HomeMy WebLinkAboutGENERATOR PAD DETAILEXISTING POLE MOUNTED TRANSFORMERS EXISTING OVERHEAD UTILITY DROP NEW RACK WITH ATS AND EXISTING CONTROL CABINET EXISTING UTILITY POLE WITH METER CAN EXISTING VAULT EXISTING WET WELL EXISTING CHAIN LINK FENCE EXISTING CONCRETE PAD 3'-0" NEW GENERATOR AND PAD 09/15/2021 2 OF 2GENERATOR SITEPLAN, DETAILS &NOTESDATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911DATEREVISIONMARKDATE: SHEET E-210/27/20201REVISED PER ST. LUCY COUNTY BUILDING REVIEW1" = 10'-0" 2 ENLARGED GENERATOR PLAN N W S E GENERATOR ANCHORING ELECTRICAL GENERAL NOTES: 1.THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. 2.THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2017). 3.ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. 4.THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. 5.PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. 6.ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. 7.DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW EXACT LOCATIONS OF DEVICES AND EQUIPMENT. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. 8.GROUNDING PER NEC ARTICLE 250. 9.INSTALL LOAD CENTERS AND DISCONNECTS SO THAT AT LEAST 3 1/2FEET OF WORKING SPACE CAN BE MAINTAINED PER NEC 110.26. 10.ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS WHERE APPLICABLE. 11.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 12.PROVIDE FAULT CURRENT MARKER PER NEC 110.24 AND ARC-FLASH DECALS PER NEC 110.16. 13.EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. ALL COMPONENTS OF THE ELECTRICAL SYSTEM LOCATED OUTDOORS OR INDOORS WHERE EXPOSED TO SIGNIFICANT MOISTURE SHALL BE WEATHERPROOF, NEMA 3R, AS A MINIMUM INDICATED ON THE CONTRACT DRAWINGS OR NOT. 14.PROVIDE TYPED PANEL DIRECTORIES FOR ALL NEW PANELBOARDS, AND EXISTING PANELBOARDS AFFECTED BY THIS PROJECT. DIRECTORIES SHALL REFLECT PROJECT AS-BUILT CONDITIONS FOR ALL BRANCH CIRCUITS. DIRECTORIES SHALL INCLUDE WHERE EACH PANEL IS FED FROM. ADDITIONALLY, EACH BRANCH CIRCUIT LOAD DESCRIPTION SHALL INCLUDE THE ROOM NUMBER(S) FOR EACH LOAD SERVICE. ROOM NUMBERS SHALL BE BASED ON ACTUAL ROOM SIGNAGE INSTALLED IN FIELD. COORDINATE EXACT ROOM NUMBERS WITH A/E AND OWNER PRIOR TO COMPLETION OF PANEL DIRECTORIES. 15.PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS ON EACH SWITCHBOARD, SWITCHGEAR, DISTRIBUTION PANEL, PANELBOARD, MOTOR CONTROL CENTER, SAFETY SWITCH, ENCLOSED CIRCUIT BREAKER, CABINET, STEP-DOWN TRANSFORMER, TRANSFER SWITCH , ETC., AND ANY OTHER MAJOR COMPONENT OF THE ELECTRICAL SYSTEM. 16.PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS FOR EACH DISTRIBUTION BREAKER OR BRANCH CIRCUIT BREAKER IN SWITCHGEAR, SWITCHBOARDS, MOTOR CONTROL CENTERS AND OTHER DISTRIBUTION EQUIPMENT. NAME TAG SHALL INCLUDE LOAD DESCRIPTION AND ROOM NUMBER FOR EACH LOAD SERVICE. 17.PROVIDE LABELS ON THE INSIDE OF EACH DEVICE COVER PLATE, IDENTIFYING THE PANES(S)/CIRCUIT NUMBERS(S). 18.PROVIDE NEATLY, HANDWRITTEN IDENTIFICATION ON THE EXTERIOR COVER OF ALL JUNCTION AND PULL BOXES, WIREWAYS. IDENTIFYING THE PANEL(S)/CIRCUIT NUMBERS(S) CONTAINED WITHIN. TOP VIEW LEFT ELEVATION FRONT ELEVATION DRILL DRILL 1/4" DEEPER THAN ANCHOR EMBEDMENT CLEAN DRIVE TIGHTEN 3-5 X DRILL BIT SIZE: 1/2"TIGHTENING TORQUE: 45ft.lbs. MIN. ANCHOR EMBEDMENT: 2-1/2" 1/4" MIN.88" 38" 8" MIN. 38"88" NOTE: 1.THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15 IS RECOMMENDED. 2.ANCHOR BOLTS TO BE 3/8"DIA.x3-3/4"LONG UNLESS OTHERWISE NOTED. 1/2" = 1'-0" 3 GENERATOR PAD DETAIL N.T.S. 1 OVERALL SITE PLAN N W S E 1 2 COMMENTS. PERMIT No. 2109-07111 NEW GENERATOR FOR:OCEAN RESORTS5101 N. HIGHWAY A1AFORT PIERCE, FL. 349491 F:\GENERATOR DRAWINGS\08-27-2021 Ocean Resorts Lift Station\08-27-2021 Ocean Resorts Lift Station.dwg, 10/27/2021 3:54:12 PM