Loading...
HomeMy WebLinkAboutAPPROVED, Philip Beekman TU Plus NOA10/22/21, 9:27 AM Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us ( BCIS Site Map j Links j Search o da i. Product Approval ,x USER: Public User I, , Product Approval Menu > Product or Application Search > 6ppi0tion list > Application Detail FL # FL5259-R33 b Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext242 malpert@polyglass.com Authorized Signature Maury Alpert maIpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email ills West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechnical@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/23/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R33 COI 2021 01 COI NIEMINEN pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 10/22/21, 9:27 AM Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised C11mmary of Prnrlsirtc FM 4474 2011 FRSA/TRI, Sixth Edition 2018 TAS 103 2020 UL1897 2015 Method 1 Option D 04/07/2021 04/12/2021 04/14/2021 06/08/2021 10/15/2021 FL # Model, Number or Name Description 5259.1 Polyglass Roof Underlayments Polyglass; roof underlayments for use in FBC HVHZ jurisdictions. (HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- R33 HVHZ ,pdf Approved for use outside HVHZ: No Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- 33 fflyflD.pff Created by Independent Third Party: Yes 5259.2 Polyglass Roof Underlayments Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions. (non-HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- R33 NON-HVHZ),,pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular underiayment system for FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259- R33 NON-HVHZ)_pdf use in tile roof systems. Refer to ER Section 5.8.3 for other systems and associated maximum design Created by Independent Third Party: Yes pressures. 2.) Refer to ER Section 5 for other limits of use. Ims Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: SSO-487-1824 The State of Florida is an AA/EEO employer. Copy 'aht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick ere . Product Approval Accepts: MMIMEM Credit . ! �11x`'I ,�,,. �.,, https://floddabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlip[oQ53L[fLDSdir7nKfKN%2bQ%3d%3d 2/2 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof 'UnderlayInlentsJor use in FBC nun-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 18. Prepared by: ♦K J li. � Robert J.M. Nieminen, P.E. f,�� R, Q �.2`,r h Florida Registration No. 59166, Florida DCAANE1983 =?./„ 1 w '_ The facsimile seal appearing was authorized by Robert Nieminen, P.E. 04/07/2021. This does not serve as an electronically signed document.. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Jegion 1504.3.1 1504.3.1 1507.1.1 / R905.1.1 1507.1.1, 1507.2.4,1507.2.9.2 / R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 1507.11.2 % R905.11.2 1507.11.2 / R905.11.2 1507.11.2 / R905.11.2 1507.11.2 / R905.11.2 TAS 110 ' ;rroperLy Wind resistance Wind resistance Material standard Material standard Material standard Material standard Material standard Material standard Material standard Accelerated Weathering 'aLalludl u FM 4474 UL 1897 ASTM D226 ASTM D1970 FRSA/TRI, Sixth Edition ASTM D6163 ASTM D6164 ASTM D6222 ASTM D6509 ASTM D4798 , i cat 2011 2015 2009 2015 2018 2015 2011 2011 2015 2011 End Examination Reference Date Ent1tv Examination Reference Date ERD (TST 6049) Wind Uplift 11757.04.01-1-R3 4/25/2001 ERD (TST 6049) FRSA/TRI (tile slippage) PLYG-SC13040.12.16 12/27/2016 ERD (TST 6D49) Wind Uplift 11757.08.01-1 8/13/2001 ERD (TST 6049) FRSA/TRI (tile slippage) PLYG-SC12115.08.17 8/8/2017 ERD (TST 6049) Wind Uplift 11776.06.02 1/16/2003 ERD (TST 6D49) FRSA/TRI PLYG-SC13035.08.17 10/31/2017 ERD (TST 6049) Wind Uplift P1740.01.07 1/4/2007 FM (TST 1867) Wind Uplift FM 3004091 1/12/2DD0 ERD (TST 6049) Wind Uplift P1738.02.07-R2 2/5/2007 NEMO (TST 6049) ASTM D1970 4-PLYG-18-004.03.18 3/29/2018 ERD (TST 6049) Wind Uplift P9260.03.08 3/21/2008 NEMO (TST 6049) ASTM D1623, TAS 103 45-ICP-18-001.07.18-R1 7/23/2018 ERD (TST 6049) Wind Uplift P30540.11.09-111 11/23/2009 NEMO (TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 1/11/2019 ERD (TST 6049) ASTM D1623, TAS 103 P11030.11.09-1 11/30/2009 NEMO (TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 1/24/2019 ERD (TST 6049) TAS 117(B), TAS 114(C) P11030.11.09-2 11/30/2009 NEMO (TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 5/20/2019 ERD (TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 NEMO (TST 6049) FRSA/TRI 4S-PLYG-18-004.10.19-G 10/8/2019 ERD (TST 6049) ASTM D1970 P33360.06.10 6/25/2010 NEMO (TST 6049) FRSAfrRI 4S-PLYG-18-004.10.19-1 10/8/2019 ERD (TST 6049) FRSA/TRI P33370.03.11 3/2/2011 NEMO (TST 6049) FRSA/TRI 4S-PLYG-18-004.10.19-L 10/9/2019 ERD (TST 6049) ASTM D1623, TAS 103 P33370.04.11 4/26/2011 NEMO (TST 6049) FRSA/TRI 45-PLYG-18-004.12.19-F 12/18/2019 ERD (TST 6049) ASTM D1970, D4798 P37300.10.11 10/19/2011 NEMO (TST 6049) FRSA/TRI 4j-PLYG-I9-SSUDL-02.A 1/2/2020 ERD (TST 6049) FRSA/TRI P40390.08.12-1 8/6/2012 NEMO (TST 6049) ASTM D6222 4S-PLYG-18-002.12.19-K-Rl 1/7/2020 ERD (TST 6049) ASTM D1623, TAS 103 P40390.08.12-2 8/7/2012 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.01.20.H 1/14/2020 ERD (TST 6049) ASTM D1623, TAS 103 C41420.09.12-3 9/11/2012 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.01.20.K 1/14/2020 ERD (TST 6049) ASTM D6509 P37590.03.13-1-Ri 2/5/2013 NEMO (TST 6049) FRSA/TRI (tile slippage) 4S-PLYG-18-004.01.20.A 1/16/2020 ERD (TST 6049) TAS 114(J) P39680.03.13 3/4/2013 NEMO (TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.B 1/16/2020 ERD (TST 6049) ASTM D6164 P37590.03.13-3A 3/6/2013 NEMO (TST 6049) FRSA/TRI PLYG-SC15855.05.20.A 5/29/2020 ERD (TST 6D49) ASTM D6164 P37590.07.13-1 7/2/2013 NEMO (TST 6049) FRSA/TRI 4j-PLYG-20-SSUDL-01 7/6/2020 ERD (TST 6049) Wind Uplift P41630.08.13 8/6/2013 NEMO (TST (5049) ASTM D6222 4q-PLYG-I9-SSMBB-05.A 7/23/2020 ERD (TST 6049) ASTM D4601 P45940.09.13 9/4/2013 NEMO (TST 6049) ASTM D4798, D1623 4)-PLYG-I9-SSUDL-05.A 9/10/2020 ERD (TST 6049) ASTM D4601 P45940.09.13 9/4/2013 NEMO (TST 6049) ASTM D1970 4j-PLYG-20-S5UDL-05.A 9/30/2020 ERD (TST 6049) ASTM D1970 (adhesion) P45370.09.13 9/18/2013 NEMO (TST 6049) FRSA/TRI 4j-PLYG-2D-SSUDL-05.0 9/30/2020 ERD (TST 6049) Wind Uplift P11751.05.03-R7 11/26/2013 NEMO (TST 6049) FRSA/TRI 4j-PLYG-20-SSUDL-11.A 10/21/2020 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.12.19.D 10/27/2020 ERD (TST 6049) ASTM D1623, TAS 103 P45270.05.14 5/12/2014 NEMO (TST 6049) FRSA/TRI 4j-PLYG-I9-SSUDL-01.A 11/18/2020 ERD (TST 6049) ASTM D1623, TAS 103 6020.09.14-5 9/8/2014 NEMO (TST 6049) ASTM D1623, TAS 103 4p-ICP-20-SSLAP-01.A 12/15/2020 ERD (TST 6049) ASTM D1623, TAS 103 6020.09.14-6 9/8/2014 NEMO (TST 6049) ASTM D4798, D1623 4j-PLYG-20-SSUDL-13.A 03/02/2021 ERD (TST 6049) ASTM D1623 P46520.10.14 10/3/2014 NEMO (TST 6049) ASTM D1623, TAS 103 4p4CP-20-SSUDL-03.A 03/04/2021 ERD (TST 6049) FRSA/TRI P44360.10.14-RS 10/7/2014 NEMO (TST 6049) ASTM D1623, TAS 103 4j-PLYG-20-SSUDL-07.A 04/07/2021 MEMO ETC, U.C. Evaluation Report P12060.02.09-R29 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 2 of 18 ERD (TST 6049) ASTM D1970, D4798 P43290.10.14 10/17/2014 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 ERD (TST 6049) FRSA/TRI PLYG-SC7550.03.15 3/24/2015 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011 ERD (TST 6049) ASTM D1623 P40390.04.15 4/3/2015 Polyglass USA Materials Affidavit Polystick Compound 01/13/2021 ERD (TST 6049) Wind Uplift PLYG-SC8905.0S.16-1 5/17/2016 PRI (TST5878) UL1897 70aT0058-1 01/13/2021 ERD (TST 6049) ASTM D1970,D4798 PLYG-SC10130.06.16-1 6/27/2016 PRI(TST5878) UL1897 708T0058-6 02/17/2021 ERD (TST 6049) ASTM D1623,TAS 103 PLYG-SC10130.06.16-2 6/27/2016 PRI(TST5878) UL1897 708T0058-7 02/25/2021 ERD (TST 6049) FRSA/TRI PLYG-SC10130.06.16-3 6/27/2016 UL (QUA9625) Quality Control Service Confirmation (FL) 09/13/2018 ERD (TST 6049) ASTM D1970, D4798 PLYG-SC8080.07.16 7/16/2016 UL (QUA9625) Quality Control Service Confirmation (TX) 11/07/2019 ERD (TST 6049) UL1897 - PLYG-SC12025.10.16 10/12/2016 UL (QUA9625) Quality Control Florida BCIS Current ae 0 Product Material Standard Plant(s) Description 4.1 Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet 4.2 Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet 4.3 Elastoflex S6 G ASTM D6164 FL, PA Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI 09-18 4.4 Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI 09-18 4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface 4.6 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a polyester fabric surface 4.7 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI09-18 4.8 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FR) FRSA/TRl09-18 4.9 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRl 09-18 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened or adhered the roof systems 4.10 Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened tile roof systems 4.11 Polyflex SA P ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI 09-18 4.12 Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRl09-18 4.13 Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet 4.14 1 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet MEMO ETC, U.C. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1133 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 3 of 18 4.15 Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface 4.16 Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 PA, TX membrane, glass fiber reinforced, surfaced with polyolefinic film surface 4.17 Polystick MU-X ASTM D19701 FL, NV, PA Nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface 4.18 Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/m2 polyester fabric surface 4.19 Polystick TU P FRSA/TRI 09-18 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface 4.20 Polystick TU Plus ASTM D1970 FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, with a polyester fabric surface 4.21 Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, surfaced with a textured film surface i polystick MU X has been found through comparative testing to have a lesser coefficient of friction thou ASTM! D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 4 of 18 NEMO I etc. 5.6 Allowable Roof Covers: TABLE L ROOF COVER OPTIONS FBCSectlon: 1S07.2 2507.3 IS07.4and 1507.5 1507.7 1507.8and IS07.9 Asphalt Clay and Concrete Tile Slate or Slate- I Underlayment Shingles Metal Type Shingles Woo d Mechanical Attach Adhesive -Set Yes Yes Yes Yes Yes Yes Elastobase (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to D226, Type 11) See 5.8.3) See 5.8.3) D226, Type 11) D226, Type 11) D226, Type 11) Yes Yes Yes Yes Yes Yes Elastobase P (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to D226, Type 11) See 5.8.3) See 5.8.3) D226, Type 11) D226, Type 11) D226, Type 11) Yes Yes Polyglass Base No (as Base Sheet, (as Base Sheet, No No No See 5.8.3) See 5.8.3) Yes Yes Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No See 5.8.3) See 5.8.3) Elastoflex S6 G No Yes Yes No No No (See 5.6.1) Elastoflex S6 G FR No Yes No No No No Yes HydraGuard Dual Pro Yes No No Yes Yes (joint strips, 1507.1.1.3 /11905.1.13) Yes Yes HydraGuard Tile Pro Yes Yes (See 5.6.1) Yes Yes (Joint strips, 1507.1.1.3 R905.1.1.3) Mule -Hide SA-APP Cap Sheet No Yes Yes No No No (See 5.6.1) Mule -Hide SA-APP Cap Sheet (FR) No Yes Yes No No No (See 5.6.1) Polyflex G No Yes Yes No No No (See 5.6.1) Polyflex G FR No Yes No No No No Polyflex SA P No Yes Yes No No No (See 5.6.1) Polyflex SA P FR No Yes Yes No No No (See 5.6.1) Yes Polystick IR-Xe Yes No No No Yes {joint strips, 1507.1.1.3 R905.1.1.3) Yes Polystick MTS Plus Yes Yes No Yes Yes goint strips, 1S07.1.1.3 R905.1.1.3) Yes Polystick MU-X Yes No No Yes Yes (joint strips, 1507.1.1.3 R905.1.1.3) Yes Yes Polystick TU Max No Yes Yes No (Joint strips, 1507.1.1.3 (See 5.6.1) 11905.1.13) Yes Yes Polystick TU P No Yes No No (joint strips, 15071.1.3 (See 5.6.1) R905.1.1.3) Yes Yes Polystick TU Plus Yes Yes Yes Yes (joint strips, 1507.1.1.3 (See 5.6.1) R905.1.1.3) Yes Polystick XFR Yes Yes No Yes Yes (Joint strips, 1507.1.1.3 R905.1.1.3) NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29:04/07/2021 Page 5 of 18 ONEM10jetc. 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE IA' ALLOWABLE UNDERLAYMENT / TILE-ADHE5IVE COMBINATIONe Underlayment Adhesive Florida Product Approval Polystick TU Max, Polystick TU P or Polystick TU Plus DAP Foam "Touch `n Seal StormBond Roof Tile Adhesive" FL14506 PolystickTU P DAP Foam `Touch'n Seal FL21374 StormBond 2 Roof Tile Adhesive" HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick Dupont `Tile Bond- Roof Tile FL22525 TU Plus Adhesive" Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, "Polyset® AH-160" FL6332 Polystick TU P or Polystick TU Plus Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, "Polyset" RTA-1" FL6276 Polystick TU P or Polystick TU Plus 5.7 Allowable Substrates: TABLE 2- SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) HydraGuard Dual Pro, (Optional) ASTM plywood, OSB, Southern Yellow Pine or Huber Engineered HydraGuard Tile Pro, Polystick IR- Deck / D41 Woods "ZIP System" Panels Xe, Polystick MTS Plus, Polystick sheathing ASTM D41 structural concrete MU-X, Polystick TU Max, self ASTM C1289 Type II Class 1 polyisocya nu rate, ASTM Polystick TU P, Polystick TU Plus, adhering Insulation (Optional) ASTM C1289 Type V polyisocyanurate-composite, DensDeck Polystick XFR, Mule -Hide SA-APP D41 or WB-3000 Prime or SECUROCK Gypsum -Fiber Roof Board Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P or Base Sheet N/A ASTM D226, Type II felt, Elastobase, Elastobase P or Mule- Polyflex SA P FR Hide Nail Base Deck ASTM D41 structural concrete Insulation (Optional) ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Elastoflex S6 G or Elastoflex S6 G hot asphalt D41 FR ASTM D226, Type II felt, Elastobase, Elastobase P, Mule - Base Sheet N/A Hide Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete Insulation (Optional) ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board torch- Polyflex G or Polyflex G FR applied D41 Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass Base Sheet N/A G2 Base or Polyglass Base 2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 6 of 18 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: ® FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two - Ply Asphalt Applied Hot Mop Underlayment) or 9 Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #2 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #3 Maximum Design Pressure = -97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/<" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. MEMO ETC, LLC. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1133 (NON-HVHZ) Potyglass Roof Underlayments Revision 29: 04/07/2021 Page 7 of 18 #5 Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #6 Maximum Design Pressure = -165 psf: Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Categoryto meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #7 Maximum Design Pressure = -202.5 psf: Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 at 0.5 gal/square Base Ply: Polystick MTS Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #8 Maximum Design Pressure = -255 nsf: Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 at 0.5 gal/square. Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.. #9 Maximum Design Pressure = -315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #10 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #11 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRl Florida High Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. NEMO ETC, U.C. Evaluation Report P12060.02.09-R29 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 8 of 18 ONEMOletc. #12 Maximum Design Pressure = -30.0 psf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #13 Maximum Design Pressure = -37.5 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) -- Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #14 Maximum Design Pressure = -37.5 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #15 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #16 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt. #17 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. - Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, U.C. Evaluation Report P12MG0.02.09-R29 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polygiass Roof Underlayments Revision 29: 04/07/2021 Page 9 of 18 #18 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #20 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #21 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #23 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #24 Maximum Design Pressure = -60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #25 Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. MEMO ETC, U.C. Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments Evaluation Report P12060.02.09-R29 FL5259-R33 (NON-HVHZ) Revision 29: 04/07/2021 Page 10 of 18 ONEMOIetc. #26 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #27 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastofiex S6 G, applied in full mopping of hot asphalt. #28 Maximum Design Pressure = -60.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #29 Maximum Design Pressure = -67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment) Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastofiex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #30 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #31 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F15259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 11 of 18 ONEMOletc. #32 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 0513 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #33 Maximum Design Pressure = -75 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #34 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #35 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #36 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #37 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied Underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #38 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, LLC. Evaluation Report 1212060.02.09-1129 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION 171.5259-1133 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 12 of 18 ONEMOletc. #39 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. #40 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #41 Maximum Design Pressure = -97.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #42 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #43 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #44 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #45 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P12060.02.09-R29 Certificate ofAuthorizotion #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 13 of 18 ONEMOletc. #46 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #47 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #48 Maximum Design Pressure = -105.0 nsf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #49 Maximum Design Pressure = -112.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS Plus, self -adhered Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #50 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #51 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-14VHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 14 of 18 NNEMO C etc. #52 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. - Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TU Plus, self -adhered. #53 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. #54 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base Mechanically attached 30 Polystick IR-Xe or Polystick MU-X Mechanically attached 90 HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Any type (per Table 1) 180 Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR Adhesive -set tile roof system 180 Mechanically attached UNLIMITED NEW ETC, U.C. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 15 of 1S ONEMOletc. 5.10 When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall beasfollows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. Underlayment Tile Profile Staging Method Maximum Staging Slope Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) Prohibited without battens HydraGuard Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens 61 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the Limitations set forth inSection 5herein and the specifics noted below. 5.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly toremove any dust and debris prior toapplication, and prime the substrate (if appUcab|c). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick yNU4(PoiysUckTU Max, Po|ystickTU F,Po{ystickTUPlus, Po|ystickXFn'PolyOexSAP, Poiy8exSAPFR, Mule -Hide SA,APPCap Sheet orSA-APPCap Sheet (FR),sdf'adhered,E(astoOexSGGorE|axtoflex56 GFRinhot asphalt nrPo/yOex6orPo|yOexG Fn,torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. §.3.2 Tile Applications: 6.3.I.1 Bugobase(poly-film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRl Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed byPu|ystickK4T3Plus, Po|ystickTU Max, Po|yst(ckTUP,Po|ystickTUPlus, Po!ystickXFR,Po!yOexSAP, Po}yUex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cup Sheet, osset forth in Table 1. Refer toSection 5.8.3.2 herein for attachment requirements. NEMO ETC,uc Evaluation Report P12060.02.09-R29 Certificate ofAvth"m000nmo45s r-EDITION (2oauFBCmom*vozEVALUATION FL5259-R33<mom-Hvoz pokmmssRoof unwmnannems Revision 29:owm7/ano Page xa**un ONEMOjetc. 6.3.2.2 Elastobase (sanded -top) and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the "TW0- PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. ® When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6 G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 or Section 5.8.3.2 herein for attachment requirements. ® When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR, refer to Section 5.8.3.2 herein for attachment requirements. 6.4 6.4.1 General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro 6.4.2 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.3 Tile_ Applications (excludes HydraGuard Dual Pro, Polystick IR Xe and Polystick MU-X): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.4.4 Multi -Ply Underlayment Systems: Polystick NITS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1129 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ) Polyglass Roof Underlayments Revision 29: 04/07/2021 Page 17 of 18 8.5 65.1 Shall beinstalled Uncompliance with requirements aoanalternate tnthe "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and {lay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer toSection 5fLZand 5.83herein for attachment limitations. Refer toTable 4herein for tile staging limitations. 6.6 6.6.1 Shall beinstalled Uncompliance with requirements asanalternate tuthe "Heat Applied Cap Sheet" mthe "Two Ply System" in the FRS4yTR/ Florida High Wind {bnoe0e and Clay Roof Tile installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer tuSection 5.l3herein for attachment limitations. Refer toTable 4herein for tile staging limitations. -END OF EVALUATION REPORT - NEMOETC, uc Evaluation Report P12060.02.09-R29 Certificate ofAoth"mmtioo#3ae5 7=EDITION (2oznmCmom*vxZEVALUATION nsuss-Rs (Now*xxZ) Polyglass Roof undewayments; Revision ay:nw^n/oo1 Page Ixnfzo