Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FL NOA 21461 ES-EL 150 with cover sheet(1)
Business & Professional Regulation BCIS Home ( Log In User Registration Hot Topics Submit Surcharge i Stats to Facts Publications Contact Us j BCIS Site Map Links j Search F figsa Aft r Product Approval L USER:Public User (`J,111.�--►� („1j' Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FLvision R3 V V / Application Type Revision � \,^�'{1\ry / Code Version 2020 r rIJ�V �/ Application Status Approved Comments Archived Product Manufacturer E.S. Windows,Inc. Address/Phone/Email 10653 NE Quaybridge Ct Miami, FL 33138 (305)624-7775 achamorro@eswllc.com Authorized Signature ]alai Farooq veronica@afceng.com Technical Representative Manuel Perez Address/Phone/Email 10653 NE Quaybridge Ct. Miami, FL 33138 maph@bellsouth.net Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Jalal Farooq Evaluation Report Florida License PE-81223 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/16/2025 Validated By JAVAD AHMAD PE, INC. Validation Checklist-Hardcopy Received Certificate of Independence FL21461 R3 COI SS-EL150 FIXED ALUM WINDOW(LMI NI)-CI 2020.odf Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/13/2020 Date Validated 08/13/2020 Date Pending FBC Approval 08/22/2020 Date Approved 10/13/2020 Summary of Products FL# Model,Number or Name Description 21461.1 Series ES-EL150 Aluminum Fixed Large missile impact resistant aluminum fixed window. Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL21461 R3 II SS-ES E1 150 FX(LMI) DWG W16-76 Approved for use outside HVHZ:Yes !.=ZQ)_Psf Impact Resistant:Yes Verified By: ]alai Farooq PE#81223 Design Pressure: +80/-105 Created by Independent Third Party: Yes Other:See drawing W16-76 for span vs. load combinations !Evaluation Reports and installation details. FL21461 R3 AE SS- ES-EL150 Alum FW(LMI)-PAE 2020.pdf Created by Independent Third Party: Yes 21461.2 Series ES-EL150 Aluminum Fixed Non-impact resistant aluminum fixed window. Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL21461 R3 II SS-ES-EL150 FIXED ALUM WDW(NI) -DWG Approved for use outside HVHZ:Yes 20-61F•pdP Impact Resistant: No Verified By: ]alai Farooq PE#81223 Design Pressure: +80/-80 Created by Independent Third Party:Yes Other:See drawing 20-61F for span vs. load combinations Evaluation Reports and installation details FL21461 R3 AE SS-ES-EL150 Alum FW(NI)-PAE 2020.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Qpyr 2007-2013 Stale of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card safe 0 0 �1 � 0 -0 X M '=1 n ;vm � o > � 0 ;d ' 0 - 0 cl) z t�7 D 0 a D r d r r cQ7 -0 0 D SOD � Q 0 m 0 a � 0 r O � z < cn -0z z Om rn 0 � zz WC Z � Nr0x -A cnw C r 0-�-' 2 -I ;;a O C -q Cn m -1 O70 m _l (n x O (n _ z 00 Z 0 � r fri W 2 J T1 - W -TiC Dann d m � q * x Z O m oM 0 N c'' z rnc� z70 m i1 � O N =i K2 (n m c O 0 0 0 A n m -I m (D y 108" r=r1 -< co m m m WINDOW HEIGHT r Z � (n r m m-u� 02 m z A o rn 0 O O 104 / " z mcn omo czn D.L. OPG. Z� K m C m cn0 �� X Z G) Z� 0 >0 0-n XOK D D ADD �0- COX jII II D m zODmO2_ mOD r DZZ Om 00 Cm2 (n K r r ---I p 0 (n-< r p (n III _ M D c - m� CC m m O m 2 5 v_ C -0 --- -�__�—_- - rnm Z -1'O-iDm �] -� 2 -z0 mZ� Z71 -0 m --- I- =1 =--II -� _- �On Op-C(n70 mZr D� (xn 0 0 � 0 z D �D p Cn -IOC y M(Zn��m0 ZON �rUl WDc � m0 m f�m II ill IrO III r � O pD�7 -( 2rS rZ � O Z m o ;u 0 O z p D D m p o 0 O m rn OOA (n rA*1�Dm p� cnOr -i r0D z_� m A r --- 00 Omni (n G-4 1 m> O ZC W O m r G�Zp Z y � < o m(nOm-� �1D0 m Z Wm Ill N0 O (n m D jII II I 2 m�� 0 *=ZOTIm Oz S m� m �- r N -- - --�r== 7�F �<2� Z 00�u 0 a: n m� 0 ;v-C � f2T( � —_ ==— IXN��� �m< o< m � _ X m c . -in(n �Z-0 co Z or o2W D Oc � �px 0 NJ 0Z Z 11 !I II (n Z c (n 2�2 m OD �o m 0T!O �D p (nO> m - Z=c) v�0 D (n A r'irpTlf� � J � mZr D r20(n IO �2--I cn 0 0 2^- 0 (n 0-m m (" m ➢Z z Cw O m -0 z oar c rcn DC < � z 12" oar o c�0 0 o' �_ No O 0 m cn r x m m X 0 6" MAX. MAX. --] 0 z -q1�c:r-lO � �o z 0 mO (n �n z JAMB JAMBS Dom D �z Q�� o -�o m o z0 � om : o0 CORNERS cDTl 0 DD Z"DTI0 D XN r (mn c)N mm c\(n 108„ Nr-0 D m OmOm Wpm C� O 0(n -0 ZN MOrm*1 O m m (n 0 D m D z A m n No 0 WINDOW HEIGHT �D m O DOZ Vim\ Z 0 (nnm m� D -4 _ o� (n W Z O O ODD 0 m c-n 0 m—'j 104 7/8" 0 m m = 0 uri D z Z crn �i 0 > >o� N = o D.L. OPG. Z� � C� m D D(nx m r 0 0 0 -Ur2Tm 0MK AN X r� (Nn D � O �N Z = (n r� Zp a)O N� 0 r O-0< R. 2 0 O 0 a) 2 m(n m r 2< N z0 Dr-m O N rn0`z pV O m (n m 00 0 � Z -uC <Z`L_' W 0 C- O �JC _ O r Z Z M M z m U1 2 r Z -- ------- p z>0 m fmT1� 0 O ---i OZ p M N p D _- ----I�--- m z (n 0 m -a m m I I m0 ^D > ZD� 0 �= N i 0p n � 2 m II II II O LO D Z D W O O m m m �___�__-L==- D D Om> (ten 2 r 0 1 II II II Ii m m0- Zm m o � r 0 D M D 0) co II �I jII II rnD p 0 r D Z r(nr1 (n r , r p < ; r - nl --- L ===I$===-1------ 0 p = r -I=__� �\ II OD Un m m II v 00 m D c D �- (nmcmmcn D� 0 u 2 0 -- 2 (n -_I -1 ----------- —= 2 xx -uzw0Z=I �= z�vi0 = O = --- II --7 ---tt--- 11 �� ➢N mN mc�mAZm min �ODZ 11 II II X m� �mp�mc' m- =5 -y o Z II rp ' Om (�zmm�m o0 �0—1 -0 m� 0--1 {0 o=Oz m of >�m0>0 D� c�z� zD x-U -u -< 3NOO rr �m fTl n�0 3< z rm ci 12rr z C0 m ' P D 3 mi z� �o�m 6„ MAX. MAX. z� 0 0zogN cn� N-uN N � JAMB JAMBS m= A z-g 0 cn z m 2 2 CORNERS xm mOz=x= o ooz C N 00 F,mrm`(�gr O �Cfn m = n �m :E O o�m rrI 0 ;a �0F: m c rZmm ;1 `L �0 co m mZ =mr�v m DDT Z m V) �o �mW ;m mom Dv0 p 96„ _X c 0 m F rn-0 o z m m WINDOW HEIGHT D� mo,mo r K Z m = 2 �D- �Dzzm Cu =gym � � m 000 927/8„ �mrn (�(n0� D >rr 2 W A m m o n o � I�TI � U � O O r � o z CD D.L. OPG. �N X aZ "'>moo0 m 00- Q z0z CD0C m O (n S m N un Nr �DTm> 0 50c 00 �70 �l pm0 N z moT0m N�= W 0 q D 2 = m (mn m n rr`(m 700 cm� < 0 r-D O Z ITl Z_ = m c =mA�� D m c m (n A m m m>0oz F-> fv r II O z K > O �rrr, m O z O D N DD m D _ -- ---L—- - Z m o m�O o z o (O D Z D m (n r = =--1 ---11 - =- o 0 ®®p01BBBB9®� _ O � m� �W jII A\��I �D 0 � * � U) Q 2 q v z D� =- U co r 1�=== cn� X N = r S� m Dp 0 p o coo r 2 � v Z a Z � m cNn - W I OK% A C o m 0 cn N { p 6„ MAX. MAX. ®a o JAMB JAMBS Ca l y CORNERS U revisions: ES-EL150 FIXED ALUMINUM WDW. (L.M.I.) AL-FAROOQ CORPORATION a c a date: 11-29-16 ENGINEERS&PRODUCT DEVELOPMENT m fl no a e escrI Ion A 12.05.17 UPDATED TO 2017 FBC E.S. WINDOWS, LLC 9360 SUNSET DRIVE,SUITE 220 B 05.11.20 GENERAL REVISION 3550 N.W. 49 STREET MIAMI, FLORIDA 33173 (C.A.N. 3538) O dr. by: TARIQ MIAMI, FL. 33142 TEL.(305)264 8100 FAX.(305)262-6978 (fl 0-) 9 chk. by: TEL. (305) 638-5151 FAX. (305) 638-5158 COMP-ANL\W16-76ES 1/W HEAT STREN'D. GLASS 3/16" HEAT STREN'D. GLASS crown .090" Interlayer .090" Interlayer I Trosifol PVB Trosifol PVB CO By `Kuraray America, Inc.' By 'Kuraray America, .Inc.' m 3 OR OR h .090" Interlayer .090" Interlayer ® IF— ccn ( Q SentryGlas SentryGlos GA a By 'Kuraray America, Inc.` By 'Kuraray America, Inc.' 2 a :2 OR OR (L U a o .090" Interlayer .090" Interlayer ® W Saflex Clear And Color Glass Saflex Clear And Color Glass N By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' a: O OR OR .075" Interlayer .075" Interlayer 0 t N h Saflex CP With PET Core. Saflex CP With PET Core ui'A By 'Eastmon Chemical Co.' By 'Eastman Chemical Co.' 0 IX uj 3/16- HEAT STREN'D. GLASS ® a G D 1/4" HEAT STREN'D. GLASS m ® � z SILICONE N O ry N M2 SILICONE (n M2 DOWSIL 795 5 16" AIR SPACE CONSISTING OF: W.0 L DOWSIL 795 I: I Q � I F � I DOWSIL 983. DOWSIL .983 c� !� DOWSIL INSTANT GLAZE III SPACER: O iI II DOWSIL INSTANT .GLAZE ill ii ii `HELIMA' LOW PROFILE ALUMINUM SPACER Q J it ijI i! i! BY 'LINGERMANN GMBH' AROUND THE PERIMETER OF THE GLASS. o' Of PERIMETER SEALANT: o a SILICONE E7 , E7 DOW CORNING 791 _ 00 w M3 AT 1/4 POINTS ON LITES w M3 AT 1/4 POINTS ON UTES GE 2000 .1 'n WIDER THAN 36" ONLY WIDER THAN 36" ONLY 3� GLASS TYPE 'A' `° GLASS TYPE `B' •• 7/16" OVERALL LAM. GLASS 7/16" OVERALL LAM. GLASS � M Z U H 1/8" TEMP, GLASS 1/4" TEMP. GLASS J J � r 5/32" TEMP. GLASS Q cc 5/16" AIR SPACE 5/16" AIR SPACE ~ � 5/16" AIR SPACE 0 � r 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS 7G O 5/32" HEAT STREN'D, GLASS L� r� .090" Interlayer 09D" Interlayer 690" Interlayer O Z J Trosifol PVB Trosifol PVB n -- Trosifol PVB 3: � u� By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' o OR LLJ OR OR I �.o .090" Interlayer .090" Interlayer .090" Interloyer w L�.I L LW SentryGlas SentryGlas By 'Kuraray America, Inc.' By. 'Kuraroy America, Inc.' By 'Kuraray America, Inc.' OR OR OR ,090" Interlayer 4 .090" Interlayer 1 .090" Interlayer Saflex Clear And Color Glass Saflex Clear And Color Glass Saflex Clear And Color Glass By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' OR OR OR .075" Interloyer .075" Interloyer .075" Interlayer Saflex CP With PET Core Saflex CP With PET Core Saflex CP With PET Core By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' DOWSIL SILI O 91 By 'Eastman Chemical Co.' ° La 1/4" HS. GLASS 5/32" HEAT STREN'D. GLASS (1/8" x 1/16") 1/8" HS. GLASS SILICONE SILICONE DOWSIL 795 w DOWSIL 795 w SILICONE m DOWSIL 983 DOWSIL 983 m DOWSIL 795 z DOWSIL INSTANT GLAZE III z DOWSIL INSTANT GLAZE III z Sealed:8/13/2020 Mz is g Mz i M2B �� FL #21461 N o ct II I III N II II II N I . I. I. >i �I II II II II II ti ggqqllPlppP® Ii jI j:. i. :. Emi e r N a Q v s I CY cv 0 o a No.81223 E4 w E4 w E4A x M4 AT 1/4 POINTS x M4 AT 1/4 POINTS X M4 AT 1/4 POINTS 41 ALL SIZES ``' ALL SIZES u' ALL SIZES GLASS TYPE 'Ai' GLASS TYPE 'Di' GLASS TYPE 'Ei' ®�°°°,° O ° 1>1 drawing no. 7/8" OVERALL INSUL. LAM. GLASS 7/8" OVERALL INSUL. LAM. GLASS 7/3" OVERALL INSUL, LAM. GLASS i�� ��`oe W16-76 GLAZING OPTIONS /�®���p t l��q����� sheet 2 of g w 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS 3/16" HEAT STREN'D. GLASS. 3/16" HEAT STREN'D. GLASS � c .090" Interlayer .090" Interlayer .090" Interlayer .090" Interlayer ® h SentryGlas SentryGlas SentryGlas SentryGlas co C? ¢ By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' III :� 9 31 n 1/4 BEAT STREN'D. GLASS o 1/4" HEAT STREN'D, GLASS 3/16" HEAT STREN'D. GLASS 3/16" HEAT STREN'D. GLASS G o m SILICONE m SILICONE m SILICONE m SILICONE z DOWSIL 795 DOWSIL 795 Z 0 DOWSIL 795 N DOWSIL 795 0 U. g N M2 j, co M2A I: I j� A � M2A � Ii Ii i� j It i It i ii oUF VA >M iil ii !il �j !i Ii Ii � $ I,- : I . . , : i. ® R.O � LDL6 E7 w E7A E7 w E7A W U) - o w M3 AT 1/4 POINTS ON LITES w M3 AT 1/4 POINTS ON LITES. w M3 AT 1/4 POINTS ON LITES w M3 AT 1/4 POINTS ON LITES WIDER THAN 36" ONLY WIDER THAN 36" ONLY WIDER THAN 36 ONLY WIDER THAN 36" ONLY W M GLASS TYPE 'AA' GLASS TYPE 'BB' 7/16" OVERALL LAM. GLASS 7/16" OVERALL LAM. GLASS co p (0 � O _j J -J w Q tY d V) (n 0 � f1 1/8" TEMP. GLASS 0 K°Oi a Z �i J � 5/16" AIR SPACE Z a 1/8" HEAT STREN'D. GLASS {!? O ¢ J Li-1 r7 .090" Interlayer SentryGlas SILICONE By 'Kuraray America, Ina` DOWSIL 791 (1/8" x 1/4") 1/4" HS. GLASS bi SILICONE DOWSIL 795 co N j: v M2B j� Ij jl ai it Sealed:8/13/2020 c 0 0.L n 0 w E4A `{{1l9.11lIdlS � c AT 1/4 POINTS M4 ALL SIZES ��� per•° n>S`® c4 GLASS TYPE 'AAi' N N 7/8" OVERALL INSUL, LAM, GLASS No.81223,e� 9 s drawing no. W16-76 GLAZING OPTIONS FL #21461 //f ��� {����` sheet 2.lflf 9 DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY - PSF WINDOW WINDOW FLANGE FRAMES, FLUSH FRAMES, FIN FRAMES FLANGE FRAMES, FLUSH FRAMES, FIN FRAMES WIDTH WIDTH�{ }� WIDTH--� n GLASS TYPE GLASS TYPES GLASS TYPE GLASS TYPES WINDOW DIMS. A °B', 'Ai', 'Di', 'Ei' WINDOW DIMS. A' 'B', `Ai', 'Di', `Ei' x = � � 10 WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) WIDTH HEIGHT EXT.(+) 1 NT,(-) EXT.(+) 1 NT,(-) Z I I z ® 16 16 m J 30" 60.0 80.0 80.0 80.0 30" 60.0 80.0 80.0 80.0 � . T a 36" 60.0 80'0 80.0 80.0 36" 102" 60.0 72.9 80.0 80.0 �o /� O (L O 42" 48" 60,0 68.6 80.0 80.0 42" 60.0 64.8 80.0 80.0 z Z O 0 M U 48" 60.0 60.0 80.0 80.0 30" 60.0 8010 80.0 80.0 I 3. ® LLI � y 54" 60,0 60.0 80.0 80.0 36" 108" 60.D 72.D Sn.O 80.0 L -) Q C 60" 60.0 60.0 80.0 80.0 42" 60.0 63.8 80.0 80.0 0 E4 ti 30" 60.0 80.0 80.0 80.0 30" 60.0 80.0 80.0 80.0 0 W m 114" WINDOW WIDTH WINDOW WIDTH �+ OEM rr co p 36" 60.0 80.0 80.0 80.0 36" 60.0 71.3 80.0 SO.D ® CL 0 el 42" 54" 60.0 68.6 80.0 .80.0 30" 60.0 80.0 8D.0 80.O 120" � - - � -r - - -\\ I, () 48" 60.0 60.0 80.0 80.0 36" 60.0 70.6 8Q0 80.0 yl I = I � 0 054" 53.3 53.3 71.1 71.1 z z I �r Z M60" 53.3 53.3 71.1 71.1 '� <� , 0230" 60.0 80,0 80.0 80.0 ' / Z to € II � � Wa� f" 36" 60.0 8010 8010 80,0 DESIGN LOAD CAPACITY - PSF I- J 42" 60" 60.0 68.6 80.0 80.0 FLANGE FRAMES, FLUSH FRAMES, FIN FRAMES '~ 48" 60.0 60.0 80.0 80.0 GLASS TYPE GLASS TYPES WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH ,°D° 54° 53.3 53.3 71.1 71.1 WINDOW DIMS. `A' °B', 'Ai', 'Di', 'Ei' 60" 4&0 48.0 64:D 64A WIDTH HEIGHT EXT,(+) 1 NT,(-) EXT.(+) 1 NT.(-) � I� 30" 60.0 80,0 80.0 8010 19-1/8" 60.0 80.0 80.0 80.0 = i -z", - - - 36" 60.0 80.0 80.0 80.n 26-1/2" 60.0 80.0 80.0 80.0 42" 6fi" 60.0 68.6 80.0 80.0 37" 26" 60.0 80.0 30.0 80.0 Iz ,, I w48" 60.0 60.0 80.0 80.0 48" 60.0 80,0 80.0 80.0 I 3 I 0 54" 53.3 5313 71,1 71.1 53-1/8" 60.0 80.0 80.0 80.0 L J-3t I I Q -t � 60" 48.0 48.0 64.0 64.0 19-1/8" 60.0 80.0 80.0 80.0 O (%1I _ 30" 60.O 80.0 80.0 80.0 26-1/2" 60.0 80.0 80.0 80.0 w. � ' � x rn LO 36" 60.0 80.0 80.0 80.0 37" 38-3/8" 60.0 77.8 80.0 80,0 WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH ti © � r� 42" 72" 60.0 68,6 80.0 80.0 48" 60.0 75.0 80.0 80.0 p Z_ J 48 60.0 60.0 80:0 80,0 53-1/8" 60.0 75.0 80.0 80.0 - - tF� J54" 53.3 53.3 71.1 71.1 19-1/8" 60.0 80.0 80.0 80.0 z / I z ' w (n O 6D" 4$.0 4$.0 64.0 64.0 26-1/2" 60.0 80.0 80.0 80.0 % I r w uj r 3D" 60.0 80.0 80.0 80.0 37" 50-5/8" 60.0 77.8 80.0 80.0 36" 60.0 78.0 80.0 80.0 48" 60.0 60.0 80.0 80.0 42" 78" 60.0 68.6 80.0 80.0 53-1/8" 56,9 56.9 75,9 75.9 48" 60.0 60.0 80.G 80,o 19-1/8" 60.0 80.0 80.0 80.0 ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE 54" 53.3 53.3 71.1 71.1 26--1/2" 60:0 80.0 80.0 80.0 VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHW SQUARE OR RECTANGLE AS 30 60.d 80.4 80.0 80,0 37" 58" 60.0 77,8 80.0 8d.0 SHOWN IN DOTTED LINES AND OBTA#NING ALLOWABLE LOADS FROM THOSE SHAPES, " c 36" 60.0 76.4 80.0 80.0 48" 60.0 60.0 80.0 80.0 0 42" 84 60.0 68.6 80.0 8010 53-1/8" 54.2 54.2 72.3 72.3 9 48" 60.0 60.0 80.0 50.0 19-1/8" 60.0 80.0 80.0 80.0 54" 53.3 53.3 71.1 71.1 26-1/2" 60.0 80.0 8D,0 80,0 30" 60.0 80.0 80.0 80.0 37" 63" 6010 77.8 80.0 80.0 --W � NOTE: s" gd„ 60.0 75.0 80.0 80.a 4$" 6a,o 60.o sp.o sn.o GLASS CAPACITIES ON THIS SHEET ARE 42" 60.0 67.1 8010 80.0 53-1/8" 54.2 54.2 72.3. 72.3 BASED ON AST I E1300-09 (3 SEC. GUSTS). .2 0 48" 60.0 60.0 80.0 80.0 19-1/8" 60.0 80:0 SO.D 80.0 I aqi o 30" 60.0 80,0 80.0 80.0 26-1/2" 60.0 80.0 80.0 solo L 7F,44 o 36" 60.0 73,8 80.0 -80.0 37" 76" 60.0 77.2 80.0 80.0 f 96 o ,c Ri,S 1 N 42" 6D.0 65.8 80.0 80.0 48" 60.0 60.0 80.0 80.0 a � N Q 48" 60.0 60.0 $0.0 BD.O .53-1/8" 1 1 54.2 54.2 72.3 72.3 % �ji No° 81223- ! ; L T7 V �T °°��` drawing no. NOTE. Sealed:8/13/2020 �� s WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED �L /��0 1W1 6-- 7 6 VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE, FL #2 146 1 i/fill, 111 'ie sheet 3 of 9 11 DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY - PSF WINDOW WINDOW Lu FLANGE FRAMES & FLUSH FRAMES ONLY FLANGE FRAMES & FLUSH FRAMES ONLY YODTH WIDTH c° GLASS TYPES GLASS TYPE GLASS TYPES GLASS TYPE WINDOW DIMS. 'AA' & 'AAi' 'BB' WINDOW DIMS. 'AA' & 'AAi' BB' � -� � WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) I NT.(-) ! 0 M Z ® � � °' 48 80.0 105.0 80.0 100.0 48" - - 80'0 80.0 Z �' 1 J J �. W 54" BO.O 105.0 80.0 100.0 54" 102" - - 80.0 80.0 30 'i o N 60" 80.0 105.0 80.0 100,0 60" - - 8010 80.0 z z 00 O 66" 48 80.0 105.0 80.0 100.0 48" - - 80.0 80.0 3: ! 3 W ri v 72" 80.0 105.0 80.0 100.0 54" 108° - - 80.0 80.0 L J p 78" 80.0 105.0 80.0 100.0 601, - - 80.0 80.0 ('6 r 48" 84.D 105.0 80.0 100.0 48" 80.0 80.0 Q W d 114" WINDOW WIDTH WINDOW WIDTH go ?M 54" 71,1 93.3 80.0 88.9 54" - - 80.0 80.0 ! -� IL Q Q A 60' 71.1 93.3 80.0 88.9 4$" - - 80.0 SO.d I FO 54" i 20" r - - - - ca W E 66" 71.1 93.3 80.0 68.9 54" - - 80.0 80.0 ! ! _ ! fl N 72" - - 80.0 88.9 z W 0 78" - - 80.0 88.9 w i Lu M 48" aD:O 14s.d Bo.d 1D4.o ! ! ! w M 54" 71.1 93.3 80.0 88.9 L 60" 60„ 64.0 84.0 80.0 80.0 - - 66" - - 80.0 80.0 DESIGN LOAD CAPACITY - PSF WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH co co 72" - - 80.0 80.0 FLANGE FRAMES & FLUSH FRAMES ONLY .. �n 78" - - 80.0 80.0 GLASS TYPES GLASS TYPE 48" 80.0 105.0 80.0 10010 WINDOWDIMS. 'AA' & 'AAi' BB' r - - - - - - - , r 54" 71.1 93.3 80.0 88..9 WIDTH HEIGHT EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) ! 80.0 80.0 19-1/8" 80.0 105.0 80.0 100.0 w ! ! �. ( i 66" - - 72,7 72.7 25-1/2" 80,0 105.0 80.0 100.0 .y U 72" - - 72.7 72.7 37" 26" 80.0 105.0 80.0 100.0 ! -j W 78" - - 72.7 72.7 48" 80.0 105.0 80.0 100.0 - Q N 48" 80.0 105.0 80.0 100.0 53-1/8" 80.0 105.0 80.0 100.0 0 N 54" - 80.0 88.9 19-1 8' 80.0 105.0 80.0 100.0 X O " / WINDOW WIDTH WINDOW W#DTH WINDOW WIDTH 0 r� 60" 72„ - - 80.0 80.0 26-1/2" 80.0 105.0 80.0 100.0 p _Z ED 66" ! - - 72.7 72.7 37" 38-3/8" 80.0 105.0 80.0 100.0 F w 72 1 - 66.7 66.7 48" 80.0 105.0 80.0 100.0 z O ~• 78" - - 66.7 66.7 53-1/$" 80.D 105.0 80.0 100.0 'i ::i 'i Lij Q w 48" 80.0 105.0 80.0 100.0 19-1/8" 80.0 105.0 80.0 100.0 ! w ~ 54" - - 80.0 88.9 26-1/2 80.0 105,0 80.0 100.0 60" 78" - - 80.0 80.0 37" 50-5/8" 80'0 105.0 80.0 100.0 66" - - 72.7 72.7 48" 80.0 105.0 80.0 100.0 ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE 72" - - 66.7 66.7 53-1/8 75.9 99,6 80.0 94.6 VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHW SQUARE OR RECTANGLE AS 78" - - 61.5 51.5 19-1/8" 80.0 105.0 80.0 100.0 SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. c 48" - _- 80.0 100.0 26-1/2" 80.0 105.0 80.0 100.0 54" - - 80.0 88.9 37" 58" 80.0 105.0 80.0 100.0 c U 60" 84„ I - 80.0 80.0 1 48' 80.0 105.0 80.0 100.0 co 66" - - 72.7 72,7 53-1/8" 72.3 94.9 80.0 90.4 72" - - 66.7 66.7 19-1/8" 80.0 105.0 80.0 100.0 W NOTE: 48" - - 80.0 100.0 26-1/2" 80.0 105.0 80.0 100.0 1 GLASS CAPACITIES ON THIS SHEET ARE 54" 1 - - 80.0 80.0 37" 63" 80.4 105.0 80.0 100.0 BASEC3 ON ASTM E1300-09 {3 SEC. GUSTS). o 0 60" 90" - - 80.0 80.0 48" 80.0 105.0 80.0 100.0 66 _ 72.7 72.7 53-1/8' 72.3 94.9 80.0 90.4 L `vlhlllPl���'® L 72" - - 66,7 66.7 19-1/8" 80.0 105.0 80.0 100.0 �,eCEiuS� �� 48" - - 80.0 100.0 26-1/2" 80.0 10510 80.0 100.0 " m o i N 54" - - 80 �® �� �� .0 80.0 37" 76" 80.0 105.0 80.0 100.0 �, m `' a 60" 96 - - 80.0 80.0 48" 80.0 105.0 80.0 100,0 - 66" _ 72.7 72.7 53-1/8" - - 80.0 90.4 a L r B W U 1 ° Sealed:8/13/2020 �9� drawing no. NOTE: �� °°° ® � WIDTH T CA AND OR HORIZONTALLY DIMENSIONS CAN BE ORIENTED ABOVE, �+ L #2�4�� /®° �j/v �� ���°�` W 16VER -7 6 °�darelll►deo sheet 3_1of 9 1 BY TYPICAL ANCHORS Y ui SEE ELEV. WOOD BUCK �. FOR SPACING — q Q Q \ n METAL I I F.B.C. APPROVED I € `fl EDGE DIST. EDGE STRUCTURE 1 € I I a e O cn I MULLION & MULLION ANCHORS 1 3 a Q q n DIST. I SEE SEPARATE APPROVAL ! J r o EDGE DIST. I I €1 ® F � 4) I N O 1 I EDGE DIST. I ; '�" I € 2 N d E1 I I® w 0 II I! !t z qq �s � l fl II �Q �m II II !! TYPICAL ANCHORS TYPICAL ANCHORS TYPICAL ANCHORS d®I d D a !I !I !I SEE ELEV. SEE ELEV. SEE ELEV. ® � FOR SPACING FOR SPACING FOR SPACING U) x Q z U. WOOD BUCKS AND METAL STRUCTURE NOT BY 'E.S. WINDOWS z t J MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM W 0, 0 !� !! AND TRANSFER THEM TO THE BUILDING STRUCTURE. ti a If ! ! I II TYPICAL ANCHORS: SEE ELEV. FOR SPACING coII it � � u� 11 it ii 1/4" DIA. TAPCON BY 'ITW' (Fu=125 KSI, Fy=100 KSI) LO Ij r tj ii is ii 1/4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 KSI) it i! i! INTO 2BY WOOD BUCKS OR WOOD STRUCTURES1 ii o ii it ii 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) z it THRU 1 BY BUCKS INTO CONC. OR MASONRY J 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) Q CL 0 it it 4 1-1/4" MIN. EMBED INTO MASONRY (JAMBS) o V) cn Z a` !i I, DIRECTLY INTO CONCRETE OR MASONRY X O i' D ii 1-1/2" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) o 1-1/4" MIN. EMBED INTO MASONRY (JAMBS) 2 .- W J z o H L ii 1/4" DIA. TEKS OR SELF DRILLING SCREWS (GRADE 5 CRS) ' O i I N fn W ii ii INTO F.B.C. APPROVED MULLIONS w L>J OR A. INTO METAL STRUCTURES (HEAD/SILL/JAMBS) ! !i (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK, MIN. (6063—T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) II !1 !I !I !I (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE ° t! I! II II I! INTO CONCRETE AND MASONRY = 2" MIN. i i t i i s INTO WOOD STRUCTURE = 1" MIN. a� INTO METAL STRUCTURE — 3/4" MIN. O WOOD AT HEAD, SILL OR JAMBS SG = 0,55 MIN. Ij Ij E2 li li li E2 CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. c N i i i i i C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN.. in ° 3 cn ,�1}lilllfpJ® c E1 E1 RA EN ij No.812 !3 A EDGE DIST. o \ v q v° 1 BY d o WOOD BUCK a t 1 Sealed:8/13/2020 %®��"°.e ° P��e drawing no. TYPICAL ANCHORS TYPICAL ANCHORS W1 6---76 SEE ELEV. EDGE DIST. SEE ELEV. FL #2 1 46 / FOR SPACING FOR SPACING �,P pp �q,j1,e sheet 4 of 9 LLi UD r- I co 1/4" MAX. O 1/.4.. MAX. Z M. a 1 SHIM SHIMS W 1/4' MAX. ILr^ o SHIMS 0 M 1 E2 TYPICAL ANCHORS TYPICAL ANCHORS ® W � U SEE ELEV. .. - SEE ELEV. N FOR SPACING 4 a .: FOR SPACING 12 0 All 11- 1/4„ 1 4/4' d j 7 ® IL 0 vi q a N N W U W coWv vSr Ld o IrF 2t Ld � E1 EXTERIOR 1 BY a a -4 A A a D.L. OPG. WOOD BUCKS 4 -i 0 1 SY WINDOW WIDTH WOOD BUCKS � m p rP /ivPICAL ANCHORS r. E ELEV. o. FOR SPACING D -� � 1/4" MAX, J -� LLI F.B.C. Q Of APPROVED MULLION SHIM F- SEE SEPARATE APPROVAL LLI _X m f FL �] � � m r---� I I TYPICAL ANCHORS O Z_ .(D II II SEE ELEV. Z n j I I j FOR SPACING w - M 11 11 LF ! U3iQ � .. I I Cn Q � i ui > E F � I 1� I I r U4V) II II jI �r Ij L—_. J _ — — — TYPICAL ANCHORS METAL U SEE ELEV. STRUCTURE -01 (D FOR SPACING WINDOW WIDTH WINDOW WIDTH c 0 o ``1111l➢ffle!®' w c 1 No. 81223 } Sealed:8/13/2020 ��®y a� ' drawing no. FL #21461 '���o� ® � W1 6-76 /�I11�1➢y 11 °°°° sheet 5 of 9 EDGE DIST. n I METAL F.B.C. APPROVED cD STRUCTURE MULLION & MULLION ANCHORS —. OD a D a N d p EDGE DIST. SEE SEPARATE APPROVAL t` U\ o F coQ a EDGE DIST. W ID a a a 0 ' po A E5 \ N E5 \ E5 G s��i Lu!F A.T. ® aaQ TYPICAL ANCHORS TYPICAL ANCHORS TYPICAL ANCHORS W N SEE ELEV. SEE ELEV. SEE ELEV. W V) LL- O FOR SPACING FOR SPACING FOR SPACING 3 a Q W 0) 00 I Q M � o Z I LLJ LLJ T 0 a ly- r R'i 1/4" MAX. Ld o IM h SHS O © �t z E5 ALT. o Z W TYPICAL ANCHORS J Z o SEE ELEV. L prq FOR SPACING I (n u7 a Li ui a b 4 b A a GJ C 0 a b Q � O 4 6 L U N TYPICAL ANCHORS a A SEE ELEV. FOR SPACING O W#NDOW WIDTH ui � v o a ALT. E5 �,�14blPPtddg®I EN cl rn o a INSTALLATION DETAILS WITH FLUSH FRAME ADAPTERS 81223 v v v a a SEE SHEETS 4 & 5 FOR WINDOW DETAILS �� e X a v° � b. D D p v s- v ® '° 5T �//1 drawing no. Sealed:8/13/2020 EDGE DIST: FL #2146 gyp►�� �'0 1, YY 16`7 6 1 ° �q N'11 °° Lf I t���`e sheet 6 of 9 TYPICAL ANCHORS ILLUSTRATIVE DTLS. ONLY SEE ELEV. w EXT. OR INT_ FINISHES `FdR SPACING It co NOT BY E.S. WOW. z j Q TYPICAL ANCHORS: SEE ELEV. FOR SPACING w ##10 WOOD SCREWS (GRADE 2 CRS) CL ui o INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 0 1-1/2" MIN. PENETRATION INTO WOOD � A ® mm O p > m pp A E6 � O rm O ALT. a a O "I ® aio0 Z" N #10 TEKS/SELF DRILLING SCREWS m AT 6 FROM ENDS AND 12 O.C. MAX. � Z 1/4" MAX. co GAP 1/2" MIN, O � o � r7 Z_ U x W LLJ O Q fr_. = O E6 ALT. p V) cn ,n 3 i� 0 W L� -It #10 TEKS/SELF DRILLING SCREWS O Z w AT 6 FROM ENDS �n AND 12 O.C. MAX. I I L j rQi i (n _i i Ld L LLJri � N E TYP;CAL ANCHORS EXTERIOR SEE ELEV. • FOR SPACING #10 TEKS/SELF DRILLING SCREWS WINDOW WIDTH w AT 6 FROM ENDS a� AND 12 O.C. MAX. o 2 E6 � .N ALT: I e���o�rlrrrae�®,, L CE < a /� No.81223 INSTALLATION DETAILS WITH FIN FRAME ADAPTERS v e = i6 N SEE SHEETS 4 & 5 FOR WINDOW DETAILS m _ ° ° s US e - 4 V ST °��� drawing no. Sealed:8/13/2020 , ° TYPICAL ANCHORS �� ® �\\\ 1 S_7 FOR SPACING FL #21461 ®''�1 r�1110%,'% sheet 7 of g V) �2:917 ITEM # PART # REgD. DESCRIPTION bIATERIAL MAlVF./SUPPLIER/REMARKS E1 ES-EL151 1 FRAME 6063-TG cn 937 .050 E2 ES-EL152 AS READ. FRAME SCREW COVER 6063--T6 - j 1.562 E4 ES-EL111 AS RQD. GLAZING BEAD (INSUL. LAM. GLASS) 6063-T6 - h 0 co E4A ES-EL116 AS RQD. GLAZING BEAD (INSUL. LAM. GLASS) 6063-T6 - m 1 .062 4 g n I '77 E5 ES-EL112 AS READ. FLUSH FRAME ADAPTER 6063-T6 - a i >n o 1 187 E6 ES-EL11.5 AS READ: FLUSH FRAME ADAPTER WITH FIN 6063-T6 - ® W cl E7 ES-EL110 AS RQD. GLAZING BEAD (7/16" LAM. GLASS) 6063-T6 - E1 FRAME E7A ES-EL123 AS RQD, GLAZING BEAD (7/16 LAM. GLASS) 6063-T6 - ® � c] 0 u; M1 #8 X V. - FRAME ASSEMBLY FASTENERS ST. STEEL PH SMS Cf a E M O 040 .277 M2 ES-5008A AS READ. EXTERIOR BULB GASKET SILICONE DUROMETER 60±5 SHORE A ® � M2A EL100-GO2 AS READ, EXTERIOR LEAF GASKET SILICONE DUROMETER 60±5 SHORE A 0 Z O .� M213 ES-H-340-G05 AS READ, EXTERIOR WEDGE GASKET SILICONE DUROMETER 65±5 SHORE A Q w N IL O 1.670 M3 80-372A 2/ LITE SETTING BLOCK AT 1/4 POINTS (LAM. GLASS) SILICONE DUROMETER 80t5 SHORE A a 0 Q J M4 EL100-801 2/ LITE SETTING BLOCK AT 1/4 POINTS (INSUL. LAM, GLASS) SILICONE DUROMETER 80±5 SHORE A 0 +�+ E2 FRAME SCREW COVER M5 #8 X 1" _ FLUSH/FIN FRAME ADAPTER ASSEMBLY FASTENERS ST. STEEL FH SMS r. 2.857 I .045 � � � .500 i .65 co 2.780 M Z U x o U E5. FLUSH FRAME ADAPTER -a 1.428 ¢Lu t� Lu 3: X_ 6] Cr3 !] 1.500 .063 O Z CD 500 ft fl R fl 1625 Li T— 045 2.7780� E6 FLUSH FRAME ADAPTER WITH FIN 0 L V Q1 C � O .y co a .519 519 135 057 e`�p°°° ,%CE13SlL`°°° Gi � o ell p .050— _� N _ T 62 - A50 .974 .62.4_5..._....-D .974 .624 5 Afi2 .974 62� 062 .974 p v o Y I .202 I -.202 �—.202 �—.202 Sealed:8/13/2020 tea°'° s ° °� drawing no. E7 E7A E4 E4A Fr #2 1 4 6 1 4��0 0 W 16-7 6 L GLAZING BEADS A� .1 a1 111 W\�°� sheet 8 of 9 w elo I M1 / / ® ZW F m �Q M5 4c2 O W C4 ca IL Cl N � Nti © ui q OEM ® (L0a $ O ® N �ruj}� N Ag W 5 U. 6 W N . O j 0 W Q WELDED W G>g JOINTS FLUSH FRAME ADAPTER CORNER 00 -j U) m d � � a z RECT. OR SQUARE WINDOWS CIRCULAR WINDOWS D w w cr w o Z J w fljS `" Q J /+ Lu M5 e O U N N FIN FRAME ADAPTER CORNER 0 0 FAa u r No.81223 � \ drawing no. Sealed:8/13/2020 ®� �• o 0�� W 6^ 76 FL #21461 '��°iQ/1 pf f 191 %%%\\�\\` (sheet 9 of 9