HomeMy WebLinkAboutAPPROVED, Philip Beekman TU Plus NOA10/22/21, 9:27 AM Florida Building Code Online
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us ( BCIS Site Map j Links j Search
o da
i. Product Approval
,x USER: Public User
I, ,
Product Approval Menu > Product or Application Search > 6ppi0tion list > Application Detail
FL # FL5259-R33
b Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer
POLYGLASS USA
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
maIpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email ills West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R33 COI 2021 01 COI NIEMINEN pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4798
2011
ASTM D6163
2015
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2015
10/22/21, 9:27 AM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
C11mmary of Prnrlsirtc
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
TAS 103
2020
UL1897
2015
Method 1 Option D
04/07/2021
04/12/2021
04/14/2021
06/08/2021
10/15/2021
FL #
Model, Number or Name
Description
5259.1
Polyglass Roof Underlayments
Polyglass; roof underlayments for use in FBC HVHZ jurisdictions.
(HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 HVHZ ,pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
33 fflyflD.pff
Created by Independent Third Party: Yes
5259.2
Polyglass Roof Underlayments
Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions.
(non-HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 NON-HVHZ),,pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular underiayment system for
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 NON-HVHZ)_pdf
use in tile roof systems. Refer to ER Section 5.8.3
for other systems and associated maximum design
Created by Independent Third Party: Yes
pressures. 2.) Refer to ER Section 5 for other limits
of use.
Ims
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: SSO-487-1824
The State of Florida is an AA/EEO employer. Copy 'aht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick ere .
Product Approval Accepts:
MMIMEM
Credit
. !
�11x`'I
,�,,. �.,,
https://floddabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlip[oQ53L[fLDSdir7nKfKN%2bQ%3d%3d 2/2
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof 'UnderlayInlentsJor use in FBC nun-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 18.
Prepared by:
♦K J li. �
Robert J.M. Nieminen, P.E.
f,�� R, Q �.2`,r h
Florida Registration No. 59166, Florida DCAANE1983
=?./„ 1 w '_ The facsimile seal appearing was authorized by Robert Nieminen, P.E.
04/07/2021. This does not serve as an electronically signed document..
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Jegion
1504.3.1
1504.3.1
1507.1.1 / R905.1.1
1507.1.1, 1507.2.4,1507.2.9.2 /
R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
1507.11.2 % R905.11.2
1507.11.2 / R905.11.2
1507.11.2 / R905.11.2
1507.11.2 / R905.11.2
TAS 110
' ;rroperLy
Wind resistance
Wind resistance
Material standard
Material standard
Material standard
Material standard
Material standard
Material standard
Material standard
Accelerated Weathering
'aLalludl u
FM 4474
UL 1897
ASTM D226
ASTM D1970
FRSA/TRI, Sixth Edition
ASTM D6163
ASTM D6164
ASTM D6222
ASTM D6509
ASTM D4798
, i cat
2011
2015
2009
2015
2018
2015
2011
2011
2015
2011
End
Examination
Reference Date
Ent1tv
Examination
Reference
Date
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R3 4/25/2001
ERD (TST 6049)
FRSA/TRI (tile slippage)
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6D49)
Wind Uplift
11757.08.01-1 8/13/2001
ERD (TST 6049)
FRSA/TRI (tile slippage)
PLYG-SC12115.08.17
8/8/2017
ERD (TST 6049)
Wind Uplift
11776.06.02 1/16/2003
ERD (TST 6D49)
FRSA/TRI
PLYG-SC13035.08.17
10/31/2017
ERD (TST 6049)
Wind Uplift
P1740.01.07 1/4/2007
FM (TST 1867)
Wind Uplift
FM 3004091
1/12/2DD0
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2 2/5/2007
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
3/29/2018
ERD (TST 6049)
Wind Uplift
P9260.03.08 3/21/2008
NEMO (TST 6049)
ASTM D1623, TAS 103
45-ICP-18-001.07.18-R1
7/23/2018
ERD (TST 6049)
Wind Uplift
P30540.11.09-111 11/23/2009
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
1/11/2019
ERD (TST 6049)
ASTM D1623, TAS 103
P11030.11.09-1 11/30/2009
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A
1/24/2019
ERD (TST 6049)
TAS 117(B), TAS 114(C)
P11030.11.09-2 11/30/2009
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19-C
5/20/2019
ERD (TST 6049)
ASTM D4977
P11030.11.09-3 11/30/2009
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.10.19-G
10/8/2019
ERD (TST 6049)
ASTM D1970
P33360.06.10 6/25/2010
NEMO (TST 6049)
FRSAfrRI
4S-PLYG-18-004.10.19-1
10/8/2019
ERD (TST 6049)
FRSA/TRI
P33370.03.11 3/2/2011
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.10.19-L
10/9/2019
ERD (TST 6049)
ASTM D1623, TAS 103
P33370.04.11 4/26/2011
NEMO (TST 6049)
FRSA/TRI
45-PLYG-18-004.12.19-F
12/18/2019
ERD (TST 6049)
ASTM D1970, D4798
P37300.10.11 10/19/2011
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-I9-SSUDL-02.A
1/2/2020
ERD (TST 6049)
FRSA/TRI
P40390.08.12-1 8/6/2012
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.12.19-K-Rl
1/7/2020
ERD (TST 6049)
ASTM D1623, TAS 103
P40390.08.12-2 8/7/2012
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.01.20.H
1/14/2020
ERD (TST 6049)
ASTM D1623, TAS 103
C41420.09.12-3 9/11/2012
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.01.20.K
1/14/2020
ERD (TST 6049)
ASTM D6509
P37590.03.13-1-Ri 2/5/2013
NEMO (TST 6049)
FRSA/TRI (tile slippage)
4S-PLYG-18-004.01.20.A
1/16/2020
ERD (TST 6049)
TAS 114(J)
P39680.03.13 3/4/2013
NEMO (TST 6049)
ASTM D6164
4S-PLYG-18-004.01.20.B
1/16/2020
ERD (TST 6049)
ASTM D6164
P37590.03.13-3A 3/6/2013
NEMO (TST 6049)
FRSA/TRI
PLYG-SC15855.05.20.A
5/29/2020
ERD (TST 6D49)
ASTM D6164
P37590.07.13-1 7/2/2013
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-01
7/6/2020
ERD (TST 6049)
Wind Uplift
P41630.08.13 8/6/2013
NEMO (TST (5049)
ASTM D6222
4q-PLYG-I9-SSMBB-05.A
7/23/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13 9/4/2013
NEMO (TST 6049)
ASTM D4798, D1623
4)-PLYG-I9-SSUDL-05.A
9/10/2020
ERD (TST 6049)
ASTM D4601
P45940.09.13 9/4/2013
NEMO (TST 6049)
ASTM D1970
4j-PLYG-20-S5UDL-05.A
9/30/2020
ERD (TST 6049)
ASTM D1970 (adhesion)
P45370.09.13 9/18/2013
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-2D-SSUDL-05.0
9/30/2020
ERD (TST 6049)
Wind Uplift
P11751.05.03-R7 11/26/2013
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-11.A
10/21/2020
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1 11/26/2013
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.12.19.D
10/27/2020
ERD (TST 6049)
ASTM D1623, TAS 103
P45270.05.14 5/12/2014
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-I9-SSUDL-01.A
11/18/2020
ERD (TST 6049)
ASTM D1623, TAS 103
6020.09.14-5 9/8/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-SSLAP-01.A
12/15/2020
ERD (TST 6049)
ASTM D1623, TAS 103
6020.09.14-6 9/8/2014
NEMO (TST 6049)
ASTM D4798, D1623
4j-PLYG-20-SSUDL-13.A
03/02/2021
ERD (TST 6049)
ASTM D1623
P46520.10.14 10/3/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4p4CP-20-SSUDL-03.A
03/04/2021
ERD (TST 6049)
FRSA/TRI
P44360.10.14-RS 10/7/2014
NEMO (TST 6049)
ASTM D1623, TAS 103
4j-PLYG-20-SSUDL-07.A
04/07/2021
MEMO ETC, U.C.
Evaluation Report P12060.02.09-R29
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZ
EVALUATION
FL5259-R33
(NON-HVHZ)
Polyglass Roof Underlayments
Revision 29: 04/07/2021
Page 2 of 18
ERD (TST 6049) ASTM D1970, D4798 P43290.10.14 10/17/2014 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
ERD (TST 6049) FRSA/TRI PLYG-SC7550.03.15 3/24/2015 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
ERD (TST 6049) ASTM D1623 P40390.04.15 4/3/2015 Polyglass USA Materials Affidavit Polystick Compound 01/13/2021
ERD (TST 6049) Wind Uplift PLYG-SC8905.0S.16-1 5/17/2016 PRI (TST5878) UL1897 70aT0058-1 01/13/2021
ERD (TST 6049) ASTM D1970,D4798 PLYG-SC10130.06.16-1 6/27/2016 PRI(TST5878) UL1897 708T0058-6 02/17/2021
ERD (TST 6049) ASTM D1623,TAS 103 PLYG-SC10130.06.16-2 6/27/2016 PRI(TST5878) UL1897 708T0058-7 02/25/2021
ERD (TST 6049) FRSA/TRI PLYG-SC10130.06.16-3 6/27/2016 UL (QUA9625) Quality Control Service Confirmation (FL) 09/13/2018
ERD (TST 6049) ASTM D1970, D4798 PLYG-SC8080.07.16 7/16/2016 UL (QUA9625) Quality Control Service Confirmation (TX) 11/07/2019
ERD (TST 6049) UL1897 - PLYG-SC12025.10.16 10/12/2016 UL (QUA9625) Quality Control Florida BCIS Current
ae 0
Product Material Standard Plant(s) Description
4.1
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
4.2
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
4.3
Elastoflex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
4.4
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
4.5
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
4.6
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
4.7
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI09-18
4.8
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRl09-18
4.9
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRl 09-18
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered the
roof systems
4.10
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
4.11
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
4.12
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRl09-18
4.13
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
4.14
1 Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
MEMO ETC, U.C. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1133 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 3 of 18
4.15
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
4.16
Polystick MTS Plus
ASTM D1970
FL, NV,
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
PA, TX
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
4.17
Polystick MU-X
ASTM D19701
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
4.18
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane with a 190 g/m2 polyester fabric surface
4.19
Polystick TU P
FRSA/TRI 09-18
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
4.20
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
4.21
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, surfaced with a
textured film surface
i polystick MU X has been found through comparative testing to have a lesser coefficient of friction thou ASTM! D226 roofing felt in a dry condition, tested at standard
laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 4 of 18
NEMO I etc.
5.6 Allowable Roof Covers:
TABLE L ROOF COVER OPTIONS
FBCSectlon:
1S07.2
2507.3
IS07.4and 1507.5
1507.7
1507.8and IS07.9
Asphalt
Clay and Concrete Tile
Slate or Slate-
I
Underlayment
Shingles
Metal
Type Shingles
Woo d
Mechanical Attach
Adhesive -Set
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
D226, Type 11)
See 5.8.3)
See 5.8.3)
D226, Type 11)
D226, Type 11)
D226, Type 11)
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
(Alternate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Alternate to
D226, Type 11)
See 5.8.3)
See 5.8.3)
D226, Type 11)
D226, Type 11)
D226, Type 11)
Yes
Yes
Polyglass Base
No
(as Base Sheet,
(as Base Sheet,
No
No
No
See 5.8.3)
See 5.8.3)
Yes
Yes
Polyglass G2 Base
No
(as Base Sheet,
(as Base Sheet,
No
No
No
See 5.8.3)
See 5.8.3)
Elastoflex S6 G
No
Yes
Yes
No
No
No
(See 5.6.1)
Elastoflex S6 G FR
No
Yes
No
No
No
No
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
(joint strips, 1507.1.1.3
/11905.1.13)
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
(See 5.6.1)
Yes
Yes
(Joint strips, 1507.1.1.3
R905.1.1.3)
Mule -Hide SA-APP Cap Sheet
No
Yes
Yes
No
No
No
(See 5.6.1)
Mule -Hide SA-APP Cap Sheet (FR)
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex SA P FR
No
Yes
Yes
No
No
No
(See 5.6.1)
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
{joint strips, 1507.1.1.3
R905.1.1.3)
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
goint strips, 1S07.1.1.3
R905.1.1.3)
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
(joint strips, 1507.1.1.3
R905.1.1.3)
Yes
Yes
Polystick TU Max
No
Yes
Yes
No
(Joint strips, 1507.1.1.3
(See 5.6.1)
11905.1.13)
Yes
Yes
Polystick TU P
No
Yes
No
No
(joint strips, 15071.1.3
(See 5.6.1)
R905.1.1.3)
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes
Yes
(joint strips, 1507.1.1.3
(See 5.6.1)
R905.1.1.3)
Yes
Polystick XFR
Yes
Yes
No
Yes
Yes
(Joint strips, 1507.1.1.3
R905.1.1.3)
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29:04/07/2021
Page 5 of 18
ONEM10jetc.
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE IA' ALLOWABLE UNDERLAYMENT / TILE-ADHE5IVE COMBINATIONe
Underlayment
Adhesive
Florida Product Approval
Polystick TU Max, Polystick TU P or Polystick TU Plus
DAP Foam "Touch `n Seal
StormBond Roof Tile Adhesive"
FL14506
PolystickTU P
DAP Foam `Touch'n Seal
FL21374
StormBond 2 Roof Tile Adhesive"
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick
Dupont `Tile Bond- Roof Tile
FL22525
TU Plus
Adhesive"
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset® AH-160"
FL6332
Polystick TU P or Polystick TU Plus
Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max,
"Polyset" RTA-1"
FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
TABLE 2- SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed
to meet wind loads for project)
Underlayment
Application
Type
Primer
Material(s)
HydraGuard Dual Pro,
(Optional) ASTM
plywood, OSB, Southern Yellow Pine or Huber Engineered
HydraGuard Tile Pro, Polystick IR-
Deck /
D41
Woods "ZIP System" Panels
Xe, Polystick MTS Plus, Polystick
sheathing
ASTM D41
structural concrete
MU-X, Polystick TU Max,
self
ASTM C1289 Type II Class 1 polyisocya nu rate, ASTM
Polystick TU P, Polystick TU Plus,
adhering
Insulation
(Optional) ASTM
C1289 Type V polyisocyanurate-composite, DensDeck
Polystick XFR, Mule -Hide SA-APP
D41 or WB-3000
Prime or SECUROCK Gypsum -Fiber Roof Board
Cap Sheet, Mule -Hide SA-APP
Cap Sheet (FR), Polyflex SA P or
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P or Mule-
Polyflex SA P FR
Hide Nail Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Elastoflex S6 G or Elastoflex S6 G
hot asphalt
D41
FR
ASTM D226, Type II felt, Elastobase, Elastobase P, Mule -
Base Sheet
N/A
Hide Nail Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Insulation
(Optional) ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
torch-
Polyflex G or Polyflex G FR
applied
D41
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
Base Sheet
N/A
G2 Base or Polyglass Base
2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 6 of 18
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —
for mechanically attached base sheets - not less than:
® FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
9 Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure = -97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/<" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
MEMO ETC, LLC. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1133 (NON-HVHZ)
Potyglass Roof Underlayments Revision 29: 04/07/2021
Page 7 of 18
#5 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure = -165 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Categoryto meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: None
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#7 Maximum Design Pressure = -202.5 psf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) PG100 at 0.5 gal/square
Base Ply: Polystick MTS Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails
through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#8 Maximum Design Pressure = -255 nsf:
Deck: APA Rated Sheathing, 32/16, Exposure 1, PS 1-09,15/32 Category to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: PG100 at 0.5 gal/square.
Underlayment: Polystick TU Max or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X"
ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c..
#9 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#10 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#11 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRl Florida High
Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R29
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 8 of 18
ONEMOletc.
#12 Maximum Design Pressure = -30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#13 Maximum Design Pressure = -37.5 psf*:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface) --
Fasteners:
11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#14 Maximum Design Pressure = -37.5 psf*:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
One (1) or two (2) layers ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing:
6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#15 Maximum Design Pressure = -45 psf*:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
One (1) layer ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#16 Maximum Design Pressure = -45 psf*:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Two (2) layers ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
#17 Maximum Design Pressure = -45 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure = -45.0 psf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS Plus, self -adhered. -
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, U.C. Evaluation Report P12MG0.02.09-R29
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polygiass Roof Underlayments Revision 29: 04/07/2021
Page 9 of 18
#18 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#20 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#21 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#24 Maximum Design Pressure = -60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#25 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
MEMO ETC, U.C.
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-R29
FL5259-R33 (NON-HVHZ)
Revision 29: 04/07/2021
Page 10 of 18
ONEMOIetc.
#26 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#27 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastofiex S6 G, applied in full mopping of hot asphalt.
#28 Maximum Design Pressure = -60.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#29 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastofiex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#31 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R29
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F15259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 11 of 18
ONEMOletc.
#32 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 0513 sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#33 Maximum Design Pressure = -75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#35 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#36 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#37 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied Underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#38 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, LLC. Evaluation Report 1212060.02.09-1129
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION 171.5259-1133 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 12 of 18
ONEMOletc.
#39 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#40 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#41 Maximum Design Pressure = -97.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#42 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#44 Maximum Design Pressure = -97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R29
Certificate ofAuthorizotion #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 13 of 18
ONEMOletc.
#46 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#47 Maximum Design Pressure = -105.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#48 Maximum Design Pressure = -105.0 nsf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180" into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#49 Maximum Design Pressure = -112.5 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer at all tin -caps
Base Ply:
Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#50 Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#51 Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface)
Fasteners:
Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-14VHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 14 of 18
NNEMO C etc.
#52 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered. -
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#53 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#54 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
Mechanically attached
30
Polystick IR-Xe or Polystick MU-X
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table 1)
180
Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
Adhesive -set tile roof system
180
Mechanically attached
UNLIMITED
NEW ETC, U.C. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 15 of 1S
ONEMOletc.
5.10 When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall beasfollows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
HydraGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
61 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth inSection 5herein and the specifics noted below.
5.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly toremove any dust
and debris prior toapplication, and prime the substrate (if appUcab|c).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
yNU4(PoiysUckTU Max, Po|ystickTU F,Po{ystickTUPlus, Po|ystickXFn'PolyOexSAP, Poiy8exSAPFR, Mule -Hide SA,APPCap
Sheet orSA-APPCap Sheet (FR),sdf'adhered,E(astoOexSGGorE|axtoflex56 GFRinhot asphalt nrPo/yOex6orPo|yOexG
Fn,torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table
1.
§.3.2 Tile Applications:
6.3.I.1 Bugobase(poly-film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the "TWO-PLY SYSTEM" from FRSA/TRl Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, followed byPu|ystickK4T3Plus, Po|ystickTU Max, Po|yst(ckTUP,Po|ystickTUPlus, Po!ystickXFR,Po!yOexSAP, Po}yUex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile
roof installation method is limited by the selected Cup Sheet, osset forth in Table 1. Refer toSection 5.8.3.2 herein for
attachment requirements.
NEMO ETC,uc Evaluation Report P12060.02.09-R29
Certificate ofAvth"m000nmo45s r-EDITION (2oauFBCmom*vozEVALUATION FL5259-R33<mom-Hvoz
pokmmssRoof unwmnannems Revision 29:owm7/ano
Page xa**un
ONEMOjetc.
6.3.2.2 Elastobase (sanded -top) and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the "TW0-
PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex
G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1.
® When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6
G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1
or Section 5.8.3.2 herein for attachment requirements.
® When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR, refer
to Section 5.8.3.2 herein for attachment requirements.
6.4
6.4.1 General:
All seal -lap seams (selvage laps) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or
Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile_ Applications (excludes HydraGuard Dual Pro, Polystick IR Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -Ply Underlayment Systems:
Polystick NITS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1129
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R33 (NON-HVHZ)
Polyglass Roof Underlayments Revision 29: 04/07/2021
Page 17 of 18
8.5
65.1 Shall beinstalled Uncompliance with requirements aoanalternate tnthe "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and {lay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer toSection 5fLZand 5.83herein for attachment limitations.
Refer toTable 4herein for tile staging limitations.
6.6
6.6.1 Shall beinstalled Uncompliance with requirements asanalternate tuthe "Heat Applied Cap Sheet" mthe "Two Ply System" in
the FRS4yTR/ Florida High Wind {bnoe0e and Clay Roof Tile installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer tuSection 5.l3herein for attachment limitations.
Refer toTable 4herein for tile staging limitations.
-END OF EVALUATION REPORT -
NEMOETC, uc Evaluation Report P12060.02.09-R29
Certificate ofAoth"mmtioo#3ae5 7=EDITION (2oznmCmom*vxZEVALUATION nsuss-Rs (Now*xxZ)