Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Ci'EX\/� Project Name: PRESSLEY ADDITION Builder Name: Street: 2660 IROQUOIS AVENUE Permit Office: AUG `� City, State, Zip: FT. PIERCE, FL, Permit Number: 6 `021 Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(F[ofi6aLobaatt q���rrnittin 1. New construction or existing Addition 10. Wall Types(232.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, ExterioR=4.1 232.00 ft2 b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types(198.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 198.00 ft2 6. Conditioned floor area above grade (ftz) 198 b. N/A R= ftZ Conditioned floor area below grade (ft2) 0 c. N/A R= ft 7. Windows(46.2 sqft.) Description Area 12. Ducts, location & insulation level R ftZ a. U-Factor: Sgl, U=0.58 46.17 ftZ a. SHGC: SHGC=0.24 b. b. U-Factor: N/A ftZ C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ftZ a. Central Unit 9.0 SEER:18.00 SHGC: Area Weighted Average Overhang Depth: 1.480 ft Area Weighted Average SHGC: 0.240 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 9.0 HSPF:9.00 U-Factor:(AVG) N/A N/A ftZ SHGC(AVG): N/A 15. Hot Water Systems -None required 9. Floor Types Insulation Area Z a. zu@ Cap: N/A a. Slab -On -Grade Edge Insulation R= 0.0 198.00 ft ftZ b. Conservation features c. N/A R= 16. Credits None Glass/Floor Area:0.233 Total Proposed Modified Loads: 6.11 PASS Total Baseline Loads: 8.66 I hereby certify that the plans and specifications covered by Review of the plans and . OtE SIP this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance' with the Florida Energy Code. 'r"'�s `' r```• ". PREPARED BY: Before construction is completed ,_> this building will be inspected for DATE: 8-24-20 1 compliance with Section 553.908 Florida Statutes. i! ,t I hereby certify that this buiViig,s design d, is' complianceG'p�with the Florida Energy Co OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Proposed Qn of NAN exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 8/24/2021 10:59:30 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PRESSLEY ADDITION Building Type: User Bedrooms: 0 Owner: ConditionedArea: 198 Total Stories: 1 BuilderName: Worst Case: No Permit Office: RotateAngle: 0 Jurisdiction: Cross Ventilation: No FamilyType: Detached Whole House Fan: No New/Existing: Addition Terrain: Suburban YearConstruct: Shielding: Suburban Comment: Addresstype: StreetAddress Lot#: — Block/Su bDivision: -- PlatBook: — Street: 2660 IROQUOIS AVENUE County: St. Lucie City, State, Zip: FT. PIERCE, FL, CLIMATE Design Location Design Temp Tmy Site 97.5% 2.5% Int Design Temp Heating Design Dailytemp Winter Summer DegreeDays Moisture Range _FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 198 1584 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated —1 ENLCOSED PORCH 198 1584 No Yes Yes Yes FLOORS (Total Exposed Area = 198 sq.ft.) # FloorType Space Exposed Perim PerimeterR-Value Area U-Factor JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins ENLCOSED PORCH 29 0 198 ft 0.473 — 0.00 1.00 0.00 ROOF V# Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 209 ft2 0 ftz Medium N 0.6 No 0.9 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 198 ft2 N N CEILING (Total Exposed Area = 198 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type 1 UnderAttic(Vented) ENLCOSED PORCH 30.0 Blown 198.0ft2 0.053 0.10 Wood 8/24/2021 10:59:30 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 232 sq.ft.) V# Adjacent Ornt To Wall Type Cavity Width Space R-Value Ft In Height Area U- Sheath Frm. Solar Below Ft In sq.ft. Factor R-Value Frac. Absor. Grade -1 _2 N Exterior Conc. Blk - Ext Ins ENLCOSED PORCH 4.1 11.0 0 E Exterior Conc. Blk- Ext Ins ENLCOSED PORCH 4.1 18.0 0 8.0 0 88.0 0.131 0 0 0.60 0 % 8.0 0 144.0 0.131 0 0 0.60 0 % WINDOWS (Total Exposed Area = 46 sq.ft.) V# Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area ----Overhang---- Depth Separation InteriorShade Screening -1 N 1 Metal Low-ESingle 2 E 2 Metal Low-ESingle Yes 0.58 0.24 Y N 34.2ft2 Yes 0.58 0.24 Y N 12.0ft2 2.0 ft 0 in 1.0 ft5 in None None 0.0 ft 0 in 0.0 ft0 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00025 132 7.24 13.60 0.0902 5.0 All MASS # Mass Type Area Thickness Furniture Fraction Space 1 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 ENLCOSED PORCH HEATING SYSTEM # System Type/FI.Addition Subtype/Speed AHRI# Efficiency Capacity----GeothermalHeatPump--- Ducts Block kBtu/hr Entry Power Volt Current -1 Electric Heat Pump/Existing/co Split/Single HSPF: 9.00 9.0 0.00 0.00 0.00 sys#0 1 COOLING SYSTEM # System Type/FI.Addition Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit/Existing/co Split/Single SEER:18.0 9.0 0 0.70 Ductless 1 HOT WATER SYSTEM # SystemType Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipelength Recirculation RecircControl Loop Branch Pump DWHR System Type length length power Facilities Equal DWHR Other Credits Connected Flow Eff DUCTS VDuct---------Supply--------- # Location R-Value Area --------Return-------- Location R-Value Area LeakageType Air CFM 25 CFM 25 HVAC # Handler TOT OUT QN RLF Heat Cool 8/24/2021 10:59:30 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ProgramableThermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [I Apr []May [ ] Jun []Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [X] Apr [ ] May [ ] Jun []Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 AM 65 65 65 65 65 65 65 68 68 68 68 68 _Heating(WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 8/24/2021 10:59:30 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA" Project Name: PRESSLEY ADDITION Builder Name: Street: 2660 IROQUOIS AVENUE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: v Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriorthermal envelope insulation forframed walls shall be installed in substantial contact and continuous alignmentwith the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floorframing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exteriorwalls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exteriorwall and tubs shall separate them from the showers and tubs. be insulated. Electrical/phonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 8/24/2021 10:59:30 AM EnergyGauge® USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 71 The lower the EnergyPerformance Index, the more efficient the home. 2660 IROQUOIS AVENUE,FT. PIERCE,FL, 1. New construction or existing Addition 10. Wall Types(232.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, ExterioR=4.1 232.00 ft2 b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(198.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 198.00 ft2 6. Conditioned floor area above grade (ft2) 198 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft 7. Windows"* Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=0.58 46.17 ft2 a. SHGC: SHGC=0.24 b. b. U-Factor: N/A ft2 C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 9.0 SEER:18.00 SHGC: Area Weighted Average Overhang Depth: 1.480 ft Area Weighted Average SHGC: 0.240 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 9.0 HSPF:9.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. ot Systems -None required 9. Floor Types Insulation Area 2 198.00 ft a. 2U�Water Cap: N/A a. Slab -On -Grade Edge Insulation R= 0.0 b. R= ft2 b. Conservation features N/A 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above a rgy saving features which will be installed (or exceeded) in this home before final inspe to Otherwise, anew EPL Display Card will be completed based on installed Code co lia t feature . Builder Signature: Date: T/ Z Address of New Home: 2660 IROQUOIS AVENUE City/FL Zip: FT. PIERCE,FL, "Note: This is not a Building Energy Rating. It your Inaex is below tu, your nome may quaiiry ror energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/24/2021 10:59:30 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1