HomeMy WebLinkAboutTermite Spray UES Project No: 3310.2100336.0000
A Universal Workorder No: 248252-1
Engineering Report Date: 10/18/2021
Sciences
Company
yrFRNATIONP
607 Northwest Commodity Cove,Port St.Lucie,FL 34986 -P:772-924-3575 -F:772-924-3580
In-Place Density Test Report
Client: John Wiliams UES Technician: Mark Rogers
2201 North 43rd Street Date Tested: 10/12/2021
Fort Pierce, FL 34946
Project: CMT Williams Residence 2201 N 43rd St
2201 N 43rd Street, Fort Pierce, St Lucie County, FL 34946
Type of Test:
Area Tested: 2201 N 43rd Street, Fort Pierce Field: ASTM D-6938 Nuclear Gauge Method
Material: Backfill Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0=Top of Fill
The tests below meet the 95%minimum compaction requirement.
Maximum Optimum Field Dry Field Soil Pass
Test Density Moisture Density Moisture Compaction or
No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail
1 Northeast corner of lot 0-1 ft 103.3 12.3 102.7 12.0 99 Pass
2 Southwest corner of lot 0-1 ft 103.3 12.3 102.9 11.8 100 Pass
3 Center of lot 0-1 ft 103.3 12.3 103.4 12.3 100 Pass
Remarks: Permit:SLC18110076
Reviewed By
GFA International,Inc
FBPE Registry No.4930
,�.vOENSF•OO�' Digitally signed by
No. 92555 Alexander Albandoz
STATE OF :&U Z
Date: 2021.10.18
O R
s �G�' 16:36:00 -04'00'
A%'E,.�`.
Alex Albandoz, P.E.
STATE OF FLORIDA
Professional Engineer No.92555
This item has been digitally signed and sealed by Alex Albandoz,
P.E.on the date adjacent to the seal.Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
'RECEIVED
OCT 2 12020
St.Lucie County
Permitting
To establish a mutual protection to Universal's clients;:the Public and ourselves,all reports are submitted as confidential property of our clients and
authorization for publication of statements,conclusion's or,,extracts from or regarding Universals reports is reserved pending our written approval.
'.'Page 1