Loading...
HomeMy WebLinkAboutProject Information* wrightsofto Project Summary AHU 1 , QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM mmijEsiect intormation For. SCOTT AND NATALYARAMIST 159 OCEAN ESTATES DRIVE, -FORT PIERCE, FL i Notes: Job: Date: Jun 21, 2021 By: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 1 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11675 Btuh Structure 9334 Btuh Ducts 2338 Btuh Ducts 3513 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14013 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12204 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3468 Btuh Ducts 932 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1009 1009 Equipment latent load 4400 Btuh Volume (ft3) 10000 10090 Air changes/hour 0.30 0.15 Equipment Total Load (Sen+Lat) 16604 Btuh Equiv. AVF (cfm) 51 26 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018J1 AHRI ref Coil TEM4AOB18S21++TDR AH RI ref 8676071 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 3.8 kW Sensible cooling 13160 Btuh Heating output 112873 Btuh Latent cooling 5640 Btuh Temperature rise 19 OF Total cooling 18800 Btuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.74 Calculations approved byACCA to meet all requirements of Manual J -*- wrbahtsoft- FILE un-2 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 E:\Documnets\Wrightsoft WAC\RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N * wrightsoft° Project Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For. SCOTTAND NATALYARAMIST 159 OCEAN ESTATES DRIVE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Job: Date: Jun 21, 2021 By: Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29923 Btuh Structure 17918 Btuh Ducts 5994 Btuh Ducts 8580 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35918 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf load 0.95 25173 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3774 Btuh Ducts 2341 Btuh Central vent (0 cfm) 0 Btuh Heating cooling (none) Area (ft2) 1991 1991 Equipment latent load 6115 Btuh Volume (ft3) 19910 19910 Air changes/hour 0,'33 0.16 Equipment Total Load (Sen+Lat) 31289 Btuh Equiv. AVF (cfm) 109 54 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6036J 1 AHRI ref Coil TEM4AOC37S31++TDR AHRI ref 201763705 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 10.1 kW Sensible cooling 24640 Btuh Heating output 34384 Btuh Latent cooling 10560 Btuh Temperature rise 27 OF Total cooling 35200 Btuh Actual air flow 1 1173 cfm Actual air flow 1173 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -PW wrightsoft® 2021.1un-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 2 E:1DocumnetslWrightsoft WACIRAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right-JO Worksheet Job: AHU 1 Date: Jun 21, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466.6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area AHU 1 92.0 ft 10.0 ft 1009.0 ft2 M WIC 2 0 ft 10.0 ft ` heat/cool 8.0 x 11.0 ft 88.0 ft2 Ty Construction number U-value (Btuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 11 0 0 0 0 _.. 0 0 0 0 _____ _. 0 0 0 0 0 _'__.0 0 ----- 0 _.88 88 0 0 0 0 _.- ._ __ 0 0 0 0 _---___-_0 0 0 0 0 _-_ ___.0,_-_.___._0 0 _ -_,- 0 _ -ti8 0 0 0 0 -_._. _ __0, 0 0 0 ---,-_-0 0 0 0 0 0 --__ 0 140 --_.- Q 0 0 0 0 _. ___ -- _ 0 0 0 0 _._. _.___-0 6 0 0 0 __ _..._ ..0 0 - - _ 0 100 ------ 0 13Allocs 2 glazing,, clr lower 2 glazing, clr low-e 2 glazing, clrlow-e .2.glazing,.clr lQw:p- 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq,..clr lower__-- 13A4ocs 2 glazing, clrlow-e 2 glazing, clr low-e 2 glazing, clr low-e .2.glazing, clrlow-e-__. 13A4ocs 2.glazinq, cir low-e - 16X19-Md_ ---_,_ 22A-tph-_ -- 0.143 0.650 0.650 0.650 __-_-_0.650 0.143 0.650 0.650 -___0.650 0.143 0.650 0.650 0.650 _.__ .0.650 0.143 __-- 0.650 ._ ._ _0.408 1.358 n n n n _ n__ a a a __a - s s s s __s__ w w-- ; _ - 4.00 0.00 0.00 0.00 0.00 4.00 18.20 18.20 I- `0.00 4.00 18.20 18.20 0.00 ---0.00 I 4.00 --0.00. 1.59 38.02 T 2.19 0.00 0.00 0.00 0.00 2.19 31.52 32.65 _,-0.00 2.10 14.99 14.99 0.00 ___.-0.00 2.19 0.00 . 1.13 0.00 60 0 0 0 _ _. _0 260 12 18 _--0 ^ 400 9 54 0 __0 200 _ _- 0 __. _ 1009 1009 60 0 0 0 __--- __.. _0 230 1 1 _ - 0 337 9 54 0 ... ______0 200 -- 0 _----1009 92 240 0 0 0 -__ _-_._0 921 218 328 -_-0 3349 164 983 0 ____. __ 0 801 ---0 _-_ 1600 3498 131 0 0 0 ____ _ ___0 503 378 588 -_-.-0 737 135 810 0 ______.. A 438 --_- 0 ._ ._.1143 0 _ - ___-- - V)I -(' F - ----- --U 6 c)AED excursion 0 -1 Envelope loss/gain 10102 4862 140 99 12 a) Infiltration b) Room ventilation 1573 0 421 01 0 0 0 0 13 Internal gains: Occupants pGth230 Appliances/other 0 4050 0 300 Subtotal (lines 6 to 13) 11675 9334 140 399 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 20 6 38 0 0 0 0 11675 2338 0 0 0 9334 3513 200/6 380/6 0 0 01 140 28 0 0 0 399 150 Total room load Air required (cfm) 14013 627 12846 627 167 7 549 27 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. 41- wrightsoft- 2021-Jun-21 14:21:22 A&k '" " ' " ^ " Right -Suite® Universal 2021 21.0.02 RSUD8101 Page 1 E:\Documnets\Wrightsoft WACIRAMIST RESIDENCE.rup Calc = MJ8 Front Doorfaces: N -�- wrightsoft' Right-JO Worksheet AHU 1 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Jun 21, 2021 By- 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M BATH 26.0 ft 10.0 ft heat/cool 1.0 x 213.0 ft 213.0 ftz M TOILET 5.0 ft 10.0 ft heat/cool 5.0 x 5.0 ft 25.0 ftz Ty Construction number U-value (BtutVWF) Or HTM (Btuh/ftz) Area (ft2) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A flocs 2 glazing, clr:low-e 2 glazing, clr lowe 2 glazing, clr low-e 2.glazing, clr 1me - 13A-4ocs 2 glazing, clr lowe 2 glazing, clr lowe 2 glazing,, clr low-e 13A-4ocs 2 glazing, clrlowe 2 glazing,clr iowe 2 glazing, cir lowe .2glazing, clr_low-e._.___.---0.650__s__...____0.00_--_0.00_...._ 13A-4ocs 16X1az9 Otdclr low ey -- 22A tph ._... _- --. 0.143 0:650 0.650 0.650 _ ___0.650 0.143 0.650 0.650 0.650 0..143 0.650 0.650 0.650 0.143 -0'408 __- 1,358 n n n n _n_ e a a e s s s s w .. W -- 4.00 0.00 0.00 0.00 _0.00------ i 4.00 18.20 18.20 �-EO. 4.06 18.20 18.20 0.00 4.00 _ 0.00 1.59 _ 38.02 2.19 `. '0.00 0.00 0.00 2.19 31.52 32.65 --0.00 � 2:19 14.99 14.99 0.00 2.19 _ 0.00 . .1.13 _ - 0.00 -� 0 0 0 0 -9 170 12 0 0 0 0 0 158 1 0 0 90 0 0 0 0 --- 0 _. _213 _ _-26 0 0 0 0 633 218 0 ---__-0 360 0 0 0 0 0 0 0 346 378 0 -0 0 0 0 0 0 0 -�-.- 0 50 9 0 0 0 0 6 0 0 0 0 0 0 --_._.-.0 41 9 0 0 0 -- - 0 ___..., __25 - -- _ 5 0 0 0 0 0 0 0 - 164 164 0 0 --0 0 -- 0 _ _ -__ - 40 _.. _ 190 0 0 0 0 0 0 0 90 135 0 0 _0 0 0 -- --- -28. -- 0 ----__. _ Vff Vy I-{ C, _ _F -- - -_._---0 0 0 0 0.-______0.----tiU----_-_0-_---0_______.0 0 -- ---- 0 .-._ _ -_213 -- --213 ------0 197 0 0 0 0 --- 0 --- - . 241 - - -- 0 0 0 .__ -_.- 338 - 989 - -_ .-____.?5 -- 25 6 c)AED excursion -2 -1 Envelope loss/gain 1 2538 1160 558 252 12 a) Infiltration 1 b) Room ventilation 444 0 119 0 85 0 23 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 300 Subtotal (lines 6 to 13) 2982 1479 643 575 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 20% WA 0 0 0 2982 597 0 0 0 1479 557 20% 38% 0 0 0 643 129 0 0 0 575 21fi Total room load Air required (cfm) 3580 660 2035 99 1 772 1 35 791 39 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c � wr➢ghtsoft:- 2021Jun-Jun14:21:22 AP. Right -Suite® Universal 2021 21.0.02 RSUOB101 Page 2 E:1Documnets\Wrightsoft WAC%RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N - wrightsoft' Right-J® Worksheet Job: AHU 1 � Date: Jun 21, 2021 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-465-6796 Email: QUICKCALCS a(AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M WIC 1 8.0 ft 10.0 ft heat/cool 8.0 x 5.0 ft 40.0 ftz MASTER BEDROOM 34.0 ft 10.0 ft heat/cool 1.0 x 342.0 ft 342.0 ftz Ty Construction number U-value (Btuh/ftz-°F) Or HTM (Btuh/ft2) Area (ftz) or perimeter (ft) load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 A- 13A-flocs --' --' 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e low_e,-__ 13A4ocs 2 glazing, clr lower 2 lazi 13A-4ods clr low a-- 2 glazing, clr low-e 2 glazing, clrlow-e 2 glazing, clr low,e clrlowe._--..______ 13A-4ocs 2 Glazin4.. clr low-e - 10X19,M __._.___._ _ 22A tph 0.143 0.650 0.650 0.650 ._-____0.650 O'650 0.650 __-- 0.143 0.650 0.650 0.650 0.650 0.143 -----0:650 -__ 0.408 1.358 n- n n n ___n a a _sue s s s _-s _ w I w j -__ - 4.00 0.00 0:00 0.00 0.00, 4.00 18.20 - _ -_ 4.00 18.20 18.20 0.00 ___0 4.00 0.00 ____1.59 38.02 2.19 - 0.00. 0.00 0:00 _-0.00 2.2 31.52 T2. 9 14.99 14.99 0.00 __. �-0.00.__-,..-__.0 2.19 -_0_00 __ 113 0.00 0 0 . 0 0 ._.0 0 0 `-- 800 0 -- 0 0 0 0 0 0 0 0 0 - 0 0 0 ._..- 86 0 0 0 _ _ .-.__--. 0 0 0 0 0 0 .-__---- 0 0 0 -- 320 0 0 0 ___.__-0 0 0 0 0 0 0 --- _ _0 0 0 0 0 0 0 ------_-___0 0 0 0 0 0 0 0 _ _._ __-:0 0 0 0 --106 0 54 0 180 .----- 0 34 0 0 0 0 0 0 0 4224 0 983 0 ____ _ 0. 721 ._..-----0 542 1293 0 0 0 0 0 0 0 0 232 0 810 0 __ __0 394 ----- 0 .-__._..387 0 :.2.glazin9,,clr ILI----.---GGG __.. ..2glazing, 1W, _._7:� C__-, _: F -175 0 0 0 _ _--- .__0-____c0 0 --- 0 45 0 '- 160 0 54 0 180 _ __ .- _40 40 ..__ -.�0 -----_-40 8 F _ 304 -0 __-__.342-----342 342 _ . ------- _ -_.. 6 c)AED excursion .1 -6 Envelope loss/gain 688 2191 3963 1816 12 a) Infiltration 1 b) Room ventilation ' 137 0 37 0 581 0 156 0 13 Internal gains: Occupants @ I 230 Appliances/other, 0 0 300 0 0 2200 Subtotal (lines 6 to 13) 825 556 45441 4172 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct loads 20% 38% 0 0 0 825 165 0 0 0 556 209 20% 380/6 0 0 317 4861 974 0 0 123 4295 1617 Total room load Air required (cfm) I 990 1 441 765 371 1 5835 1 261 5912 289 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c -➢ rl- wr➢ghtsoTt- 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 3 E:1DocumnetslWrightsoft WACIRAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N wrightsoft Right-Jli Worksheet Job: AHU 1 Date: Jun 21, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name F posed wall Room height Room dimensions Room area LAUNDRYRM 15.0 ft 10.0 ft heaUcool 1.0 x 158.0 ft 158.0 ftz HALLWAY 4.0 ft 10.0 ft heat/cool 1.0 x 82.0 ft 82.0 ft2 Ty Construction number U-value (Btuh/ft-°F) Or HTM (Btuh/W) Area (ftz) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat I Cod Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 11 �._._ ...-.___ W --G C..._.. F _.._._ - 2.19 0.00 0.00 0.00 0.00 2.19 31.52 32.65 ._. 0.00 2.19 14.99 14.99 0.00 2.19 0.0 _1._13 0.00 60 0 0 0 _.. _ 0 90 0 18 --- 0 0 0 0 0 0 -- _0 0 -.158 _158 -- 60 0 0 0 ..___ 0 72 0 1 _ 0 0 0 0 0 .--._<0_.__._---.0.__ 0 -__ , 0 - 158 _ -15 ---- 240 0 0 0 ..___ .__. _ 0 288 0 328 __- ._ 0 0 0 0 0 0 -._ - 0 _. 251 --- 570 -- - -- - --- -- ----- -- - 13Adocs- -------'----'-0.143 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2.glazing,,.clr louvre__.__ 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing._clr low-e,-_ 13A4ocs 2 glazing, clrlowe 2 glazing, dr low-e 2,glazing, clr low-e _2 glazing, clr__low e.-__' 13AAocs 2 glazing, cir low-e_ _16X19 did- . _ mph 0.650 0.650 0.650 w.,_T__0.650 0.143 0.650 0.650 0.650 0143 0.650 0.650 0.650 -0.650 0.143 _ 0.650 0.408 -- _ 1.358 --...- n n n n _ _n_, a a a __ e - s s s s s-- w _ w_ _ - - -1--- 4.00' 0.00 0.00 0.00 _ _...0.00. 4.00 18.20 18.20 -� - 0.00 4.00 18.20 18.20 0.00 ___0.00._--0.00.___-_-0 4.00 ._ 0.00- 1.59 7 338.62 - 131 0 0 0 _ .-0 158 0 588 0 0 0 0 0 ....____ _.0 0 0 0 ._._ -_-- -0 20 0 0 0 _..--_ 0 20 _ 0 ---- 82 -- -82 0 0 0 0 -.._-_..___.0 0 0 0 ------ 20 0 0 0 _._--_-- 0 20 _ - 0 82 _------4 0 0 0 0 . _...._ _ 0- 0 0 0 .--- --0 80 0 0 0 80 _-_ - 0 _ _.._ 130 -----152 0 0 0 0 _.._ _ -_0. 0 0 0 --_-.-----0 44' 0 0 0 44 -_, 0 -- - ---0 0 0 0 0 _-__0 0 0 ^ 179 -__ -- 0 6 c) AED excursion 12 0 Envelope loss/gain 16T7 1067 442 180 12 a) Infiltration b) Room ventilation 256 0 69 0 68 0 18 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 350 0 0 0 Subtotal (lines 6 to 13) 1933 1486 511 198 14 15 Less external load Less transfer Redistribution Subtotal 1 Duct loads 20% 38% 0 0 70 2004 401 0 0 27 1513 570 20% 38% 0 0 -511 0 0 0 0 -198 0 0 Total room load Air required (cfm) 2405 108 2083I 102 0 1 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -FW wrv0t%tsoft- 2021-Jun-21 14:21:22 A&k Right -Suite@ UniveIrsal 2021 21.0.02 RSU08101 Page 4 E:1Documnets%Wrightsoft WACIRAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N -�- wrightsoft Right-MIlWorksheet AHU 1 1 QUICK CALCS, INC. i 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: I, 99 Fax 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: Jun 21, 2021 By: 1 2 3 4 5 Room name =ed wall Room height Room dimensions Room area PANTRY O ft 10.0 ft heat/cool 11.0 x 3.0 ft 33.0 ftz POWDER RM O ft 10.0 ft heat/cool 7.0 x 4.0 ft 28.0 ft= Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/2) Area (ft') or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool --_- - -- -- - -- 6 - --- 13A-4ocs 2 glazing, clr lowe 2 glazing, clr low-e 2 glazing, clrlowe 2 glazirg, clr lower___ 13A-4ocs 2 glazing, clr lowe 2 glazing, clr lowe glazinp,_clr lower-_ 13A-4ocs 2 glazing, clr lowe 2 glazing, clr low•e 2 glazing, clr low-e 2 glazing,_clrlowe.___ 13A4ocs 2,plazinp, iqlr lower 16X1.9 0td_. �_ __- -t - 0.143 0.650 0.650 0.650 ____0.650 0.143 0.650 0.650 __-0.650 0.143 0.650 0.650 0.650 _--_0.650 0.143 -.__ 0.650 __ .__0.408 1.358 n - n n n __n_ a a a ._e s s s s --s . w -w _ _ - . - - 4.00 0.00 0.00 0.00 ___. 0.00 4.00 18.20 I 1 18.20 .L 0,00 4.00, 18.20 18.20 0.00 ---_-_O.00. I 4.00 -- 0.00 - _ 1.59 r• 219 0.00 1 0.00 0.00 -_ 0.00 2.19 31.52 32.65 _---0.00 2.19 14.99 14.99 0:00 --__0.00 2.19 0.00 _ -1.13 0.00 0 0 0 0 _ ___ _.__ 0 0 0 0 ---_ 0 0 0 0 -_-..,_,..__0 0 0 0 _----_ 0 0 0 0 0 ----_.-.-0 0 ___--0 ____---..33 0 -- 0 0 0 0 -.__.._T0.-.__.._ 0 0 0 0 0 0 0 0 ._--- _0 0 0 - 0 0 0 0 _-0 0 0 0 _-�0 0 0 0 0 ___-._._-_o 0 0 0 0 0 0 --_-__--- -_0 0 0 0 0 0 0 0 -------- -__0 0 -----_-- 0 -.------_28 --- -28 0 0 0 0 .---- ____0 0 0 0 0 0 0 0. _._..__ _ 0 0 _-_- 0 ---- - --28 --� 0 0 0 0 0. _ __._ _.._0. 0 0 0 0 0 0 0 - -_--.. 0 0 0 0 0 0 0 0 . --.__ . 0 0 -___-- -- 0 -- .32 -- - - 0 V�J �-G _. -_ . VIJ Q____. F -- _0 _0 0 0 0 --.- _-0 0 --- 0 _ _33 33 0 0 0, 0 _ _ _.___..0 0 -__-0 - _ - ---- `r4 --- -0 _ - _---- 52 --- 0 _-- ----.- 37 ___0 --- - . -38.02 i _- - 6 c)AED excursion 0 -1 Envelope loss/gain 52 37 44 31 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ I 230 Appliances/other 0 0 0 0 0 1 400 Subtotal (lines 6 to 13) 1 52 37 44 431 14 15 Less extemal load Less transfer Redistribution Subtotal Ductloads 20% 38% 0 0 52 0 0 0 0 -37 0 0 20% 38%l 0 0 176 220 441 0 0 85 516 194 Total room load Air required (cfm) 0 0 0 01 264 12 711 35 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. cP. � wr➢grntsoTt� 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 5 `E:\Documnets\Wrightsoff HVAC\RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N - - wrightsofir Right-J® Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Jun 21, 2021 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area AHU 2 196.0 ft 10.0 ft 1991.0 ft2 KfrCHEN 15.0 ft 10.0 ft heat/cool 15.0 x 16.0 ft 240.0 ftz Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft) Area (ft-) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NOS Heat I Cool 6 , . wG W I-G F- 13A flocs--T 2 glazing, clrlow-e 2,glazing, clr Iowa 2 lazing, clr low-e ,2,glazmg, clr Iowa T 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e .2 glazing. cir low-e - 13A-4ocs 2'glazing, clr Iowa 2 glazing, clr lower 2 glazing,, clr low-e, .2 glazing,_clr Iowa ___ 13A4ocs 2 4lazinq, clr low-e_- 22A-tph -- 0.143 0.650 0.650 0.650 0650 0.143 0.650 0.650 - 0.650 0.143 M50 0.650 0.650 .0.650 0.143 - 0.650 '0.408 1.358 - n n n n _._n ` a a e� -e , s i s' . a, s s_:, vi , w _�. - -[ -4.00 18.20 18.20 18.20 _ 18.20 4.00 0.00 0.00 1820 4.00 0.00" 18.20 18.20 . 18.20. 4.00 18.20 1 59, 38.02 4 2.19 14.99 14.99 14.99 _14.99._ 2.19 0.00 0.00 _ 32.93 2.19 '.0.60 14.99 14.99 14.99 2.19 31.52 1' 13 0.00 r-__ : 600 • 9 18 108 _ _4$ 240 0 0 _-__-48 600 0 36 .191 96 520 18 --417---- 0 0 0, ,_ _w._w 192 0 0 164 328 1966 _. _-874 769 0 0 874 135 270 1619 _..___ _720 420 0 0 1581 607 0 540 2858 _._ ___1.439 1098 __� 567 .-_.. _2255 --0 0 0 0 -.._.___ ._0 0 0 0 0 0 0 _..__ ._0 0 0 0 _-_ 0_ 54 0 0 0 .__ . ___96 0 0 _.. _ 240 - -_15 0 0 0 _,_-- __ _0 0 0 0 0 216 0 0 0 1747 0 __ -_- 0 �._, 381, - 676 0 0 0 __... U. 0 0 0 118 0. 0 0 _ 1439. 0 _ 0 �_ _ _-272, ----- 0 _-2 27Z 0 36 ]91 96 502 2 --.: 1110 0 655 3470 1747 2010 _�-328 .- __3157 7453 __--_0 150 0 0 0 _-_ _ _96 0 -_ 0 ___ '240 - 240 _ ,1991 1991 - _ 1991 196 7 + 6 c) AM excursion 0 -34 Envelope loss/gain 26573 15021 2914 1795 12 a) Infiltration b) Room ventilation 3351 0 898 0 256 0 69 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 2000 0 0 300 Subtotal (lines 6 to 13) 29923 17918 3171 2164 14 15 Less external load Less transfer Redistribution Subtotal I Duct loads I 20% 48% 0 0 0 29923 5994 0 0 0 17918 8580 20% 480 0 0 188 3359 673 0 0 120 2283 1093 Total room load 1 Air required (cfm) 35918 1173 26498 1173 4032 132 3377 149 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Ad- 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 6 EADocumnets\WrightsoftWAC%RAMISTRESIDENCE.rup Cafe =MJ8 Front Door faces: N -�- wrightsoft° Right-JO Worksheet Job: AHU 2 Date:, Jun 21, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77I-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area OFFICE 17.0 ft 10.0 ft heat/cool 13.0 x 12.0 ft 156.0 ft2 FOYER 7.0 ft 10.0 ft heat/cool 7.0 x 8.0 ft 56.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (13tuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I ool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - 13A11ocs Y--0143 2 glazing,, low-e - 2 glazing,, clr-low-a 2 glazing, cir low-e 2 glazing, clnlow e-__.._� 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e ,2 gIazInq,_cIr low-e 13A flocs 2 glazing,'clrlow-e 2 glazing,,clr,tow-e 2 glazing, cir low-e r-__u e 13A-4ocs 2 glazmq cir low-e - .16X19.0td_._w _ 22A-tph 0.650 0.650 0.650 -0.650 0.143 0.650 0.650 . 0.650 0:143 0,650 0.650 0.650 0.143 0.650 n: n n n _-n- a a a --a_ s: s s s w w T 4.00 18:20 '1820, 18:20 _ 18.20- 4.00 0.00 0.00 18 20 4.00 0.00 `18.20 18.20 _ 4.00 18.20 169 38.02 . _ ' `. 2.19 14.99 . 1'4.99 14.99 - 1.4.99 2.19 0.00 0.00 _ 32.93 2.19 0.00 ' 14.99 14.99 �_14.99 2.19 31.52 - _ - 13U 0 0 36 _ __._,._ �_ 0 0 0 0 0 0 ` 0 0 ' 0 _0 40 0 - T 94 0 0 0 :. _-___.:0 0 0 0 0 - --- 376 0 0 655 ._ e_w 0 0 0 0 00 0, 0 0 0 160 0 - -- S' m 206 0 0 : ° 540 __:.-._ 0 0 0 0 - 70 0 18 0 _ 48 0 0 0 _-� _ 0 0 0 0 0 0 0 0 0 • 0 0 0 328 0 __._.._ 874 0 0 0 ---0 0 0, 0 0 ti-0 0 0 - 0 270 0 _-_..-_ 720. 0 0 0 0 0 0. 0 '_......__.0. 0 0 _ . V�J E-la ...... 0 0 0 --0 0 0 0 0 l-GGI __ 0- 0 0 ""0' -0'--' 40 0 0 0 0 0" � 88 0 .._2 ..: V)/ " 0 0 F _...0,408 1.358 . _.i 13.._. 0.00 1`� _ _..a:_ 1 17 .._ _247 646 �T _..__., _ 1T7.,. 0 .�. `� 56 _ 56 7 _.89.69, 266 ��-_ 0 . �156 �- _ _ 6 c)AED excursion -17 -17 Envelope loss/gain 2085 993 1572 1045 12 a) Infiltration b) Room ventilation 291 0 78 0 120 0 32 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 2376 1070 1692 1077 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 48% 0 0 752 3128 627 0 0 479 1549 742 20% 48% 0 0 -1692 0 0 0 0 -1077 0 0 Total room load Air required (cfm) :I I3755 123 2291 101 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r- w_rllsaft oft I 2021-Jun-21 14:21:22 RightSuite@ Universal 2021 21.0.02 RSU08101 ' Page 7 �`A E:\Documnets\WrightsoftHVAC\RAMISTRESIDENCE.rup Calc = MJ8 Front Doorfaces: N -�- wrightsoft Right-JO Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@ADL.COM Job: Date: Jun 21, 2021 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area GREAT RM 28.0 ft 10.0 ft heat/cool 28.0 x 16.0 ft 448.0 ft2 CLST 2 7.0 ft 10.0 ft heat/cool 3.0 x 9.0 ft 27.0 ft2 Ty Construction number U-value (Btuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ' ' . : -_ . 'h - ' ,G VV -_ C F _ - 13A flocs - 2 glazing, clrlow-e 2 glazing, clr low-e 2 glazing, cIr low-e 2.glazing, clr low e___ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq, cIr low-e.--- 13A=4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing,-clr-lowe--_ 13A4ocs _2.glazinq, clr lower__-- 16X18 Otd- __- _. 22A tph.-`- _ 0.0.143 0.650 0.650 0.650 0,650 0.143 0.650 0.650 .-._ _0.650 6.143 0.650 0.650 0.650 _ . 0.650 0.143 ---_0,650 _ _. _0.408 1.358 - n n h n --n--',-----18.20, a a a _ e,- s s s s __ s- w w_ _w_ - -- 4:00 18.20 1 18.20 18.20 4.00 0.00 0.00 18.20 4.00 0.00 18:20 18.20 -- 18.20 4.00 -_ 18.20 _. _ 159 313.02 1499 14.99 14.99 14.99 2.19 0.00 0.00 - 32.93 2.19 . 0.00 14.99 14.99 -_ 1,4.99 219 31.52 _ _ 1.13 0.00 0 0 0 -•-------__ 0 0 0 0 0- 0 0 0 - _ ,-._0 0 0 0 0 0 0 ___--_-__-0 0 0 0 0 0 0 0 ---------0 0 0 0 ---- -0-__-,__0_-___-.--.,._0 195 0 0 2858 _..__--__0 0 0 30 0 0 0 -------- 0 40 0 0 0 0 0 0 __.__-- 0 0 0 --- 30 0 0 0 ---- 40 0 0 0 0 0 0 __ -_-- - 0 0 0 ^--- 120 0' 0 0 160 0 0 - 0 0 0 0 _ -_ -_A 0 ---•--_0 -^_- 266 - 66 0 0 0 88 0 0 0' 0 0 0 __.-....._ .0 0 ------- U 31.. -. _ _0 -_.._-- 280 0 0 191 ------ -_0 0 0 - -0 89 0 0 191 ---_ __0 0 _ 0 _. 448 28 -0 358 0 0 3470 _-..-.__-0 0 0 __--- _ 448 448 .-_- . _ __ 710 - 1065 .__..__ b07 -i_-- 0 _-- - 27 _-_-- 27 ---�- ---- 7 6 c)AED excursion -65 -3 Envelope loss/gain 5603 3496 589 180 12 a) Infiltration b) Room ventilation 479 0 128 0 120 0 32 0 13 internal gains: Occupants @ 1 230 Appliances/other 0 0 500 0 0 0 Subtotal (lines 6 to 13) I 6081 4124 7091 212 14 15 Less edemal load Less transfer Redistribution Subtotal Duct loads 20% 48% 0 0 484 6566 1315 0 0 309 4433 2123 20% 48% 0 0 -709 0 0 0 0 -212 0 0 Toted room load Air required (cfm) 1 7881 1 257 6556 290 0 0, 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -Fk- wrigtttscxft• 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 8 . . E:%Documnets\Wdghtsoft WAC%RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N • -�- wrightsoft' Right-J® Worksheet Job: AHU 2 Date: Jun 21, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@}\OL.COM 1 2 3 4 5 Room name E)q)osed wall Room height Room dimensions Room area BEDROOM 2 15.0 ft 10.0 ft heat/cool 1.0 x 189.0 ft 189.0 ft2 BATH 2 5.0 ft 10.0 ft heat/cool 5.0 x 12.0 ft 60.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 11 `---- ',__-:_ b.2_qIazinq,_clr .--r---G W L-G O , F22A-tph.. __._ .. - - ----- 13A•4ocs 2 glazing, clr low-e 2 glazing, clrlow-e 2 glazing, clr low-e 2:glazing, clr low-e_ 13A-flocs 2 glazing, clr low-e 2 glazing, cir low-e low_-e,_ 1AAocs .2 glazing; clr'Iow-e 2 glazing, clr Iow-e 2 glazing, cir low- 2 glazing,_clr low-e_ _ - 13A-4ocs 2 glazing, clr low-e 16X130td -_..._ _----- - - --- 0.143 0.650 0.650 0.650 0 650 0.143 0.650 0.650 _0_.650 0.143 0.650 0.650 0.650 ___-' _0.650 0.143 0_650 0.408 -1.358 --1 n �; n n '' 'n __.n ' a a a e l s.-b s, s s .__.s w T w _ �- -- -- 4.00 18:20 18.20 18.20 . 1820. 4.00 0.00 0.00 .-18.20 4.00 0.00 18:20 18.20 _ 18.20: _. 4.00 18.20 1.59, 38_02 ---- 2.19 14.99 14.99 14.99' ___ 14.99 2.19 0.00 0.00 _--_32.93 2.19 0.00 14.99 14.99 ___14.99 2.19 31.52 1 13 _ 0 ^ - - 150 % . 0 36 _r ..__ -0.__ 0 0 0 _ _ 0 0 0 0 0 _. _._._0 0 0 189 ----189 ------ _ 114 ' 0 0 0 ______0 0 0 0 0 0 ---- 456 0 0 655 ...._- __0 0 0 0 _0 0 0 0- 0 _-0 0 0 -- - -- . 249 0 0 540 ___.__ _. __ 0 0 0 0 -0 0 0 0 0 _ ._ _ 0 0 0 --- - 50 9 0 0 ... ___,._:_0 0 0 0 __-_-__0 0 0 0 0 ,_._.. _, _. -0 0 - 0 - - - - 41 0 0 0 . _ __..-_ 0 0 0 0 - - 164. 164 0 0 ._.-_ _- .0 0 0 0 ____.-0 0 0 0 0 0 _ ___0 - - 90 135 0 0 _ "_. _ 0. 0 0 0 .0 0 0 0 A 0 -- -0 0 0 0 0 _:___._ 0 0 0 -.--___0 0 0 0 0 0 _--_ 0 _ . _ 189 --- 15 _ _- _ _ _;300 _- 570 -_ 214 ---- -_ - --- ---- 5 .. - �� -- ------ - -- -- ---- -- -- - 6 c)AED excursion -17 -5 Envelope loss/gain 19821 986 613 288 12 a) Infiltration b) Room ventilation 1 256 0 69 0 85 0 23 0 13 Internal gains: Occupants @ 230 Appliances/other, 0 0 0 0 0 0 Subtotal (lines 6 to 13) 2238 1055 699 311 14 15 Less extemal load 1 Less transfer 1 Redistribution 1 Subtotal Duct loads 20% 48% 0 0 991 3229 647 0 0 392 1447 693 20% 48% 0 0 0 699 140 0 0 0 311 149 Total room load Air required (cfm) 1 3876 127 2140 95 1 839 1 27 459 20 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c -1-w_rigFatsoft- 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 9 E:\Docur nets\Wrightsoft HVAC\RAM(ST RESI,DENCE.rup Calc = MJ8 Front Door faces: N -�- wrightsottm Right-J® Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE. FL 34946 Phone: 77-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM Job: Date: Jun 21, 2021 By: 1 2 3 4 5 Room name E)q)osed wall Room height Room dimensions Room area BEDROOM 3 31.0 ft 10.0 ft heat/cool 1.0 x 266.0 ft 266.0 ftz WIC 3 5.0 ft 10.0 ft heat/cool 9.0 x 5.0 ft 45.0 ftz Ty Construction number U-value (Btuh/f?- F) Or HTM (Btuh/ftz) Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/PIS Heat Cool Gross I N/PIS Heat Cool 6 11 13A flocs 2 glazing, clr lowme 2 gazing, glazing, clr'low-e 2 glazing, clr low-e .2 glazing; clr lowme_._ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2. glazing. cfr low-e 13A4ocs 2 glazing,,clr lower 2 glazing, clr low-e 2,glazing, clr low-e 2:glazing,:clr,low-e.__-. 13A-4ocs 3_dfazing, clr low-e _ 16X19--0td--_;_ 22Atph --_r-_ . 0.143 0.650 0.650 0.650 _ -0.650 0.143 0.650 0.650 -_..- 0.650 0.143 0.650 0.650 0650 `____-0.650---s- 0.143 0.650 _-._- n ' n n n _ n a a a -e - s s s s w w __ . _�. _ 4.00134 18:20 1820 18.20 _- 98.26 4.00 0.00 0.00 _ 18.20_ 4.00 0.00 18.20 18.20 18.20. 4.00 18.20 , ._ 159 - 38.02 14.99 14.99 14.99 _, --1 99 2.19 0.00 0.00 . 32.93 219 0.00 :14.99 1,4.99 14.99 2.19 31.52 0 0 36 _,.__= _ 0 0 0 0 - 0 ., 'e-� 0 „ 0 0 0 _ :0 140 0 _. 0 0 0 _.--,_.:_ ._0 0 0 0 - -_--- 537 0 0 655 ___ ' 0 0 0 0 0 0: 540 _.._-_0 0 0 0 0 0 0 0 ____ 0 306 -_^ 0 0 0 0 ___-.- 0 0 0 0 0 „ 0' 0 -__:_,- Q 0 0. 0 0 0 0 0 0 0 0 -__0 200 _ -.-_-0 --7.1 - 0 0 0 0 0 0 0 0 0 0 _ 0. 109 0 ..........._,. -- 0 :•. - 0 0 0 __.-. . y! F 0 0 0' 0' -0'___ 0 0 0 0 0 561 0 0 0 0 0, _.__ _0.._ 50 _0 0 0 0. 0 ___0 50 _. 0 140 0 _ 0.408 1_358 __. 9 13 _ 00.00 -_ _ ___266 _ .-� w__ _ 266 31 ,_ _ _ 422 , 1179 ___w 301 -- � .._: _, _ - 45 __.,-45 - 5 i _ ._.__-,._ 6 c)AED excursion -25 -8 Envelope loss/gain 3353 1416 462 153 12 a) Infiltration b) Room ventilation 530 0 142 0 85 0 23 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 1 300 Subtotal (lines 6 to 13) 3883 1558 547 476 14 15 Less extemal load 1 Less transfer Redistribution Subtotal Duct loads 20% 48% 0 0 8 3891 779 0 0 6 1563 749 209/6 48916 0 0 0 547 110 0 0 0 476 228 Total room load Air required (cfm) i 4670 153 2312 102 657 21 704 31 _ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c P. -P-via-=1gtZtsoft- I 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 10 .4�`EADocumnetslWrightsoft HVACIRAMIST RES[DENCE.rup Calc = MA Front Door faces: N i -P - wrightsoft9 RighWO Worksheet Job: AHU 2 Date: Jun 21, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 3 5.0 ft 10.0 ft heat/cool 1.0 x 85.0 ft 85.0 ft2 BATH 4 5.0 ft 10.0 ft heat/cool 1.0 x 85.0 ft 85.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 __._.. .,._ . ViJ ---__- C 13A flocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2.glazing,_clrlow-e--- 13A4ocs glazing, 213A-flocs clr clrloow-e 2 glazing, cir low-e glazinq, w-e-___ 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing,_cir low a ___ 13A-4ocs 2 glazing, cir lower__ 16X190td 0.143 0Z50 0.650 0.650 _._--_. 0.650 0.143 0.650 - 0.650 -0.650 0.143 0.650 0.650 0.650 _..._ 0,650 0.143 ---0.650 _ 0:408 1.358 n n n n __n_a a a a ,-_e_ s � s s s -_s_;. w 1 _ w !. 4:00 18.20 18.20 18.20 _. 18.20- 4.00 0.00 8.. �: 1.20 4.00 0.00 18.20 18.20 _w__.18.20. 4.00 -_18.20 1.59- 38.02 2.19 14.99 14.99 14.99 _..14.99 2.19 0.00 -._32.93 2.19 0.00 14.99 14.99 -__-14.99 2.19 _ 31.52 1,13" 0.00 0 0 0 0 0 0 0 0 U 0 0 0 0 ..---_- _0 0 0 0 --_9 0 0 0 0 ___ _._ _^0 41 -.._.---- 1 5 0 0 0 0 _____.__.0 0 0 0 ------0 0 0 0 0 . --__0 164 164 _ 190 0 0 0 0 . ___ .0 0 0 0 0 0 0 0 _-----. _ __ 0 0 0 0 --------0 0 0 0 0 w__.-_._._ 0 50 -9 --__-�---._ 85 0 0 0 0 . _ _ ---__0 0 0 0 ----_-Q 0 0 0 0 -- -. __-_ 0 41 ---1 _-85_--_ 5 0 0 0 0 __. :. 0 0 0 0 -.----_--0 0 0 0 0 _ _ _-- 0 164 - 164 _135 -- --_ 190 0 0 0 0 .... __-_-Q 0 0 0 ------__0 0 0 0 0 _.,. _ . _.:0 90 - -284 96 _ _.. _ 0 0 0 0 0 _- _._0 50 _ - - 9 _-�`---__-_.�` 85 ----Q 0 0 0 0 ___.... _ 0 90 ----284 96 0 -_ -- -- _ ----_ -- 6 c)AED excursion 1 1 127 127 Envelope loss/gain 653 59711 597 12 a) Infiltration b) Room ventilation 85 0 23 0 85 0 23 0 13 Internal gains: Occupants @ 1 230 Appliances/other 0 0 300 0 0 300 Subtotal (lines 6 to 13) 1 738 920 738 920 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 20% 48% 0 0 6 744 149 0 0 4 924 442 20% 480/6 0 0 8 746 150 0 0 6 925 443 Total room load Air required (cfm) WA 29 13M 60 896 29 1368 61 c -tad- wrigMtsof�^ 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSUD8101 Page 11 A E:\Documnets\WrightsoftWAC\RAMISTRESIDENCE.rup Calc = MJ8 Front Door faces: N -1- wrightsoft° Right-J® Worksheet Job: AHU 2 � Date: Jun 21, 2021 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77,2466.6799 Fax 772-466-6796 Email: QUICKCALCS c,10L.COM 1 2 3 4 5 Room name FVosed wall Room height Room dimensions Room area WIC 4 5.0 ft 10.0 ft heat/cool 9.0 x 5.0 ft 45.0 ftz BEDROOM 4 51.0 ft 10.0 ft heat/cool 1.0 x 261.0 ft 261.0 ftz Ty Construction number U-value (Btuh/ftz-°F) Or HTM (Btuh/ftz) Area (ft-) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 11 .---- 13A-46 ---- 2 glazing, clr low-e 2 glazing, cir Lowe 2 glazing, cir low-e .2-glazing, cir low-e---_. 13A4ocs 2 glazing, dr low-e 2 glazing, cir low-e gc lazinq, U lower.-- 13A-lots 2glazing, cirlow-e 2 glazing, clr low-e, 2 glazing, clr low-e 13A s clr lowe____ 2 q(azinq, cir low-e _ - --_0 -- -- - 0 0 0 0 - -_.- __._ 0.__-_ 152 0 0 ___-- 2 134 0 36 0 ._ __. _ 0 -- 0 - -- 0 ----- 51 --- 0 0 0 - -0 609 0 0 -_ -874 537 0 655 0 __ _ 5 1 561 -- -_ 0 ------1939 -- 0 0 0 . --- ..-0. 333 0 0 _----1581- 293 0 540 0 6 300 _ . 0 --- 0 - 0.149 0.650 0.650 0.650 __--.0.650 0.143 0.650 0.650 __-,-0 650 0.143 0.650 0.650 0.650 0.1� _ �0.143 . .. 0.408 --n n n n _._n. a a e i --e- s s s s -w i -w1 _---- -4A0 18.20 18.20 18.20 _ 18.20 4.00 0.00 0.00 __ 18..20 4.00 0.00 18.20 1.8.20 14.00. - _ 4.20 18.20 38.02 - 2.19 14.99 14.99 14.99 __..14.99 2.19 0.00 0.00 __- 32,93 2.19 0.00 14.99 14.99 ___12.19 2.19 31.52 _-_0.00 -----0 0 0 0 _----_._ U 0 0 0- --0- 0 0 0 ----_0 0 0 0 -. - _ 0 0 0 0 0 _ __ _ 0 50 --- - 0 0 0 0 _ _..---U 0 0 0 __-_-._0 0 0 0 0 _ _ ------0 200 0 0 0 0 --- -0 0 0 0 0 0 0 0 0 ------___0 200 0 0 -- 48 170 0 36 0 0 140 - -- 0 -- -- 261 y✓ I --G lI- ---,Y-0 0 0 ' 0 0 _. _- 0 50 _ -T 0 -- 45 _-_-_ 0 0 0 0 _-__ 0------' 109 -- -0 --- -0 __ 1-�1 ,_' -G - --- 190 ----- 5 - - -- --- -- - -- _4 -- -- - - - --- ----- -- - - - -- -- --- -- __ -..- ---- - - --_- -- - _ - - ----- - - - - - ---- - ------- -- - 6 c)AED excursion -8 -56 Envelope loss/gain 462 153 5588 3292 12 a) Infiltration b) Room ventilation 1 85 0 23 0 872 0 234 0 13 Internal gains: Occupants @ 1 230 Appliances/other 0 0 300 0 0 0 Subtotal (lines 6 to 13) 547 476 6459 3526 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 20% 48% 0 0 0 547 1101 0 0 0 476 228 20% 48% 0 0 8 6468 1296 0 0 6 3531 1691 Total room load Air required (cfm) 657 21 704 31 7763 2541231 5222 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fp- =10t%tsoft- 2021•Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 12 P. E:1Documnets%WrightsoftWAC\RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N I - wrightsoft Right-M Worksheet Job: AHU 2 j date: Jun 21, sosl By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area HALL 0 ft 10.0 ft heat/cool 4.0 x 7.0 ft 28.0 W Ty Construction number U-value (Btuh/ft2_°F) Or HTM (Btuh/ft2 Area (ft.) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A 4�co 2 glazing, clr low- 2 glazing, clr low-e 2 glazing, cir low-e 18Aazings clrJow�____ 2 glazing, cir low-e 2 glazing, clr low-e ? alazip%_clr low--e ---- 13A-4ocs' 2 glazing, clr low-e 2 glazing, clr low-e 2glazing, clr low-e 2.glazing,clr-.Iowa-..-_ 13A-4ocs 2 glazinq, _clr low-- 16X19-0td 22A tph. _ 0.143 0.650 0.650 0.650 0i650 0.650 0.650 -_0.650 0.143 0.650 0.650 0.650 _--_. 0.650 0.650 _ _0.650 .-_0.408 1.358 n° n ` n n e I' a a e l s s s s ._s_- w w _r- 4.00 ` 18.20 18.20 18.20 •_,.-14 0 0.00 0.00 ,18.20 4.00 0.00: 18.20 18.20 __18.20:- 4.20 18.20 159. 38.62 2.19 14.99 14.99 14.99 _ 12.9 0.00 0.00 32.93 - 2.19 0.00 14.99 14.99 14.99_._.__.-0_ 2.52 31.52 113, '0.00, - 0 0 0 , 0 ..__. - _..._..9 0 0 0 0 0 0 0 _._ ._..._ .o 0 0 --. 0 0 0 0 0 __.,.,-0 0 0 0 0 0 0 0 _.._ __._'0 0 0 0 0 0 0 _ _ . _.. o 0 0 ___._.-0 0 0 0 0 0.___.____- 0 0 0 _ .___. _,. _ .. _._ __-.-- •_- .-_ ._. _ ,_ ._..____. -----_._ _. -- --- --_ _-_ -_ I--G L�----(C . 1f1! �-C C F 0 0 0 0 0 _ 0 _28----__28..--_-- 28 --.__�_.__0 0 0 0 0 --- ----- __0.._.-___ 0 0 0 -____..- - - - -_--__-- _..-----_--_--- - ----_-- -------_-._- - --- 6 c)AED excursion 0 Envelope loss/gain 44 31 12 a) Infiltration b) Room %entilation 0 0 0 0 13 Internal gains: Occupants @ 1 230 Appliances/other 0 0 0 Subtotal Qines 6 to 13) 44 31 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 1 20°/u 48% 0 0 44 0 0 0 0 -31 0 0 11 otal room load T Air required (cfm) _T 01 0 0 0 Calculations aDDroved by ACCA to meet all requirements of Manual J 8th Ed. c,F wrightsoft- 2021-Jun-21 14:21:22 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 13 E:%Docurnnets%Wrightsoft HVACIRAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N t System s'tem Summary Job: �+ wrightsoft° Dy Date: Jun 21, 2021 AHU 1 By: QUICK CAL' CS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM For. SCOTT AND NATALYARAMIST 159 OCEAN ESTATES DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 182 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matti Actual Ln (ft) Ftg.Egv Ln (ft) Trunk LAUNDRY RM h 2405 108 102 1.000 7.0 Ox 0 VIFx 47.2 135.0 st3 M BATH h 3580 160 99 1.000 7.0 Ox 0 VIFx 37.6 135.0 st3 •TOILET c 791 35 39 1.000 5.0 Ox0 VIFx 39.0 135.0 st3 • WIC 1 h 990 44 37 1.000 5.0 Ox0 VIFx 29.4 115.0 st1 • WIC 2 c 549 7 27 1.000 5.0 Ox0 VIFx 27.1 115.0 stl MASTER BEDROOM c 2956 131 144 1.000 8.0 Ox0 VIFx 27.5 115.0 st1 MASTER BEDROOM -A c 2956 131 144 1.000 8.0 OxO VIFx 30.3 115.0 st1 POWDER RM c 711 12 35 1.000 5.0 Ox 0 VIFx 14.8 95.0 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 302 240 1.000 866 8.0 0 x 0 VinlFlx st1 st1 Peak AVF 615 592 1.000 783 12.0 0 x 0 VinlFix Name Grille Size (in) Htg (cfm) Clg i (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 627 627 0 0 0 0 Ox 0 VIFx Alk- wrightsoftPo I 2021-Jun-21 14:21:30 'fts .nek.m•io.. '--' .�.., Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 E:\Dacunets%Wrightscft WACIRAMIST RESIDENCE.rup Celc = MJB Front Door faces: N Job: -- wrightsoft° Duct System Summary Date: Jun21,2021 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM ruroject inTormation For. SCOTT AND NATALYARAMIST 159 OCEAN ESTATES DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm 265 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Cig (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BAW2 h 839 27 20 1.000 5.0 Ox 0 VIFx 55.9 135.0 st4 BATS 3 c 1366 29 60 1.000 6.0 Ox 0 VIFx 71.7 155.0 st5 BATH 4 c 1368 129 61 1.000 6.0 Ox 0 VIFx 89.7 175.0 st6 BEDROOM 2 h 3876 127 95 1.000 7.0 OxO VIFx 45.2 135.0 st4 BEDROOM 3 h 4670 153 102 1.000 7.0 Ox 0 VIFx 67.3 155.0 st5 BEDROOM 4 h 7763 254 231 1.000 8.0 Ox 0 VIFx 86.5 175.0 st6 GREAT RM c 3278 129 145 1.000 8.0 Ox 0 VIFx 51.5 135.0 st4 GREAT RM-A c 3278 129 145 1.000 8.0 Ox0 VIFx 48.6 135.0 st4 KITCHEN c 3377 132 149 1.000 8.0 Ox 0 VIFx 23.2 115.0 st2 OFFICE h 3755 123 101 1.000 7.0 Ox0 VIFx 24.4 115.0 st2 WIC c 704 1 21 31 1.000 5.0 Ox0 VIFx 69.3 155.0 st5 WIC 4 c 704 21 31 1.000 5.0 Ox 0 VIFx 87.3 175.0 st6 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st6 Peak AVF 304 323 1.000 592 10.0 0 x 0 VinlFlx st5 st5 Peak AVF 507 517 1.000 658 12.0 0 x 0 VinlFlx st4 st4 Peak AVF 919 922 1.000 863 14.0 0 x 0 VinlFlx st2 st2 Peak AVF 1173 1173 1.000 840 16.0 0 x 0 VinlFlx - wrightsoft® 2021-Jun-21 14:21:30 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 2 A EADocumnets\Wrightsoft WAC\RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1173 1173 0 0 0 0 Ox 0 VIFx wrightsoft- 2021-Jun-21 14:21:30 awYNra w.�ww. r�=�wr Right -Suite® Universal 2021 21.0.02 RSU08101 Page 3 AM E:\Documnets\Wrightsoft HVAC\RAMIST RESIDENCE.rup Calc = MJ8 Front Door faces: N