FL25623-R2
Revision
2020
Approved
Extreme Metal Fabricators, LLC
2160 SW Perna Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Richard McKuhen
flvalidati(;n@ydhoo.com
Roofing
Metal Roofing
FvaluaUon Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-B1377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections From the Code
FL25621 R2 CCI 26ga SnapMax plywood.pdf
Standard
TAS 100
TAS 125
UL 580
Year
1995
2003
2006
Product Approval Method
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approva{
Date Approved
Summary of Products
12/16/2020
12/17/2020
12/26/2020
02/09/2021
I FL #
Model, Number or Name
I Description I
125621.1
01: 26ga SnapMax on Plywood
-- ............ _.
26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
1 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL25621 R2 II 26ga SnapMax plywood.pdf i
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
I Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.25
Evaluation Reports
Other: Refer to evaluation report I
FL25621 R2 AF 26ga SnapMax plywood.pdf
j
Created by Independent Third Party: Yes
25621.2
02: 032 Aluminum SnapMax on I Nominally 0,032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood I on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-78.5
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 032 SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.3 03: 032 Aluminum 12" SnapMax on j Nominally 0.032" aluminum (or thicker) SnapMax 1,0" nail strip
Plywood I
1 with 12" coverage on 15/32" (min) plywood or 3/4" wood plank
Limits of Use ! installation Instructions
Approved for use in HVHZ: No ! FL25621 R2 II 032 SnapMax 12in Plywood.pdf
Approved for use outside HVHZ: Yes I Verified By; David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure. +N/A/-69.25 j Evaluation Reports
Other: Refer to evaluation report ! FL25621 R2 AE 032 SnapMax 12in Plywood.pdf
Created by Independent Third Party: Yes
25621.4 04: 26ga SnapMax on Plywood 126ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No j FL25621 R2 II 269a SnapMax plywood D.pdf
Approved for use outside HVHZ: Yes f Verified By: David Eng, PE 81377
Impact Resistant: N/A rI Created by Independent Third Party: Yes
Design Pressure: +N/A/-121.75 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax pLywDDdl D.plff
Created by Independent Third Party: Yes
_ —
_ . .. .....................�_ _.
25621.5 05: 26ga SnapMax on Plywood HVHZ ( 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
1 ; 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-176
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 269a SnapMax oaywood HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL2-5621 R2 AE 26ga SnapMax plywood HVH7.pdf
Created by Independent Third Party: Yes
125621.6 06: 24ga SnapMax on Plywood 1 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
j 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: Refer to evaluation report
25621.7 C7: 032 Aluminum SnapMax on
Plywood
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL25621 R2 II 249a SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 24ga SnapMax plywood.pdf
Created by Independent Third Party: Yes
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15132" (min) plywood or 3/4" wood plank
— —. _. _. _. _.. _.. _. _. _.... .... �.......... ...... ...... ...................... ...
Installation Instructions
FL25621 R2 II 032 SnapMax plywood d.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168,5
Other: Refer to evaluation report
25621.8 08: 032 Aluminum SnapMax on
Plywood HVHZ
------------
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-175
Other: Refer to evaluation report
25621.9 1 09: 26ga 19" TopMax on Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5
Other: Refer to evaluation report
25621.10 10: 032 Aluminum TopMax on
plywood HVHZ
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-179.5
Other: Refer to evaluation report
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax plywood d.pdF
Created by Independent Third Party: Yes
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Installation Instructions
FL25621 R2 II 032 SnapMax plywood HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax plywood HVHZ,pdf
Created by Independent Third Party: Yes
269a (min) TopMax 1.5" nail strip with 19" coverage on 15/32"
(min) plywood or 3/4" (min) wood plank
Installation Instructions
FL25621 R2 II 26ga TopMax 19in plywo d.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 26ga TopMax 19in plywood.pdf
Created by Independent Third Party: Yes
Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Installation Instructions
FL25621 R2 II 032 TopMax plywood HVHZ.pdf
Verified By: David Eng, PF B1377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
i 251 5Z1.11
11: 24ga TopMax on Plywood HVHZ
24ga (min) TopMax 1.5" nail strip on 15/32" (min) plywood or I
3/4" (min) wood plank
i
I Limits of Use
--
Installation Instructions
Approved for use in HVHZ: Yes
FL25621 R2 II 249a TopMax plywood HVHZ,pdf
Approved for use outside HVHZ: Yes
i
Verified By: David Eng, PE 81377 I
Impact Resistant: N/A
Created by Independent Third Party; Yes
Design Pressure: +N/A/-153.5
Evaluation Reports
I Other: Refer to evaluation report
FL25621 R2 AE 24ga TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621A2 12: 24ga 19" TopMax on Plywood
HVHZ
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116,25
Other: Refer to evaluation report
24ga (min) TopMax 1.5' nail strip with 19" coverage on 15/32"
(min) plywood or 3/4" (min) wood plank
._.,-.- .........................
Installation Instructions
FL25621 R2 It 24ga TopMax 19in plywood HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AL 24ga TopMax 19in plywood HVHZ .pdf
Created by Independent Third Party: Yes
25621.13 13: 032 Aluminum 19" TopMax on Nominally 0,032" aluminum (or thicker) TopMax 1.5" nail strip
plywood HVHZ with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood
plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL25621 R2 II 032 TopMax 191n plywood HVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A I Created by Independent Third Party: Yes
Design Pressure: +N/A/-166,75 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AF 032 TopMax 19in plywood HVHZ.pdf
Created by Independent Third Party: Yes
0
Contact Us 2601 Blair Stone Road, Tallahassee FL M99 Phone: 850-487-1824
The State of Florida is an RA/EEO employer. Lopes ht 2007-2013 State of Florida.:; Privacy 5tatemert :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are punlic records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395. Pursuant to Section 455.275(1),
Honda Statutes, effeLttve October 1, 2012, licensees licensed under Chapter 455, F.S. must provlde the Department with an email address If they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made avaiiable to the public. To determine if you are a licensee under Chapter 45S, ES., please click here .
Product Approval Accepts:
® Ed
Credit
Safe
securitrn��F�rx�cs' .
f
MAX
032 Aluminum (min) -MAX over 15/32" (min)
plywood
Extreme Metal Fabricators
2160 SW Poma Dr I Palm City FL 34990
Product Description
Nailstrip, snoplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
Nominally 0.032" aluminum or thicker
Fastener
#10 x 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
AN-- www_TimberLakeCove_com
.��ti1411111l11/�
MAX
FL2S621.02-R2
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required -
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code_
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 1" fastener at 6" o.c. along nail strip WITH sealant: 78.5 PSF
For Method A, use continuous 3/16" bead of Bostik 915 sealant or similar.
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre -punched slots.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D8133.02-450-18, as referenced in FL 17022.06-R7.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it hove a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David ring, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product_
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based an this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Instaliation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
MAX
FL25621.02-h2
Instructions:
Select the appropriate load table that applies to the
structure in question_
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency_
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A
FEtAALE LEG SNAPS
ONM MALE LE-�
�-- sEAi...ANT AF3PL IED TO
EASE OF ?:SALE LEG
#10FA5TENER
AT6"0G
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gablelhip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
, IG%OF LEAST Hogop a oipjENSION ORO,A W ICHEVER * SMALLER. GUT H07'
LESS THM EITHER 0, OF LEAST HORIZONTAL DIMENSION OR 3FT Io."
OR AS OETE.W&CD 3Y OCSiGN OR OTHER APPLICABLE COM.
ROOF ZONES FOR GENERIC BUILDING
NR: NOT RATED
CONSULT DESIGN
PROFESSIONAL AS
NECESSARY
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gablelhip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
i
a
FL25621.02: 032 Sna
Max on 15132" plywood
FL25621.02: 032 Sna Max on 15132" plywood
Wind
105
110 120
130
140
150 160 170 180 190 200
Wind
105
110 120 130 140 150 160 170 180 190 200
Zone 1:
A
A A
A
A
A A A A A
Zone 1:
A
A A A A A
Zone 2:
A
A A
A
A
A A
Zone 2:
A
A A -
Zone 3:
A
A A
A
A
A ^
Zone 3:
A
A -
Use this load table for structures which meet the following criteria:
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
Have a mean Roof Height of 30 feet or less
FL25621.02: 032 Sna Max on 15132" plvwood
FL25621.02: 032 Sna Max on 15132" ply&ood
Wind 105 110 120 130 140 150 160 170 180 190 200
Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A
Zone 1: A A A A A A A
Zone 2: A A A A A A A A
Zone 2: A A A A
Zone 3. A A A A A A
Zone 3: A A A -
Timberlake Cove, LLC David E Eng, PE Client: Extreme Metal Fabricators
1317 Edgewater Dr Ste 2339 FL PE Lic. No. 81377 Project. FPA Correction
Orlando, FL, 32804 FL CA Lic. No. 33344 Date; 2 June 2021
david,eno0timbeflakeeove.com Page 1 of 1
Notice of Correction to FL 25621
Background:
Extreme Metal Fabricators, operating at 2120 SW Poma Drive Palm City FL, maintains
a number of Florida Product Approvals (FPAs) for metal roof panel systems distributed
throughout the state of Florida. In revising these FPAs for the 2020 Florida Building
Code, client engaged Timberlake Cove to prepare evaluation reports for the new
building code.
Based on feedback from Client and after further review of the supporting
documentation, Timberlake Cove identified an error in four FPAs, 25621.01, 25621.02,
25621.03, 25621.04. On page 2, these FPAs contain a line requiring fasteners to be
installed through the metal flange. This line was included in error, and should be
stricken from the FPA. See illustration below- Corrected evaluation reports are being
prepared for submission to the Florida Building Commission.
Underlayment: Comply with meal building code or FSC I507.1.1 where raquired
SIOPe_ Comply with local building code or FSC 1307.4-2 where required
Re -Roofing: This pond may be inatalled over o single loyar of .mating sfiingles as Parm3tted
by Incoi building code or FSC 1511, provided the ekisting roof meets the conditions required by
the opp I icoble code.
Maximum Allowable loads S installation Requirements:
Method A: Tt1Q ]Ll^ to stoner at 6" �,.c_ n lang ne iI rT ri a: not VSF
g1,R x-i"-fastener ar G" o-c-.alone nail stria WFT ti s vlontc v7_aS Pam,_
For Method B. use contin aous 3116" heod of gosilk 913 sealant or s.m r.
A factor of safety of 2 has been oppiiad,
Technical Documentation:
This product has been tested to the UL 390 standard by Arehirecturol Testing (now Intertek
Testing, TST-1527), report p0133.01-050-]&, as referenced in EL 17022.05-R7.
_Correction Statement:
The SnapMax metal roofing product distributed by Extreme Metal Fabricators under FL
25621.01, 25621.02�_25621.03, 25621.04. does NOT require fasteners to be
installed through_the metal flange. Fasteners may be installed through the ore-
unched slots.
Please contact David Eng at David. Eng(a-)TimberlakeCove.com for further discussion as
needed,
This item has been digitally signed and
��1� E. sealed by D.E. Eng, PE, on the date
Q - �tC.l lSF [; indicated. Printed copies of this document
are not considered signed and sealed and
the signature must be verified on any
No. 81377 _ electronic copies
-U * - David Eng, PE
� � �. ��r ei3bM%i9retlMUxA6EEnq
:� ccr,_-ti �Timberlake Cove, LLC
`0 . STATE OFAPE Lic. No- 813771 CA Lic. No: 33344
"�'ss!dNAt_ EN
rrllll►t
Timbarlake
Cove u