HomeMy WebLinkAboutAPPROVED, Roofing Acessory off ridge FL21580-R2(1)1 /4/202 1 Florida Building Code Online SCIS Home Log In I User Registration Hot Topics Submit Surcharge Stats & Facts b c� �D,,- r 14 Product Approval USER: Public user Product Approval Menu > Product or Application S rclt > Application Llst > Application Detail FL # FL21580-R2 Application Type Revision Code Version 2020 Application Status Approved Comments Archived ,� a Publications Contact its 8CIS Sita Map Lnks Search Product Manufacturer Florida Metal Products Inc. Address/Phone/Email 6940 Stuart Ave Jacksonville, FL 32254 (904) 783-8400 Clark@flamco.com Authorized Signature FLPA Services flpaserv@yahoo.com Technical Representative Clark jones Address/Phone/Email p 0 box 6310 jacksonvilie, FL 32236 (904)783-8400 Clark@fiamco.com Quality Assurance Representative Clark jones Address/Phone/Email p o box 6310 jacksonviile, FL 32236 (904) 783-8400 Clark@fiamco.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Fngineer or Architect Name who developed the lames L. Bucker, P,E.@ CBUCK Engineering Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL21980 R2 COI Certificate f1n ep_pdf 1708.2 https://floridabuiiding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtcQ%2f8oYQLm9hCWpByUNeLDe8C%2bOtzNLd3DivaH4nc86Q%3d%3d 7/2 1 /412021 Florida Building Cade Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Method 2 Option B 09/25/2020 09/27/2020 10/04/2020 12/16/2020 EL # I Model, Number or Name 21580,1 1 - FLAMCO "Off -Ridge Roof Vent" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure:-tN/A/-46 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 21580.2 � 2 - FLAMCO "Gooseneck Roof Vent" (Limits of Use Approved for use in HVHZ; No Approved for use outside HVHZ; Yes Impact Resistant: No Design Pressure: -rN/A/-90 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 21580.3 ( 3 - FLAMCO "RV 10 Ridge Vent" Description Low profile, off -ridge roof vent for pitched roofs fabricated from 26 gauge, G-90 primed, galvanized steel — .. ................ ... Installation Instructions FL21580 R2 II 1 OffRidgeRoofVent EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL21580 R2 AE i OffRid eRoofVent EVALREPORT.pdf Created by Independent Third Party; Yes Gooseneck style roof vents for sloped shingle or tile roofs fabricated from 26 gauge, G-90 primed, galvanized steel _-........... ........ - ..... — Installation Instructions FL21580 R2 II 2 GooseneckR00fVent EVALREPORT pdf Verified By: James L. Buckner, P.E, @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL21580 R2 AE 2 Goo5oneckRoofVent EVALREP RT.p:f Created by Independent Third Party: Yes Aluminum Ridge Vents for pitched roofs fabricated from 0.025" Aluminum Limits of Use Installation Instructions Approved for use in HVHZ: No FL21580 R2 II 3 RVID RidggVVent EVALREPORT pdf Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL21580 R2 AE 3 RV10 RidgeVent EVALREPORT.pdf instructions as a supplemental guide for attachment. Created by Independent Third Party: Yes Contact us :: 2601 3[air Stone Road, Tallahassee Ft. 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copy_rjg ht 2007-2013 State of Florida :: Privac Statement :: Accessibility Statement :: Refu 1d Statement Under Fforida law, email addresses are public records. if you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional ,nail. If you have any questions, please contact 8513.487.1395. "Pursuant to section 455.275j1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The enrolls provided may be used for official commurication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please pTOVlde the Department with an email address which can be made avaihablc to the public. To determine it you are a licensee under Chapter 455, F.S., please click here . Product Approvar Accepts ®hec_k Credit Cara Safe httpsa/floridabuilding.org/prlpr_app_dtl.aspx?pnram=wCEVXQMDqfcQn/v2f8oYOLrn9hCWpByL)NeLDe8C°/`2bC)tzNLd3DivaH4ncB6Q°/a3d°/ 3d 2/2 CSUCK Engineering Sppcialf ti Structural Engineerinq Evaluation Report FLAMCO "Off -Ridge Vent" Roof Vent Manufacturer: Florida Metal Products, Inc. 6940 Stuart Avenue Jacksonville, FL 32254 for Florida Product Approval # FL 21580.1 R2 CBUCK, Inc. Certificate of Authorization #8054 Florida Building Code 7th Edition (2020) Method: Category: Sub - Category: Product Name: Product Description: Attached To: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE 1D: 1916 Project Manager: Diana Galloway Report No. Report No. 20-244- ORV-ER (Revises 17-185-ORV-Eft, FL 21580.1) Date: 09 / 25 / 20 Contents: Evaluation Report Pages 1-9 MW Roofing Roofing Accessories that are an Integral Part of the Roofing System "Off -Ridge Vent" Roof Vent Wood Deck This item has been electrnnically signed and sealed by James L. Buckner, P.E., on this date using a Digital Signature. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. ``y\ �5 4.L iBUC�f * ' No 31242 --0 * c- 7� IV �o STATE OF �i � •'•.'CLORIOP` •'' � � �rrrrrlllltt�� 2020.09.25 1433:30-04'00` CBUCK, Inc. dba CBUCK Engineering Phone: (561) 491-9927 , Email: cbuck cbuckinc.net • Website: www.cbuclunc.net Business: 1374 Communitv Dr.. Jupiter. FL 33458 . Coro/Mailine: 2637 E. Atlantic Blvd, #340 99. Pomnann Roark FI lgng) Specialty Structural Englneerinq 1.0 Manufacturer: Florida Metal Products, Inc. dba FLAMCO 6940 Stuart Avenue Jacksonville, Florida 32254 (800) 634-8400 htt flamco.com 2.0 Manufacturing Plant: Jacksonville, Florida 3.0 Product: 3.1 Product Name: "Off -Ridge Vent" 3.2 Product Description: Roof Vent 4.0 Evaluation Scope: 4.1 Compliance with the following Florida Building Code 7th Fdition (2020) FL #: FL 21580.1 R2 Date: 09 / 25 / 20 Report No.: 20-244-ORV-ER Page 2 of 5 CBUCK, Inc. Certificate of Authorization #8064 4.2 Evaluation Method: Florida Product Approval Rule 61G20-3.005 (2) (b) 4.3 Evaluation Classification: Category: Roofing Sub Category: Roofing Accessories that are an Integral part of the Roofing System 4.4 Properties Evaluated Structural (Wind Resistance) Properties 4.5 Limits of Evaluation: This product assembly evaluation is limited to compliance with section 4.1 to section 4.4 of this report. 5.0 Evaluated Uses: FLAMCO "Off -Ridge Vent" is used as a roof ventilator. 6.0 Product Assembly Description: 6.1 General: The FLAMCO "Off -Ridge Vents" are low profile, off -ridge roof vent for pitched roofs fabricated from 26 gauge, G-90 primed, galvanized steel with a galvanized steel mesh covering mechanically attached to Plywood Deck. 7.0 General Assembly as Evaluated: Refer to section 15.0 of this report for product assembly components/materials & standards. 8.0 Support System: (Design of support system is outside the scope of this evaluation.) 8.1 Type: Wood Deck 8.2 Description: 15/32" (min.) or greater plywood, or 9.0 Slope: Wood plank deck (based on minimum density/specific gravity of 0,42) Minimum slope shall be 2:12. (and in compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections and in accordance with manufacturer's recommendations,) FL #: FL 21580.1 R2 Date: 09 / 25 / 20 C ' BUCK Engineering Report No.: 20-244-ORV-ER Page 3 of 5 SPeeialty Sf ructural Engineering CBUCK, Inc. Certificate of Authorization #8064 10.0 Performance: 10.1 Wind Resistance: Table A Allowable Loads Design Uplift Pressure -46 PSF Notes: Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1. 11.0 Performance Standard: The following test protocols were performed to demonstrate compliance with the intent of the code: 11.1 ASTM E330-02 -- Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference 12.0 Code Compliance: 12.1 The product assembly described herein has demonstrated compliance with the Florida Building Code 7th Edition (2020) Section 1708.2. 13.0Limitations and Conditions of Use: 13.1 Design of support system is outside the scope of this report. Support shall be structural framing members complying with the code and shall be designed by others. 13.2 Scope of "Limitations and Conditions of Use" for this evaluation: This evaluation report for "State Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.00S. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "State Approval". 13.3 Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. 13.4 This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval forthe listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. 13.5 Structural loads shall comply with the design provisions of the FBC 7th Edition (2020), Chapter 16, Section 1609. 13.6 All metal components and fasteners shall be corrosion resistant in accordance with FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. 13.7 Refer to applicable building code section for ventilation requirements. 13.8 Fire Classification is outside the scope of Rule 61G20--3, and is therefore not included in this evaluation. 13.9 This report does not evaluate the use of this product assembly as described in this report for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) 1.4.0Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc., (FBC Organization #QUA ID:1824). FL #: FL 21580.1 R2 -� Date: 09 / 25 / 20 Report No.: 20-244-ORV-ER Page 4 of 5 SpecialtLi Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 15.0 System/Components 15.1 "Off Ridge Vent" 15.1.1 Material: Steel 15.1.2 Thickness: 26 gauge (min.) 15.1.3 Yield Strength: 40 ksi min. 15.1.4 Corrosion Resistance: In compliance with FBC Section 1507.4.3: ASTM A792 coated, or ASTM A653 G90 galvanized steel 15.1.5 Overall Product Dimensions (1 %" nominal): 15.1.5.1 Length(s): 2', 4', 6' and 8' (max.) 15.1.5.2 Width: 23-1/2" (max.) 15.1.5.3 Height: 4-1/2" and 8-1/2" (max.) 15.2 Fastener: 15.2.1 Base Fastener: 15.2.1.1 Type: 15.2.1.2 Size: 15.2.1.3 Corrosion Resistance: 15.2.1.4 Standard: 15.3 Roof Adhesive: Attaches Roof Vent to Deck Smooth or Ring Shank Roofing Nails 11 gauge x 2" (Long) Per FBC Section 1506.5 Per ASTM F 1667 15.3.1 Type: Standard Heavy bodied Flashing Cement 15.3.2 Description: Asbestos -free asphalt based roof cement 15.3.3 Application Size: 1/4" thick (min.) 15.3.4 Standard: Per ASTM D 4586 Type I 16.0 Installation Method: (Refer to installation method at the end of this evaluation report.) Prepare deck opening by trimming any shingles or tiles & existing nails that may interfere with ridge vent installation. Apply roof cement to the underside, back and side flanges of the ridge vent. Cement should be a 1/4" thick and extend 2" onto roof underlayment. (Install cement in compliance with manufacturer's installation guidelines.) Position vent base flange beneath loosened shingles and align with deck opening. Attach the unit side flanges to deck with fasteners per Section 15.2.1 spaced 4" o.c. and 1" from each end. Apply Roofing Cement to exposed fastener heads. Minimum fastener penetration thru bottom of support, 3/16". The FLAMCO "Off -Ridge Vent" shall be installed in compliance with the installation method listed in this report and applicable code sections of FBC 7th Edition (2020). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17.0 Evaluation Reference Data: 17.1 ASTM E330-02 Uniform Static Air Pressure Difference Test By Fenestration Testing Laboratory, Inc. (FTL) (FBC Organization nTST ID: 1657) Project #16-6647, Lab #9124, Dated: 11/09/16 17.2 Quality Assurance By Keystone Certifications, Inc. (FBC Organization #: QUA 1824) Licensee #440 17.3 Engineering Analysis By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 17.4 Certification of Independence By lames L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) SPecleglty Structural Enginesering CBUCK, Inc. Certificate of Authorization #8064 Installation Method FLAMCO "Off -Ridge Vent" Roof Vent '_114� "Off -Ridge Vent" (for Tile Roofs) Isometric View "Off -Ridge Vent" (for Shingle Roofs) Isometric View 1" from Edge 4" o.c. Typical, Maximum Fastener is 11 Gauge Galvanized Ring Shank Roofing Nail 'E Flange Top Plan View (Typical Fastening Pattern) (Not to Scale)