Accepts:
a_Im
Credit Card
.safe
Polyglass USA, Inc. Evaluation Report P12060.02.09-1130
1111 West Newport Center Drive FI.5259-1134 (NON-HVHZ)
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1330 Revision 30: 10/15/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the Ph Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments, for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by:
R�, „�I,,,,,. ---
RRJ V. r -
J
Robert J.M. Nieminen P.E.
Florida Registration No. 59166, Florida DC4ANE1983
''>„fin i'�y`'��� � The facsimile seal appearing was authorized by Robert Nieminen, P.E. on
10/15/2021. This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC, LLC
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 71 Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
1504.3.1
1504.3.1
1507.1.1 / R905.1.1
1507.1.1, 1507.2.4, 1507.2.9.2 /
R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
1507.11.2 / R905.11.2
1507.11.2 / R905.11.2
1507.11.2 / R905.11.2
1507.11.2 i R905.11.2
TAS 110
Property
Wind resistance
Wind resistance
Material standard
Material standard
Material standard
Material standard
Material standard
Material standard
Material standard
Accelerated Weathering
Standard
FM 4474
UL 1897
ASTM D226
ASTM D1970
FRSA/TRI, Sixth Edition
ASTM D6163
ASTM D6164
ASTM D6222
ASTM D6509
ASTM D4798
Year
2011
2015
2009
2015
2018
2015
2011
2011
2015
2011
Ent!
Examination
Reference Date
End
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1 4/25/2001
ERD (TST 6049)
FRSA/TRI (tile slippage)
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Wind Uplift
11757.08.01-1 8/13/2001
ERD (TST 6049)
MAIM (tile slippage)
PLYG-SC12115.08.17
8/8/2017
ERD (TST 6049)
Wind Uplift
11776.06.02 1/16/2003
ERD (TST 6049)
FRSA/TRI
PLYG-SC13035.08.17
10/31/2017
ERD (TST 6049)
Wind Uplift
P1740.01.07 1/4/2007
FM (TST 1867)
Wind Uplift
FM 3004091
1/12/2000
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2 2/5/2007
NEMO (TST 6049)
ASTM D1970
4-PLYG-18.004.03.18
3/29/2018
ERD (TST 6049)
Wind Uplift
P9260.03.08 3/21/2008
NEMO (TST 6049)
ASTM D1623, TAS 203
4S-ICP-18-001.07.18-R1
7/23/2D18
ERD (TST 6049)
Wind Uplift
P30540.11.09-111 11/23/2009
MEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
1/11/2019
ERD (TST 6049)
ASTM D1623, TAS 103
P11030.11.09-1 11/30/2009
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A
1/24/2019
ERD (TST 6049)
TAS 117(B),TAS 114(C)
P11030.11.09-2 11/30/2009
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19-C
5/20/2019
ERD (TST 6049)
ASTM D4977
P11030.11.09-3 11/30/2009
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-W4.10.19-G
10/8/2019
ERD (TST 6049)
ASTM D1970
P33360.06.10 6/25/2010
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.10.19-1
10/8/2019
ERD (TST 6049)
FRSA/TRI
P33370.03.11 3/2/2011
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.10.19-L
10/9/2019
ERD (TST 6049)
ASTM D1623, TAS 103
P33370.04.11 4/26/2011
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.12.19-F
12/18/2019
ERD (TST 6049)
ASTM 01970, D4798
P37300.10.11 10/19/2011
NEMO (TST 6049)
FRSA/TRI
4i-PLYG-19-S5UDL-02.A
1/2/2020
ERD (TST 6049)
FRSA/TRI
P40390.08.12-1 8/6/2012
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.12.19-K-Rl
1/7/2020
ERD (TST 6049)
ASTM D1623, TAS 103
P40390.08.12-2 8/7/2012
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.01.20.H
1/14/2020
ERD (TST 6049)
ASTM D1623, TAS 103
C41420A9.12-3 9/11/2012
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.01.20.K
1/14/2020
ERD (TST 6049)
ASTM D6509
P37590.03.13-1-111 2/5/2013
NEMO (TST 6049)
FRSAJTRI (tile slippage)
4S-PLYG-18-004.01.20.A
1/16/2020
ERD (TST 6049)
TAS 114(J)
P39680.03.13 3/4/2013
NEMO (TST 6049)
ASTM D6164
4S-PLYG-18-004.01.20.B
1/16/2020
ERD (TST 6049)
ASTM D6164
P37590.03.13-3A 3/6/2013
NEMO (TST 6049)
FRSA/TRI
PLYG-SC15855.05.20.A
5/29/2020
ERD (TST 6049)
ASTM D6164
P37590.07.13-1 7/2/2013
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-01
7/6/2020
ERD (TST 6049)
Wind Uplift
P41630.08.13 8/6/2013
NEMO (TST 6049)
ASTM D6222
4q-PLYG-I9-SSMBB-05.A
7/23/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13 9/4/2013
NEMO (TST 6049)
ASTM D4798, D1623
4j-PLYG-I9-SSUDL-05.A
9/10/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13 9/4/2013
NEMO (TST 6049)
ASTM 01970
4j-PLYG-20-SSUDL-05.A
9/30/2020
ERD (TST 6049)
ASTM D1970 (adhesion)
P45370.09.13 9/18/2013
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-S5UDL-05.0
9/30/2020
ERD (TST 6049)
Wind Uplift
P11751.05.03-R1 11/26/2013
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-11.A
10/21/2020
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1 11/26/2013
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.12.19.D
10/27/2020
ERD (TST 6049)
ASTM D1623, TAS 103
P45270.05.14 5/12/2014
NEMO (TST 6049)
FRSA/TRl
4j-PLYG-I9-SSUDL-01.A
11/18/2020
ERD (TST 6049)
ASTM D1623, TAS 103
6020.09.14-5 9/8/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-I0-20-SSLAP-01.A
12/15/2020
ERD (TST 6049)
ASTM D1623, TAS 103
6020.09.14-6 9/8/2014
NEMO (TST 6049)
ASTM D4798, D1623
4j-PLYG-20-SSUDL-13.A
03/02/2021
ERD (TST 6049)
ASTM D1623
P46520.10.14 10/3/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-SSUDL-03.A
03/04/2021
ERD (TST 6049)
FRSA/TRI
P44360.10.14-111 10/7/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4j-PLYG-20-SSUDL-07.A
04/07/2021
NEMO ETC, U.C.
Evaluation Report P12060.02.09-R30
Certificate ojAuthorization #32455
7- EDITION (2020) F8C NON-HVHZ
EVALUATION
FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments
Revision 30:10/15/2021
Page 2 of 17
—
ONEMOjetc.
Entity Examination Reference Date Entity Examination Reference Date
3/2018
.~,^..~' .~~.~ '.~.^~^~^~~. ~^''^~. .^~~—~^° Quality Control Service _Confirmation -- _,--__
om(TST 6049) mmm PLYa-SC12025.10.16 10/12/2016|mNuA9625> Quality Control Service Confirmation (TX) 11/07/2019
UL (QUA9625) Quality Control Florida BCIS Current
Product Material Standard Plant(s) Description
4.1 Elastobase V (formerly ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet
4.3 Elastoflex S6 G ASTM D6164 FL, PA Polyester -reinforced, SBS modified bitumen cap sheet
4.4 Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet
4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
4.6 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI09-18 waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
4.7 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet
4.8 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet
4.9 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRl Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
4.10 Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRl 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRl Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
4.11 Polyflex SA P ASTM D6222 FL,TX Polyester -reinforced, APP modified bitumen cap sheet
4.12 Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet
4.13 Polybase V fformerly "Polyglass ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet
4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet
NEMOETC, uc Evaluation Report ��.02.09-R30
Certificate afAvmvmotionxs45s r-EDITION (2nzu) pocmomxxxzEVALUATION ru259-n34 (Nom*voZ
Polyglass Roof unuenavmewm Revision 3u'uV1$aoz
Page amz7
ONEMOletc.
4.15 Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
4.16 Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 PA, TX membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
4.17 Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane with a 190 g/m2 polyester fabric surface
4.18 Polystick TU P FRSA/TRI 09-18 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
4.19 Polystick TU Plus ASTM D1970 FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane, glass fiber reinforced, with a polyester fabric
surface
4.20 Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane, glass fiber reinforced, surfaced with a
textured film surface
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1130
Certificate o/Authorization N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30: 10/15/2021
Page 4 of 17
y
1
•
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBCSecVon:
1507.2
1507.3
1507.4 and 1507.5
1507.7
1507.E and 1507.9
Asphalt
Clay and Concrete Tile
Slate or Slate-
Underlayment
Metal
Wood
Mechanical Attach
Adhesive -Set
Shingles
Type Shingles
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase V
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
D226, Type 11)
See 5.8.3)
See 5.8.3)
D226, Type II)
D226, Type 11)
D226, Type 11)
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
D226, Type II)
See 5.8.3)
See 5.8.3)
D226, Type 11)
D226, Type 11)
D226, Type 11)
Yes
Yes
Polybase V
No
(as Base Sheet,
(as Base Sheet,
No
No
No
See S.8.3)
See 5.8.3)
Yes
Yes
Polyglass G2 Base
No
(as Base Sheet,
(as Base Sheet,
No
No
No
See 5.8.3)
See 5.8.3)
Elastoflex S6 G
No
Yes
Yes
No
No
No
(See 5.6.1)
Elastoflex S6 G FR
No
Yes
No
No
No
No
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
Yes
Yes
(joint strips, 1507.1.1.3
(See 5.6.1)
J 11905.1.1.3)
Mule -Hide SA-APP Cap Sheet
No
Yes
Yes
No
No
No
(See 5.6.1)
Mule -Hide SA-APP Cap Sheet (FR)
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex SA P FR
No
Yes
Yes
No
No
No
(See 5.6.1)
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
(jointstrips, 1507.1.1.3
J R905.1.1.3)
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
(Joint strips,1507.1.1.3
/ R905.1.1.3)
Yes
Yes
Polystick TU Max
No
Yes
(See 5.6.1)
Yes
No
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Yes
Yes
Polystick TU P
No
Yes
No
No
(joint strips,1507.1.1.3
(See 5.6.1)
J R905.1.1.3)
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes
Yes
(Joint strips,1507.1.1.3
(See 5.6.1)
/ R905.1.1.3)
Yes
Polystick XFR
Yes
Yes
No
Yes
Yes
(joint strips,1507.1.1.3
/ R905.1.1.3)
MEMO ETC, LLC. Evaluation Report P12060.02.09-R30
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30:10115/2021
Page 5 of 17
ONEMOjetc.
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOwABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
Polystick TU Max, Polystick TU P or Polystick TU Plus
DAP Foam `Touch 'n Seal
StormBond Roof Tile Adhesive"
PolystickTU P
DAP Foam'Touch'n Seal
FL14506
StormBond 2 Roof Tile Adhesive"
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick
Dupont "rile Bond' Roof Tile
FL22525
TU Plus
Adhesive"
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset® AH-160"
FL6332
Polystick TU P or Polystick TU Plus
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset® ftTA-1"
FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type
Primer
Materials)
HydraGuard Dual Pro,
Deck /
(Optional) ASTM
plywood, OSB, Southern Yellow Pine or Huber Engineered
"ZIP
HydraGuard Tile Pro, Polystick IR
sheathing
D41
Woods System" Panels
ASTM D41
structural concrete
Xe, Polystick MTS Plus, Polystick
ASTM C1289 Type II Class 1 polyisocyanurate, ASTM
TU Max, PolystickTU P, Polystick
self-
TU Plus, Polystick XFR, Mule -Hide
adhering
Insulation
{Optional) ASTM
C1289 Type V polyisocyanurate-composite, DensDeck
SA-APP Cap Sheet, Mule -Hide SA-
D41 or WB-3000
Prime or SECUROCK Gypsum -Fiber Roof Board
APP Cap Sheet (FR), Polyflex SA P
ASTM D226, Type 11 felt, Elastobase V, Elastobase P or
or Polyflex SA P FR
Base Sheet
N/A
Mule -Hide Nail Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Elastoflex S6 G or Elastoflex S6 G
FR
hot asphalt
D41
Base Sheet
N/A
ASTM D226, Type 11 felt, Elastobase V, Elastobase P, Mule -
Hide Nail Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
torch-
Polyflex G or Polyflex G FR
applied
D41
Base Sheet
N/A
Elastobase V, Elastobase P, Mule -Hide Nail Base, Polyglass
G2 Base or Polybase V
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC, U.C. Evaluation Report P12060.02.09-R30
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30: 10/15/2021
Page 6 of 17
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —
for mechanically attached base sheets - not less than:
0 FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
® Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure = -97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100orASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x I%" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R30
Certificate ojAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polygiass Roof Underlayments Revision 30: 10/15/2021
Page 7 of 17
#5 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure = -165 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: None
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#7 Maximum Design Pressure = -202.5 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) PG100 at 0.5 gal/square
Base Ply: Polystick MTS Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga, x 1Y"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#8 Maximum Design Pressure = -255 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: PG100 at 0.5 gal/square.
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x IN"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#9 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#10 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#11 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florido High
Wind Concrete and Clay Roof Tile Instollotion Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
NEMO ETC, I.I.C.
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-1130
FL5259-R34 (NON-HVHZ)
Revision 30: 10/15/2021
Page 8 of 17
ONEMOletc.
#12 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP-Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#13 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#14 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type it felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#15 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#16 Maximum Design Pressure = -45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#17 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#18 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
MEMO ETC, U.C. Evaluation Report P12060.02.09-R30
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30:10/15/2021
Page 9 of 17
ONEMOletc.
#18 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#20 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface) _
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#22 Maximum Design Pressure = -52.5 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex Original Cap Nails
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#23 Maximum Design Pressure = -60 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#24 Maximum Design Pressure = -60 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing:
12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#25 Maximum Design Pressure = -60.0 psf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
MEMO ETC, I.I.C. Evaluation Report P12060.02.09-R30
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30:10/15/2021
Page 10 of 17
#26 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#27 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#28 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polybase V (requires use of torch -applied Underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#29 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#30 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#31 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#32 Maximum Design Pressure = -75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polybase V (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1130
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Undertayments Revision 30: 10/15/2021
Page 11 of 17
ONEMOletc.
#33 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#34 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#35 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#36 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polybase V (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#37 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#38 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#39 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1130
Certffcate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30:10/15/2021
Page 12 of 27
ONEMOletc.
#40 Maximum Design Pressure = -97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#41 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#42 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#43 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#44 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#45 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R30
Certificate of Authorization #32455 r" EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polygiass Roof Underiayments Revision 30: 10/15/2022
Page 13 of 17
ONEMOletc.
#46 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#47 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#48
Maximum Design Pressure = -112.5 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer at all tin -caps
Base Ply:
Polystick MTS Plus, self -adhered
Underlayment:
Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#49
Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase V (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#50
Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase V (sanded top surface)
Fasteners:
Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt.
#51
Maximum Design Pressure = -127.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Elastobase V or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing:
9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#52
Maximum Design Pressure = -127.5 psf:
Deck:
APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Elastobase V (sand top surface)
Fasteners:
TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing:
9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment:
Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C.
Evaluation Report P12060.02.09-1130
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON.HVHZ)
Polyglass Roof Underlayments Revision 30: 10/15/2021
Page 14 of 17
u�NEMO etc.
#53 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase V, Elastobase P, Polyglass G2 Base or Polybase V
Mechanically attached
30
Polystick IR-Xe
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table 1)
180
Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
Adhesive -set tile roof system
180
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -HECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope';
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
HydraGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1130
Certificate ojAuthorization ✓F32455 7"- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVHZ)
Polyglass Roof Underlayments Revision 30:10/15/2021
Page 15 of 17
ONEMOletc.
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase V, Elastobase P or mule -Hide Pail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase V, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied.
Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
6.3.2.1 Elastobase V (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase V (sanded -top) and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the
"TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed
by Elastoflex S6 G, Elastoflex 56 G FR Or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or
Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in
Table 1.
• When Elastobase V (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex
S6 G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table
1 or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase V (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR,
refer to Section 5.8.3.2 herein for attachment requirements.
[;Y-11
6.4.1 General:
All seal -lap seams (selvage laps) must be firmly roiled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non -Tile Applications:
MEMO ETC, U.C. Evaluation Report P12060.02.09-1130
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R34 (NON-HVH2)
Polyglass Roof Undedayments Revision 30:10/15/2021
Page 16 of 17
ONEMOjetc.
Shall be installed in compliance with requirements for an approved self -adhering undedayment (ASTM D1970) in F&C
1S071'1.1or15V7'1.1'3orFBCResidential R9o5.1.1.1orR905.2.1.3for the type ufprepared roof covering tobeinstalled,
and the manufacturer's installation instructions. -
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type 11 felt, Elastobase V, Elastobase P
or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.] Tile Applications (excludes HydraGuard Dual Pro and Polystick IR-Xe):
Shall be installed incompliance with the requirements for Self -Adhered Membrane set forth in FROA/[R| Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer *aSection 5.O.3herein for attachment limitations.
Refer toTable 4herein for tile staging limitations.
6.4.4 Multi -Ply UnderlaVment Systems:
Polystick M73 Plus or Po|ystickXFRfollowed by HydmGuund Tile Pro, Po|yOex5A P, Polysdck MTS Plus, PolystickTU Max,
Po!ystickTUP,Po|ystickTUPlus nrPo|ystickXFRisallowable for use under mechanically attached prepared roof systems.
Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if m 2-ply
undedaymentsystem isdesired.
Po|ystick [WTS Plus followed by HydraGuandTile Pro, Pn|yOexSA F\ Po|ystickTU Max, Po|ystickTU P or Po|ystickTU Plus is
allowable for use under adhesive -set tile systems. Limits ofuse are those associated with the top -layer material. This isnot a
requirement, but isallowable ifa2-p|yunder|aymentsystem isdesired.
6.5
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet"in the "Two Ply
System" in the F8SA/TK| Florida High Wind Concrete and (lay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer toSection S.8.land 5.8.3herein for attachment limitations.
Refer toTable 4herein for tile staging limitations.
6.6
6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the"Two Ply System" in
the FRSA/TR! Florida High Wind Concrete and [lay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer toSection 5.O.3herein for attachment limitations.
Refer toTable 4herein for tile staging limitations.
- END ofEVALUATION REPORT -
NEMO ETC,uc Evaluation Report ��.02.09-1130
Certificate ofxvthomotioomm55 7=EDITION (2ozorocmom*vxoEVALUATION aszsu*» (Now*voo
pulyglaaRoof ummnavments Revision nmuu/sa2o21
Page z,mz/