Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SINGLE HUNGComments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated. By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By MI Windows and Doors 650 West Market Street. Gratz, PA 17030 (717) $65-3300 Ext 2560 bsitlinger@miwd.com Brent Sitiinger bsitlinger@miwd.com Windows Single Hung Certification Mark or Listing Contractor C00 American Architectural Manufacturers Association Steven M. Urich, PE 5 validation Checklist - Hardcopy Received Standardyear AAMA 506 2016 AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/1.5.2/A440 2011 Product Approval Method Method 1`Option A Date Submitted 11/17/2020 Date Validated 11/17/2020 Date Pending FBC Approval fiHnc•/Iwwwflnririahiiileiinn nm/nr/nr ann d1i acnx9nnram=wC'FVX0vAr7ntr11C�rnriC]i7RRP�iSnf3%7YtRRnrKX�i1 SC( VchflPhl SnXTa�a%�rl%Rr1 114 617/2021 Florida Building Code Online l ,FL17499 R8 AE 51437 -pdf Created by independent Third Party: Yes 17499.6 1185 SH Limits of Use .Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-63 Other: R PG50 52x62 Fin, Flange, and Finless Frame, Insulated Glass Certification Agency Certificate Fi17499 R8 C CAC A q1 812 1711 08-106-12-RO 185 5H(DZZZn)•pdf Quality Assurance Contract Expiration Date 07127/2023 Installation Instructions FL17499 R8 II 0803379,-p_d{ Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R8 AE 514373.pdf Created. by Independent Third Party: Yes i- 17499.7 185.5H 52x62 Fin, Flange, and Flnless Frame, Insulating Lami Glass Limits of Use Certification Agency Certificate FL17499 R8 C CAC APC(17813)y 711 04-106-12-R0 185 Approved for use in HVHZ: No Approved for use.outside HVHZ: Yes ga( 727 3),pd Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure:+50/-63 07/27/2023 Other: R-PG50 a Installation Instructions FL17499 R8 II 08-03381 odf" Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 R8 AE EL4375 4df Created by Independent Third Party: Yes 17499.8, 1185 $H Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-70 Other: R-PG60; Missile Level D, Wind Zone 3. 17499.9 1 185 SH Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes impact Resistant: Yes Design. Pressure: +55/-55 Other: R-PG55, Missile Level D, Wind Zone 3. Glass to be bedded in Pecora 896 sealant. 36x72 Fin, Flange, Finless.frame, Insulated Glass Certification Agency Certificate FL17499 R8 C CAC APCf17816)1711 07-106=12-R2 185 5(9 1+p f Quality Assurance Contract Expiration Date 06/14/2023 Installation Instructions FL17499 R8 II 0$-03380.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499, R8 AE 514374 drdff Created by Independent Third Party. Yes 52x72 Fin/Flange Frame IG/SG Impact Single Hung Certification Agency Certificate FL17495 R8 C CAC APCL13275 -1U &l(10082 .ndf FL17499 118 C CAC APC (132 6)18S SH {10 823 _pdf FL17499 R8 C CAC APC lUIL77J 118 H (100823 _pdf FL17499 R8 C CAC APC 1( 3291) 185 H 1 082 _pdf Quality Assurance Contract Expiration Date 10/08/2023 Installation Instructions Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes. Evaluation Reports PLI7499 R8 AE 513320E-1.W Created by Independent Third Party: Yes 17449.10 185 SH 52x84 Fin/Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate FL17499 R8 C CAC APC l 32 3 185 S(.100923)_pdf Approved for use in HVHZ: NO Approved for use outside HVHZ: Yes FL17499 R8 C CAC APC ( 31 264) 185 SH (10 3 j& Impact Resistant:.No FL17499 7499 R8 C CAC 'APC (13265} 1 5 S 10p923),p FL17499 R8 C CAC APCf133621 1 5 0 3 af Design Pressure: +60/-60 Quality Assurance Contract Expiration Date Other: R-PG60 10/09/2023 Installation Instructions FL17499 R8 II 08-0254681.WE Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports F1-17499 R8 AE 513322E-2:pdf Created by Independent Third Party: Yes 17499.11 185Triple SH ilix72 Fin Frame IG/SG Single Hung 110x72.Flange Frame IG/SG Single Hung hitnwilvxawflnriAahniidinn nminr/nr nnn rfti acnr.9nnram-w(.FVX(3wf )ntCllr bvihi7FRPhRf1(:%X.gAA7wKXul ARS(` , hnphnnXTacn%�rt0/., WA NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE, 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING ANDMASONRYOPENING IS THE 'RESPONSIBILITY OF THE ARCHITECT DR ENGINEER OF RECORD. 3.. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4: WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1.-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS: ANCHORS SHALL BE'SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE: WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 9, SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS, 10. 'WIND LOAD DURATION FACTOR Cd-L6. WAS USED FOR WOOD ANCHOR.. CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063-T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE GLAZING DETAIL SHEET 2. 13, APPROVED IMPACT PROTECTIVE SYSTEM 1S NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS, 14, FOR. ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE-. LOCATE. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS, DESCRIPTION NOTES INSTALLATION DETAILS AMSMS 15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE 06 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16, FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR,2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE., LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS: 17, FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH ,SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 19. ALL FASTENERS TO BE CORROSION RESISTANT. 20, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED- BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G-0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI, C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm-ZOOOPSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-75 FU=3OKSI ,048" THICK MINIMUM WINDOW AND DOORS; LLC. 650 WEST MARKET STREET GRATZ, 'PA 17030 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" - IMPACT NOTES 10.32 08-03380 Ts"'-r I OF APPRSVFD- SIGNED: 02/26/2019 Lis R. L—.. P.E. -FL No.: 62514 71 Ff HE 36'- FRAME WIDTH — 10' MAX. D.C. 3 1/2" MAX. —^ i � 3 1/2' MAX. L 10" MAX O �T�—O.C. t 5/8` 4ME GHT I I 4 3 1/ MAX X I 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW FLANGE &FA4ESS INSTALATION 36" FRAME WIDTH 10' MAX. O.C. 3 1/2" MAX. 3 1/2" {MAX %%% 3 t/TA ( / 10 pj o MAX O.C. 71 5/8" FRAME HEIGHT 3 1%2 185ALUMINUMSINGLEHUNG WINDOWDESIGNER EXTERIOR VIEW FLANGES FINLESS INSTALLATION OESIGNPRESSURERATING IMPACTRATiNG +e�.W-7O.oPSF LARGE AND SMALL MISSILE IMPACT MISSILE LEVEL U. WInULunt) 36"X7158"UNiT SHOWN. OTHER S¢ESAPPROVEDASLONG AS FRAMEAREA DOES NOTEXCEED 17.SF7P NOTES: 1. SASH SRE: 34 15/16' X 36 1/16" 2. D.LO.: 33 1/4" X 32 7/16" omMTON I ah I �rnwm 5/8" 3/32" ANN .090" PVB BY EASTMAN 1/8' ANN 3/32" ANN GLAZING_ BEAD ALUMINUM V-6G3 BOX TYPE L SPACER SYSTEM 1/2" BRE APPROVED SILICONE GRAZING DETAIL MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ,PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" — IMPACT FLANGE & FINLESS ELEVATIONS YR: OWO N0. � OB-03360 E NTS ,pafE 01/17/19 —2 OF 10 L ROBERTO LONASP.H 193 WOODFORD RD LEMMUE M27023 434-m-o 04 �.—Sblmt®qP.mn- Luis R. Lomos P.E: FL No.: 62514 71 FF HE %'- 38" FRAME WIDTH q• I O.C. I� 12" MAXI - 4' MAX a^ nnez T- 1%- MAX G.C. O I �+ SME GHT t I j33E � j fi X II{� 36" ,FRAME WIDTH 4" MAX --{ 1^�i- 12� MAX 4" MAX 4" MAX I /6 Ofz" MAX O.C. 71 5/8" FRAME HEIGHT r----- I 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW DESIGNER EXTERIORWEW - svtmOR VIEW FW INSTALLA77ON FIN (NSTALIA770M DES(QN PRESSURE RA77N0 ' lMPACTRATMG 460.01-70.OPSF uRGEaNDSMau MISSILE UIPACT MISSILELEVEL D, WINDZONES 38•X715V UNTTSHOWN. OTHER SIZESAPPROVEDASLONG AS FRAMEAREA DOES NOT EXCEED 179 FR NOTES: 1. SASH SIZE: 34 15/16" X 36 1/16" 2, D.L.O.: 33 1/4" X 32 7/15" Rf - I MSCR m. 1 Mn 1 IP —M MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM .SINGLE HUNG WINDOW 36" X 72" - IMPACT FIN ELEVATIONS �B; GRG NO. — 08-03380 t NTS — 01/17/19. --3 OF 10 L ROBERTO LOMAS RE '432 WOOMRORD LEMSVUE. Nan= SIGNED: 0212612019 Luis R. Lomas P.E. FL No.: 62514 _ 1/2- MIN. EDGE DISTANCE WOOD FRAMINGF�SHIM OR 2X BUCKMETAL BY OTHERS1 1/4- MIN. STRUCTURE EMBEDMENT BY OTHERS APPROVEDSEALANT BEHIND FLANGESEALANT APPROVED BEHIND 'FLANGEWOOD SCREW EXTEROOR INTERIOR APPROVED SEALANT BEHIND FLANGE WOOD FRAMING OR 2X 'BUCK BY OTHERS SILL TO BE SET IN A BED OF APPROVED SEALANT 1/2- MIN, EDGE DISTANCE 1/4" MAX. k=j4 SHIM SPACE #10 SMS OR SELF DRILLING SCREW EXTERIOR INTERIOR APPROVED BEHIND 1/4" MAX. FLANGE T� SHIM SPACE SEALANT I VERTICAL CROSS SECTION WOODFRAMING OR2X9VCK WSTAU.ATION NOTES:, 1. INTERIOR AND EXTERIOR FINISHES, BY OTHER$ NOTSHOWNFDRCLAR?Y, 2 PEMMETERAND JOINT SEALANTBY OTHERS 718E ➢ESIGNED INACCORDANCE WRHASTM E2112 1 1/4` MIN EMBEDMENT T- 1/2- MIN EDGE DISTANCE #10 WOOD SCREW RE V-45 DMcRL T®N u 1/4" MAX. SHIM SPACE t INTERIOR WOOD FRAMING \ EX7ERIOR OR 2X BUCK` APPROVED BY 'OTHERS SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL WOOD FRAMWG OR2XBUCKINSTALLA77ON. 1/4" MAX. SHIM SPACE #10 SMS OR SELF DRILLING SCREWS AraRwm TO BE � ����' if-INILL A BED OF APPROVED SEALANT EXTERIOR METAL STRUCTURE .APPROVED BY OTHERS SEALANT 1/4" MAX.BEHIND FLANGE `SHIM SPACE JAMB INSTALLATION DETAIL METALSTRUCTIIREINSTALLATION SIGNED:0212&2018 MI WINDOW ALC. ND EOAWINDOW WET GRATZ, PA MARKET7v;V\�ENSF :11! VERTICAL GRASS SECTION S7AUCTUAEINSTALLATTON SERIES 185 ALUMINUM SINGWINDOW 36" X 72" - IMFLANGE �k' DMETAL INSTALLATION DRAWN:aLv A.R. OB-- S� NTS °ATE 01/17/19 OF 10LROBERTOL0.MASLuis R. Lomas P.E. 1422141"FORORDGiVASVS FL No.: 62514 2" MIN. EDGE DISTANCE �. CONCRETE/MASONRY HY OTHERS °•.a. °. , a' 1 1/4" MIN. OPTIONAL 1X BUCK EMBEDMENT - � ' °d'' SEE NOTES 3 - 7 _ ! SHEET 1 r • -�--� , 1/4" MAX: APPROVED SHIM SPACE SEALANT BEHIND FLANGE 3/1 B" TAPCON EXTERIOR INTERIOR �-- SILL TO BE SET IN.A BED OF APPROVED - '.I 1 APPROVED SEALANT SEALANT BEHIND FLANGE OPTIONAL 1X BUCK 1/4" MAX. SEE NOTE 3 - 7 .` SHIM SPACE SHEET 1 CONCRETE/MASONRY - n BY OTHERS ° • a ° ' VERTICAL CROSS SECTION CONCRETSMASONRY INSTALLATION 41 EY I OESLflIAIiDN DATE �PM�/E� 1 1/4" MIN. _. EMBEDMENT I V CONCRETE/MASONRY I '� BY OTHERS " b. . 3/16" TAPCON v , a•v• 2" . MIN. 1/4" MAX. SHIM SPACE INTERIOR AGE 'ANCE .a t1 EXTERIOR LIf , . _ ' APPROVED I_,. BE FLANGE BEHHINDIND - OPTIONAL 1X BUCK SEE NOTES 3 - 7 SHEET 1 JAMB INSTALLATI01V DETAIL CONCRETIRMASONRYAWALLATTON NOTES: 1. INTERIOR AND EXTERIOR FINISHES BYOTHER3, -NOTSHOWNFORCLARRY. 2. PERIMETER ANDJOINTSEW NTBYOTHERS TO BE .DESIGNED IN:ACCORDANCEWRHA6TMU112 MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" - IMPACT FLANGE INSTALLATION :DETAILS 5 OF 10 SIGNED. 0212612019 Luis R. Lomas P.E. FL No.- 62S14 1/2" MIN. EDGE DISTANCE 1/2" MIN, �I�--------^^^--- I I EDGE DISTANCE WOOD FRAMING 'DY OR 2x DUCK OTHERS 1 I/4" MIN.METAL EMgEDMEM BYRUCTURE OTHERS1/4" MAX. SPACE �SHIM BACKER ROD 1/4" MAXA� V�11' t& APPROVED SEALANT& SHIM SPACE BACKER ROD APPROVED SEALANT'#10 WOOD 10 SMS ORSCREW. SLF DRILLING SCREW EXTERIOR INTERfOR I EXTERIOR INTERIOR BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS SILL TO BE SET IN A BED OF APPROVED SEALANT r 1/4" MAX. BACKER ROD L SHIM SPACE & APPROVED T SEALANT VERTICAL CROSS SECTION VWW FRAMNG OR 2X SUCK INSTALLATION NOTES: I. fNTERIOR ANDEXTERIOR FINISHES, BYOTHERS, NOT SHOWN FoR cLARITY. 2. PERIMETERANDJOINT SEALANTBYOTNERSTOSE DESIGNED INACCOROANCE WITHASTME2112 OTHERS VERTICAL CROSS SECTION METAL STRUCTUREMISTALLA'RON SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE 1 1/4" MIN. EMBEDMENT 1/2" 1 MIN. EDGE DISTANCE #10 WOOD SCREW WOOD FRAMING EXTEAlOR OR 2X BUCK BACKER ROD BY OTHERS & APPROVED SEALANT JAMS INSTALLATION DETAIL WOOD FRAMNG OR 2X SUCK INSTALLiT 10N 1/4' MAX. I SHIM SPACE #10 SMS OR SELF DRILLING .SCREWS T- 1/2" MIN. EDGE DISTANCE wsoN DRC.MN PATE {.... 1/4- MAX. -I I SHIM SPACE INTERIOR INTERIOR LL L METAL 9ACKER ROD ExrERroR STRUCTURE & APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALIATION SIGNED: 0212612019 LLC. MI WINDOW00WESTAMDKET STREET E GRATZ, PA 17030 v,•�1 *• /�`•'0 SERIES 185 ALUMINUM SINGLE- HUNG WINDOW 36" X 7AL -IMPACT FINLESS INSTALLATION DETAILS • Si�E ,g, 888 AT OF L. 1432 WOOL 6 Luis R. Lomas P.E. FL No.; 62514 2' MIN. EDGE DISTANCE RY I D6°"�'�o" CONCRETE/MASONRY BY OTHERS 1 1/4" MIN. n EMBEDMENT i 1/4' MIN. OPTIONAL 1X BUCK ° " ' • ° SEE NOTES 3 - 7 — ---f- EMBEDMENT SHEET 1 '" 4 CONCRETE/MASONRY a 1/4".MAX. BY OTHERS J 1/4' MAX. _ - SHIM SPACE. - I SHIM SPACE BACKER' ROD & APPROVED SEALANT N ' d . `f) 3/16' TAPCON 3/16- TAPCO� i' � INTERIOR EXTERIOR INTERIOR SILL TO BE SET \ ! 1N A BED OF PACKER ROD I APPROVED SEALANT & APPROVED SEALANT OPTIONAL iX BUCK 1/4- MAX. SEE NOTE 3 - 7 !� -_� SHIM SPACE SHEET 1 CONCRFTE/MASONRY ° - EY OTHERS a, < VERTICAL CROSS SEC77ON CONCRETEANASONRYINSTALLARON MIN. EDGE EXTERIOR ; DISTANCE I 'a ti BACKER -ROD & APPROVED Ll J SEALANT I.A. � '.I OPTIONAL 1X BUCK SEE NOTES 3 - 7 SHEET 1 JAMB INSTALLATION DETAIL CONCRETFIMASONRY INSTALL1770N NOTES: 1. INTERIOR AND.EXTERLOR FINISHES, BYOTNERS, NOT SHOWN FORCLARITY. 2. PERIMETER AND JoWrSEALANTBYOTHERS TO BE DESIGNED INACCORDANCE WITHASTME2112 MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" - IMPACT FINLESS INSTALLATION DETAILS '19 1-7 OF 10 ?Towms P.E: 4DLEWSVR.LEAf0V 3. dbmespw--Pe— WPRO SIGNED: 02126,2019 Luis R. Lomas P.E. FL No.: 62514 APPROVED SEALANT BEHINDBEHIND FIN. 1 112' MIN. EMBEDMENT #6 WOOD WOOD SCREW i. / FRAMING BY OTHERS .�_._ 1/4" MAX. 1/4" MAX SHIM SPACE WOOD FRAMING SHIM SPACE 3/8" MIN gr BY OTHERS EDGE DISTANCE EXTERIOR � INTERIOR 3/8" MIN' EDGE DISTA.NC 46 WOOD SCREW APPROVED SEAIANi BEHIND FiN VERTICAL CROSS SECTION .WOOD FRAMING OR 2XBUCX INSTALLATION 1 1/2" MIN. EMBEDMENT INTERIOR 3 #6 WOOD SCREW' APPROVED EXTERIOR SEALANT -- BEHIND FIN 3/8" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WDOO FRAMING ORZX BUCK11US7AL[ATION NOTES: 1. INTERIOR AND EXTERfOR FWISHES, BYOIBERS, NOTSHOWN FOR CLARITY. 1/4` MAX 2.PERIMETERANDJOINTSE4LANTBYOTHERSTOSE SHIM SPACE DESIGNEOINACCORDANCEWRNASTWE2112 MI WINDOW AND DOORS, L 650 WEST MARKET STREET GRATZ, PA '17030 WOOD FRAMING SERIES 185 ALUMINUM SINGLE HUNG BY OTHERS 36" X 72" — IMPACT .FIN INSTALLATION DETAILS SIGNED. OZ2612019 Luis R. Lomas P.E. FL No.: 62514 , Rfl I DUCRPnON ' WEE I IRPRNM APPROVED SEALANT BEHIND FIN #6. SMS OR { METAL STRUCTURE SELF DRILLING - i rf BY OTHERS SCREW I ' I �� 1 M MAX, SHIM SPACE METAL STRUCTURE � 1/4" MAX SHIM SPADE 3/8" MIN JT BY OTHERS EDGE DISTANCE I INTERIOR #6 SMS OR SELF DRILLING SCREW EXTERIOR INTERIOR APPROVED ANT EXTERIOR BEHIND FIN 3/8" MIN EDGE DISTANCE JAMB INS7ALLATION DETAIL METAL STRUCTURE INSTALLATION NOS, 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, I� NOTSHOWNFORCLARRY. r_,....� 1/4" MAX SHIM 2.PFRIME7ERAMDJC7IN7'SEALANTBYOTHERSTOSE �^ .SPACE DESIGNEDNNACCORDANCEWITHASTME2112 SIGNED: O2/26/201 ^ 3/8-.MIN J-%/// , ��(j(jjj�� EDGE DISTANCE / � MI WINDOW AND DOORS, LLC. 650 �\ti\��tAflLpt/�i vJ'v\C@NS94P GWEST RATZ,MPAKET 17030RE� �/6 SMS OR �,//j METAL STRUCTURE SELF DRILLING BY OTHERS VERTICAL CROSS SECTION SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" — IMPACT SCREW 1 METAL STRUCTURE NSTALLATMN FIN INSTALLATION DETAILS EC""""L "_lI�. TAT OF L APPROVED DRAWN: Dwc ne, REV SEALANT BEHIND FIN - A:R• 08-03380 Luis R. Lomas P.E. FL No.:. 62514 2 3/16" 1 s/1s" 1 FINLESS FRAME HE4Q CM,18583 ALUMINUM 6088-T5.050' THICK ---T2 3/16" T—i— .. - 1 73/16" FLANGE FRAME. HEAD CM-18501 ALUMINVII.6063-TS.050"THICK 2 3/16' 2 5/16" FIN FRAME HEAD CM-18508 ' ALUMNUM 6063.78.050'7H1CK z s/16'• --1 2 13/1 FINLESS' FRAME SILL CM-18554 ALUMINUM 6063-T5:055'THICK 2 5/16- --I i 3 3/8" .fL FLANGE FRAMESILL CM-18502 ALUMINUM 6063•T6.CW T HICK — 2 5/16" ---f 1 3 3/4- FIN FRAME SELL CM•18509 ALUMINUM 6069.75.055"THICK 7 3/8'f - 2 3/16" L .L FINLESS FRAME JAMB CM-18513 ALUMINUM 6083-T5.050`THICK 2 ,:—. FLANGE FRAMEJAMB CM-16503 ALUMINUM 6063-T5,060"THICK --J 2 3/8" F 2 3/16- FIN FRAME JAh18 CM-18510 ALUMINIIM6063-T5.050"THICK I REV I OESMIPMN I p n I A RW I Fly MEETING RAIL CM-18504 ALUMINUM 608$-T6.055' T HICK 1 7/16" I 2 Fff SASH BOTTOM RAIL CM•18555 ALUMINUM 8083-75.050'77TICK -1 1 5/8" I 1 3� UF LOCK RAIUSTILE CM-18505. ALUMINUM 6063-T5-662'THICK 3jjjf� 8��''' 15/16- I T SASSHHSTILE cMa65DT ALUMINUM 6063-T5.050"THICK 1-.--{ 3/16.. G! AZJNG BEAD V-S63 RiGIDPVC.070"7HK%K MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030 SERIES 165 ALUMINUM SINGLE HUNG WINDOW 36" X- 72" - IMPACT COMPONENTS oRewu: 0wc No. A.R. 08-03380 scna NTS °A 01/17/19 s"�10 OF 10 SIGNED: 02/2612019 Luis R. Lomas. P.E. 'FL. No.. 62514